DTS PHARUS 1500 EB, PHARUS 1200, PHARUS 1200 EB User Manual

Page 1
PHARUS
User’s Manual Rel 1.3
D.T.S. Illuminazione srl - ITALY http://www.dts-lighting.it
GB
Made in Italy
Page 2
Le informazioni contenute in questo documento sono state attentamente redatte e controllate. Tuttavia non è assunta alcuna responsabilità per eventuali inesattezze. Tutti i diritti sono riservati e questo documento non può essere copiato, fotocopiato, riprodotto per intero o in parte senza previo consenso scritto della D.T.S . DTS si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche , funzionali o di design a ciascun proprio prodotto. D.T.S non assume alcuna responsabilità sull’uso o sull’applicazione dei prodotti o dei circuiti descritti.
The information contained in this publication has been carefully prepared and checked. However, no responsibility will be taken for any errors. All rights are reserved and this document cannot be copied, photocopied or reproduced, in part or completely, without prior written consent from D.T.S. D.T.S. reserves the right to make any aesthetic, functional or design modifications to any of its products without prior notice. D.T.S. assumes no responsibility for the use or application of the products or circuits described herein.
PHARUS
Les informations contenues dans le présent manuel ont été rédigées et contrôlées avec le plus grand soin. Nous déclinons toutefois toute responsabilité en cas d'éventuelles inexactitudes. Tous droits réservés. Ce document ne peut être copié, photocopié ou reproduit, dans sa totalité ou partiellement, sans le consentement préalable de .
D.T.S.
de design, sans préavis, à chacun de ses produits. décline toute responsabilité sur l'utilisation ou sur l'application des produits ou des circuits décrits.
Las informaciones contenidas en este documento han sido cuidadosamenteredactadas y controladas. Con todo, no se asume ninguna responsabilidad por eventuales inexactitudes. Todos los derechos han sido reservados y este documento no puede ser copiado, fotocopiado o reproducido, total o parcialmente, sin previa autorizaciónescrita de
D.T.S.
carácter estético, funcional o de diseño a cada producto suyo. no se asume responsabilidad de ningún tipo sobre la utilización o sobre la aplicació n de los productos o de los circuitos descritos.
se réserve le droit d'apporter toutes modifications et améliorations esthétiques, fonctionnelles ou
se reserva el derecho a aportar sin previo aviso cambios y modificaciones de
D.T.S
D.T.S.
D.T.S.
D.T.S.
Page 3
ARC 1200
PHARUS
INDEX:
1- TECHNICAL FEATURES 4 2- IMPORTANT SAFETY INFORMATION 7
2.1 Fire prevention
2.2 Prevention of electric shock
2.3 Protection against ultraviolet radiation
2.4 Safety
2.5 Level of protection against the penetration of solid and liquid objects
3- MOUNTING THE LAMP 8
3.1 Lamp alignment
4- VOLTAGE AND FREQUENCY 9 5- INSTALLATION 10
5.1 Protection against liquids
5.2 Movement
5.3 Risk of fire
5.4 Forced ventilation
5.5 Ambient temperature
6- MAINS CONNECTION 11
6.1 Protection
7- OPENING THE PROJECTOR HOUSING 12 8- IRIS REPLACEMENT 13 9- PROJECTOR USE 14
9.1 Focus and Zoom
9.2 Iris and Dimmer
10- PERIODIC CLEANING 16
10.1 Lenses and reflector
10.2 Fans and air passages 11- PERIODIC CONTROLS 16 12- DISPLAY FUNCTION 17 13- HIDDEN MENU 18 14- UNIT BALANCING 19
Page 4
1- TECHNICAL FEATURES
PHARUS is the latest evolution of the D.T.S. follow spots range. PHARUS is a new follow spot ideal for all professional applications (theatres, concerts, television studios, fashion displays, special events, etc). PHARUS offers a distinct improvement in projection quality - thanks to a new optical group with condenser lens. PHARUS is available in two models: PHARUS 1500 (fitted with a 1500 W discharge lamp) and PHARUS 1200 (fitted with a 1200 W discharge lamp). PHARUS offers also a series of updated functions that ensure effective and creative use: New customizable colour system (5 interchangeable gel filter holders); Linear iris-diaphragm (extractable); Linear zoom (7° to 16°); Linear focus; Mechanical dimmer with black-out. PHARUS is designed to resist all the rigours of continuous use: the body is made in aluminium and stainless steel, which offer high resistance to heat and mechanical stress. PHARUS is complete with external ballast (electromagnetic or electronic).
ARC 1200
PHARUS
PHARUS 1500 (Cod. 03.TP005.L)
Magnetic ballast 220-240V 50/60Hz
PHARUS 1500 (Cod. 03.TP005.120.L)
Magnetic ballast 110V 50/60Hz
PHARUS 1500 EB (Cod. 03.TP005.EB.L)
Electronic ballast 90-260V 50/60Hz
PHARUS 1200 (Cod. 03.TP009.L)
Magnetic ballast 220-240V 50/60Hz
PHARUS 1200 (Cod. 03.TP009.120.L)
Magnetic ballast 110V 50/60Hz
PHARUS 1200 EB (Cod. 03.TP009.EB.L)
Electronic ballast 90-260V 50/60Hz
Lamp
Lamp: HTI 1500W/D7/60 (PHARUS 1500) HTI 1200W/D7/60 (PHARUS 1200) Base: SFc-10-4 with notch
Page 5
1- TECHNICAL FEATURES
Optical group
New optical group with condenser lens Zoom 7° ÷ 16° Linear focus Extractable iris-diaphragm Mechanical dimmer with black-out
Colours
Colour changer (optional): 5 interchangeable gel filter holders Automatic switching system between colours
Gobos
Gobo holder for gobo projections (optional)
Construction
Made on aluminium and stainless steel High resistance to heat and mechanical stress Removable cover for easy access to lamp
Safety
Safety microswitches
Power supply
220-240V 50/60Hz electromagnetic ballast version 90V-260V 50/60Hz electronic ballast version Power consumption 1600 VA, with built-in power factor correction External ballast (electromagnetic or electronic)
Weight
21,2 Kg (PHARUS); 22,8 Kg (PHARUS with colour changer);
7 Kg (electronic ballast)
19 Kg (electromagnetic ballast).
ARC 1200
PHARUS
Dimensions (LxWxH) Projector (996 x 381 x 466mm) Projector with colour changer (1108 x 381 x 466mm) Ballast: electromagnetic (300 x 251 x 269mm), electronic (400 x 251 x 220mm)
996 mm
m
m 6
381 mm
46
Projector Packaging Dimensions (LxWxH) 1200 x 450 x 500 mm Weight 23,2 Kg
Ballast Packaging Dimensions (LxWxH) 350 x 300 x 310 mm Weight 20,5 Kg electromagnetic 8,5 Kg electronic
Page 6
1- TECHNICAL FEATURES
Accessories provided into PHARUS 1500/1200 unit box
1x User manual 1x 0505S021 Osram HTI 1500W/D7/60 discharge lamp (PHARUS 1500) 1x 0505S007 Osram HTI 1200W/D7/60 discharge lamp (PHARUS 1200) 2x 02M09653.46 U-SHAPE metal plates black colour for truss suspension 4x 0501O319 galvanized black Allen key screws 6x16mm (for U-SHAPE assembling) 4x 0501R212 galvanized washers diam. 6x12x 1,6mm (for U-SHAPE assembling)
Accessories provided into MAGNETIC/ELECTRONIC BALLAST unit box
1x 0520P014 Powercon male cable connector blue colour
ARC 1200
PHARUS
Accessories on request
0521C034 SINGLE FLIGHT CASE for one unit, compartment for accessories, professional tripod and colour changer, 4 swivel wheels, 4 dishes on cover for piling, 2 butterfly closures (1 each side).
03.TA204 COLOUR CHANGER
03.TA205 GOBO HOLDER
02K00516 EXTRACTABLE IRIS
0521A007 PROFESSIONAL TRIPOD
Page 7
2- IMPORTANT SAFETY INFORMATION
2.1 Fire prevention:
PHARUS 1500 uses a Osram HTI 1500W/D7/60 PHARUS 1200 uses a Osram HTI 1200W/D7/60
The use of any other alternative lamp is not recommended and will null and void the fixture's warranty.
-Never locate the fixture on any flammable surface.
-Minimum distance from flammable materials: 1 MT.
-Minimum distance from the closest illuminable surface: 2 MT.
-Replace any blown or damaged fuses only with those of identical value. Refer to the wiring diagram if there is any doubt.
-Connect the unit to mains power via a thermal magnetic circuit breaker.
2.2 Prevention of electric shock:
ARC 1200
PHARUS
-High voltage is present inside the unit. Unplug the unit prior to performing any function which involves touching the inside of the moving head, including lamp replacement.
-The level of technology inherent in the PHARUS requires the assistance of specialised personnel for all servicing. Please refer to an authorised DTS service centre.
-A good earth connection is essential for proper functioning of the projector.
-Never connect the unit without proper earth connection.
-The fixture should be located in places with a good air ventilation.
2.3 Protection against ultraviolet radiation:
-Never turn on the lamp if any of the lenses or filters are damaged. Their respective shielding functions will only operate efficiently if they are in perfect working order.
-Never look directly the lamp when it is on.
2.4 Safety:
-The external surface of the unit, at various points, may exceed 70°C. Always wear suitable hand protection when handling the unit.
-Always replace the lamp if any physical damage is evident.
-Never install the fixture in an enclosed area lacking sufficient air flow. The ambient temperature should not exceed 40°C.
-A hot lamp may explode, so always wait for at least 10 minutes prior to attempting to replace the lamp.
-Always wear suitable hand protection when handling the lamp.
2.5 Level of protection against the penetration of solid and liquid objects:
-The projector is classified as an ordinary appliance and its protection level against the penetration of solid and liquid objects is IP 20.
Page 8
3- MOUNTING THE LAMPS
Warning: Switch off the unit before replacing the lamp.
PHARUS
Osram HTI 1500W/D7/60 Power 1500W Luminous flux 145.000 lm Colour temperature 6.000°K Lampbase SFc10-4 Rated life 750 hours
1) Loose the two screws located on the rear side of the unit (photo 1) .
Osram HTI 1200W/D7/60 Power 1200W Luminous flux 110.000 lm Colour temperature 6.000°K Lampbase SFc-10-4 with notch Rated life 750 hours
Photo 2Photo 1 Photo 3
2) Remove the cover (photo2).
3)Insert the lamp on the lamp socket and tighten the lamp screws (photo 3). The lamp used on PHARUS 1500 is made in quartz glass and should be handled with care. Always follow the instructions supplied in the lamp's packaging. Never touch the glass directly but use the tissue provided in the lamp's packaging. The lamp socket is symmetrical. DO NOT USE UNDUE FORCE ON THE GLASS. In case of difficulty, read again the instructions and repeat the procedure.
3.1 Lamp alignment
The lamp socket is self centering; So, there is no need to align the lamp.
Page 9
PHARUS
4- VOLTAGE AND FREQUENCY
The PHARUS with electromagnetic ballast operates at 220-240 VOLT 50 or 60 Hz; available also at 110 VOLT 50 or 60 Hz.
Please note that Electromagnetic Ballast can not be use in Pharus 1500 EB Electronic ballast
On/Off switch
Main Ac Panel connector
Fuse holder
Projector
Fans speed regulation
connector
knob
socket
The PHARUS with electronic ballast operates at 90-260 VOLT 50 or 60 Hz.
Please note that Electronic Ballast can not be use with pharus 1500 Electromagnetic ballast
On/Off
Fuse holder
switch
Main Ac Panel connector
Projector connector socket
Page 10
10
5- INSTALLATION
PHARUS may be either floor or ceiling mounted. For floor mounting installations, the unit is provided with a bracket for fixing to floor stand. The floor stand from which the unit is fixed should be capable of bearing the weight of the unit. For ceiling mounted installations, we reccomend the use of appropriate clamps to fix the unit to the mounting surface. The supporting structure from which the unit is hung should be capable of bearing the weight of the unit, as should any clamps used to hung it. Two “U-SHAPE” metal plates included into the unit box, allow to hang the PHARUS on the truss by using an additional clamp (Clamp not included).
PHARUS
Bracket for fixing the unit to floor stand
SAFETY CABLE
!
2x 02M09653.46 U-SHAPE metal plates black colour provided into the unit box for truss suspension. We recommend the use of a safety cable connected to the unit and to the suspension truss in order to avoid the fixture accidentally falling should the main fixing point fail. Make sure that the iron cable can bear the weight of the entire unit.You may attach the safety cable as shown in the picture.
5.1- Protection against liquids
The projector contains electric and electronic components which should under no circumstances come into contact with oil, water or any other liquid. The proper unit functioning would be compromised should this occur.
Page 11
11
PHARUS
5.2- Movement
The projector has a maximum vertical movement of +/- 45°
+45°
-45°
Knobs for vertical position adjustment
5.3- Risk of fire
Each fixture produces heat and must be installed in a well-ventilated place. The minimum recommended distance from flammable material is 1 MT. Minimum distance from the object being illuminated is 2 MT.
5.4- Forced ventilation
You will note, on inspection, that the PHARUS features various air inlets and cooling fans located on both ballast and projector. These should, under no circumstances, be blocked or obstructed whilst the projector is in operation. Doing so could cause the fixture to seriously overheat thereby compromising its proper operation.
5.5- Ambient temperature
The projector should never be installed in places that lack a constant air flow. The ambient temperature should NOT exceed 40°C.
6- MAINS CONNECTION
PHARUS with electronic ballast operate at 90-260 VOLT 50-60 Hz. PHARUS with electromagnetic ballast operate at 220-240 VOLT 50-60 Hz
or 110 V 50-60 HZ.
Prior to connecting the unit to your mains supply, ensure that the model in your possession correctly matches the mains supply available. For connection purposes, ensure that your plug is capable of supporting 8 amps at 220-240V, Or 16 amps at 110 V Strict adherence to regulatory norms is strongly recommended.
Electromagnetic ballast 220-240 V 50/60 Hz or 110 V 50-60 Hz
Main AC Panel connector
6.1- Protection
The use of a thermal magnetic circuit breaker is recommended for each PHARUS. A good earth connection is essential for the correct operation of the projector.
Electronic ballast 90-260V 50 / 60Hz
Main AC Panel connector
Page 12
12
7- OPENING THE PROJECTOR HOUSING
It is possible to inspect the inside of the projector by opening the covers as indicated below.
ATTENTION
REMOVE MAINS POWER PRIOR TO ACCESSING THE PROJECTOR’S INTERNAL COMPONENTS.
REAR SIDE:
1) Loose the two screws located on the rear side of the unit (photo 1) .
2) Remove the cover (photo2)
PHARUS
Photo 2Photo 1
FRONT SIDE:
1) Loose the screws located on the bottom front side of the unit (photo 1) .
2) Now it is possible to move the covers for internal inspection (photo2 and 3)
Photo 2Photo 1 Photo 3
Page 13
13
8- IRIS REPLACEMENT
ATTENTION
REMOVE MAINS POWER PRIOR TO ACCESSING THE PROJECTOR’S INTERNAL COMPONENTS.
1) Move the dust cover toward the front of the unit (photo 1) .
2) Push the iris security lock (photo2).
3) Pull up the iris assembly (photo 3).
Photo 2Photo 1
PHARUS
Photo 3
Page 14
14
9- PROJECTOR USE
9.1 Focus and Zoom
Focus and zoom adjustment lenses, are located on the front side of the unit. Place the projector on the object to illuminate, loose the fixing lenses , adjust the lenses position till the projection is whell focused on the object. Thighten the knobs
.
PHARUS
knobs
FOCUS ZOOM
FOCUS ZOOM
Page 15
15
9.2 Iris and Dimmer
Iris and Dimmer, are located on the front side of the unit. Move the iris from left side to right side to reduce the projected area (photo 1 and 2). Move the Dimmer from right side to left side to reduce the light output intensity till blackout. (photo 3 and 4).
PHARUS
Photo 2Photo 1
IRIS FULL OPEN
IRIS FULL CLOSED
Photo 4Photo 3
DIMMER FULL OPEN
DIMMER FULL closed
Page 16
16
10- PERIODIC CLEANING
10.1- Lenses and reflectors
Even a fine layer of dust can reduce the luminous output substantially. Regularly clean all lenses and the reflector using a soft cotton cloth, dampened with a specialist lens cleaning solution.
10.2- Fans and air passages
The fans and air passages must be cleaned approximately every 6 weeks. This periodic cleaning will depend of course, on the conditions in which the projector is operating. Suitable instruments for performing this type of maintenance are a brush and a common vacuum cleaner or an air compressor. If necessary, clean the fans and air passages more frequently.
11- PERIODIC CONTROLS
PHARUS
Lamp
The lamp should be replaced if there is any visible damage or deformation due to heat. This will help to avoid the danger of the lamp exploding.
Mechanical parts
Periodically check all mechanical parts. Periodically check the lubrication of all components, particularly the parts subject to high temperatures. If necessary, lubricate with suitable lubricant, available from your D.T.S. Distributor.
Electrical components
Check all electrical components for correct earthing and proper connection of all connectors, refastening if necessary.
Fuse replacement
Locate the fuse, which protects the lamp and electronics, in the balast of the PHARUS Using a multimeter, test the condition of the fuse, replacing it with one of equivalent type if necessary.
Attention
Disconnect mains power prior to removing the projector housing.
Page 17
12- DISPLAY FUNCTIONS
PHARUS ELECTRONIC
BALLAST
17
PHARUS
PHARUS
MENU
ENTER
DOWN
UP
DISPLAY FUNCTIONS
The PHARUS ELECTRONIC BALLAST display panel shows all the available functions . Using these functions, it is possible to change some of the parameters and add some functions. Changing the D.T.S. setting can vary the functions of the unit so that it does not respond to the DMX 512 signal used to control it. Carefully follow the instructions below before carrying out any variations or selections. NOTE: the symbol shows which key has to be pushed to obtain the desired function.
=
C.MEM
MENU
Software version 2.10
MENU
TIMER Visualization of lamp life (reset possible) and total time unit's working (reset not possible)
+
DOWN
Up-Down
ENTERUp-Down
Up-Down
Up-Down
ENTER
ENTER
ENTER
BALLAST LIFE TIME HOURS
BALLAST LIFE TIME MINUTES
LAMP LIFE TIME HOURS
Up-Down
MENU
BALLAST MONITOR Lamp Power Lamp Voltage Lamp Current Power supply temperature monitor (PFC and DC/DC side) Password DMX address
AddM DMX address (no Function on Pharus 1200/1500 electronic ballast)
ENTER
Up-Down
Up-Down
Up-Down
Up-Down
Up-Down
Up-Down
Up-Down
Up-Down
Up-Down
ENTER
LAMP STRIKES
ENTER
Up-DownENTER
Up-DownENTER
Up-DownENTER
Up-DownENTER
Up-DownENTER
Up-DownENTER
Up-DownENTER
LAMP LIFE TIME MINUTES
C.MEM
NOMINAL LAMP POWER
LAMP VOLTAGE
LAMP CURRENT
POWER SUPPLY TEMP.
POWER SUPPLY TEMP.
INSERT PASSWORD DEFAULT:1500
SHOW AND CHANGE DMX ADDRESS
TO RESET
PFC SIDE
DC/DC SIDE
Page 18
18
PHARUS
LAMP FORCED OFF
LAMP FORCED ON
SOFTWARE VERSION
LAMP ON/OFF lamp
Up-Down
Up-Down
Up-DownMENU ENTER
Up-Down
Up-DownMENU ENTER
ENTER
ENTER
SOFTWARE Software version
13- HIDDEN MENU
For technical personnel only.
To operate this menu:
-Enter in Ballast monitor “Mon.b” select “sec.n”, enter the default code “1500” and Press C.MEM = “menu” + “down”
Up-Down
MENU
Up-DownENTER Up-DownENTER
C.MEM
=
MENU
+
DOWN
C.MEM
=
MENU
+
DOWN
MENU
Up-Down
MENU
BALLAST MONITOR
Up-Down
MENU
ENTERUp-Down
ENTER
ENTER
Up-Down
Up-Down
Up-Down
Up-Down
Up-Down
Up-Down
Up-Down
ENTER
RESET TIME AND
C.MEM
STRIKE LAMP
RESTORE FACTORY
Up-DownENTER
C.MEM
SETTING
DOWNLOAD SOFTWARE
Up-DownENTER
Up-DownENTER
Up-DownENTER
Up-DownENTER
C.MEM
UPLOAD SOFTWARE
C.MEM
CHANGE PASSWORD
C.MEM
Up-DownENTER
C.MEM
CHANGE FREQUENCY OUTPUT
Up-DownENTER
Up-DownENTER
C.MEM
LAMP POWER
Page 19
19
14- UNIT BALANCING WITH AND WITHOUT COLOUR CHANGER
Pharus balancing without colour changer:
PHARUS
Pharus balancing with colour changer:
OR
COLOUR CHANGER
CODE: 03.TA204
Page 20
The information contained in this publication has been carefully prepared and checked. However, no responsibility will be taken for any errors. All rights are reserved and this document cannot be copied, photocopied or reproduced, in part or completely, without prior written consent from D.T.S. D.T.S. reserves the right to make any aesthetic, functional or design modifications to any of its products without prior notice. D.T.S. assumes no responsibility for the use or application of the products or circuits described herein.
MADE IN ITALY
ISO 9001:2008
D.T.S. quality system
is certified to the
ISO 9001:2008 standard
D.T.S. products are designed and manufactured at the D.T.S. plants in italy
*0517I084*
0517I084
D.T.S. Illuminazione s.r.l - Via Fagnano Selve 10-12-14 47843 - Misano Adriatico (RN) Italy
Tel. +39 0541 611131 Fax +39 0541 611111 info@dts-lighting.it www.dts-lighting.it
Loading...