Dry Air MAX Force, VAF Series Ventilation Manual

MAX Force
Ventilation Manual
313 North Oak Street • Burlington, WA 98233 • USA
Tel: 360-755-9176 • Fax: 360-755-9236
Toll Free U.S. & Canada: 1-888-755-9176
info@dryairtech.com
• www.dryairtech.com
Congratulations on your purchase of a new VAF series fan by Dry Air Technology, Inc. This Vane Axial Fan has been designed to offer you the reliability, durability and portability you need for the toughest job.
Each of our units is carefully engineered to meet the needs of your industry whether it is industrial, marine, restoration, rental or balloon. Our products are designed specifically for your application to ensure the highest level of performance. All of us at Dry Air Technology value our clients and uphold our mission to provide you with the best customer service possible. Please read this owner’s manual carefully to ensure that you get the most from your unit.
SAFETY INFORMATION CAUTION!
Unit operates on alternating current: 110/120 volt, 60 HZ Do not operate your VAF series fan with a cut or frayed power cord. Do not unplug your unit by
pulling on its cord. Grasp the plug firmly and pull it out of the wall socket or power receptacle. The plug has a safety ground pin installed that must not be removed. If the pin is damaged or missing, have the power cord replaced at once. Visually inspect the power cord before each use. Ignoring these safety precautions may result in a fire or an electric shock.
Never operate electrical equipment in standing water. There is a shock hazard. Never drop the unit. Sudden and severe impact may result in damage to internal components. Your VAF fan should never be operated with the safety grills removed. Personal injury may result. Drop cloths or other loose fabrics can be drawn against the unit thereby restricting airflow. This
condition may cause the unit to overheat. Keep the air inlet clear of any obstructions. Save the shipping carton in case your VAF fan must be returned for repair. This unit should never be serviced or cleaned while it is plugged into a live electrical power source.
WARNING: Ignoring these safety precautions may result in serious personal injury.
Vane Axial Fan
MAX FORCE
OPERATING INSTRUCTIONS The unit as packaged is ready to be put into service. If you have a 220V model, attach the
appropriate plug for your region. Inspect the unit completely for any shipping damage. Place the unit on the ground or on a very
stable platform. Plug the unit into a grounded alternating current circuit and switch the unit on.
MAINTENANCE Warning
Disconnect the unit from the power supply before cleaning or servicing. Before each use the unit should be inspected for damage, clogged inlet or outlet, or any excess
buildup of foreign material. When the unit is first turned on, check for excessive vibration, which could indicate a major problem. If the unit vibrates, have a service technician inspect the unit for the problem.
SPECIFICATIONS FOR MAX FORCE
VOLTAGE 110/120V FREQUENCY 60 HZ MOTOR 1 HP CURRENT 8.6 AMPS RPM 3450 CFM 4000 HEIGHT 22” WIDTH 21” LENGTH 15 ½” WEIGHT 39 lbs*
*Weight does not include stand.
Trouble Shooting
Problem Cause Solution
Unit will not run. 1. No power to unit.
2. Switch not on.
3. Switch is faulty.
4. Faulty/broken cord or motor wire.
Unit runs but fan makes loud scraping noise.
Unit runs but vibrates excessively.
Unit runs but fan does not turn.
Unit runs briefly, then shuts off on overload.
1. Unit has been severely jolted causing fan to rub against housing.
2. Unit has been severely jolted causing housing to deform.
1. Severe jolt has bent motor shaft causing unit to be out of balance.
2. Fan blade damaged.
3. Dirt build up on one side of fan blade.
1. Fan is jammed against housing.
2. Capacitor wire has broken/come loose, capacitor has failed.
3. Housing has been damaged such that it presses on fan blade.
1. Motor bearings are failing or motor has developed an internal electrical fault.
2. Intake grill and/or exhaust grill is obstructed.
3. Excessive duct length.
1. Plug unit in. Check circuit breaker.
2. Place in “ON” position.
3. Replace switch.
4. Perform continuity check, using volt/amp meter. Repair/replace faulty broken wire.
1. Remove motor and replace damaged motor mounts.
2. Replace fan blade.
1. Remove and replace motor.
2. Replace blade if necessary.
3. Clean fan blade.
1. Remove motor and replace damaged motor mounts. Replace fan blade if necessary.
2.Repair/replace wires/capacitor as necessary.
3. Replace housing/unit as necessary.
1. Replace motor.
2. Remove obstruction.
3.Reduce duct length to recommended maximum.
313 North Oak Street Burlington, WA 98233 USA
Tel: 1-360-755-9176 Fax: 1-360-755-9236
Toll Free U.S. & Canada: 1-888-755-9176
info@dryairtech.com
• www.dryairtech.com
Parts List
Item Qty Part Number Description
1 1 AF-00C-P4N30434 VAF 16E Shell Red 2 1 AF-00M-N1A10203 1HP 110V 48 Frame Motor 3 1 AF-02M-P4A10234 16” Fan Blade 30* 4 4 GN-00C-RNN10006 Tempest/Axial Feet, P/N 2544 5 1 AF-00E-PNA10227 Capacitor, 370 VAC/40UF 6 1 AF-00C-M5A10381 16” Wire Form Grill 7 6 AF-00F-R4A10194 E6-32 Stnd. Well Nut 8 6 GN-00F-S3AN0198 6/32 x 1” SS Bolt for Well Nut 9 6 FL-00F-S5AN0025 #6 Flat Washer, 18-8, SS MS-806 10 5 AF-00C-M1NN0403 Vane Motor Mount 10 AF-00F-S2AN0041 8-32 x ¼” HWH Vane to Motor 1 AF-00C-M2A10393 Motor Bracket 2 AF-00C-P6A10384 Duct Connector Ring
Parts List
Item Qty Part Number Description
1 1 AF-00C-M3A10359 Switch Plate, VAF 12E/16R 2 1 AF-00C-R6A10360 Gasket, Switch Plate, VAF 12/16 3A 1 AF-00E-PNN10015 Strain Relief-LQ TIGHT 3B 1 AF-00E-PNN10015 Strain Relief-LQ TIGHT 4 1 CF-00E-N4A10004 Power cord 20’ 16/3 SJT-WA CEE 5 1 GN-00C-R3NN0335 Cover, Rocker Switch 6 1 GN-00E-P3B10218 ON/OFF Rocker Switch, BLK
Dry Air Technology 10 Year Limited Warranty
Axial and Centrifugal Air Flow Products
Warrantor: Dry Air Technology, 313 North Oak Street, Burlington, WA 98233. Telephone: 888-755-
9176, local: 360-755-9176, fax: 360-755-9236.
Who Is Covered: This warranty extends to the original end-user of axial and centrifugal air flow
devices manufactured by Dry Air Technology, and may not be assigned or transferred.
Warranty Period: The term of the warranty coverage from the date of purchase is:
10 years on the cabinet, chassis and housing 1 year on parts, labor and reasonable shipping costs, excluding filters and accessories.
Warranty Coverage: Dry Air Technology warrants that, for one year, axial and centrifugal air flow
devices manufactured by Dry Air Technology will operate free from defects in material or workmanship, or Dry Air Technology, at its option, will repair or replace the defective part(s), free of charge.
Dry Air Technology further warrants that for a period of ten (10) years, the cabinet, chassis and housing of axial and centrifugal air flow devices manufactured by Dry Air Technology, will be free from defects in material or workmanship, or Dry Air Technology, at its option, will repair or replace the def ective part(s), provided that all labor and shipping costs for the defective part(s) shall be borne by the end-user.
This warranty does not cover any defect, malfunction, etc. resulting from misuse, abuse, lack of normal care, corrosion from chemicals, freezing, tampering, modification, unauthorized or improper repair or operation, accident, acts of nature or any other cause beyond Dry Air Technology’s reasonable control.
End-User Responsibilities: Warranty service must be performed by a firm or individual authorized
by Dry Air Technology. If the end-user is unable to locate or obtain warranty service from an authorized firm or individual, he should contact Dry Air Technology at the abov e location , which will arrange for covered warranty service. All covered warranty service will be performed during normal business hours.
Limitations and Exclusions: If any part of a axial or centrifugal air flow device manufactured by
Dry Air Technology is repaired or replaced, the new part shall be warranted only for t he remainder of the original warranty period of the air flow device (but all warranties will be extended by the period of time, if any, that the Dry Air Technology air flow device is out of service while waiting for covered warranty service).
UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE DRY AIR TECHNOLOGY AIR FLOW DEVICE OR ANY PART THEREOF, ALL OTHER WARRANTIES IMPLIED BY LAW, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL ALSO EXPIRE. ALL WARRANTIES MADE BY DRY AIR TECHNOLOGY ARE SET FORTH HEREIN, AND NO CLAIM MAY BE MADE AGAINST DRY AIR TECHNOLOGY BASED ON ANY ORAL WARRANTY. IN NO EVENT SHALL DRY AIR TECHNOLOGY, IN CONNECTION WITH THE SALE, OPERATION, REPAIR OR REPLACEMENT OF ANY DRY AIR TECHNOLOGY AIR FLOW DEVICE OR PART THEREOF BE LIABLE UNDER ANY LEGAL THEORY FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION WATER DAMAGE (THE END­USER SHOULD TAKE PRECAUTIONS AGAINST SAME), LOST PROFITS, DELAY, OR LOSS OF USE OR DAMAGE TO ANY REAL OR PERSONAL PROPERTY. Some states do not allow limitations on how long an implied warranty lasts, and some do not allow the exclusion or limitation of incidental or consequential damages, so one or both of these limitations may not apply to you.
Legal Rights: This warranty gives you specific legal rights, and you may also have other rights which
vary from state to state.
DRY AIR TECHNOLOGY, BURLINGTON, WASHINGTON
Loading...