DELTA R
DELTA R FULL COLOR
DELTA R TRILED
GB
User’s Manual Rel 1.5
D.T.S. Illuminazione srl - ITALY http://www.dts-lighting.it
Made in Italy
Page 2
2
Le informazioni contenute in questo documento sono state attentamente redatte e controllate. Tuttavia
non è assunta alcuna responsabilità per eventuali inesattezze. Tutti i diritti sono riservati e questo
documento non può essere copiato, fotocopiato, riprodotto per intero o in parte senza previo consenso
scritto della D.T.S .
DTS si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche , funzionali o di
design a ciascun proprio prodotto. D.T.S non assume alcuna responsabilità sull’uso o sull’applicazione dei
prodotti o dei circuiti descritti.
DELTA R
The information contained in this publication has been carefully prepared and checked. However, no
responsibility will be taken for any errors. All rights are reserved and this document cannot be copied,
photocopied or reproduced, in part or completely, without prior written consent from D.T.S.
D.T.S. reserves the right to make any aesthetic, functional or design modifications to any of its products
without prior notice. D.T.S. assumes no responsibility for the use or application of the products or circuits
described herein.
Les informations contenues dans le présent manuel ont été rédigées et contrôlées avec le plus grand
soin. Nous déclinons toutefois toute responsabilité en cas d'éventuelles inexactitudes. Tous droits
réservés. Ce document ne peut être copié, photocopié ou reproduit, dans sa totalité ou partiellement,
sans le consentement préalable de .
D.T.S.
de design, sans préavis, à chacun de ses produits. décline toute responsabilité sur l'utilisation ou
Todos los derechos han sido reservados y este documento no puede ser copiado, fotocopiado
D.T.S.
estético, funcional o de diseño a cada producto suyo. no se asume responsabilidad de
se réserve le droit d'apporter toutes modifications et améliorations esthétiques, fonctionnelles ou
D.T.S.
sur l'application des produits ou des circuits décrits.
Las informaciones contenidas en este documento han sido cuidadosamenteredactadas y
controladas. Con todo, no se asume ninguna responsabilidad por eventuales inexactitudes.
o reproducido, total o parcialmente, sin previa autorizaciónescrita de
se reserva el derecho a aportar sin previo aviso cambios y modificaciones de carácter
D.T.S.
ningún tipo sobre la utilización o sobre la aplicació
n de los productos o de los circuitos descritos.
D.T.S
D.T.S.
Page 3
3
DELTA R
INDEX:
1- TECHNICAL FEATURES 4 2- IMPORTANT SAFETY INFORMATION 8
2.1 Fire prevention
2.2 Prevention of electric shock
2.3 Protection against direct light radiation
2.4 Safety
2.5 Level of protection against the penetration of solid and liquid matter
3- VOLTAGE AND FREQUENCY 9 4- INSTALLATION 9
4.1 Safety cable
4.2 Risk of fire
4.3 Ambient temperature
5- MAINS CONNECTION 10
5.1 Protection:
6- DMX SIGNAL CONNECTION 10
6.1 DMX Addresses
6.2 Selecting the DMX address
7- MOVEMENT 11 8- DISPLAY FUNCTIONS 12
9- OPENING UP THE PROJECTOR HOUSING 25
9.1 Arms
9.2 base
10- CHANGHING THE LENSES 26 11- PERIODIC CLEANING 28 12- PERIODIC CONTROLS 13- DMX PROTOCOL 29
Page 4
4
DELTA R
1- TECHNICAL FEATURES
Delta R Full Color
40 RGB Full Color LEDs/ LED power 3W
2.800 Lumens / 370 Lux at 5 m (medium flood lenses) RGB color generation / 16 million colours Colour temperature variable on a linear range (3.200°K÷5.500°K) No infrared emission / no ultraviolet emission LEDs average lifespan: 100.000 hours Optical units can be interchanged by users (spot / medium /wide) Interface: OLED display + 4 buttons / infrared remote control Control signals: USITT DMX 512 USITT serial digital signals 15 DMX channels Independent operation (Master / Slave) Programmable automated playback (7 days) Movement on 3 axes : Pan 320° /Tilt1 160°(Motorized) / Tilt2 135°(Manual). Safety-locking system IP65 protection level Professional HARTING / ILME sockets (IP65 protection rating) Full range AC 90-260V, 50-60Hz power supply Operating ambient temperature -10° / 40° Weight: 24 Kg
ACCESSORIES
Lenses set spot (cod. 03.LK.008) Lenses set medium flood (cod. 03.LK.001) Lenses set wide flood (cod. 03.LK.002) Flight case for 1 DELTA (cod. 0521C029) Flight case for 2 DELTA (cod. 0521C030) Safety wire (3mm x 60 cm), Ring spring catch (max. capacity load 60Kg) (Cod. 0521A010) “C” Clamp GQUICK with “Fast Lock” connection ¼ turn (max. load 80Kg) (cod. 0521A014)
Dimensions (LxDxH) projector 430 x 285 x 570 mm
Weight24 Kg (motorized version)
Packaging Dimensions (LxDxH)
530 x 500 x 660 mm
Weight 30 Kg (motorized version)
Page 5
5
DELTA R
Delta R Triled
20 LEDs / TRILED technology / LED power 1W x 3
2.400 Lumens / 450 Lux at 5 m (medium flood lenses) RGB color generation / 16 million colours Colour temperature variable on a linear range (3.200°K÷5.500°K) No infrared emission / no ultraviolet emission LEDs average lifespan: 100.000 hours Optical units can be interchanged by users (spot / medium flood / wide flood) Interface: OLED display + 4 buttons / infrared remote control Control signals: USITT DMX 512 USITT serial digital signals 15 DMX channels Independent operation (Master / Slave) Programmable automated playback (7 days) Movement on 3 axes : Pan 320° /Tilt1 160°(Motorized) / Tilt2 135°(Manual) Safety-locking system IP65 protection level Professional HARTING / ILME sockets (IP65 protection rating) Full range AC 90-260V, 50-60Hz power supply Operating ambient temperature -10° / 40° Weight: 24 Kg
ACCESSORIES
Lenses set spot (cod. 03.LK.004) Lenses set medium flood (cod. 03.LK.005) Lenses set wide flood (cod. 03.LK.006)
Flight case for 1 DELTA (cod. 0521C029) Flight case for 2 DELTA (cod. 0521C030) Safety wire (3mm x 60 cm), Ring spring catch (max. capacity load 60Kg) (Cod. 0521A010) “C” Clamp GQUICK with “Fast Lock” connection ¼ turn (max. load 80Kg) (cod. 0521A014)
Dimensions (LxDxH) projector 430 x 285 x 570 mm
Weight24 Kg (motorized version)
Packaging Dimensions (LxDxH)
530 x 500 x 660 mm
Weight 30 Kg (motorized version)
Page 6
6
DELTA R
1- TECHNICAL FEATURES
Delta 5 RGB R
108 X 1W Luxeon type LEDS (36 Red, 36 Green, 36 Blue)
2.400 Lumens / 900 Lux at 5 m (medium flood lenses) RGB color generation / 16 million colours Colour temperature variable on a linear range (3.200°K÷5.500°K) No infrared emission / no ultraviolet emission LEDs average lifespan: 100.000 hours Optical units can be interchanged by users (spot / medium /wide) Interface: OLED display + 4 buttons / infrared remote control Control signals: USITT DMX 512 USITT serial digital signals 15 DMX channels Independent operation (Master / Slave) Programmable automated playback (7 days) Movement on 3 axes : Pan 320° /Tilt1 160°(Motorized) / Tilt2 135°(Manual). Safety-locking system IP65 protection level Professional HARTING / ILME sockets (IP65 protection rating) Full range AC 90-260V, 50-60Hz power supply Operating ambient temperature -10° / 40° Weight: 24 Kg
ACCESSORIES
Lenses set spot (cod. 03.LK.008) Lenses set medium flood (cod. 03.LK.001) Lenses set wide flood (cod. 03.LK.002) Flight case for 1 DELTA (cod. 0521C029) Flight case for 2 DELTA (cod. 0521C030) Safety wire (3mm x 60 cm), Ring spring catch (max. capacity load 60Kg) (Cod. 0521A010) “C” Clamp GQUICK with “Fast Lock” connection ¼ turn (max. load 80Kg) (cod. 0521A014)
Dimensions (LxDxH) projector 430 x 285 x 570 mm
Weight24 Kg (motorized version)
Packaging Dimensions (LxDxH)
530 x 500 x 660 mm
Weight 30 Kg (motorized version)
Page 7
7
DELTA R
1- TECHNICAL FEATURES
Delta 7 RGB R
108 X 1W P4 type LEDS (36 Red, 36 Green, 36 Blue)
2.400 Lumens / 1150 Lux at 5 m (medium flood lenses) RGB color generation / 16 million colours Colour temperature variable on a linear range (3.200°K÷5.500°K) No infrared emission / no ultraviolet emission LEDs average lifespan: 100.000 hours Optical units can be interchanged by users (spot / medium /wide) Interface: OLED display + 4 buttons / infrared remote control Control signals: USITT DMX 512 USITT serial digital signals 15 DMX channels Independent operation (Master / Slave) Programmable automated playback (7 days) Movement on 3 axes : Pan 320° /Tilt1 160°(Motorized) / Tilt2 135°(Manual). Safety-locking system IP65 protection level Professional HARTING / ILME sockets (IP65 protection rating) Full range AC 90-260V, 50-60Hz power supply Operating ambient temperature -10° / 40° Weight: 24 Kg
ACCESSORIES
Lenses set spot (cod. 03.LK.008) Lenses set medium flood (cod. 03.LK.001) Lenses set wide flood (cod. 03.LK.002) Flight case for 1 DELTA (cod. 0521C029) Flight case for 2 DELTA (cod. 0521C030) Safety wire (3mm x 60 cm), Ring spring catch (max. capacity load 60Kg) (Cod. 0521A010) “C” Clamp GQUICK with “Fast Lock” connection ¼ turn (max. load 80Kg) (cod. 0521A014)
Dimensions (LxDxH) projector 430 x 285 x 570 mm
Weight24 Kg (motorized version)
Packaging Dimensions (LxDxH)
530 x 500 x 660 mm
Weight 30 Kg (motorized version)
Page 8
8
DELTA R
2- IMPORTANT SAFETY INFORMATION
2.1 Fire prevention:
-Never locate the fixture on any flammable surface.
-Minimum distance from flammable materials: 1 m.
-Minimum distance from the closest illuminable surface: 1 m.
-Replace any blown or damaged fuses only with those of identical value. Refer to the wiring diagram if there is any doubt.
-Connect the projector to mains power via a thermal magnetic circuit breaker.
2.2 Prevention of electric shock:
-High voltage is present inside the unit. Isolate the projector from the mains supply prior to performing any function which involves touching the inside of the unit.
-The level of technology inherent in the DELTA R requires the assistance of specialised personnel for all servicing.Please refer to an authorised DTS service centre.
-A good earth connection is essential for proper functioning of the projector. Never connect the unit without proper earth connection.
-The fixture should be located in places with a good air ventilation.
2.3 Protection against direct light radiation:
-Never turn the unit on if any of the lenses or the glass lenses protection is damaged.
-Never look directly the leds when they are on.
2.4 Safety:
-The projector should always be installed with bolts, clamps and other tools that are capable of supporting the weight of the unit.
-Always use a second safety chain to sustain the weight of the unit in case of the failure of the main fixing point.
-The external surface of the unit, at various points, may exceed 80°C. Never handle the unit until it’s on.
-Never install the fixture in an enclosed area lacking sufficient air flow.
-The ambient temperature should not exceed 40°C.
2.5 Level of protection against the penetration of solid and liquid matter:
-The projector is classified as an ordinary appliance and its protection level against the penetration of solid and liquid matter is IP 65.
Page 9
9
.
DELTA R
3- VOLTAGE AND FREQUENCY:
Delta R can operate at 90-270V, 50 or 60 Hz.
4- INSTALLATION:
Delta R may be either floor or ceiling mounted. For floor mounting installations, the unit is supplied with four rubber mounting feet on the base. For ceiling mounted installations, we reccommend the use of appropriate clamps to fix the unit to the mounting surface. The supporting structure from which the unit is hung should be capable of bearing the weight of the unit, as should any clamps used to hung it. The structure should also be sufficiently rigid so as not to move or shake whilst the Delta R is moving. The Delta R is fitted with 4 fixing points on the bottom used to attach accessories (clamps, hooks, etc.) With a fast lock closure/release system (1/4 turn) to fix the fixture in any position. .
4.1 Safety cable:
We recommend the use of a safety cable or chain connected to the Delta R and to the suspension truss in order to avoid the fixture accidentally falling should the main fixing point fail. Make sure that the iron cable or chain can bear the weight of the entire unit. You may attach the safety chain to the holes located on the base of the fixture, as shown in the picture below.
SAFETY CABLE FIXING POINT
4.2 Risk of fire:
Each fixture produces heat and must be installed in a well-ventilated position. The minimum recommended distance from flammable material is 1m. Minimum distance from the object being illuminated is 1 m.
Page 10
10
DELTA R
4.3 Ambient temperature:
The projector should never be installed in places that lack a constant air flow. The ambient temperature should NOT exceed 40°C.
5- MAINS CONNECTION:
Delta R can operate at 90-270V, 50 or 60Hz. For connection purposes, ensure that your plug can handle at least 300W power consuption.
Strict adherence to regulatory norms is strongly Recommended.
FUSE: T 3,15A
MAINS
Electronic ballast 90-260V 50 / 60Hz
5.1 Protection:
4
3
1
2
The use of a thermal magnetic circuit breaker is recommended for each Delta R. A good earth connection is essential for the correct operation of the projector.
6- DMX SIGNAL CONNECTION:
The unit operates using a digital DMX 512 (1990) signal. Connection between the control box and the projector or between projectors must be carried out using a two pair screened ø0.5 mm cable and a CANNON XLR 5 or 3 pole connector.
Ensure that the conductors do not touch each other.Do not connect the cable ground to the XLR chassy The plug housing must be isolated. Connect the mixer signal to the DMX IN projector plug and connect it to the next projector by connecting the DMX OUT plug on the first projector to the DMX IN plug of the second one. In this way, all the projectors are cascade connected.
CONTROLLER S T A N D A R D D M X 5 1 2
5
4 2
3
1
1=GND 2=DATA­3=DATA+
DMX IN
DMX OUT
OUT
IN
OUT
IN
OUT OUT
IN
P.S: If the display showing the DMX address flashes, then one of the following errors has occurred:
- DMX signal not present
- DMX reception problem
Page 11
11
6.1 DMX Addresses:
DELTA R have 15 DMX control channels. Here below are described the DMX channels addressing for the controller:
Projector 1 A001 Projector 2 A016 If you want to select the next projector, just add “15” Projector 3 A031 ….. A…. projector 6 A091
6.2 Selelcting the DMX address:
1) Press the UP-DOWN key until you reach the required DMX address. The numbers on the display will start to flash (but the new DMX address hasn't yet been set).
2) Press ENTER to confirm your selection. The numbers on the display will stop flashing and the projector is now controlled by the new DMX address.
DELTA R
TIPS: if you keep pushed the UP or DOWN keys, the channels are calculated more quickly and you get a faster selection.
MENU
ENTER
UP
DOWN
7- Movement
The projector has a maximum movement of 320° for Pan,180° for Tilt 1 and 135° for tilt 2 (7 mechanical steps 22,5° each). DO NOT place any obstructions in the path of the projector's movement.
Tilt 2 mechanical regulation
PAN 320°
TILT1 180° Motorized
TILT2 135° Mechanical
Page 12
12
DELTA R
8- DISPLAY FUNCTIONS
DISPLAY FUNCTIONS
The DELTA R display panel shows all the available functions . Using these functions, it is possible to change some of the parameters and add some functions. Changing the DTS setting can vary the functions of the unit so that it does not respond to the DMX 512 used to control it. Carefully follow the instructions below before carrying out any variations or selections.
DELTA SOFTWARE RELEASE 1.72
1)GLOBAL SETTING MENU
LANGUAGE DEFAULT PAGE SECURITY DEFAULT SETTING SET DATE SET TIME UPDATE DOWNLOAD ABOUT
2)MODE SETTING MENU
MODE DMX MODE RECORDER MODE MASTER MODE SLAVE MODE IR MODE MANUAL MODE TWILIGHT
3)MOVING HEAD SETUP MENU
PAN MIN PAN MAX TILT MIN TILT MAX CALIBRATE PAN CALIBRATE TILT INVERT PAN INVERT TILT SWAP PAN & TILT ENCODER RESET PAN & TILT SPEED PAN & TILT
4)LED SETUP MENU
COLOUR MODE WHITE BALANCE BOOST DRIVING MIN RGB MAX RGB SMOOT FILTER PWM FREQUENCY
5)DIPLAY SETTINGS MENU
CONTRAST FLIP DISPLAY SCREEN SAVER
6)MEASURE MENU
LIFE DMX VOLTAGE TEMPERATURA TWILIGHT
Page 13
1)GLOBAL SETTING MENU
LANGUAGE DEFAULT PAGE SECURITY DEFAULT SETTING SET DATE SET TIME UPDATE DOWNLOAD ABOUT
13
DELTA R
Menu
A001
Up-Down
LANGUAGE SELECTION This menu allow to set the
Up-Down
DEFAULT PAGE SELECTION This menu allow to set the visualisation for the start up page
Up-Down
SECURITY PASSWORD This menu allow to select a security password to lock the user’s settings
Language
Default Page
Security
Up-Down
GLOBAL SETTING
Up-DownENTER
Up-Down
Up-DownENTER
Up-Down
Up-DownENTER
Up-Down
Set Language English
Set Default Page
Four Digit
A001
Status
Security Unlocked
Enter Security Code 0 0 0 0
ENTER
English = Default
Four Digit = DMX address visualisation
Status = DMX / Color Mode / Boost Power / Security
Default 0000 = no password
Universal Unlock code = 2903
ENTER
ENTER
ENTER
ENTER
Up-Down
DEFAULT SETTINGS This menu allow to set the unit to the company settings
Up-Down
DATE SETTING This menu allow to set the day of the week the month and the year
Default Setting
Set Date
Up-DownENTER
Up-Down
Up-DownENTER
Confirm Security Code 0 0 0 0
Restore Main Settings
ENTER to CONFIRM & Reboot
Set Date
Year 2007 Month Jan Day of the month 01 Day of the week Mon
GAME,TIMER and WHITE SETTING will not be changed
Date settings for Stand Alone mode
ENTER
ENTER
ENTER
Page 14
14
DELTA R
Up-Down
TIME SETTING This menu allow to set the unit’s on board clock for STAND ALONE MODE
Up-Down
UPDATE MENU This menu allow to upgrade the uni’s software by computer or remote control
Up-Down
DOWNLOAD MENU This menu allow to save unit’s programs into computer
Set Time
Update
Download
Up-DownENTER
Set Time
Real time internal clock setting
ENTER
Hour 03
Minute 01
Up-DownENTER
Select UPDATE Mode Direct to PC
Update the unit’s software from PC by cable
ENTER
ENTER to CONFIRM
Up-DownENTER
Select DOWNLOAD Mode Direct to PC
Download the unit’s program to PC by cable
ENTER
ENTER to CONFIRM
Up-Down
ABOUT MENU This menu show informations about unit’s hardware and software
ABOUT
ENTER
Up-Down
About DELTA R Master PCB 0514L019 Loader Version 1.02 HW Version 1.01 SW Version 1.61 Pan&Tilt PCB 0514S100 PAn&Tilt Version 2.05
Unit’s Hardware and software infos
ENTER
Page 15
2)MODE SETTING MENU
MODE DMX MODE RECORDER MODE MASTER MODE SLAVE MODE IR MODE MANUAL MODE TWILIGHT
15
DELTA R
Menu
A001
Up-Down
DMX ADDRESS SELECTION This menu allow to set the unit’s DMX address.
Up-Down
RECORDER MODE SETTING This menu let you create 2 different chases,CPR1 and CPR2 (16 steps each) that will then run in Master Mode. Two different recording mode are available:
1)Manual Recording Mode
2)DMX Recording Mode
1)Manual Recording Mode
Mode DMX
Mode Recorder
Up-Down
MODE SETTINGS
Up-DownENTER
Up-DownENTER
Set Address DMX
001
RECORDER Mode
Input Mode MANUAL
Select Chase CPR1
RECORDER MANUAL CPR1 STEP 01 EDIT PAN 016 TILT 255 SHUTTER 009 DIMM 017 R 016 G 016 B 000 WHITE 012 CTC 000 MACRO 000
ENTER
Address range 001-489
In Manual Recording Mode,it is possible to create and store the steps of the chase by using the unit display panel and buttons.
Three different options are available:
1)EDIT = Let you modify and store new values for all the channels on the selected Step.
2)WIEV MEM = Let you see the existing programmed steps of the chase
3)SET LAST = Let you set the last step to be ran on the chase.
ENTER
ENTER
2)DMX Recorder Mode To program CPR1 and CPR2 by using a DMX controller, 3 more DMX channels are needed in addition to the 15 channels necessary to control the unit. So that in RECORDER mode (via DMX) the unit will need 18 channels to be correctly programmed. The 3 new DMX channels are: DMX channel 16 = STEPS channel From 0 - 15 = VIEW DMX, the unit shows the values received from the DMX controller in that moment. From 16 – 255, the previously programmed steps (16 steps from 01 to 16) are displayed. DMX channel 17 = VIEW / EDIT / SET LAST channel If channel 16 (STEPS channel) is set to value 0 - 15, the DMX channel 17 has no functions. If channel 16 (STEPS channel) is set to value 16 - 255, the DMX channel 17 has the following functions: From 0 - 19 = VIEW MEM, the unit shows the previously programmed steps. From 20 - 234 = EDIT, the unit runs the configuration given by the DMX controller in that moment.
With the STEPS channel it is possible to select the step to create, while with REC channel it is possible to store the configuration on the selected step.­From 234 - 255 = SET LAST, the unit runs the configuration given by the DMX controller in that moment closing the Program as last step. With the REC channel it is possible to record the selected step as last step to be ran on the Program. DMX channel 18 = REC channel REC channel saves the configuration given by the DMX controller in the selected step: you change the DMX value from 0 to 255 (the display shows “WRITING” indicating that the step has been recorded). We suggest to keep the REC channel set to 0 and to run through the 255 only once you have decided to save the new configuration. If CPR1 or CPR2 are not closed, by indicating the last step (Edit channel between 235-255), all 16 steps will be played through in playback mode, even if not programmed.
RECORDER Mode
Input Mode DMX
Select Chase CPR1
Warning 18 channels !
RECORDER DMX CPR1 STEP 01 EDIT PAN 016 TILT 255 SHUTTER 009 DIMM 017 R 016 G 016 B 000 WHITE 012 CTC 000 MACRO 000
In DMX Recording Mode,it is possible to create and store the steps of the chases by using an external DMX controller.
WARNING !
To program CPR1 and CPR2 by using a DMX controller, 3 more DMX channels are needed in addition to the 15 channels necessary to control the unit.
ENTER
Page 16
16
DELTA R
Up-Down
MASTER MODE SETTING This menu allow to set Delta R as master unit (No DMX signal must be present on unit’s DMX input panel) . The unit will ran in automatic mode without needing of an external controller. Different chases are selectable by user
CPR1/CPR2/CPR1&2 Chases with 16 steps previously created in RECORDER mode. Time and Wait time selectable by user
CRNB Rainbow colours effect. Time and Pan&Tilt selectable by user
CUE 1-9 Color Macros with fixed colors Pan&Tilt selectable by user
Mode Master
Up-DownENTER
Up-Down
Set MASTER MODE
Mode : MASTER Actual : DMX
ENTER to CONFIRM
Master Mode
Set CHASE CPR1 Set TIME Sec 0025 Set WAIT Sec 0015
The Delta setted as MASTER, send DMX signal to all the other units connected to the same DMX line
By setting all the units connected to the MASTER, to DMX address 1, them will be sinchronized with the Master unit following the chase selected on it, including TIME, WAIT and Pan&Tilt position of the MASTER unit.
By setting all the units connected to the MASTER, as SLAVE unit (see SLAVE mode), them will be sinchronized with the Master unit only for TIME and WAIT time, but running their own chase CPR1/CPR2 with dedidicated Pan&Tilt position, colors and effects.
ENTER
ENTER
Up-Down
SLAVE MODE SETTING This menu allow to set the Delta R as slave unit. DMX signal must be present from MASTER unit in order to ran in SLAVE mode.
Mode Slave
Up-DownENTER
Set SLAVE MODE
The SLAVE unit receive DMX signal
ENTER
from the MASTER unit
Mode : SLAVE Actual : DMX
By setting all the units connected to the MASTER, as SLAVE unit, them
ENTER to CONFIRM
will be sinchronized with the Master unit only for TIME and WAIT time, but running their own chase CPR1/CPR2 with dedidicated Pan&Tilt position, colors and effects.
Page 17
17
DELTA R
Up-Down
IR MODE SETTING By activating IR mode on Delta unit it will be possible to navigate trought the unit functions by using the D.T.S. infrared remote control (D.T.S. Code :0514L008).
Mode IR
Up-DownENTER
Set IR MODE
Mode : IR Actual : DMX
ENTER to CONFIRM
INFRARED REMOTE CONTROL
By activating IR mode on Delta unit it will be possible to navigate trought the unit functions by using the D.T.S. infrared remote control (D.T.S. Code :0514L008).
Infrared remote control functions:
ON/OFF and MUTE buttons
In Master/Slave mode let you stop the games running. Master and slave units will go in Stand-by mode
1-9 buttons
Let you select the chase to run (CPR1/CPR2/CRNB/CUE 1-6)
1-/.. Button
Let you select the chase to run (CUE 7-9)
VOL +/-
No function
PROG +/-
Let you scroll between the selectable chases
RED/GREEN/YELLOW/BLUE buttons
Direct acces to cues for Red/Green/Blue/Yellow colour. Red=CUE1 / Green=CUE3 / Yellow=CUE2 / Blue=CUE5
Navigation buttons
Same as UP/DOWN on unit display
OK button
Same as ENTER on unit display
MENU button
Same as MENU on unit display
The unit is controlled by the infrared remote control
ON/OFF Button
1-/.. Button
VOL +/­Buttons
NAVIGATION Buttons
OK Button
ENTER
1-9 Buttons
PROG +/­Buttons
R-G-Y-B Buttons
MENU Button
Up-Down
MANUAL MODE SETTING This menu let you control Delta unit in manual mode by using the unit display. In MANUAL mode, no external controller is needed.
Mode Manual
Up-DownENTER
Set MANUAL MODE
In MANUAL mode it is possible to
ENTER
adjust all the unit functions by using
Mode : MANUAL Actual : DMX
ENTER to CONFIRM
MAN Mode Enter VALUES
Channel Value PAN H 128
UP/DOWN and ENTER buttons:
PAN H PAN L TILT H TILT L SPEED PAN&TILT SHUTTER DIMMER RED GREEN BLUE WHITE CTC MACRO FUNCTION RESET
Page 18
18
DELTA R
Up-Down
TWILIGHT MODE MENU This menu allow to set the unit in Twilight mode. Twilight mode let you turn ON and OFF the unit at a specific clock time (including day of the week) and/or at a specific twilight level. The Twilight mode make use of a twilight sensor located on the front panel near unit display.
To know the twilight ambient level value measured from the sensor, scroll the unit menu till MEASURE Mode and select Twilight.
TWILIGHT MODE
Up-DownENTER
Set TWILIGHT MODE
Mode : TWILIGHT Actual : DMX
The unit is switched on and off at the desired twilight level or/and at a specific clock time.
ACTION :
ENTER to CONFIRM
Let you select the desired function in twilight mode.
TWILIGHT Mode ACTION CPR1 LEVEL ON 100 OFF 150: TIME CONDIT INCLUSIVE DAY Mon START 22:00 TIME ON 10:00
You can choose between: DMX / CPR1 / CPR2 / CPR1&2 / CRNB / CUE 1-9 /
LEVEL ON and OFF : Let you select the desired twilight levels for: Twilight mode ON and OFF.
TIME CONDITION: Four different options are available:
1) INACTIVE Clock time (START) and Time on period (TIME ON), are inactive. In this condition the unit goes ON only if the twilight level is valid
2)COMBINED Clock time (START), Time on period (TIME ON) and Twilight level are active. In this condition, the unit goes ON only if all the parameters are valid.
3)INCLUSIVE Clock time (START), Time on period (TIME ON) and Twilight level are active. In this condition, the unit goes ON also if only one of the paramete is valid.
4)EXCLUSIVE Clock time (START) and Time on period (TIME ON), are active, while Twilight level is inactive. In this condition, the unit goes ON only if Clock time (START) is valid.
ENTER
3)MOVING HEAD SETUP MENU
PAN MIN PAN MAX TILT MIN TILT MAX CALIBRATE PAN CALIBRATE TILT INVERT PAN INVERT TILT SWAP PAN & TILT ENCODER RESET PAN & TILT SPEED PAN & TILT
A001
Menu
Up-Down
MOVING HEAD SETUP
ENTER
Page 19
19
DELTA R
A001
Up-Down
PAN MINIMUM POSITION This menu allow to set the Pan minimum position (Default =000)
Up-Down
PAN MAXIMUM POSITION This menu allow to set Pan maximum position (Default = 255)
Up-Down
TILT MINIMUM POSITION This menu allow to set the Tilt minimum position in degrees (Default =000)
Pan Min
Pan Max
Tilt Min
Menu
Up-Down
MOVING HEAD SETUP
Up-DownENTER
Up-DownENTER
Up-DownENTER
Setting Pan Min
Pan Min : 000
Setting Pan Max
Pan Man : 000
Setting Tilt Min
Tilt Min : 000
ENTER
Range 000-255 Default = 000
Range 255-000 Default = 255
Range 000-255 Default = 000
ENTER
ENTER
ENTER
Up-Down
TILT MAXIMUM POSITION This menu allow to set the Tilt maximum position (Default = 255)
Up-Down
PAN CALIBRATION This menu allow to calibrate Pan home position (Default = 105)
Up-Down
TILT CALIBRATION This menu allow to calibrate Tilt home position (Default = 128)
Tilt Max
Calibrate Pan
Calibrate Tilt
Up-DownENTER
Setting Tilt Max
Range 255-000
ENTER
Default = 255
Tilt Max : 000
Up-DownENTER
Calibrating Pan
Pan : 105
Up-DownENTER
Calibrating Tilt
Tilt : 105
Range 000-255
Range 000-255
ENTER
ENTER
Page 20
20
DELTA R
Up-Down
PAN INVERTION This menu allow to set the Pan movement. Normal or Inverted
Up-Down
TILT INVERTION This menu allow to set the Tilt movement. Normal or Inverted
Up-Down
PAN&TILT SWAP This menu allow to invert the control of Pan with the control of Tilt.
Invert Pan
Invert Tilt
Swap Pan&Tilt
Up-DownENTER
Set PAN INVERTION
Pan movement Normal or Inverted Default = Normal
ENTER
Pan : Normal
Actual Normal
Up-DownENTER
Set TILT INVERTION
Tilt movement Normal or Inverted
ENTER
Default = Normal
Tilt : Normal
Actual Normal
Up-DownENTER
Set Pan/Tilt SWAPPING
Pan control inverted with Tilt control
ENTER
and vice versa
Swap : Normal
Actual Normal
Dfault = Normal
IMPORTANT: (During PAN/TILT MIN,PAN/TILT MAX and PAN/TILT CALIBRATE setting,PAN/TILT INVERT and PAN/TILT SWAP are disabled
Up-Down
ENCODER SETTING This menu allow to enable/disable the auto-repositioning function for Pan and Tilt
Up-Down
PAN&TILT RESET This menu allow to reset Pan and Tilt Motors
Encoder
Reset Pan & Tilt
ENTER
Up-DownENTER
Set Encoder Status
Encoder : Active
Actual Active
Resetting Pan & Tilt
PRESS ENTER To RESET Pan & Tilt
Pan/Tilt auto-repositioning system enabled or disabled Default = Active
Pan &Tilt motors reset
Up-Down
PAN & TILT MAXIMUM SPEED This menu allow to set the maximum speed for Pan & Tilt movement.
Speed Pan & Tilt
Up-DownENTER
Set SPEED MAX P&T
Speed MAX % 100
Pan&Tilt maximum motor speed Selectable between 25-100%
ENTER
ENTER
ENTER
Page 21
4)LED SETUP MENU
COLOUR MODE WHITE BALANCE BOOST DRIVING MIN RGB MAX RGB SMOOT FILTER PWM FREQUENCY
21
DELTA R
Menu
A001
Up-Down
COLOUR MODE This menu allow to select the LED’S colour mode control system between RGB, CMYK or HSV
Up-Down
WHITE BALANCE This menu allow to select the levels for Red,Green and blue obtaining a custom White
Colour Mode
White balance
Up-Down
LED SETUP
Up-DownENTER
Up-DownENTER
Set Colour Mode RGB CMYK HSV
Actual RGB
Setting WHITE RED 255 GREEN 255 BLUE
255
ENTER
RGB Mode (Default) Ch7 = Dimmer / Ch8 = Red Ch9= Green / Ch10= BLue
CMYK Mode Ch7 = Black / Ch8 = Cyan Ch9= Magenta / Ch10= Yellow
HSV Mode Ch7 = Nu / Ch8 = Hue Ch9= Saturation / Ch10= Value
The Custom White can be Recall by setting DMX channel 11 (WHITE) in the range 172-213
ENTER
ENTER
Up-Down
BOOST DRIVING This menu allow to increase the LED’s current from 350mA to 500 mA
Up-Down
RGB MINIMUM VALUES This menu allow to select the minimum levels for Red,Green and blue
Up-Down
RGB MAXIMUM VALUES This menu allow to select the maximum levels for Red,Green and blue
Boost Driving
Min RGB
Max RGB
Up-DownENTER
Setting LED BOOST BOOST Status
Whit BOOST active,the LED’s current is setted to 500mA (30%more gain).
ENTER
Default = Disable
Active
NTC thermal protection active.
Warning TEMPERATURE
PROTECTION ACTIVATED
Up-DownENTER
Setting RGB Min
These settings have priority on Master Dimmer (DMX channel 7)
ENTER
Min RED : 000 Min GREEN : 000 Min BLUE
Up-DownENTER
Setting RGB Max
: 000
These settings have priority on Master Dimmer (DMX channel 7)
ENTER
Max RED : 000 Max GREEN: 000 Max BLUE
: 000
Page 22
22
DELTA R
Up-Down
SMOOTH FILTER VALUE This menu allow to select the value of the delay( in millisecons) for RGB channels reaction to DMX or Program variation. 001=2.5 ms delay (Fast response) 100=250 ms delay (Slow response)
Up-Down
PWM FREQUENCY VALUE This menu allow to adjust the PWM frequency value (Hz) in order to reduce flickering in the process of your camera recordings
Smooth Filter
PWM frequency
5)DIPLAY SETUP MENU
CONTRAST FLIP DISPLAY SCREEN SAVER
Up-DownENTER
Set Smooth Filter
Filter Value: 010
Range = 001 / 100 Default = 10 001 = 2.5mS (Istant response to DMX
ENTER
variation) 100 = 250mS (Smooth response to
ENTER to CONFIRM
DMX variation)
Up-DownENTER
Set PWM Frequency
427 Hz 1000 Hz 2000 Hz 4000 Hz 6000 Hz Actual 427 Hz
5 different PWM frequencies available. Default = 427 Hz
ENTER
Menu
A001
Up-Down
DISPLAY CONTRAST This menu allow to select display’s contrast level.
Up-Down
DISPLAY FLIP This menu allow to reverse display's reading depending on the mounting position (On the ground or suspended).
Up-Down
SCREEN SAVER This menu allow to activate the screen saver.
Contrast
Flip Display
Screen saver
Up-Down
DISPLAY SETUP MENU
Up-DownENTER
Up-DownENTER
Contrast 7
0 1 2 3 4 5 6 7 8 9
Flip Select
A
Up-DownENTER
SCREEN SAVER SETTING
Screen Type None
Screen Time (sec):005
ENTER
Range = 0-9
Default = On the ground
Screen saver selectable between None (default) and Blank. Screen saver activating time selectable between 005 / 180 seconds
ENTER
ENTER
ENTER
Page 23
6)MEASURE MENU
LIFE DMX VOLTAGE TEMPERATURE TWILIGHT
23
DELTA R
Menu
A001
Up-Down
LIFE TIME This menu show the total UNIT LIFE TIME (reset not possible) and the RGB life
TIME (reset possible)
Life
Up-Down
MEASURE MENU
Up-DownENTER
Measure Life
Delta R Total LIFE
Days Hours Min Sec
1 19 47 55
UP/DW Change Measure
Measure Life
Delta R RED LIFE
Days Hours Min Sec
0 5 22 30
UP/DW Change Measure
Measure Life
Delta R GREEN LIFE
ENTER
Total Unit Life Time Reset not possible
To resed Red life time,keep pushed Enter button for more than 5 seconds
To resed Green life time,keep pushed Enter button for more than 5 seconds
ENTER
ENTER
ENTER
Days Hours Min Sec
0 4 37 15
UP/DW Change Measure
Measure Life
Delta R BLUE LIFE
Days Hours Min Sec
0 4 06 53
UP/DW Change Measure
To resed Blue life time,keep pushed Enter button for more than 5 seconds
ENTER
Page 24
24
DELTA R
Up-Down
DMX This menu show the DMX channel levels
Up-Down
VOLTAGE This menu show the different Voltage levels for every electronic circuit inside the unit
Up-Down
TEMPERATURE This menu show the NTC sensor temperature.
Dmx
Voltage
Temperature
Up-DownENTER
Measure DMX Start Channels Values
DMX channel levels as received from DMX line
ENTER
001 000 000 000 000 005 000 000 000 000 009 000 000 000 000 013 000 000 000 000
Up-DownENTER
Measure VOLTAGE
All the values are espressed in Volt
ENTER
V Motor 36,9 V Power 160,5 V Internal 17,6 V Oled 13,2
Up-DownENTER
LED’s temperature monitor
ENTER
Measure TEMPERATURE
Celsius 20,5
Up-Down
TWILIGHT This menu show the twilight level.
Twilight
Up-DownENTER
Measure TWILIGHT
Light sensor Twilight level (Located on the front panel of the
ENTER
unit)
Value : 0314
Page 25
25
DELTA R
9- OPENING UP THE PROJECTOR HOUSING:
It is possible to inspect the inside of the projector by removing the covers as shown below.
Attention: REMOVE MAINS POWER PRIOR TO ACCESSING THE PROJECTOR'S INTERNAL COMPONENTS.
Proceed as per the pictures below
9.1- Arms
9.2- Base
Remove these two screws on both arm sides
Remove the 12 screws located on the base
Page 26
26
10- CHANGHING THE LENSES
Delta R Full Color
Optical Lenses set can be interchanged by users. Three different models are available: (spot / medium /wide) Lenses set spot (cod. 03.LK.008) Lenses set medium (cod. 03.LK.001) Lenses set wide (cod. 03.LK.002)
To change the lenses set, proceed as per the pictures below
DELTA R
Remove these 12 screws on both sides of the rear head assembly
Remove the top head cover
Remove these 8 screws and change the panel
ATTENTION: Never touch LEDs and Lensens with hands
Page 27
27
10- CHANGHING THE LENSES
Delta R Triled
Optical Lenses set can be interchanged by users. Three different models are available: (spot / medium /wide) Lenses set spot (cod. 03.LK.008) Lenses set medium (cod. 03.LK.001) Lenses set wide (cod. 03.LK.002)
To change the lenses set, proceed as per the pictures below
DELTA R
Remove these 12 screws on both sides of the rear head assembly
Remove the top head cover
Remove these 6 screws and change the panel
ATTENTION: Never touch LEDs and Lensens with hands
Page 28
28
DELTA R
11- PERIODIC CLEANING:
Front lenses Glass
The dust can reduce the luminous output substantially. Regularly clean the front lenses glass using a soft cotton cloth, dampened with a specialist glasses cleaning solution.
12- PERIODIC CONTROLS:
Mechanical parts:
Periodically check all mechanical parts and the gaskets, replacing them if necessary.
Electrical components:
Check all electrical components for correct earthing and proper attachment of all connectors, refastening if necessary.
Fuse replacement:
Locate the fuse, which protect the electronics, in the base of the DELTA R. Using a multimeter, test the condition of the fuse, replacing it with one of equivalent type if necessary.
Attention: Disconnect mains power prior to removing the projector housing.
Page 29
29
13- DMX PROTOCOL
15 CHANNELS MODE
1 PAN msb 320°
2 PAN lsb 3 TILT msb 180° 4 TILT lsb 5 SPEED MOVEMENT 6 SHUTTER 7 DIMMER 8 RED 9 GREEN 10 BLUE 11 WHITE (Preprogrammed white at different color temperature) 12 CTC 13 COLOURS MACRO 14 FUNCTIONS 15 RESET
DMX CHANNEL
DMX CHANNEL
DMX CHANNEL
DMX CHANNEL
DMX CHANNEL
1
Parameter: PAN msb
2
Parameter: PAN lsb
3
Parameter: TILT msb
4
Parameter: TILT lsb
5
Parameter: MOVEMENT SPEED
DELTA R
DMX range
Value
0-10
11-255
DMX CHANNEL
DMX range
Value
0-9 10-19 20-29 30-119
120-149 150-179 180-204 205-229 230-244 245-255
(degrees)
Move
range
Mode Option Function
Standard
Vector mode from fast to slow
Mid point
DMX value
5
6
Mid point
DMX value
Parameter: SHUTTER
Move
range
(degrees)
5 14 24
192 218
238
250
Mode Option Function
Black-out
Open
Black-out
Strobe at variable speed(from slow to fast)
Pulse open at variable speed(from slow to fast) Pulse close at variable speed(from slow to fast)
Random Strobe (Master and RGB active)
Random Strobe (Full)
PAn&Tilt movement in Black-out
Open
Page 30
DMX CHANNEL
DMX range
Value
0-255
7
Mid point
DMX value
30
Parameter: DIMMER NOTE: IN CMYK MODE Ch7 = BLACK
Move
range
Mode Option Function
DELTA R
(degrees)
Proportional dimmer
DMX CHANNEL
DMX range
Value
0-255 Proportional colour
DMX CHANNEL
DMX range
Value
0-255 Proportional colour
DMX CHANNEL
DMX range
Value
0-255 Proportional colour
Mid point
DMX value
Mid point
DMX value
Mid point
DMX value
Parameter: RED NOTE: IN CMYK MODE Ch8 = CYAN
8
IN HSV MODE Ch8 = HUE
Move
range
Mode Option Function
(degrees)
Parameter: GREEN NOTE: IN CMYK MODE Ch9 = MAGENTA
9
IN HSV MODE Ch9 = SATURATION
Move
range
Mode Option Function
(degrees)
Parameter: BLUE NOTE: IN CMYK MODE Ch10 = YELLOW
10
IN HSV MODE Ch10 = VALUE
Move
range
Mode Option Function
(degrees)
DMX CHANNEL
DMX range Mid point
Value DMX value
0-43 21 44-85 86-127
11
Parameter: WHITE (Pre-programmed White at diff. color temperature)
66 105
Move
range
(degrees)
Mode Option Function
No Function
Full (Red-Green-Blue at Full)
White DTS
IF CHANNEL 14 (FUNCTIONS) = CUSTOM WHITE RECALL (Dmx range value 0 - 79)
128-171 172-213
214-255
150
192
234
White Balance(White Balance programmed on Unit’s Menu)
Custom White Recall
White CTC (Channel 12 CTC enabled Linear color temp. Correction: 3000K-7000K)
IF CHANNEL 14 (FUNCTIONS) = CUSTOM WHITE CREATE (Dmx range value 80 - 160)
128-171 172-213
214-255
150
192
234
Custom White Create (RGB levels selectable by DMX)
White Balance(White Balance programmed on Unit’s Menu)
White CTC (Channel 12 CTC enabled Linear color temp. Correction: 3000K-7000K)
Page 31
31
DMX CHANNEL
DMX range Mid point
Value DMX value
12
Parameter: CTC (Color temperature correction)
Move
range
(degrees)
Mode Option Function
IF CHANNEL 11 (White) = WHITE CTC (Dmx range value 214 - 255)
0-255
Linear color temp. Correction: 0 = 3000K / 128 = 5500K / 255 = 7000K
IF CHANNEL 11 (White) = NO FUNCTION (Dmx range value 0 - 43)
0-255
DMX CHANNEL
DMX range
Value
13
Parameter: COLOUR MACROS
Mid point
DMX value
Smooth RGB linear Hue correction
Move
range
(degrees)
Mode Option Function
0-14 15-29 30-44 45-59 60-74 75-89 90-104
105-119
120-134
135-149 150-164 165-179
180-194
195-209
210-225 226-239 240-255
DELTA R
No Function Macro 1 Macro 2 Macro 3
Macro
Macro 4 Macro
Macro 5 Macro
Macro 6 Macro
Macro 7 Macro
Macro 8 Macro
Macro 9
Macro
Macro 10 Macro
Macro 11 Macro
Macro 12
Macro
Macro 13 Macro
Macro 14 Macro
Macro 15 Macro 16
DMX CHANNEL
DMX range
Value
0-79
80-160
161-255
DMX CHANNEL
DMX range
Value
0-15
16-255
Mid point
DMX value
Mid point
DMX value
14
Parameter: FUNCTIONS (Recall,Create and Store the Custom white)
Move
range
(degrees)
Custom White Recall (Enable CH 11 for Custom white Recall)
Mode Option Function
Custom White Create (Enable CH 11 for Custom white Creation)
15
Parameter: RESET (Pan&Tilt Reset)
Move
range
(degrees)
8
120
Custom White Store (Store the Custom White created )
Mode Option Function
No Functions
Pan&Tilt Reset
Page 32
The information contained in this publication has been carefully prepared and checked. However, no responsibility will be taken for any errors. All rights are reserved and this document cannot be copied, photocopied or reproduced, in part or completely, without prior written consent from D.T.S. D.T.S. reserves the right to make any aesthetic, functional or design modifications to any of its products without prior notice. D.T.S. assumes no responsibility for the use or application of the products or circuits described herein.
MADE IN ITALY
*0517I069*
*0517I069*
D.T.S. Illuminazione s.r.l - Via Fagnano Selve 10-12-14 47843 - Misano Adriatico (RN) Italy
Tel. +39 0541 611131 Fax +39 0541 611111 info@dts-lighting.it www.dts-lighting.it