Dry Air MAX Force, VAF Series Ventilation Manual

MAX Force
Ventilation Manual
313 North Oak Street • Burlington, WA 98233 • USA
Tel: 360-755-9176 • Fax: 360-755-9236
Toll Free U.S. & Canada: 1-888-755-9176
info@dryairtech.com
• www.dryairtech.com
Congratulations on your purchase of a new VAF series fan by Dry Air Technology, Inc. This Vane Axial Fan has been designed to offer you the reliability, durability and portability you need for the toughest job.
Each of our units is carefully engineered to meet the needs of your industry whether it is industrial, marine, restoration, rental or balloon. Our products are designed specifically for your application to ensure the highest level of performance. All of us at Dry Air Technology value our clients and uphold our mission to provide you with the best customer service possible. Please read this owner’s manual carefully to ensure that you get the most from your unit.
SAFETY INFORMATION CAUTION!
Unit operates on alternating current: 110/120 volt, 60 HZ Do not operate your VAF series fan with a cut or frayed power cord. Do not unplug your unit by
pulling on its cord. Grasp the plug firmly and pull it out of the wall socket or power receptacle. The plug has a safety ground pin installed that must not be removed. If the pin is damaged or missing, have the power cord replaced at once. Visually inspect the power cord before each use. Ignoring these safety precautions may result in a fire or an electric shock.
Never operate electrical equipment in standing water. There is a shock hazard. Never drop the unit. Sudden and severe impact may result in damage to internal components. Your VAF fan should never be operated with the safety grills removed. Personal injury may result. Drop cloths or other loose fabrics can be drawn against the unit thereby restricting airflow. This
condition may cause the unit to overheat. Keep the air inlet clear of any obstructions. Save the shipping carton in case your VAF fan must be returned for repair. This unit should never be serviced or cleaned while it is plugged into a live electrical power source.
WARNING: Ignoring these safety precautions may result in serious personal injury.
Vane Axial Fan
MAX FORCE
OPERATING INSTRUCTIONS The unit as packaged is ready to be put into service. If you have a 220V model, attach the
appropriate plug for your region. Inspect the unit completely for any shipping damage. Place the unit on the ground or on a very
stable platform. Plug the unit into a grounded alternating current circuit and switch the unit on.
MAINTENANCE Warning
Disconnect the unit from the power supply before cleaning or servicing. Before each use the unit should be inspected for damage, clogged inlet or outlet, or any excess
buildup of foreign material. When the unit is first turned on, check for excessive vibration, which could indicate a major problem. If the unit vibrates, have a service technician inspect the unit for the problem.
SPECIFICATIONS FOR MAX FORCE
VOLTAGE 110/120V FREQUENCY 60 HZ MOTOR 1 HP CURRENT 8.6 AMPS RPM 3450 CFM 4000 HEIGHT 22” WIDTH 21” LENGTH 15 ½” WEIGHT 39 lbs*
*Weight does not include stand.