Owner’s Manual & Safety Instructions
Save This Manual Keep this manual for the safety warnings and precautions, assembly,
operating, inspection, maintenance and cleaning procedures. Write the product’s serial number in the
back of the manual near the assembly diagram (or month and year of purchase if product has no number).
Keep this manual and the receipt in a safe and dry place for future reference. 19b
Do not return
pump to the store.
Call 1-844-416-9141
Visit our website at: http://www.harborfreight.com
Email our technical support at: productsupport@harborfreight.com
When unpacking, make sure that the product is intact
and undamaged. If any parts are missing or broken,
please call 1-888-866-5797 as soon as possible.
Copyright© 2016 by Harbor Freight Tools®. All rights reserved.
No portion of this manual or any artwork contained herein may be reproduced in
any shape or form without the express written consent of Harbor Freight Tools.
Diagrams within this manual may not be drawn proportionally. Due to continuing
improvements, actual product may differ slightly from the product described herein.
To ol s re q u ir e d fo r as s e mb l y a n d s e r vi c e m a y n o t b e in c l ud e d .
Read this material before using this product.
Failure to do so can result in serious injury.
SAVE THIS MANUAL.
Before start-up, note the following:
The pump must be connected to a GFCI protected plug which has been installed according
to regulations. The plug must have a supply voltage of 120 VAC at 60 Hz.
CAUTION
This pump has been evaluated for use with water only.
WARNING
IMPORTANT! For your own safety –
before starting to run the pump, please have
the following items checked by an expert:
1. Risk of electric shock – This pump is supplied
with a grounding conductor and grounding-type
attachment plug. To reduce the risk of electric shock,
be certain that it is connected only to a properly
grounded, grounding-type receptacle.
2. Risk of electric shock – This pump has not been
investigated for use in swimming pool areas.
3. The electrical connections must be
protected from moisture.
4. If there is danger of flooding, the electrical
connections must be taken to higher ground.
5. Circulation of caustic fluids, as well as the circulation
of abrasive materials, must be avoided at all costs.
6. The pump must be protected from frost.
7. The pump must be protected from running dry.
8. Access by children should also be
prevented with appropriate measures.
9. To prevent death from electric shock,
pump must be connected only to a GFCI
protected outlet.
10. Do not pump flammable materials. Motor
brushes may spark and cause
explosions.
11. Do not use an extension cord with this item.
12. People with pacemakers should consult their
physician(s) before use. Electromagnetic fields in
close proximity to heart pacemaker could cause
pacemaker interference or pacemaker failure.
13. The warnings, precautions, and instructions
discussed in this instruction manual cannot cover all
possible conditions and situations that may occur.
It must be understood by the operator that
common sense and caution are factors
which cannot be built into this product, but
must be supplied by the operator.
Fluid Type
The Pump is designed for use with water with a maximum temperature of 77° F (25°C). Do not use the pump
for other fluids, especially not fuels, cleaning fluids, or other chemical products.
Page 2 For technical questions, please call 1-888-866-5797. Item 63317
Specifications
Horse Power 1/10 HP
Electrical Rating 120VAC / 60Hz / 2A
Power Cord Length 6’
Maximum Flow @ 0’ 320 GPH
Maximum Head lift @ 0 Flow 42′
Discharge Port 3/4″ Garden Hose Thread
Installation
The pump must be installed in a stationary position with either:
a. A fixed pipeline or
b. A flexible hose pipe.
Please note!
1. Do not install the pump by suspending it
unsupported from its delivery pipe or power cord.
The pump must be suspended from the handle
or be placed on the bottom of the basin.
To ensure that the pump works properly, keep the
bottom free from sludge and dirt of all kinds.
Power Supply
1. The pump is equipped with a shock-proof plug
according to regulations. The pump is designed to be
connected to 120 VAC, 60 Hz GFCI protected socket.
2. Make sure that the socket is sufficiently
secured and is in excellent condition.
3. Depending on application, a separate
flow switch (not included) may be needed
between the plug and the outlet.
Areas of use
1. This pump is designed to pump water only.
2. If the water level sinks too low, any sludge in the
basin will dry out and stop the pump from starting.
To help ensure the pump will start as required,
check the pump regularly with start-up tests.
4. WARNING: To prevent death from electric
shock, pump must be connected only to
a GFCI protected outlet.
WARNING! If the power cord or plug is damaged,
do not use the pump. The power cord or plug
may only be repaired by a certified electrician.
3. This pump should NOT be used for:
2. This pump is designed to be used for:
General purpose removal or transfer of clear water.
Continuous run, fountain/pond water features.
Removing water from swimming pools or
spas. Septic or sewage systems.
4. This pump can also be used to transfer water
(e.g. household, farming, plumbing).
Page 3For technical questions, please call 1-888-866-5797.Item 63317