Public Address Device
DSP1501 Phased Array Column Speaker
Operation Manual
Welcome to use our Public Address System. For better use of this equipment, please read this manual carefully before use.
Page 2
Contents
The subassemblies of Phased-array Column Speaker..................................................1
1. Product Description......................................................................................................2
2. Functions.......................................................................................................................2
3. Description of Remote Controller Keypad..................................................................2
4. Installation Diagram......................................................................................................3
5. Description of Back Ports.............................................................................................3
6. Description of Remote Controller Keypad..................................................................4
7. Operating Instructions..................................................................................................4
8. Specifications................................................................................................................6
Page 3
* Public Address System Operating Instructions
1
The subassemblies of Phased-array Column Speaker:
Infrared remote controller
Speaker fixing screws x 2
RCA connector
XLR connector - male XLR connector - female
Page 4
* Public Address System Operating Instructions
2
1. Product Description
The phased-array column speaker is a new type of public address device. By applying the electronic and digital signal processing (DSP) technologies, it can simulate the directivity of different shapes of column speakers, while the inherent performances of the phased-array column speaker will not be affected, e.g. rated power, range of frequency response and max. sound pressure level.
With DSP technologies, we may operate from the remote controller to change the directivity of speaker system at some extent. This is suitable for public address in a hall where the building acoustics is poor (especially long reverberation time). This product is most suitable for the hardware (speaker, DSP processor) of the public address system in sports venues (where the volume of space is large, the building acoustics is poor, the reverberation time is long and the sound is muddy), that it can be combined with special software to make the controllable sound cover useful area (auditoria, etc) correctly and prevent it from diffusion to useless area (e.g. ceiling, door or window). In this case, it can reduce the investment in material of acoustic decorations in venues and decrease the energy loss caused by public address system. This leads to reduced investment in both the acoustic decorations and public address system in the sports venue.
2. Functions
l Acoustically simulate the column speakers of different shapes, e.g. inclined, concave, convex
and more complicates shapes.
l Active column speaker with built-in digital signal processor and digital power amplifier, so that it
is no need for driving of external power amplifier.
l This unit has AUX signal input, AUX signal output and constant voltage power signal input (70V
or 100V).
l Volume, tone and other parameters of the column speaker can be adjustable. l The LED screen on the lower part of the unit can display different parameters and messages. l Operate from infrared remote controller. l Compact size, easy installation and high electro-acoustic sensitivity.
3. Description of Remote Controller Keypad
Key Function Operation Remarks
Power ON/OFF One touch of this key slightly It takes approx. 5s for startup.
Sound ON or
OFF
One touch of this key slightly
EQ
Equalization adjustment
One touch slightly to enter into equalization interface. See Page 4 for operating methods.
14-section equalization; amplitude ±12dB
AN+
Increase directivity angle
One touch to increase by 1°. Hold down for 3s to increase continuously
Max. angle: +45°
AN-
Decrease directivity angle
One touch to decrease by 1°. Hold down for 3s to decrease continuously
Min. angle: -45°
V+ Increase volume
One touch to increase by 1 level. Hold down for 3s to increase continuously
Max. volume: 32 levels
V-
Decrease volume
One touch to decrease by 1 level. Hold down for 3s to decrease continuously
Min. value: 0
FOCUS+ Focus backward
Every touch to move 1m backward. Hold down for 3s to move continuously
Nearest: -30m
FOCUS- Focus forward
Every touch to move 1m forward. Hold down for 3s to move continuously
Farthest: +30m
S Key Select sensitivity
One touch to view sensitivity; hold down to select value of sensitivity
0dB, -6dB and -10dB available for selection
Page 5
* Public Address System Operating Instructions
3
4. Installation Diagram:
1. Select a proper position on the surface where the column speaker is to be installed, and fix two screws ø8mm. As shown on right, mount the bracket and fix the column speaker.
2. Connect the wire correctly as described in
Section 5. Check if the column speaker is secure and confirm that the connection is correct. Then, plug the power cable of column speaker into AC socket.
5. Description of Back Ports
70-100V constant-
voltage
audio input port
300mV AUX audio input port
From PA amplifier
From audio source equipment
300mV AUX audio output port
Output to other PA device
Test port
Test port
Power fuse holder
AC Power inlet
Page 6
* Public Address System Operating Instructions
4
6. Description of Remote Controller Keypad
7. Operating Instructions
The phased-array column speaker is operated by infrared remote controller. The operation of remote controller is effective when it operates within 180°in front of the sound column.
1. Switch on the unit (Firstly, the UDE will appear before entering this
interface).
2. Adjust the volume
Press V+ or “V- (Max. volume: 32 levels; Min. volume: 0).
3. Equalization Adjustment
Press EQ (Range of adjustable frequency: 80Hz-20kHz)
Press V+ or V- to move left and right for selection of frequency band (14 bands in total).
Press AN+ or AN- to adjust the amplitude of selected frequency band (Adjustable amplitude:
Infrared remote controller
1. Mute key
2. Sensitivity selection key (Sensitivity)
3. Volume setting key (V+) for increase and (V-) for decrease
4. Directivity setting key (AN+) for increase and (AN-) for decrease
5. Shift key for equalization setting (EQ)
6. Focus adjustment key (FOCUS+, -)
7. Treble adjustment key (TREBLE+, -)
8. Bass adjustment key (BASS+, -)
9. On/OFF key (Note: The ON/OFF key can only switch off the current play status, but it cannot switch off the main power of the column speaker). To switch off the power supply, please remove the power plug from the socket).
Startup Interface
Volume Interface
EQ Interface
Page 7
* Public Address System Operating Instructions
5
±12dB). After finishing the adjustment, press EQ to exit.
4. Directivity Adjustment
Press AN+ or AN- (Increase or decrease the directivity angle. The
range of adjustment is as shown below).
5. Adjust Focus Press FOCUS+ or FOCUS- “+” indicates forward movement of focus. Max.
forward movement: 99m;
-” indicates backward movement of focus. Max.
backward movement: 99m.
6. Mute
Press Press again
7 Select Input Sensitivity Value
Press S Hold down Sagain
With S key held down, the three sensitivity values, i.e. 00dBV, -06dBV and -10dBV will be displayed alternatively. When the desired sensitivity value appears, please release S key, so that this sensitivity value will be effected.
8. Energy-Saved Operation If there is no operation to the column speaker within 30s, the screen will automatically enter into screen
Directivity Interface
Indication for Adjustable Range of Directivity
Focus Interface
Mute
Interface
Volume Interface
Enter
Sensitivity
Interface to View
Select
Sensitivit
0º
+45º -45º
Page 8
* Public Address System Operating Instructions
6
saver status, in which case only a red spot is shown on the screen. Under screen saver status, you may press any key from remote controller to enter into associated operating interface.
8. Specifications
Model
DSP1501
Rated power
100W
Input sensitivity
00dBV, -06dBV, -10dBV /70-100V
Range of directivity angle
±45º
Size (mm) (L×W×H)153.5×110×1270 Weight (mm)
13kg
Specifications are subject to change without notice.