DSPPA MP9813D Owner's Manual

Page 1
MP9813D
INDIRECT SPEAKER SELECTOR
OWNERS MANUAL
Before operating, please read this manual completely.
FEATURES
l 2CH inputs, 10CH outputs. l All call button. l The channel will be switched to input B automatically while alarming.
Page 2
* * Indirect Speaker Selector
MP9813D
1
FRONT PANEL
REAR PANEL & CONNECTIONS
*ALARM IN to be connected to fire center
l 1-10 Live Terminals of CH1-CH10 respectively l 14-25 COM
1 2 3 4 5 6 7 8 9 10 11 12 13
14 15 ,16 ,17 18 19 ,20 21, 22 23 ,24 ,25
1 2 3 4
1 Power switch. (1 is power on and the power LED is on ) 2 Power indicator. 3 Distributor. 4 All call button.
Power Amp. A
MP series
for BGM
Power Amp. B
MP series
for EMC
ALM OUTPUT to
Timer / Siren Device
Emergency from FIRE center*
Guangzhou DSPPA Audio Co., Ltd.
Page 3
* * Indirect Speaker Selector
MP9813D
2
OPERATION
1. Make BGM signal input from A terminal while EMC signal input from B terminal on the rear panel.
We also can make A, B together with short circuit if there is none of BGM amplifier.
2. Press down any Distributor key to switch on channels which you want.
3. Click All call button with its LED lit and all Switch indicators lit. In this case, all Switching keys
are no use. Click All call button again and its LED gone off, In this case, all Switching keys are use.
4. Pin 1-10 of ALARM INport are live terminals of CH1-CH10 respectively while pin 14-25 are
com. Every channel will be switch to B while alarm signal (short circuit signal) is fed to ALARM IN.
5. An grounded Alarm signal will be send out from“ALARM OUT”while any alarm signal
appears on“ALARM IN.
SPECIFICATIONS
Channels 10, switch able Input capacity
70-100V 10A
Channel capacity
70-100V 5A/CH
ALM
0/+24V, 0short circuitis Valid Protection AC fuse Power Requirement AC 220-240V/50-60Hz Outer Packing Size( mm)
L×W×H530×440×195
Unit Size (mm)
L×W×H484×365×88 Gross weight 8.3kg Net weight 6.5kg
Specifications are subject to be changed without notice.
CAUTION
When the Power switcher is off, please pull out the power cord from the socket.
Please keep the equipment out of water.
To reduce the risk of electric shock, do not remove the cover.
No user parts inside. Refer servicing to qualified service personnel.
Guangzhou DSPPA Audio Co., Ltd.
Page 4
* * 广播分区器
MP9813D
3
MP9813D
广播分区器
使用说明
欢迎惠顾。您对本产品之选用显示了您的专业眼光。使用前请仔细阅读本说明书。
性能特点
l 2 路输入(A B) 10 通道输出。 l 有强行插入功能。 l 便捷的全开全关功能控制。 l 当有警报信号输入时,相应通道自动切换到通道 B
Page 5
* * 广播分区器
MP9813D
4
前面板
后面板及连接
*ALARM IN 同消防中心连接
l 1-10 热端,分别对应于 CH1-CH10 l 14-25 公共端
1 2 3 4 5 6 7 8 9 10 11 12 13
14 15 ,16 ,17 18 19 ,20 21, 22 23 ,24 ,25
1 2 3 4
1 电源开关(按下 1 为电源接通状态且电源指示等亮) 2 电源指示 3 分区选择键 4 全开全关控制开关
A 功放
MP series
(背景音乐)
B 功放
MP series
(紧急广播)
警报信号输出
警报信号 来自消防中心*
Guangzhou DSPPA Audio Co., Ltd.
Page 6
* * 广播分区器
MP9813D
5
使用方法
1. 背景音乐信号由后面板 A ,紧急广播信号由 B (如无紧急广播专用功放, 可AB 子并接)。
2. 任一分区选择键,对应分区的应分区的指示亮且选通分区。
3. 按下“全开全关控制键,其相对应的指示灯点亮,其他十个分区控制键的指示灯也同时亮,
其他十个分区控制键不能控制分区。当再次按下“全开全关控制键,对应的指示灯熄
其他十个分区控制键控制分区了。
4. 警报输入口ALARM IN”(连接)的14-25 端为公共地线;第 1 号10 号端分别 对应管理 CH1-CH10 十个任一子接地相当于告警,相应通道扬声器乃自动强切到 B 输
5. 警报输入口ALARM IN”任一子有警报信号输时,报警信号输出ALARM OUT
即有报警信号输出,用于启动处待机状态的定时器以及激发警报信号发生器。
注意:如现未按下任何分区选择键,而该分区的指示亮且选通分区选通的情况,可能是警
报输入口ALARM IN”有短路激活信号(不一是从防中心来的报警信号)。
性能规格
道数 10, 可任意选通 输入容量
70-100V , 10A
输出容量 每个道 70-100V , 5A 警报信号 0/+24V, 0V(短路有效
保护 AC 保险丝
电源
AC 220-240V/50-60Hz
外包装尺寸mm (长××高)530×440×195 尺寸mm (长××高)484×365×88 毛重
8.3kg
净重
6.5kg
性能规格如有改变恕另行
注 意
设备的电源开关”状态时,并未电源断开,为使用
设备时,请电源线插头拔插座
设备不能遭受水滴或水溅不能满水的花瓶之类的物品放置在设备上。
勿随打开器盖板,以防电。必要专业书之专业人员进行修
Guangzhou DSPPA Audio Co., Ltd.