The 2 Amp, 3 Amp and 5 Amp
Battery Chargers have been
designed to be permanently
connected to a battery, keeping it
charged to maximum capacity.
The chargers can be either
mounted via DIN rail or to the
chassis, using the fixing holes that
are built into the case. The chargers
stylish design includes an LED
indicator on the front that shows
when the charger is in a normal or
overload condition.
AC
3
AM
155
T
B
AT
T
P
&
5
AM
,
DSE915
&
DSE
ERY
P
C
H
O
PT
I
O
N
S
The chargers will continue to
operate during cranking and
running. All chargers can accept
multiple AC voltage connections.
The DSE battery chargers are
expertly designed using high-grade
components and capacitors
allowing the units to function more
efficiently, providing a longer and
more reliable life-span than other
chargers in their class. Their inbuilt robustness makes them ideal
for the rigours of a wide variety of
markets including heavy and light
industrial environments.
9255
AR
G
E
R
0,
S
ENVIRONMENTAL TESTING STANDARDS
ELECTRO-MAGNETIC COMPATIBILITY
S EN 61000-6-2
B
EMC Generic Immunity Standard for
the Industrial Environment
BS EN 61000-6-4
EMC Generic Emission Standard for
the Industrial Environment
TEMPERATURE
BS EN 60068-2-1
Ab/Ae Cold Test -30 oC
BS EN 60068-2-2
Bb/Be Dry Heat +55 oC
VIBRATION
BS EN 60068-2-6
Ten sweeps in each of three
major axes
Hz to 8 Hz @ +/-7.5 mm,
5
8 Hz to 500 Hz @ 2 gn
HUMIDITY
BS EN 60068-2-30
Db Damp Heat Cyclic 20/55 oC
95% RH 48 Hours
@
S EN 60068-2-78
B
ab Damp Heat Static 40
C
@ 93% RH 48 Hours
HOCK
S
S EN 60068-2-27
B
hree shocks in each of three major axes
T
5 gn in 11 mS
1
o
C
FEATURE LIST TO SUIT A WIDE VARIETY
OF APPLICATIONS
CHARGE OUTPUTAC POWER SUPPLY
COMPATIBLE WITH ALL DSE MODULES
DSE9000
CHARGE BOOST INPUT
(Not available for DSE9150 & DSE9155)
11
N/C VOLT FREE CHARGE FAIL OUTPUT
(Not available for DSE9150)
1ph
N
ISSUE 5
DSE
D
S
E
9
1
3
0
D
S
E9
C
OM
P
2
A
M
P,
S
E
R
U
AT
E
F
ADVANCED FEATURES
Constant current- maximum
•
current available during charge
recovery phase
• Constant voltage
• Chargers automatically return to
float mode when charging is
complete
• Makes the chargers ideal for all
battery types
• Reverse polarity protection,
short circuit protection and
current limiting
• Automatic recovery after the
removal of fault conditions
1
5
5
A
C
T
B
AT
TE
3
A
M
P
&
5
A
M
,
D
S
E9
&
P
D
S
R
Y
C
H
O
P
T
I
O
NS
• Boosts and equalises cell
charge improving battery
performance and life
• Simple boost connection using
on-board terminals
• Once the battery is fully
charged the chargers switch to
Eco-Power to save energy
A
R
1
E9
GE
5
0
,
2
5
5
R
S
DSE9130 - 5 A 12 V
DSE9155 - 2 A 30 V
DSE9255 - 5 A 24 V
KEY BENEFITS
• Suitable for a wide range of
• No moving parts for longer
• Switched mode design
• Charge fail output
• Minimum 80% efficiency
• Multiple modules can be linked
DSE9150 - 3 A 12 V
battery types
battery charger life
throughout full operating range
together to provide larger current
output
SPECIFICATION
AC SUPPLY
FREQUENCY RANGE
48 Hz to 64 Hz
DSE9130 & DSE9255 VOLTAGE RANGE
90 V to 305 V (L-N)
DSE9150 VOLTAGE RANGE
90 V to 265 V (L-N)
DSE9155 VOLTAGE RANGE
85 V to 265 V (L-N)
DC OUTPUT
DSE9130 OUTPUT
5 A DC 12 V DC at 13.7 V DC
DSE9150 OUTPUT
3 A DC 12 V DC at 13.7 V DC
DSE9155 OUTPUT
2 A DC 30 V DC at 34.3 V DC
DSE9255 OUTPUT
5 A DC 24 V DC at 27.4 V DV
RIPPLE AND NOISE
<1%
EFFICIENCY
>80%
REGULATION
LINE
<0.001% Vo
LOAD
1% Vo
PROTECTIONS
Short Circuit
Over Voltage
Over Current
Reverse Polarity
DIMENSIONS
DSE9150 DIMENSIONS
108 mm x 101 mm x 49 mm
4.2” x 4” x 1.9”
WEIGHT
0.16 kg
DSE9130, DSE9155 & DSE9255
DIMENSIONS
136 mm x 140 mm x 63 mm
5.4” x 5.5” x 2.5”
WEIGHT
0.5 kg
OPERATING TEMPERATURE RANGE
-30 °C to +55 °C
-22 °F to +122 °F
STORAGE TEMPERATURE RANGE
-40oC to +85oC
-40 °F to +185 °F
®
RELATED MATERIALS
TITLEPART NO’S
DSE9000 Series Installation Instructions 053-049
DSE9000 Series Operator Manual 057-085
Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change
the details shown on this data sheet without prior notice. The contents are intended for guidance only.
9.1 Corrected specs for 9140
10 Removed all DSE9400 series chargers, added DSE9470
11 Added new DSE9400 series Chargers
12 Changes to add DSE9150 12V 3A
13
Typeface : The typeface used in this document is Arial. Care should be taken not to mistake the upper
case letter I with the numeral 1. The numeral 1 has a top serif to avoid this confusion.
Updated DSE9470 and DSE9480 to -003 (MKII) and added DSE9472MKII and
DSE9481 MKII
057-159 DSE9400 Series Battery Charger Configuration Suite Manual
5
Introduction
2 INTRODUCTION
NOTE: This document DOES NOT contain details of the ‘obsolete’ DSE9210 and DSE9240
battery chargers. For further details of these units, please contact Deep Sea Electronics.
This document details the installation requirements of the DSE9000 series range of battery chargers.
The manual forms part of the product and should be kept for the entire life of the product. If the
product is passed or supplied to another party, ensure that this document is passed to them for
reference purposes.
This is not a controlled document. You will not be automatically informed of updates. Any future
updates of this document will be added to the DSE website at www.deepseaplc.com.
The DSE9000 series modules are intended for mounting within a customer enclosure or panel (DIN
rail mounting or fastened by screws/bolts).
DSE also supply some of the battery chargers as completed units, factory mounted into enclosures for
wall or floor mounting.
The DSE9000 series chargers fulfill the most common functions required of a charger in the
generating set industry. Combining protected outputs, intelligent charging and power supply operation
with a robust enclosure.
6
Specifications
3 SPECIFICATIONS
3.1 PART NUMBERING
3.1.1 DSE9100 CHASSIS MOUNT BATTERY CHARGERS
9130 - 001 - 00
Product type
DSE9130 12V 5A
DSE9140 12V 10A
DSE9150 12V 2A
DSE9150 12V 3A
DSE9155 30V 2A
9130
9140
9150
9150
9155
For 9 or 18 cell NICAD batteries*
For 10 or 20 cell NICAD batteries*
Specify required float voltage on ordering**
For lead acid batteries
12V charger s et to 13.7V
24V charger s et to 27.4V
12V charger s et to 13.0V
24V charger s et to 26.0V
12V charger s et to 14.5V
24V charger s et to 29.0V
For other battery types*
Hardware revisions
First version hardware
Variant
00
01
02
03
001
NOTE: For descriptions of other Hardware Revisions, please contact
support@deepseaplc.com
NOTE: The DSE9150 12V 2A is now obsolete, replaced with DSE9150 12V 3A.
NOTE: The DSE9150 12V 3A only available in Variant -00 (13.7V for lead acid batteries)
NOTE: For variant 03 (For other battery types), the float voltage can be adjusted between
12.5V and 15V for DSE9130 12V 5A chargers (25V - 30V for DSE9250 24V 3.7A chargers). This
change must be made at the DSE factory. Ensure the correct variant (and float voltage if
applicable) is specified on ordering. Consult your battery manufacturer for further details of
required float voltage.
7
Specifications
3.1.2 DSE9200 CHASSIS MOUNT BATTERY CHARGERS
9130 - 001 - 00
Product type
DSE9250 24V 3.7A
DSE9255 24V 5A
9250
9255
For 9 or 18 cell NICAD batteries*
DSE9260 24V 10A
9260
For 10 or 20 cell NICAD batteries*
Specify required float voltage on ordering**
For lead acid batteries
12V charger s et to 13.7V
24V charger s et to 27.4V
12V charger s et to 13.0V
24V charger s et to 26.0V
12V charger s et to 14.5V
24V charger s et to 29.0V
For other battery types*
Hardware revisions
First version hardware
Variant
00
01
02
03
001
NOTE: For descriptions of other Hardware Revisions, please contact
support@deepseaplc.com
NOTE: - The DSE9250 battery charger is now obsolete, details provided for information
only.
NOTE: For variant 03 (For other battery types), the float voltage can be adjusted between
12.5V and 15V for DSE9130 12V 5A chargers (25V - 30V for DSE9250 24V 3.7A chargers). This
change must be made at the DSE factory. Ensure the correct variant (and float voltage if
applicable) is specified on ordering. Consult your battery manufacturer for further details of
required float voltage.
8
Specifications
3.1.3 DSE9400 MKII SERIES CHASSIS MOUNT BATTERY CHARGERS
9470 - 001 - 00
Product type
DSE9470 12/24V 10A
DSE9472 24V/12V 5A
DSE9480 24V/12V 10A 9480
DSE9481 24V/12V 5A 9481
NOTE: For descriptions of other Hardware Revisions, please contact
support@deepseaplc.com
9470
9472
First v ersion hardware 001
Variant
Standard
Hardware revisions
00
NOTE: For hardware versions 003 and above, voltage and current levels can be user
configured via DSE Configuration Suite PC Software.
Part number 9470-001-00 is fixed at 24V 10A.
Part number 9480-001-00 is fixed at 12V 10A.
NOTE: DSE9400 series battery chargers are customer configurable via the DSE
Configuration Suite PC Software.
For further details, you are referred to DSE Publication: 057-159 DSE9400 Series Battery
NOTE: The DSE907 / DSE908 Industrial / Cabinet Mounted Battery Chargers are now
obsolete, replaced by DSE9460 / DSE9461 Enclosed Battery Chargers.
See the preceeding page for details of part numbering of chassis mounted battery chargers.
Industrial / Cabinet mounted battery chargers are 9000 series battery chargers factory fitted into wall
mounted enclosures. For details see the section entitled Dimensions and Mounting elsewhere in
this document.
When ordering Industrial / Cabinet mounted battery chargers, ensure you specify the type of batteries
that are to be charged. If you do not specify this, the chargers will be preset to charge Lead Acid type
batteries.
NOTE: Check the DSE9400 Series de-rating curves which can be found else where in this
manual for more information.
DSE9400 Series
PT1000
11
Specifications
Communication
Specification
USB Port
•
3.3 COMMUNICATION PORT USAGE
(DSE9400 series
only)
USB2.0 Device for connection to PC running DSE Configuration Suite
Max distance 6m (20 feet)
Isolated
Data connection 2 wire + common
RS485 Serial
Port
(DSE9400 series
only)
Half Duplex
Data direction control for Transmit (by s/w protocol)
Max Baud Rate 19200
External termination required (120Ω)
Max common mode offset 70V (on board protection transorb)
Max distance 1.2km (¾ mile)
3.3.1 USB CONNECTION
The USB port is provided to give a simple means of connection between a PC and the DSE9400
series battery charger. Using the DSE Configuration Suite Software, the operator is then configure
and monitor the state of the battery charger.
To connect a DSE9400 series battery charger to a PC by USB, the following items are required:
• DSE9400 series battery charger
• DSE Configuration Suite Software
(Supplied on configuration suite software CD or available from
www.deepseaplc.com).
USB cable Type A to Type B.
(This is the same cable as often used between a PC and a USB
printer)
DSE can supply this cable if required :
PC Configuration interface lead (USB type A – type B) DSE Part
No 016-125
NOTE: - Refer to DSE9400 Series Battery Charger PC Software Configuration Manual for
further details on configuring and monitoring.
12
Specifications
3.3.2 RS485
The RS485 port on the DSE9400 series battery chargers has two uses.
DSE2541 remote battery charger display modules
connects to the DSE9400 MKII Series battery
charger RS485 terminals.
This provides battery charger operating status, alarm
indication, instrumentation and control over the
DSE9400 MKII Series battery charger.
For further information please contact
sales@deepseaplc.com.
3.3.2.2 MODBUS RTU
RS485 is used for point-to-point cable connection of more than one device (maximum 32 devices)
and allows for connection to PCs, PLCs and Building Management Systems (to name just a few
devices).
Using the DSE Configuration Suite PC Software, Configurable Gencomm is used to map
instrumentation to modbus registers.
One advantage of the RS485 interface is the large distance specification (1.2km) when using Belden
9841 (or equivalent) cable. This allows for a large distance between the DSE9400 series battery
charger and a PC running the DSE Configuration Suite software. The operator is then able to view the
various operating parameters.
NOTE: - For distances up to 6m (8yds) the USB connection method is more suitable and
provides for a lower cost alternative to RS485 (which is more suited to longer distance
connections).
13
Specifications
3.3.2.3 OPTIONS FOR CONNECTION TO PCS
• Brainboxes PM154 PCMCIA RS485 card (for laptops PCs)
Set to ‘Half Duplex, Autogating” with ‘CTS True’ set to ‘enabled’
• Brainboxes VX-023 ExpressCard 1 Port RS422/485 (for laptops and
nettop PCs)
• Brainboxes UC320 PCI Velocity RS485 card (for desktop PCs)
Set to ‘Half Duplex, Autogating” with ‘CTS True’ set to ‘enabled’
Output Voltage (12 V DC battery) 12.5V 13.7V 15.0V Specify float voltage on ordering.
Output Charging Current (A) 0A 5A 5.5A
Current limit threshold (A) 5A 5.3A 5.5A
Recovery from current limit (A) 5A
Full load AC input current (A) 1.5A With output at 13.7V DC
AC Input Inrush (10ms) current (A) 20A
DSE9130 Efficiency Curve at 5A
0.92
0.9
0.88
0.86
0.84
Efficiency (%)
0.82
0.8
85110230260
Input Voltage (V)
15
Specifications
Parameter
Min Nominal
Max Comments
85
110
230
260
3.5.2 DSE9140 12V 10A
Output Voltage (12 V DC Battery) 12V 13.7V 15V
Output Charging Current (A) 10A 10A 11A
Current limit threshold (A) 10A 11A
Recovery from current limit (A) 10A 11A
Full load AC input current (A) 3.1A At Vin=85V, Vo=13.7V, Io=10Am p
Full load AC input current (A) 1.3A At Vin=230V, Vo=13.7V Io=10Amp
AC Input Inrush (10ms) current (A) 60A
DSE9140 Efficiency Curve at 10A
0.87
0.86
0.85
0.84
0.83
0.82
0.81
Efficiency (%)
0.8
0.79
0.78
Input Voltage (V)
16
Specifications
Parameter
Min Nominal
Max Comments
3.5.3 DSE9150 12V 2A
NOTE: This device is no longer available, replaced by DSE9150 12V 3A. See overleaf for
updated specifications.
Output Voltage (12 V DC Battery) 12.5V 13.7V 13.7V Float voltage not adjustable
Output Charging Current (A) 0A 2A 2.5A
Current limit threshold (A) 2A 2.3A 2.5A
Recovery from current limit (A) 2A
Full load AC input current (A) 0.7A With output at 13.7V DC
AC Input Inrush (10ms) current (A) 10A
DSE9150 Efficiency Curve at 2A
90
88
86
84
82
80
Efficiency (%)
78
76
74
85110230250
Input Voltage (V)
17
Specifications
Parameter
Min Nominal
Max Comments
3.5.4 DSE9150 12V 3A
NOTE: This device has replaced DSE9150 12V 2A. See previous page for specifications of
the earlier model.
Output Voltage (12 V DC Battery) 12.5V 13.7V 13.7V Float voltage not adjustable
Output Charging Current (A) 0A 3A 3.5A
Current limit threshold (A) 3A 3.2A 3.5A
Recovery from current limit (A) 3A
Full load AC input current (A) 0.7A With output at 13.7V DC
AC Input Inrush (10ms) current (A) 10A
DSE9153 Efficiency Curve at 3A
0.87
0.86
0.85
0.84
0.83
0.82
Efficiency (%)
0.81
0.80
0.79
110230265
Input Voltage (V)
18
Specifications
Parameter
Min Nominal
Max Comments
3.5.5 DSE9155 30V 2A
Output Voltage (30 V DC Battery) 28.0V 34.3V 34.5
Output Charging Current (A) 0A 2.2A 3A
Current limit threshold (A) 2A 2.2A 3A
Recovery from current limit (A) 2A
Full load AC input current (A) 2A
AC Input Inrush (10ms) current (A) 30A
DSE9155 Efficiency Curve at 2A
0.94
0.92
0.9
0.88
0.86
Efficiency (%)
0.84
0.82
0.8
0.78
85110230260
Input Voltage (V)
19
Loading...
+ 48 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.