Drucker Diagnostics 653ES User Manual

Replacement Parts:
Part No. Description
7724177 Rubber Foot 7751068 Switch, lid safety 7735049 Motor, 1/30 H.P., 115 V.A.C. permanent split capacitor 7729009 Capacitor, 5uF, 250V A.C. 7717046 Electronic timing and locking board, w/display 7751043 Circuit Breaker 7760002 Power cord 7714101 Pawl, latch, lid 7714103 Knob, latch, lid 7712316 Lid 7724071 Hinge, friction 7732018 Seal, lid gasket 7713030 2-Place 100mm Tube Carrier 7786048 Horizontal Rotor
Available Accessories:
1” Tube cushion
p/n 1525
0.25” Tube cushion
p/n 9150
P/N 7711014
WARRANTY:
The Drucker Company warranties that this centrifuge is free
from defects in workmanship and parts for 2 years.
Made in the USA by
200 Shadylane Drive • Philipsburg, PA 16866
Phone: 814-342-6205 or 814-692-7661 • Fax: 814-692-7662 • www.druckercompany.com
Operator’s Manual
Rev. B
Model 653ES • Laboratory Centrifuge
Table of Contents
Model Description pg. 2 Supplied Equipment pg. 2 Features pg. 3 Specications pg. 3 Setup Location and Procedure pg. 4 Front Panel Controls pg. 5 Operation pg. 6 Rotor Removal and Installation pg. 7 Programming Functions pg. 7 Tube Holder Congurations pg. 7,8 Care and Maintenance pg. 9 Troubleshooting pg. 10 Safety, Emergency Lid Removal pg. 11 Calibration and Ground Testing pg. 11 Replacement Parts pg. 12 Available Accessories pg. 12
WARNING: Care should be taken when handling substances that are known to be toxic, radioactive or contaminated with pathogenic microorganisms when using this centrifuge for the safety of both the operator and service personnel. When Risk Group II materials are used, (as identied in the World Health Organization “Laboratory Bio–Safety Manual”), a Bio–Seal should be employed. More than one level of protection must be provided in the case of materials of a higher group. The use of ammable or explosive materials as well as those materials which chemically react vigorously is prohibited.
Model Description:
The Horizon Easy-Spin 12, model 653ES, is a continuous-duty,
electronically-controlled horizontal centrifuge with a lid safety interlock system. The unit is controlled through a push-button interface with a digital time display for precise spin times and ease of use. Samples can be safely viewed through the transparent lid. Entry into the machine is restricted during operation by the safety interlock system.
Safety:
Horizon Lid Safety Switch: The Horizon lid is secured to the top of the
cabinet by a latching knob and pawl system. When the knob is rotated clockwise, the pawl grips the underside of the cabinet opening and prevents the lid from opening. A mechanical stop positions the pawl and prevents it from rotating completely. When rotated to the stop position, the pawl makes contact with a micro–switch mounted underneath the cabinet top. The lid safety switch prevents the centrifuge from operating while the lid is open. An indicator light on the front of the machine will light up when the lid has been latched properly.
Horizon Lid Safety Interlock System: In addition to the Lid Safety Switch, the Horizon has a true “0 RPM” lid locking system. The lid safety interlock system keeps the lid locked at all times, (even during power failure), and requires that the rotor be at rest in order to unlock the lid. The centrifuge will not allow entry into the rotor chamber unless the centrifuge has power and the rotor is stopped. To open the lid, make sure that the centrifuge is plugged in and, with the rotor stopped, press the ‘OPEN / EMERGENCY STOP’ button.
Note: After the centrifuge has started spinning, it may be possible to rotate the lid knob enough to cause the pawl to lose contact with the lid safety switch. If this happens, the centrifuge motor may lose power, but the lid will still remain locked. If the knob is accidentally moved and this situation should occur, rotate the knob fully clockwise to its stop position and the centrifuge will resume operation.
The Horizon models 653ES complies with all requirements of
UL standard 3101–2–20.
Supplied Equipment*:
The following items come standard with each Horizon centrifuge:
1. One (1) horizontal rotor
2. Operator’s manual
3. Six (6) 2-Place 100mm tube carriers
1.
3.
* The rotor and rotor accessories are rated for a rotation frequency of 4,000 RPM.
Page 2
p/n 7786048
p/n 7713030
Operator’s Manual
2.
x 6
Circuit Breaker: The Horizon is protected with a 4 Amp circuit breaker located at the rear of the machine mounted to the base. Any electrical short circuit will cause the breaker to cut power to the machine.
Emergency Lid Removal:
In the event of power failure, it may be impossible to unlock the lid by conventional means. In this case, the lid must be removed to gain entry into the rotor chamber and remove samples. To remove the lid, rst take out the four (4) screws holding the hinge assembly to the cabinet. Slide the lid to the right or left until it is clear to remove it. The centrifuge must be serviced before it can be safely used again. Contact The Drucker Company for further assistance.
Remove these screws on both hinges
Calibration and Earth Ground Testing:
It is recommended that the top speed, ground continuity and line leakage be tested every two years for continued safe operation. Contact The Drucker Company for further information or testing availability.
Page 11