DSECONTROL
MONITORING
WITH
INTELLIGENCE.
®
DSE5310 & DSE5320
AUTO START & AUTO MAINS FAILURE CONTROL MODULES (ELECTRONIC ENGINE ENABLED)
DSE5310
The DSE5310 is an Automatic
Start Control Module designed to
automatically start and stop diesel
and gas generating sets that
include non electronic and
electronic engines. The module
also provides advanced engine
monitoring and protection features.
The module has the ability to
monitor under speed, over speed,
charge failure, emergency stop,
low oil pressure, high engine
temperature, fail to start, fail to
stop, under/over generator volts,
over current, under/over generator
frequency, low/high DC battery
volts, low fuel alarm and loss of the
speed sensing signal. The module
displays fault conditions on the
LCD display and via the LED
indicators on the front.
The DSE5320 is an Automatic Mains
(utility) Failure Control Module and
includes all the features of the
DSE5310 plus the abilityto monitor
a mains (utility) supply. Upon
detection of a mains (utility) failure
the module automatically starts the
generating set. Once the mains
(utility) power has been restored the
module instructs the generating set
to stop.
Both modules include RS232 or
RS485 communication capabilities
for linking to a PC, sending SMS
messages and interfacing with new
and existing building management
systems.
FEATURES
• Automatic start
• Automatic load transfer
• Automatic mains (utility) failure
detection (DSE5320 only)
• Electronic engine connection
• RS232 or RS485 remote
communications
• Modbus RTU
• Analogue inputs
• Audible alarm indication
• Back-lit character & 4-line text
LCD display
• Configurable alarms & timers
• Configurable auxiliary inputs
• Digital inputs
• Emergency stop functions
• Engine history event log
• Engine exercise mode
• Engine protection
• Front panel mounting
• Front panel programming
• Full engine diagnostics
• Generator operating status
warning
• LCD alarm indication
• LED alarm indication
• Manual start
• Multiple language options
• PC configurable
• PIN protected programming
• Power save mode
• Remote monitoring
• SMS messaging
BENEFITS
• Full integration into new & existing
building management systems
• Full engine protection &
instrumentation without the need
for additional senders (Electronic
engines only)
• In-built engine diagnostics
removes the requirement for
service equipment
DSE5320
• License free PC software
• Remote module control and
monitoring using comprehensive
DSE PC software
• Modules improve the life cycle of
engine starter motors
• On-site and remote module
configuration
• Modules send SMS messages to
engineers to notify specific engine
problems (GSM Modem and SIM
Card required)
• User-friendly set-up and button
layout
OPERATION
The modules are operated using the
front STOP, AUTO and MANUAL
push buttons. The DSE5320 also
includes a TEST button. An
additional push button allows the
user to scroll through the LCD
display.
CONFIGURATION
The modules can be configured
using the front panel buttons or the
DSE810 interface and PC software.
SPECIFICATION
DC SUPPLY
8 V to 35 V continuous
RANKING DROPOUTS
C
Able to survive 0V for 50mS, providing the
supply was at least 10V before dropout and
supply recovers to 5V
AUXILIARY OUTPUTS 1-3
5A DC at supply voltage
UXILIARY OUTPUTS4 & 5
A
(DSE5320 only)
A AC rated volt-free relay
8
MAXIMUM OPERATING CURRENT
400mA at 12V, 200mA at 24V
TANDBY CURRENT
S
when in auto)
(
230mA at 12V, 120mA at 24V
SLEEP MODE CURRENT
70mA at 12V, 45mA at 24V
MODULE DIMENSIONS (WxH)
240mm x 172mm
9.4” x 6.8”
ANEL CUT-OUT (WxH)
P
20mm x 160mm
2
8.7” x 6.3”
MAXIMUM PANEL THICKNESS
8mm
0.3”
ELECTRONIC ENGINE CAPABILITY

ENVIRONMENTAL TESTING
STANDARDS
ELECTRO MAGNETIC CAPABILITY
BS EN 61000-6-2
EMC Generic Emission Standard for the
ndustrial Environment
I
BS EN 61000-6-4
MC Generic Emission Standard for the
E
Industrial Environment
LECTRICAL SAFETY
E
S EN 60950
B
Safety of Information Technology Equipment,
ncluding Electrical Business Equipment
i
TEMPERATURE
BS EN 60068-2-2
est Ab to +70
T
Test Ab to -30
VIBRATION
S EN 60068-2-6
B
Ten sweeps in each of three major axes
Hz to 8Hz @ +/-7.5mm, 8Hz to 500Hz @ 2gn
5
HUMIDITY
BS 2011 part 2.1 60068-2-30
Test Cb Ob Cyclic
3% RH @ 40
9
SHOCK
BS EN 60068-2-27
Three shocks in each of three major axes
5gn in 11mS
1
o
60067-2-2 Hot
C
o
C 60068-2-1 Cold
o
for 48 hours
C
COMMUNICATIONS
The DSE5310 & DSE5320 have a number of different communication
capabilities.
SMS Messaging
When the module detects an alarm condition, it has the ability to send an
SMS message to a dedicated mobile number, notifying an engineer of the
problem. (GSM Modem and SIM Card required)
Remote Communications
When the module detects an alarm condition, it dials out using suitable
modem, to a PC notifying the user of the exact alarm condition.
Building Management
The module has been designed to be integrated into new and existing
building management systems.
PC Software
The module has the ability to be configured and monitored from a remote
PC, using the DSE810 interface.
EVENT LOG
The module includes a comprehensive event log that shows the 30 most
recent alarm conditions and the date and time that they occurred. This
function assists the user when fault finding and maintaining a generating set.
INSTRUMENTATION
The modules provide advanced metering facilities, displaying the information on
the LCD display. The information can be accessed using the display scroll push
buttons located next to the LCD display.
EXPANSION MODULE
COMPATIBILITY
DSE157 Relay Input Expansion
Module
DSE545 & DSE 548 Remote
Annunciation Expansion Module
DSE130 Input Expansion Module
ELECTRONIC ENGINE
COMPATABILITY
• Cummins
• Deutz
• John Deere
• MTU
• Perkins
• Scania
• Volvo
• Generic
• Plus additional manufacturers
5310 5320
eneratorInstruments
G
Volts, Hz, Amps, kW, kVA, Pf,Kwh, kVAr,
kVArh, KVAh
Engine Instruments
RPM, Oil Pressure, Coolant Temperature,
Hours Run, Charging Voltage, Battery Volts.
Electronic Engines
Enhanced Instrumentation and Engine ECU
diagnostics via electronic engine interface.
Generator Instruments
Volts, Hz, Amps, kW, kVA, Pf,Kwh, kVAr,
kVArh, KVAh
Engine Instruments
RPM, Oil Pressure, Coolant Temperature,
Hours Run, Charging Voltage, Battery Volts.
Electronic Engines
Enhanced instrumentation and Engine ECU
diagnostics via electronic engine interface.
Mains/UtilityInstruments
Volts, Frequency, Amps (optional when
CT’s are fitted load side of the line)
RELATED MATERIALS
TITLE PART NO’S
DSE5310 Installation Instructions 053-012
DSE5320 Installation Instructions 053-014
DSE5310 Manual 057-013
DSE5320 Manual 057-014
DSE157 Data Sheet 055-045
DSE545 & DSE548 Data Sheet 055-049
DSE130 Data Sheet 055-047
52/53xx Software Manual 057-006
CAN & DSE wiring guide 057-004

DSE5310 & DSE5320
2 AMP
FUSES
MG
2 AMP
FUSES
BATTERY
-VE
+VE
FUEL
CRANK
CHG ALT
OIL
WATER
FUEL
SENDER COMMON
IMPUTS
PLANT +VE
MAINS LOADING
RELAY
GENERATOR
LOADING RELAY
O
UTPUTS CANBUS
COM
H
L
ELECTRICAL INTERLOCK
ELECTRICAL INTERLOCK
LOAD
MODULE 5310/5320
BATTERY NEGATIVE MUST BE GROUNDED
TERMINALS SUITABLE FOR 22-16 AWG (0.6mm - 1.3mm )
FIELD WIRING
TIGHTENING TORQUE = 0.8Nm (7lb-in)
NOTE 1
THESE GROUND CONNECTIONS MUST BE ON THE
ENGINE BLOCK, AND MUST BE TO THE SENDER BODIES.
THE GROUND WIRE TO TERMINAL 47 MUST NOT BE
USED TO PROVIDE A GROUND CONNECTION TO ANY
OTHER DEVICE
P810
157
NOTE 2. 120 R TERMINATING RESISTOR
MAY BE REQUIRED EXTERNALLY SEE ENGINE
MANUFACTURERS LITERATURE
NOTE 1
C
T1 CT2 CT3 COM
3
9 40 41 42 35 36 37 38 29 30 27 28 31 32 33 34 16 17 18
12 3 45944 45 46 47 10 11 12 13 14 15 678 20 21 22
L1 L2 L3 N L1 L2 L3 N
CTs MUST BE 5 AMP
SECONDARY
P1 P2
S1 S2
BUS VOLTS
GEN VOLTSGEN CURRENT
EMERGENCY STOP
LOW OIL PRESSURE
HIGH COOLANT TEMP
FUEL LEVEL SERVER
USER CONFIGURABLE -VE INPUT 1
USER CONFIGURABLE -VE INPUT 2
USER CONFIGURABLE -VE INPUT 3
USER CONFIGURABLE -VE INPUT 4
USER CONFIGURABLE -VE INPUT 5
USER CONFIGURABLE -VE INPUT 6
USER CONFIGURABLE +VE INPUT
USER CONFIGURABLE +VE INPUT
USER CONFIGURABLE +VE INPUT
UPTO 32 AMPS
FUSE
MIN 2 AMP MAX 20 AMP
ANIT-SURGE FUSE
BATTERY
FUELFUEL
WL
CRANK
CHARGE
ALT
L
1
L2
L3
N
FROM
MAINS
FROM
GENERATOR
DSE5320 ONLY
L
1
L2
L3
N
®

DEEP SEA ELECTRONICS PLC
Highfield House
TELEPHONE
+44 (0)1723 890099
Hunmanby Industrial Estate
Hunmanby, North Yorkshire
YO14 0PH England
Registered in England & Wales No.01319649 VAT No.316923457
DEEP SEA ELECTRONICS INC
3230 Williams Avenue
FACSIMILE
+44 (0)1723 893303
TELEPHONE
+1 (815) 316 8706
Rockford
IL 61101-2668 USA
FACSIMILE
+1 (815) 316 8708
EMAIL
sales@deepseaplc.com
WEBSITE
www.deepseaplc.com
EMAIL
sales@deepseausa.com
WEBSITE
www.deepseausa.com
®
YOUR LOCAL DISTRIBUTOR.
DEEP SEA ELECTRONICS PLC maintains a policy of continuous development and reserves the right to
change the details shown on this data sheet without prior notice. The contents are intendedfor guidance only.
This data sheet is printed on 9lives 55 Silk, which is produced with 55% recycled fibre
from both pre and post-consumer sources, together with 45% virgin ECF fibre.
055-038/02/08 (2)