This manual is available for free download on the manufacturer’s web site. It is a
copyrighted document. Re-sale is strictly prohibited. The manufacturer may update this
manual from time to time and cannot be responsible for problems, injuries, or damages
arising out of the use of information contained in any manual obtained from unauthorized
sources.
READ AND KEEP THIS MANUAL FOR REFERENCE
www.drolet.ca
Stove Builder International Inc.
(Quebec) Canada G3A 2H3
Page 2
Eldorado Installation and Operation Manual
THANK YOU FOR CHOOSING THIS DROLET WOOD STOVE
As one of North America’s largest and most respected wood stove and fireplace
manufacturers, Stove Builder International takes pride in the quality and performance of all
its products. We want to help you get maximum satisfaction as you use this product.
In the pages that follow you will find general advice on wood heating, detailed instructions
for safe and effective installation, and guidance on how to get the best performance from
this stove as you build and maintain fires, and maintain your wood heating system.
We recommend that our wood burning hearth products be installed and serviced by
professionals who are certified in the United States by NFI (National Fireplace Institute®) or
in Canada by WETT (Wood Energy Technology Transfer) or in Quebec by APC
(Association des Professionnels du Chauffage).
Congratulations on making a wise purchase.
When this stove is not properly installed, a house fire may result. To reduce the risk
of fire, follow the installation instructions. Contact local building or fire officials
about restrictions and installation inspection requirements in your area.
Please read this entire manual before you install and use your new stove. Failure to
follow instructions may result in property damage, bodily injury, or even death. It is
important that you follow the installations guidelines exactly.
You may need to obtain a building permit for the installation of this stove and the
chimney that it is connected to. Consult your municipal building department or fire
department before installation to determine the need to obtain one. We recommend
that you also inform your home insurance company to find out if the installation will
affect your policy.
REGISTER YOUR WARRANTY ONLINE
To receive full warranty coverage, you will need to show
evidence of the date you purchased your stove. Keep your sales
invoice. We also recommend that you register your warranty
1.1 Summary of Operation and Maintenance Cautions and Warnings
•HOT WHILE IN OPERATION, KEEP CHILDREN, CLOTHING AND FURNITURE AWAY.
CONTACT MAY CAUSE SKIN BURNS. GLOVES MAY BE NEEDED FOR STOVE
OPERATION.
•USING A STOVE WITH CRACKED OR BROKEN COMPONENTS, SUCH AS GLASS OR
FIREBRICKS OR BAFFLES MAY PRODUCE AN UNSAFE CONDITION AND MAY
DAMAGE THE STOVE.
• OPEN THE AIR CONTROL FULLY BEFORE OPENING FIRING DOOR.
• OPERATE ONLY WITH DOOR FULLY CLOSED OR FULLY OPEN WITH FIRE SCREEN IN
PLACE. IF DOOR IS LEFT PARTLY OPEN, GAS AND FLAME MAY BE DRAWN OUT OF
THE OPENING, CREATING RISKS FROM BOTH FIRE AND SMOKE.
•THIS STOVE HAS BEEN TESTED FOR USE WITH AN OPEN DOOR IN CONJUNCTION
WITH A FIRE SCREEN (AC01342, SOLD SEPARATELY). THE DOOR MAY BE OPEN OR
FIRE SCREEN REMOVED ONLY DURING LIGHTING PROCEDURES OR RELOADING.
ALWAYS CLOSE THE DOOR OR PUT BACK THE FIRE SCREEN AFTER IGNITION. DO
NOT LEAVE THE STOVE UNATTENDED WHEN THE DOOR IS OPENED WITH OR
WITHOUT FIRE SCREEN.
•NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL (NAPHTHA), FUEL OIL,
MOTOR OIL, KEROSENE, CHARCOAL LIGHTER FLUID, OR SIMILAR LIQUIDS OR
AEROSOLS TO START OR ‘FRESHEN UP’ A FIRE IN THIS STOVE. KEEP ALL SUCH
LIQUIDS OR AEROSOLS WELL AWAY FROM THE STOVE WHILE IT IS IN USE.
• DO NOT STORE FUEL WITHIN HEATER MINIMUM INSTALLATION CLEARANCES.
• BURN ONLY SEASONED NATURAL FIREWOOD.
• DO NOT BURN:
o GARBAGE OF ANY KIND,
o COAL OR CHARCOAL,
o TREATED, PAINTED OR COATED WOOD,
o PLYWOOD OR PARTICLE BOARD,
o FINE PAPER, COLORED PAPER OR CARDBOARD,
o SALT WATER DRIFTWOOD, OR
o RAILROAD TIES.
• DO NOT ELEVATE THE FIRE BY USING A GRATE IN THIS STOVE.
• THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN
ACCORDANCE WITH THESE INSTRUCTIONS.
6
Page 7
Eldorado Installation and Operation Manual
2 General Information
2.1 Eldorado Specifications
Fuel Type Cordwood
Test Standards (safety) ULC S627, UL 737 and UL 1482
Test Standard (emissions) EPA Method 28 (40 CFR Part 60)
Heating capacity range* 500 to 1500 sq. ft. (46 to 139 m2)
Maximum heat output**
(EPA test fuel)
Maximum heat output**
(natural hardwood fuel)
23 600 BTU/h (6.8 kW/h)
55 000 BTU/h (16.1 kW/h)
Optimum efficiency 75.3 %
Test Standard (efficiency) CSA B415.1
Approximate Burn Time* 5 to 6 hours
Shipping Weight 270 lb (122 kg)
Firebox Volume 1.7 cu.ft. (0.048 m3)
Maximum Log Length 17" east-west***
Flue Outlet Diameter: 6" (150 mm) diameter (vertical)
Baffle Material Vermiculite
* Burn time and heating capacity may vary subject to location in home, chimney draft,
chimney diameter, locality, heat loss factors, climate, fuels and other variables.
** The EPA test fuel is dimensional Douglas fir pieces stapled together into cribs with air
spaces between. We also test using the same procedure except using split hardwood
firewood to reflect real-world heat output. This stove is not intended to operate at its peak
heat output continuously.
*** East-west: through the door you see the sides of the logs; north-south: through the door
you see the ends of the logs.
7
Page 8
Eldorado Installation and Operation Manual
8
Page 9
Eldorado Installation and Operation Manual
2.2 Zone Heating and How to Make it Work for You
Your new Eldorado wood stove is a space heater, which means it is intended to heat the
area it is installed in, as well as spaces that connect to that area, although to a lower
temperature. This is called zone heating and it is an increasingly popular way to heat
homes or spaces within homes.
Zone heating can be used to supplement another heating system by heating a particular
space within a home, such as a basement family room or an addition that lacks another
heat source.
Although the stove may be able to heat the main living areas of your house to an adequate
temperature, we strongly recommend that you also have a conventional oil, gas or electric
heating system to provide back up heating.
Your success with zone heating will depend on several factors, including the correct sizing
and location of the stove, the size, layout and age of your home and your climate zone.
Three-season vacation homes can usually be heated with smaller stoves than houses that
are heated all winter.
2.3 The Benefits of Low Emissions and High Efficiency
The low smoke emissions produced by the special features inside the Eldorado firebox
mean that your household will release up to 90 percent less smoke into the outside
environment than if you used an older conventional stove. But there is more to the
emission control technologies than protecting the environment.
9
Page 10
Eldorado Installation and Operation Manual
The smoke released from wood when it is heated contains about half of the energy content
of the fuel. By burning the wood completely, your stove releases all the heat energy from
the wood instead of wasting it as smoke up the chimney. Also, the features inside the
firebox allow you to reduce the air supply to control heat output, while maintaining clean
and efficient flaming combustion, which boosts the efficient delivery of heat to your home.
The emission control and advanced combustion features of your stove can only work
properly if your fuel is in the correct moisture content range of 15 to 20 percent. See
Section A3.0 of this manual for suggestions on preparing fuelwood and judging its
moisture.
2.4 The SBI Commitment to You and the Environment
The SBI team are committed to protecting the environment, so we do everything we can to
use only materials in our products that will have no lasting negative impact on the
environment.
2.4.1 What is Your New Stove Made Of?
The body of your stove, which is most of its weight, is carbon steel. Should it ever become
necessary many years in the future, almost the entire stove can be recycled into new
products, thus eliminating the need to mine new materials.
The paint coat on your stove is very thin. Its VOC content (Volatile Organic Components)
is very low. VOCs can be responsible for smog, so all the paint used during the
manufacturing process meets the latest air quality requirements with regards to VOC
reduction or elimination.
The air tubes are stainless steel, which can also be recycled.
Vermiculite is used for the baffle. Vermiculite is a mineral. Large commercial mines exist in
China, Russia, South Africa, and Brazil. Potassium silicate is used as binder to form a
rigid board. Vermiculite can withstand temperatures above 2,000 °F. It is not considered
hazardous waste. Disposal at a landfill is recommended.
Lightweight firebrick is made of pumice and cement. Pumice is in fact volcanic rock, a
naturally green product found in the Northwest United States. Disposal at a landfill is
recommended.
The door and glass gaskets are fibreglass which is spun from melted sand. Black gaskets
have been dipped into a solvent-free solution. Disposal at a landfill is recommended.
The door glass is a 5 mm thick ceramic material that contains no toxic chemicals. It is
basically made of raw earth materials such as sand and quartz that are combined in such
a way to form a glass at high temperatures. Ceramic glass will not re-melt in the same
way as normal glass, so it should not be recycled with your regular household products.
Disposal at a landfill is recommended.
10
Page 11
Eldorado Installation and Operation Manual
3 Fuel
3.1 Materials That Should Not be Burned
•
GARBAGE OF ANY KIND,
•
COAL OR CHARCOAL,
•
TREATED, PAINTED OR COATED WOOD,
•
PLYWOOD OR PARTICLE BOARD,
•
FINE PAPER, COLORED PAPER OR CARDBOARD,
•
SALT WATER DRIFTWOOD,
•
MANUFACTURED LOGS CONTAINING WAX OR CHEMICAL ADDITIVES,
•
RAILROAD TIES,
•
LIQUIDS SUCH AS KEROSCENE OR DIESEL FUEL TO START A FIRE.
3.2 How to Prepare or Buy Good Firewood
3.2.1 What is Good Firewood?
Good firewood has been cut to the correct length for the stove, split to a range of sizes and
stacked in the open until its moisture content is reduced to 15 to 20 per cent.
3.2.2 Tree Species
The tree species the firewood is produced from is less important than its moisture content.
The main difference in firewood from various tree species is the density of the wood.
Hardwoods are denser than softwoods. People who live in the coldest regions of North
America usually have only spruce, birch and poplar, other low-density species to burn and
yet they can heat their homes successfully.
Homeowners with access to both hardwood and softwood fuel sometimes use both types
for different purposes. For example, softer woods make good fuel for relatively mild
weather in spring and fall because they light quickly and produce less heat Softwoods are
not as dense as hardwoods so a given volume of wood contains less energy. Using
softwoods avoids overheating the house, which can be a common problem with wood
heating in moderate weather. Harder woods are best for colder winter weather when more
heat and longer burn cycles are desirable.
Note that hardwood trees like oak, maple, ash and beech are slower growing and longer
lived than softer woods like poplar and birch. That makes hardwood trees more valuable.
The advice that only hardwoods are good to burn is outdated. Old, leaky cast iron stoves
wouldn’t hold a fire overnight unless they were fed large pieces of hardwood. That is no
longer true. You can successfully heat your home by using the less desirable tree species
and give the forest a break at the same time.
11
Page 12
Eldorado Installation and Operation Manual
3.2.3 Log Length
Logs should be cut about 1” (25 mm) shorter than the firebox so they fit in easily. Pieces
that are even slightly too long make loading the stove very difficult. The most common
standard length of firewood is 16” (400 mm).
The pieces should be a consistent length, with a maximum of 1” (25 mm) variation from
piece to piece.
3.2.4 Piece Size
Firewood dries more quickly when it is split. Large unsplit rounds can take years to dry
enough to burn. Even when dried, unsplit logs are difficult to ignite because they don’t
have the sharp edges where the flames first catch. Logs as small as 3” (75 mm) should be
split to encourage drying.
Wood should be split to a range of sizes, from about 3” to 6” (75 mm to 150 mm) in cross
section. Having a range of sizes makes starting and rekindling fires much easier. Often,
the firewood purchased from commercial suppliers is not split finely enough for convenient
stoking. It is sometimes advisable to resplit the wood before stacking to dry.
12
Page 13
Eldorado Installation and Operation Manual
3.2.5 How to Dry Firewood
Firewood that is not dry enough to burn is the cause of most complaints about wood
inserts. Continually burning green or unseasoned wood produces more creosote and
involves lack of heat and dirty glass door. See Section 5: Maintaining your wood heating system for concerns about creosote.
Here are some things to consider in estimating drying time:
•
firewood takes a long time to dry
•
firewood bought from a dealer is rarely dry enough to burn, so it is advisable to buy the
wood in spring and dry it yourself
•
drying happens faster in dry weather than in damp, maritime climates
•
drying happens faster in warm summer weather than in winter weather
•
small pieces dry more quickly than large pieces
•
split pieces dry more quickly than unsplit rounds
•
softwoods take less time to dry than hardwoods
•
softwoods like pine, spruce, and poplar/aspen can be dry enough to burn after being
stacked in the open for only the summer months
•
hardwoods like oak, maple and ash can take one, or even two years to dry fully,
especially if the pieces are big
•
firewood dries more quickly when stacked in the open where it is exposed to sun and
wind; it takes much longer to dry when stacked in a wood shed
•
firewood that is ready to burn has a moisture content between15 and 20% by weight
and will allow your stove to produce its highest possible efficiency
13
Page 14
Eldorado Installation and Operation Manual
Judging Firewood MoistureContent
You can find out if some firewoodis
cracks form at the ends of logsastheydry
as it dries in the sun, the woodturnsfromwhiteorcreamcolouredtogreyoryellow,
bang two pieces of wood together;seasonedwoodsoundshollowandwetwood
dry wood is much lighter in weight
split a piece, and if the freshfacefeelswarmanddryitisdryenoughtoburn;ifitfeels
burn a piece; wet wood hissesandsizzlesinthefireanddrywooddoesnot.
Do not burn manufactured logsmadeofwaximpregnatedsawdustorlogswithany
chemical additives. Manufacturedlogsmadeof100%compressedsawdustcanbe
tion in thenumberoftheselogsburnedatonetime.Startwithone
manufactured log and see howthestovereacts.Youcanincreasethenumberoflogs
making surethetemperatureneverriseshigherthan475°F(246°C)
a probe thermometer for installationondoublewallstovepipe
(457 mm)
dry enough to burn by using these guidelines:
You could buy a wood moisture metertotestyour
The thermometer
can
3.2.6
•
•
•
sounds dull,
•
•
damp, it is too wet,
•
than wet wood,
firewood.
3.3 Manufactured Logs
burned, but use cau
burned at a time to
on a magnetic the
be placed about 18”
and damage your stove.
.
above the stove. Higher temperatures
should
lead to overheat
14
Page 15
Eldorado Installation and Operation Manual
4 Operating Your Stove
4.1 The use of a fire screen.
This stove has been tested for use with an open door in conjunction with a fire screen
(AC01342, sold separately). Make sure the fire screen is properly secured on the stove to
avoid any risk of fire. When the fire screen is used, it is important not to leave the stove
unattended to respond promptly in the event of smoke spillage into the room. Potential
causes of smoke spillage are described in section height of this manual. See Appendix 2
for installation instructions.
OPERATING WITH THE FIRE SCREEN INCREASES POSSIBILITIES OF
GENERATING CARBON MONOXIDE. CARBON MONOXIDE IS AN ODOURLESS GAS
THAT IS HIGHLY TOXIC AND WHICH CAN CAUSE DEATH AT HIGH
CONCENTRATION IN AIR.
4.2 Your First Fires
Two things will happen as you burn your first few fires; the paint cures and the internal
components of the stove are conditioned.
As the paint cures, some of the chemicals vaporize. The vapors are not poisonous, but
they do smell bad. Fresh paint fumes can also cause false alarms in smoke detectors. So,
when you first light your stove, be prepared by opening doors and/or windows to ventilate
the house. As you burn hotter and hotter fires, more of the painted surfaces reach the
curing temperature of the paint. The smell of curing paint does not disappear until you
have burned one or two very hot fires.
Burn one or two small fires to begin the curing and conditioning process. Then build bigger
and hotter fires until there is no longer any paint smell from the stove. Once the paint smell
disappears, your stove is ready for serious heating.
4.3 Lighting Fires
Each person who heats with wood develops their own favorite way to light fires. Whatever
method you choose, your goal should be to get a hot fire burning quickly. A fire that starts
fast produces less smoke and deposits less creosote in the chimney. Here are three
popular and effective ways to start wood fires.
15
Page 16
Eldorado Installation and Operation Manual
4.3.1 Conventional Fire Starting
The conventional way to build a wood
fire is to bunch up 5 to 10 sheets of
plain newspaper and place them in the
firebox. Next, place 10 or so pieces of
fine kindling on the newspaper. This
kindling should be very thin; less than
1” (25 mm). Next, place some larger
kindling pieces on the fine kindling.
Open the air control fully and light the
newspaper. If you have a tall, straight
venting system you should be able to
close the door immediately and the fire
will ignite. If your venting system has
elbows or an outside chimney, you may
need to leave the door closed but
unlatched for a few minutes as the
newspaper ignites and heat in the
chimney produces some draft. Once
the fire has ignited, close the door and
leave the air control fully open.
A conventional kindling fire with paper
under finely split wood.
DO NOT LEAVE THE STOVE UNATTENDED WHEN THE DOOR IS SLIGHTLY
OPENED DURING IGNITION. ALWAYS CLOSE THE DOOR AFTER IGNITION.
After the kindling fire has mostly burned, you can add standard firewood pieces until you
have a fire of the right size for the conditions.
4.3.2 The Top Down Fire
The top down fire starting method solves two problems with the conventional method: first,
it does not collapse and smother itself as it burns; and second, it is not necessary to build
up the fire gradually because the firebox is loaded before the fire is lit. A top down fire can
provide up to two hours of heating or more. The top down method only works properly if
the wood is well-seasoned.
Start by placing three or four full-sized split pieces of dry firewood in the firebox. Next,
place 4 or 5 more finely split pieces of firewood (2” to 3” [50 mm to 75 mm] in dia.) on the
base logs at right angles (log cabin style). Now place about 10 pieces of finely split kindling
on the second layer at right angles.
The fire is topped with about 5 sheets of newspaper. You can just bunch them up and stuff
them in between the kindling and the underside of the baffle. Or you can make newspaper
knots by rolling up single sheets corner to corner and tying a knot in them. The advantage
of knots is that they don’t roll off the fire as they burn. Light the newspaper and watch as
the fire burns from top to bottom.
16
Page 17
Eldorado Installation and Operation Manual
4.3.3 Two Parallel Logs
Place two spit logs in the firebox. Place a few sheets of twisted newspaper between the
logs. Now place some fine kindling across the two logs and some larger kindling across
those, log cabin style. Light the newspaper.
4.3.4 Using Fire Starters
Many people like to use commercial fire starters instead of newspaper. Some of these
starters are made of sawdust and wax and others are specialized flammable solid
chemicals. Follow the package directions for use.
Gel starter may be used but only if there are no hot embers present. Use only in a cold
firebox to start a fire.
DO NOT USE FLAMMABLE LIQUIDS SUCH AS GASOLINE, NAPHTHA, FUEL OIL,
MOTOR OIL, OR AEROSOLS TO START OR REKINDLE THE FIRE.
4.4 Maintaining Wood Fires
4.4.1 General Advice
Wood heating with a space heater is very different than other forms of heating. There will
be variations in the temperature in different parts of the house and there will be variations
in temperature throughout the day and night. This is normal, and for experienced wood
burners these are advantages of zone heating with wood.
Do not expect steady heat output from your stove. It is normal for its surface temperature
to rise after a new load of wood is ignited and for its temperature to gradually decline as
the fire progresses. This rising and falling of temperature can be matched to your
household routines. For example, the area temperature can be cooler when you are active,
such as when doing housework or cooking, and it can be warmer when you are inactive,
such as when reading or watching television.
Wood burns best in cycles. A cycle starts when a new load of wood is ignited by hot coals
and ends when that load has been consumed down to a bed of charcoal about the same
size as it was when the wood was loaded. Do not attempt to produce a steady heat output
by placing a single log on the fire at regular intervals. Always place at least three, and
preferably more, pieces on the fire at a time so that the heat radiated from one piece helps
to ignite the pieces next to it. Each load of wood should provide several hours of heating.
The size of each load can be matched to the amount of heat needed.
When you burn in cycles, you rarely need to open the stove’s loading door while the wood
is flaming. This is an advantage because there is more chance that smoke will leak from
the stove when the door is opened as a full fire is burning. This is especially true if the
chimney connector has 90° elbows and if the chimney runs up the outside wall of the
house.
IF YOU MUST OPEN THE DOOR WHILE THE FUEL IS FLAMING, OPEN THE AIR
CONTROL FULLY FOR A FEW MINUTES, THEN UNLATCH AND OPEN THE DOOR
SLOWLY.
17
Page 18
Eldorado Installation and Operation Manual
4.4.2 Ash Removal
Ash should be removed from the firebox every two or three days of full time heating. Do
not let the ash build up in the firebox because it will interfere with proper fire management.
The best time to remove ash is after an overnight fire when the stove is relatively cool, but
there is still some chimney draft to draw the ash dust into the stove and prevent it from
coming into the room.
After ashes have been removed from the stove and placed in a tightly covered metal
container, they should be taken outside immediately. The closed container of ashes should
be placed on a non-combustible floor or on the ground well away from all combustible
materials pending final disposal. Ashes normally contain some live charcoal that can stay
hot for several days. If the ashes are disposed of by burial in soil or otherwise locally
dispersed, they should be retained in the closed container until all cinders have thoroughly
cooled. Other waste shall not be placed in this container.
NEVER STORE ASHES INDOORS OR IN A NON-METALIC CONTAINER OR ON A
WOODEN DECK.
4.4.3 Raking Charcoal
Rekindle the fire when you notice that the room temperature has fallen. You will find most
of the remaining charcoal at the back of the firebox, furthest from the door. Rake these
coals towards the door before loading. There are two reasons for this raking of the coals.
First, it concentrates them near where most of the combustion air enters the firebox and
where they can ignite the new load quickly, and second, the charcoal will not be smothered
by the new load of wood. If you were to simply spread the charcoal out, the new load will
smoulder for a long time before igniting.
Remove ash first, and then rake charcoal towards the front of the firebox before loading so
that it will ignite the new load.
4.4.4 Firing Each New Load Hot
Place the new load of wood on and behind the charcoal, and not too close to the glass.
Close the door and open the air control fully. Leave the air control fully open until the
firebox is full of flames, the wood has charred to black and its edges are glowing red. Firing
each load of wood hot accomplishes a few things:
•
drives the surface moisture from the wood,
•
creates a layer of char on the wood, which slows down its release of smoke,
•
heats the firebox components so they reflect heat back to the fire and
•
heats the chimney so it can produce strong, steady draft for the rest of the cycle.
18
Page 19
Eldorado Installation and Operation Manual
Although it is important to fire each new load hot to prepare for a clean burn, do not allow
the fire to burn at full intensity for more than a few minutes.
DO NOT LEAVE THE STOVE UNATTENDED WHILE A NEW LOAD IS BEING FIRED
HOT.
DO NOT OVERFIRE.
When you burn a new load of wood hot to heat up the wood, the stove and the chimney,
the result will be a surge of heat from the stove. This heat surge is welcome when the
room temperature is a little lower than desirable, but not welcome if the space is already
warm. Therefore, allow each load of wood to burn down so that the space begins to cool
off a little before loading. Letting the space cool before loading is one of the secrets to
clean burning and effective zone heating.
4.4.5 Turning Down the Air Supply
Once the firewood, firebox and chimney are hot, you can begin to reduce the air supply for
a steady burn.
As you reduce the air supply to the fire, two important things happen. First, the firing rate
slows down to spread the heat energy in the fuel over a longer period of time. Second, the
flow rate of exhaust through the stove and flue pipe slows down, which gives more time for
the transfer of heat from the exhaust. You will notice that as you reduce the air setting, the
flames slow down. This is your indication that the stove is burning at its peak efficiency.
If the flames get small and almost disappear when you turn down the air, you have turned
down the air too early, or your firewood is wetter than it should be. With good fuel and
correct air control use, the flames should slow down, but should stay large and steady,
even as the air supply is reduced.
4.4.6 Building Different Fires for Different Needs
Using the air control is not the only way to match the stove’s heat output to the heat
demand. Your house will need far less heat in October than in January to be kept at a
comfortable temperature. If you fill the firebox full in fall weather, you will either overheat
the space or turn the stove down so much that the fire will be smoky and inefficient. Here
are some suggestions for building fires to match different heat demand.
19
Page 20
Eldorado Installation and Operation Manual
4.4.6.1 Small Fires to Take the Chill Off the House
To build a small fire that will produce a low heat output, use small pieces of firewood and
load them crisscross in the firebox. The pieces should be only 3” to 4” in diameter. After
raking the coals, you can lay two pieces parallel to each other corner to corner in the
firebox and lay two more across them in the other direction. Open the air control fully and
only reduce the air after the wood is fully flaming. This kind of fire is good for mild weather
when you are around to tend the stove and should provide enough heat for four hours or
more. Small fires like this are a good time to use softer wood species so there will be less
chance of overheating the house.
4.4.6.2 Long Lasting Low Output Fires
Sometimes you will want to build a fire to last up to eight hours, but don’t need intense
heat. In this case use soft wood species and place the logs compactly in the firebox so the
pieces are packed tightly together. You will need to fire the load hot for long enough to fully
char the log surfaces before you can turn the air down. Make sure the fire is flaming
brightly before leaving the fire to burn.
4.4.6.3 High Output Fires for Cold Weather
When the heat demand is high during cold weather, you’ll need a fire that burns steadily
and brightly. This is the time to use your biggest pieces of hardwood fuel if you have it. Put
the biggest pieces at the back of the firebox and place the rest of the pieces compactly. A
densely built fire like this will produce the longest burn your stove is capable of.
You will need to be cautious when building fires like this because if the air is turned down
too much, the fire could smoulder. Make sure the wood is flaming brightly before leaving
the fire to burn.
4.4.6.4 Maximum Burn Cycle Times
The burn cycle time is the period between loading wood on a coal bed and the
consumption of that wood back to a coal bed of the same size. The flaming phase of the
fire lasts for roughly the first half of the burn cycle and the second half is the coal bed
phase during which there is little or no flame. The length of burn you can expect from your
stove, including both the flaming and coal bed phases, will be affected by a number of
things, such as:
•
firebox size,
•
the amount of wood loaded,
•
the species of wood you burn,
•
the wood moisture content,
•
the size of the space to be heated,
•
the climate zone you live in, and
•
the time of year.
20
Page 21
Eldorado Installation and Operation Manual
MAXIMUM
BURN TIME
The table below provides a very general indication of the maximum burn cycle times you
are likely to experience, based on firebox volume.
FIREBOX VOLUME
<1.5 cubic feet 3 to 5 hours
1.5 c.f. to 2.0 c.f 5 to 6 hours
2.0 c.f. to 2.5 c.f. 6 to 8 hours
2.5 c.f. to 3.0 c.f. 8 to 9 hours
>3.0 c.f. 9 to 10 hours
Long burn times are not necessarily an indication of efficient stove operation. When you
are home during the day and able to tend the fire, it is preferable to build a smaller fire that
might provide three or four hours of heating than to fully load the firebox for a much longer
burn. Shorter burn cycles make it easier to match the heat output of the stove to the heat
demand of the space.
4.4.6.5 North-South Fires Versus East-West Fires
In fireboxes that are roughly square, wood can be loaded so that looking through the glass
door you see the ends of the logs (north-south) or the sides of the logs (east-west).
East-west loads that are built compactly break down slowly when heated, but the amount
of wood you can load is limited because if you put in too many pieces, one may fall against
the glass. East-west loads are excellent for long, low output fires for relatively mild
weather.
North-south loads break down more quickly, but much more wood can be loaded at a time.
This makes north-south loading good for high output, long lasting fires for cold weather.
21
Page 22
Eldorado Installation and Operation Manual
5 Maintaining Your Wood Heating System
5.1 Stove Maintenance
Your new stove will give many years of reliable service if you use and maintain it correctly.
Some of the internal components of the firebox, such as firebricks, baffles and air tubes,
will wear over time under intense heat. You should always replace defective parts with
original parts (see Appendix 5: Exploded Diagram and Parts List). For firing each load
hot to begin a cycle as described above will not cause premature deterioration of the
stove. However, letting the stove run with the air control fully open for entire cycles can
cause damage over time. The hotter you run the stove throughout burn cycles, the more
quickly its components will deteriorate. For that reason, never leave the stove
unattended while a new load is being fired hot.
5.1.1 Cleaning Door Glass
Under normal conditions, your door glass should stay relatively clear. If your firewood is
dry enough and you follow the operating instructions in this manual, a whitish, dusty
deposit will form on the inside of the glass after a week or so of use. This is normal and
can be easily removed when the stove is cool by wiping with a damp cloth or paper towel
and then drying. Never try to clean the glass when the stove is hot.
In spring and fall when the stove is run at lower temperatures, you may see some light
brown stains forming, especially at the lower corners of the glass. This indicates that the
fire has been smoky and some of the smoke has condensed on the glass. When the
weather is mild, you may find that letting the fire go out is better than trying to maintain a
continuous fire. Use the technique described above for building a fire to take the chill off
the house.
If you do get brown stains on the glass you can remove them with special cleaners for
wood stove glass doors. Do not use abrasives to clean your stove’s door glass.
The deposits that form on the glass are the best indication of the quality of your fuel and
how well you are doing in operating the stove. Your goal should be clear glass with no
brown stains. If you continue to see brown stains on the glass, something about your fuel
and operating procedure needs to be changed. Stains on the glass indicate incomplete
combustion of the wood, which also means more smoke emissions and faster formation of
creosote in the chimney.
If you see brown streaks coming from the edge of the glass, it is time to replace the gasket
around the glass. Visit your stove retailer to get the self-adhesive glass gasket and follow
the instructions below for installation.
22
Page 23
Eldorado Installation and Operation Manual
5.1.2 Door adjustment
In order for your stove to burn at its best efficiency, the door must provide a perfect seal
with the firebox. Therefore, the gasket should be inspected periodically making sure to
obtain an air tight fit. Airtightness can be improved with a simple latch mechanism
adjustment. To adjust:
1. Remove the lock pin (spring pin) by pulling and turning it using pliers ("wise grip").
2. Turn the handle counter clock wise one turn to increase pressure.
3. Re-install the lock pin (spring pin) with a small hammer.
23
Page 24
Eldorado Installation and Operation Manual
5.1.3 Replacing the Door Gasket
It is important to maintain the gasket in good condition. After a year or more of use, the
door gasket will compress and become hard, which may allow air to leak past it. You can
test the condition of the door gasket by closing and latching the door on a strip of paper.
Test all around the door. If the paper slips out easily anywhere, it is time to replace the
gasket.
Use the correct replacement gasket that you can purchase from your retailer. The diameter
and density of the gasket is important to getting a good seal.
Place the door face-down on something soft like a cushion of rags or piece of carpet.
Remove the old gasket from the door by pulling and prying it out with an old screw driver.
Then use the screwdriver to scrape the old gasket adhesive from the door. Now run a 1/4”
(6 mm) bead of high temperature silicone in the door gasket groove. Starting from the
middle of the hinge side, press the gasket into the groove. Do not stretch the gasket as
you place it. Leave the gasket about 1/2” long when you cut it and press the end into the
groove. Tuck any loose fibres under the gasket and into the silicone. Close the door and
do not use the stove for 24 hours.
5.1.4 Replacing the Glass Gasket and/or the Glass
It is a good idea to replace the glass gasket when the door gasket is replaced. The gasket
is flat, adhesive-backed, woven fibreglass. Remove the glass retaining screws (A) and
both metal frames (B) that holds the glass (C) to the door frame (D). Lift out the glass (C)
and pull off the old gasket. This is a good time to clean the glass thoroughly.
The gasket must be centred on the edge of the glass. To do this easily, peel back a
section of the paper covering the adhesive and place the gasket on a table with the
adhesive side up. Stick the end of the gasket to the middle of one edge, then press the
edge of the glass down onto the gasket, taking care that it is perfectly centred on the
gasket. Peel off more of the backing and rotate the glass and press the next section onto
the gasket. Do not stretch the gasket as you place it. Continue until you get to the start and
trim the gasket to length. Now pinch the gasket to the glass in a U shape, all around the
glass. Reinstall the glass, being careful to centre the glass carefully in the door. Do not
over-tighten the screws. Note that the two main causes of broken door glass are uneven
placement in the door and over-tightening of retaining screws.
24
Page 25
Eldorado Installation and Operation Manual
Do not abuse the glass door by striking or slamming shut. Do not use the stove if the glass
is broken. To change the glass, perform the same operation described above.
5.1.5 Cleaning and Painting the Stove
Do not attempt to clean or paint the stove when the unit is hot. Painted surfaces can
be wiped down with a damp cloth. Plated surfaces may be scratched by abrasive cleaners.
To maintain the finish at its original brilliance, use only a damp soft cloth to clean plated
surfaces.
If the paint becomes scratched or damaged, you can give your wood stove a brand new
look by repainting it with heat-resistant paint. Before painting, roughen the surface with fine
sand paper, wipe it down to remove dust, and apply two thin coats of paint. For best
results, use the same paint that was originally used on the stove, which is available in
spray cans. See your dealer for details.
5.2 Chimney and Chimney Connector Maintenance
5.2.1 Why Chimney Cleaning is Necessary
Wood smoke can condense inside the chimney connector and chimney, forming a
combustible deposit called creosote. If creosote is allowed to build up in the venting
system it can ignite when a hot fire is burned in the stove and a very hot fire can progress
to the top of the chimney. Severe chimney fires can damage even the best chimneys.
Smouldering, smoky fires can quickly cause a thick layer of creosote to form. When you
avoid smouldering so the exhaust from the chimney is mostly clear, creosote builds up
more slowly. Your new stove has the right characteristics to help you to burn clean fires
with little or no smoke, resulting in less creosote in the chimney.
5.2.2 How Often Should You Clean the Chimney?
It is not possible to predict how much or how quickly creosote will form in your chimney. It
is important, therefore, to check the build-up in your chimney monthly when getting used to
the new stove until you determine the rate of creosote formation. Even if creosote forms
slowly in your system, the chimney should be cleaned and inspected at least once each
year.
25
Page 26
Eldorado Installation and Operation Manual
It is recommended to clean thoroughly the chimney system at the end of every heating
season. During summer, the air is damper and with minimal air circulation within the stove
or furnace, it can mix with creosote and/or sooth deposits in the chimney system to form
an acid that could accelerate the corrosion process and induce premature decay of the
steel. Corrosion damages are not covered under warranty. Have your chimney system
cleaned by a professional chimney sweep. Use a plastic or steel brush.
Contact your local municipal or provincial fire authority for information on how to handle a
chimney fire. Have a clearly understood plan to handle a chimney fire.
5.2.3 Cleaning the Chimney
Chimney cleaning can be a difficult and
dangerous job. If you don’t have
experience cleaning chimneys, you
might want to hire a professional
chimney sweep to clean and inspect
the system for the first time. After
having seen the cleaning process, you
can decide if it is a job you would like to
take on.
The most common equipment used are
fibreglass rods with threaded fittings
and stiff plastic brushes. The brush is
forced up and down inside the chimney
flue to scrub off the creosote.
The chimney connector assembly
should always be cleaned at the same
time the chimney is cleaned.
CAUTION: Operation of your stove without the baffle may cause unsafe and hazardous
temperature conditions and will void the warranty. NOTE: Before installing the firebrick,
check to ensure that none are broken or damaged in any way. If so, have the damaged
ones replaced. Check the firebrick for damage at least annually and replace any broken or
damaged ones with new ones. Inspection and cleaning of the chimney is facilitated by the
removable baffle.
26
Page 27
Eldorado Installation and Operation Manual
PART B - INSTALLATION
6 Safety Information
6.1 Summary of Installation Cautions and Warnings
•THE INFORMATION GIVEN ON THE CERTIFICATION LABEL AFFIXED TO THE
APPLIANCE ALWAYS OVERRIDES THE INFORMATION PUBLISHED, IN ANY OTHER
MEDIA (OWNER’S MANUAL, CATALOGUES, FLYERS, MAGAZINES AND/OR WEB
SITES).
•MIXING OF APPLIANCE COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING
COMPONENTS MAY RESULT IN HAZARDOUS CONDTIONS. WHERE ANY SUCH
CHANGES ARE PLANNED, STOVE BUILDER INTERNATIONAL INC. SHOULD BE
CONTACTED IN ADVANCE.
•ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN
WRITING BY THE TESTING AUTHORITY VIOLATES CSA B365 (CANADA), AND ANSI
NFPA 211 (USA).
•CONNECT THIS STOVE ONLY TO A LISTED FACTORY-BUILT CHIMNEY FOR USE WITH
SOLID FUEL OR TO A LINED MASONRY CHIMNEY CONFORMING TO NATIONAL AND
LOCAL BUILDING CODES.
•IF REQUIRED, A SUPPLY OF COMBUSTION AIR SHALL BE PROVIDED TO THE ROOM
OR SPACE.
•DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DISTRIBUTION
DUCTWORK UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATION.
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
• MAY BE INSTALLED IN A MOBILE HOME
• THIS MOBILE HOME APPROVED STOVE REQUIRES INSTALLATION OF A FRESH AIR
INTAKE KIT, SOLD SEPARATELY.
WARNING: DO NOT INSTALL IN SLEEPING ROOM.
WARNING: THE STOVE MUST BE ATTACHED TO THE STRUCTURE OF THE MOBILE HOME.
CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL, AND
CEILING/ROOF MUST BE MAINTAINED.
6.2 Regulations Covering Stove Installation
When installed and operated as described in these instructions, the Eldorado wood stove
is suitable for use as a freestanding heater in residential installations. The Eldorado wood
stove is not intended for installation in a sleeping room of a mobile home.
In Canada, the CSA B365 Installation Code for Solid Fuel Burning Appliances and
Equipment and the CSA C22.1 Canadian National Electrical Code are to be followed in the
absence of local code requirements. In the USA, the ANSI NFPA 211 Standard for
Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances and the ANSI NFPA 70
National Electrical Code are to be followed in the absence of local code requirements.
This stove must be connected to a chimney complying with the requirements for Type HT
chimneys in the Standard for Factory-Built Chimneys for Residential Type and Building
Heating Appliances, UL 103 HT and ULC S629 or to a code-approved masonry chimney
with a flue liner.
27
Page 28
Eldorado Installation and Operation Manual
7 Clearances to Combustible Material
The clearances shown in this section have been determined by test according to
procedures set out in safety standards ULC S627 (Canada), UL1482 (U.S.A.) and UL737
(U.S.A.). When the stove is installed so that its surfaces are at or beyond the minimum
clearances specified, combustible surfaces will not overheat under normal and even
abnormal operating conditions.
No part of the stove or flue pipe may be located closer to combustibles than the
minimum clearance figures given.
7.1 Location of the certification label
Since the information given on the certification label affixed to the appliance always
overrides the information published, in any other media (owner’s manual, catalogues,
flyers, magazines and/or web sites) it is important to refer to it in order to have a safe and
compliant installation. In addition, you will find information about your stove (model, serial
number, etc.). You can find the certification label on the back of the stove.
7.2 Clearances to Walls and Ceiling
The clearances to combustible walls may be slightly different in Canada and the U.S.A.
and may also differ depending on whether you use single or double wall flue pipe. Please
be sure to choose the correct clearance for your location and type of flue pipe. See figure
Clearances to combustible materials and floor protection to match each letter to a
clearance.
CANADA USA
A 19" (483 mm) 19" (483 mm)
B 21" (533 mm) 21" (533 mm)
C 16" (406 mm) 16" (406 mm)
D 24½" (622 mm) 24½" (622 mm)
E 29½" (749 mm) 29½" (749 mm)
F 25¼" (641 mm) 25¼" (641 mm)
K 48" (1219 mm) 48" (1219 mm)
L 72" (183 cm) 72" (183 cm)
Note: Clearances for single wall are also valid for an alcove installation.
CLEARANCES
(SINGLE WALL PIPE)
CANADA USA
A 12" (305 mm) 12" (305 mm)
B 21" (533 mm) 21" (533 mm)
C 12" (305 mm) 12" (305 mm)
D 17½" (445 mm) 17½" (445 mm)
E 29½" (749 mm) 29½" (749 mm)
F 21¼" (540 mm) 21¼" (540 mm)
K 48" (1219 mm) 48" (1219 mm)
L 72" (183 cm) 72" (183 cm)
CLEARANCES
(DOUBLE WALL PIPE)
28
Page 29
Eldorado Installation and Operation Manual
Clearances for mobile homes
MOBILE HOME CLEARANCES (DOUBLE WALL
CANADA USA
A 13" (330 mm) 13" (330 mm)
B 21" (533 mm) 21" (533 mm)
C 12" (305 mm) 12" (305 mm)
D 18½" (470 mm) 18½" (470 mm)
E 29½" (749 mm) 29½" (749 mm)
F 21¼" (540 mm) 21¼" (540 mm)
K 48" (1219 mm) 48" (1219 mm)
L 84" (213 cm) 84" (213 cm)
PIPE)
29
Page 30
Eldorado Installation and Operation Manual
G
H
I
J
M
N
Clearances to combustible materials and floor protection
7.3 Floor protector
If the stove is to be installed on top of a combustible floor, it must be guarded by a non
combustible material as shown on figure 1.3 (see the dotted line area).
CANADA USA
8’’ (203 mm) – Note 1 N/A (Canada only)
8’’ (203 mm) N/A (Canada only)
18’’ (457 mm)
From door opening
N/A (USA only) 8’’ (203 mm)
8’’ (203 mm) N/A (Canada only)
N/A (USA only) Note 2
*Steel with a minimum thickness of 0.015’’ (0.38 mm) or ceramic tiles sealed together
with grout. No protection is required if the unit is installed on a non-combustible floor
(ex: concrete).
FLOOR PROTECTOR*
16’’ (406 mm)
From door opening
Note 1: The floor protection at the back of the stove is limited to the stove’s required
clearance if such clearance is smaller than 8 inches (203 mm).
Note 2: Only required under the horizontal section of the connector. Must exceed each
side of the connector by at least 2 inches (51 mm).
30
Page 31
Eldorado Installation and Operation Manual
-
-
-
A
B
C
D
E
F
G
H
7.4 Reducing Wall and Ceiling Clearances Safely
It is often desirable to reduce
the minimum installation
clearances by placing the stove
closer to walls so the installation
takes up less floor space. You
can safely reduce the minimum
clearances by permanently
installing a shield between the
stove and combustible material.
The rules for safe shields can
be complicated, so read them
carefully and follow them
exactly. Note that there may be
minor regional differences in
clearance reduction rules so be
sure to check with your building
or fire inspector before
proceeding.
7.4.1 Shield Construction Rules
See figure Clearances for shield construction to match each letter to a clearance.
Adhesives used in shield construction must not ignite or lose adhesive qualities at
temperatures likely to be encountered.
Mounting hardware which extends from the shield surface into combustibles may be
used only at the edges of the shield.
Mounting hardware must allow full vertical ventilation.
Minimum clearance between the appliance top and an unshielded combustible ceiling:
1137 mm (44¾ in.).
Shield extension above appliance: 500 mm (20 in.).
Minimum space behind shield: 25 mm (1 in.). In Canada 21 mm (7/8 in).
Clearance along the bottom of shield: minimum: 25 mm (1 in.) and maximum: 75 mm (3
in.).
Minimum clearance along the top of shield at ceiling: 75 mm (3 in.).
Mounting hardware must not be located closer than 200 mm (8 in.) from the vertical
centre line of the appliance.
Edge clearance for ceiling shields to side and back walls: 75 mm (3 in.).
Shield extension beyond each side of appliance: 450 mm (18 in.).
31
Page 32
Eldorado Installation and Operation Manual
Clearances for
shield construction
32
Page 33
Eldorado Installation and Operation Manual
Clearances may be reduced by these
Sides
Top %
Can/US
USA
Can/US
USA
minimum of 24 gauge (0.61 mm)
7.4.2 Table of Clearance Reduction Percentages
percentages
Type of shield
and rear %
(ceiling)
Sheet metal, a minimum of 24
gauge (0.61 mm) in thickness ,
spaced out at least 25 mm (1 in)*
by non-combustible spacers
Ceramic tiles, or equivalent noncombustible material, on noncombustible board spaced out at
least 25 mm (1 in)* by noncombustible spacers
Ceramic tiles, or equivalent noncombustible material, on noncombustible board, with a
sheet metal backing spaced out at
least 25 mm (1 in)* by noncombustible spacers
A
(%)
min.
A
(%)
min.
67 12 in 50 18 in
50 18 in 33 24 in
67 12 in 50 24 in
Brick, spaced out at least 25 mm
(1 in)* by non-combustible spacers
Brick, with a minimum of 24 gauge
(0.61 mm) sheet metal backing,
spaced out at least 25 mm (1 in)*
by non-combustible spacers
* In Canada this space can be 21 mm (7/8 in)
50 18 in N/A N/A
67 12 in N/A N/A
33
Page 34
Eldorado Installation and Operation Manual
Venting System
The venting system, made up ofthechimneyandtheconnectingpipebetweenthestove
acts as the engine
stove will not function safely andefficientlyasintended
The heat in the flue gases thatpassfromthestoveandchimneyconnectorintothe
chimney is not waste heat. Thisheatiswhatthechimneyusestomakethedraftthat
draws in combustion air, keepssmokeinsi
outside. You can think of heat inthefluegasasthefuelthechimneyusestomakedraft.
Your wood stove will provide optimumefficiencyandperformancewhenconnectedtoa6
least 5 inches (Canada only) ornomorethan7inchesispermitted,ifitallowstheproper
venting of combustion gases andthatsuchapplicationisverifiedandauthorizedbya
fied installer. Otherwise, thediameter
-
UL103HT
(U.S.A.) or ULC S629 (Canada).
built Metal Chimneys
These are sometimes referredtoas‘high
temp’ chimneys because theyhavethe
special characteristics to withstandthe
temperatures that can be createdbywood
built chimneysare
tested as a system with all thenecessary
for installation.The
instructions provided with the chimneyby
its manufacturer are the onlyreliable
source of installation guidelines.Tobe
safe and effective, the chimneymustbe
installed exactly in accordancewiththe
manufacturer’s instructions.
components intended for thebrandand
model of chimney you are using.Never
substitute parts from otherchimney
brands or fabricate yourown
The chimney mustbea
that drives your wood heating system.Eventhebest
if it is not connectedtoasuitable
de the stove and safely ventsexhaustto
8 The
8.1 General
and the chimney,
chimney.
8.2 Suitable Chimneys
inch diameter
quali
To be suitable, a factory
chimney must comply with
-
of the flue should be 6 inches.
built metal
8.2.1 Factory-
burning stoves. Factorycomponents
components.
type suitable for solid fuel.
Use only
34
Page 35
Eldorado Installation and Operation Manual
8.2.2 Factory-
built Metal Chimneysin
For use in a mobile home, this
in diameter
factory built chimney conformingto
S629, Standards for650°C
. The totallengthof
system should be at least
the top ofthestove.
To maintain an effective vapourbarrier
at thechimney
installamobile
home roof flashing and seal it withsilicone.
mobile homes
be connected to a 6”
wall
CAN/UCLFactory-built chimney
the flue
including elbows, from
insulation and waterproof
and outside flue pipe,
stove is to
double
12 feet
,
35
Page 36
Eldorado Installation and Operation Manual
8.2.3 Masonry Chimneys
connectedtoa
masonry chimney, providedthe
chimney complies with the construction
rules found in the buildingcode
enforced locally. The chimneymust
have either a clay liner or a suitably
listed stainless steel liner. Ifthe
masonry chimney has a square
rectangular liner that is larger incross
sectional area than a round 6”flue,it
should be relined with a suitablylisted
6” stainless steel liner. Donot
downsize the flue to less than 6”unless
the venting system is straightand
eight.
combustible wall,the
thimbleis
Minimum Chimney Height
The top of the chimney shouldbe
tall enough to be above the air
turbulence caused when wind
blows against the house andits
The chimney must extendat
least 1 m (3 ft.) above the highest
point of contact with the roof, and
at least 60 cm (2 ft.) higher than
any roof line or obstacle withina
horizontal distance of 3 m (10 ft.).
The stove may also be
or
exceeds 25 feet in h
passing through a
use of an insulated listed
required.
8.3
roof.
When
36
Page 37
Eldorado Installation and Operation Manual
The Relationship BetweentheChimneyandthe
Because the venting system istheenginethatdrivesthewoodheatingsystem,itmust
have the right characteristics. Thesignsofbadsystemdesignarecoldbackdraftingwhen
there is no fire in the stove, slowkindlingofnewfires,andsmokeroll
opened for loading. There aretwoguidelinestofollow.First,thechimneyshouldbe
installed up through the heatedspaceofthehouse,notoutandupanoutsidewall.
Second, the chimney should penetratethetopofthebuildingato
Why inside chimneys arepreferred
Venting systems that rise straightupfromthestovefluecollarprovidethebest
performance. Chimneys that riseinsidethewarmspaceofthehousetendtoprovidea
even whenthereisnofireburning.Thismeansthatwhenyoulighta
fire, the initial smoke goes up thechimneyandstrongdraftbuildsquicklyasthechimney
flue warms up. Although they arecommoninNorthAmerica,chimneysthatexitahouse
un up outside can causeproblems.
Good System Design
Inside chimneys are preferredbecauseeven
when no fire is burning, thereisnormally
upward flow in the system.
out whenthedooris
r near thehighestheated
Inferior System Design
Outside chimneys areaproblem
because when no fire burnstheywillgo
into cold backdraft if thestoveis
installed low in thehouse.
8.4
space.
8.4.1
small amount of draft
wall and r
House
-
37
Page 38
Eldorado Installation and Operation Manual
8.4.2 Why the chimney should penetrate the highest heated space
When it is cold outside, the warm air in the house is buoyant so it tends to rise. This
tendency of warm air to rise creates a slight pressure difference in the house. Called ‘stack
effect’, it produces a slightly negative pressure low in the house (relative to outside) and a
slightly positive pressure zone high in the house. If there is no fire burning in a heater
connected to a chimney that is shorter than the warm space inside the house, the slight
negative pressure low in the house will compete against the desired upward flow in the
chimney.
There are two reasons why the
chimney in the house at right will
cold backdraft when it is cold
outside and there is no fire
burning in the stove. First, the
chimney runs up the outside of
the house, so the air in it is colder
and denser than the warm air in
the house. And second, the
chimney is shorter than the
heated space of the house,
meaning the negative pressure
low in the house will pull outside
air down the chimney, through the
stove and into the room. Even the
finest stove will not work well
when connected to this chimney.
8.5 Supply of Combustion Air
In Canada, wood stoves are not required to have a supply of combustion air from outdoors
(except in mobile homes) because research has shown that these supplies do not give
protection against house depressurization and may fail to supply combustion air during
windy weather. However, to protect against the risk of smoke spillage due to house
depressurization, a carbon monoxide (CO) detector/alarm is required in the room in
which the stove is installed. The CO detector will provide warning if for any reason the
wood stove fails to function correctly.
38
Page 39
Eldorado Installation and Operation Manual
8.5.1 Combustion Air Supply in Mobile Homes
Only a wood stove certified and labelled as ‘mobile home approved’ may be
installed in a mobile home. This Eldorado stove is ‘mobile home approved’.Wood stoves
installed in mobile homes must have a ducted supply of combustion air from outdoors. This
air supply should be routed down through the house floor into the vented crawl space
under the mobile home. The air supply duct should be non-combustible aluminum flex duct
with a screened weatherhood on the outside end.
Note: Fabric duct may also be used, provided it is suitable for HVAC use and meets the
requirements of ULC-S110 or UL-181 Class 1 standards. It must have a non-combustible
insulation and be corrosion resistant.
Where a mobile home has been converted to a standard house by mounting it on a
permanent basement foundation, the supply of outdoor air is not required.
8.5.2 Air Supply in Conventional Houses
The safest and most reliable supply of combustion air for your wood stove is from the room
in which it is installed. Room air is already preheated so it will not chill the fire, and its
availability is not affected by wind pressures on the house. Contrary to commonly
expressed concerns, almost all tightly-sealed new houses have enough natural leakage to
provide the small amount of air needed by the stove. The only case in which the wood
stove may not have adequate access to combustion air is if the operation of a powerful
exhaust device (such as a kitchen range exhaust) causes the pressure in the house to
become negative relative to outdoors.
Some jurisdictions in the United States require that wood stoves have a supply of
combustion air from outdoors. If you do install an air supply through the wall of the house,
be aware that its pressure can be affected during windy weather. If you notice changes in
wood stove performance in windy weather, and in particular if smoke puffs from the stove,
you should disconnect the outdoor air duct from the stove and remove the duct. In some
windy conditions, negative pressure at the duct weatherhood outside the house wall may
draw hot exhaust gases from the stove backwards through the duct to outdoors. Check the
outdoor air duct for soot deposits when the full system is cleaned and inspected at least
once each year.
8.6 Installing the Chimney Connector
The chimney connector is the single or double wall pipe installed between the stove flue
collar and the chimney breech. Single wall pipe components are available from most
hardware and building supply stores. These components are not usually tested to a
particular standard and certified as compliant. Therefore, a list of rules found in solid fuel
installation codes apply to the installation of single wall pipe.
Double wall chimney connectors are tested and certified. The rules for double wall pipe are
found in the manufacturer’s installation instructions. These rules will be very different than
those for single wall.
39
Page 40
Eldorado Installation and Operation Manual
Installation of Single WallChimneyConnector
The chimney connector assemblyhasbeencalled‘theweaklink’inthesafetyofwood
stems because failuretoinstalltheconnectorproperly(whichhasbeencommon
in the past) can result in house fires.
The best flue pipe assembly isonethatrisesstraightupfromthestovetothebaseofthe
chimney with no elbows. Straightassemblies
out when the door is openedforloading.Theyarealsomorestableandeasierto
maintain than assemblies withelbows.Horizontalrunsoffluepipeshouldbeavoided
where possible because they reducechimn
s where possible,insteadof90°
are less likely to cause problemslikesmoke
8.6.1
heating sy
roll-
ey draft.
Use 45° elbow
elbows.
40
Page 41
Eldorado Installation and Operation Manual
The rules below are based on those found in the CSA B365 installation code. Please
carefully follow these installation instruction rules, or those enforced where you live.
•
Maximum overall length of straight pipe: 3 m (10 ft.) including elbows.
•
Minimum clearance from combustible material: 450 mm (18 in.). The minimum
clearance may be reduced by 50 percent to 225 mm (9 in.) if suitable shielding is
installed either on the pipe or on the combustible surface.
•
The assembly should be as short and direct as possible between the stove and
chimney. The use of two 45° elbows is often preferable to a single 90° elbow because
less turbulence is created in the exhaust flow and they result in less horizontal run.
•
Maximum number of 90° elbows: 2.
•
Maximum unsupported horizontal length: 1 m (3 feet).
•
Galvanized flue pipes must not be used because the coatings vaporize at high
temperatures and release dangerous gases. Use black painted flue pipes.
•
Flue pipes must be at least 24 gauge in thickness.
•
Flue pipe joints should overlap 30 mm (1 1/4 in.)
•
Each joint in the assembly must be fastened with at least three screws.
•
The assembly must have allowance for expansion: elbows in assemblies allow for
expansion; straight assemblies should include an inspection wrap with one end
unfastened, or a telescopic section.
•
Minimum upward slope towards the chimney: 20 mm/m (1/4 in/ft.).
•
One end of the assembly must be securely fastened to the flue collar with 3 sheet
metal screws and the other end securely fastened to the chimney.
•
There must be provision for cleaning of the pipes, either through a clean out or by
removal of the pipe assembly. Removal of the assembly should not require that the
stove be moved.
•
The male ends of the sections must be oriented towards the appliance so that falling
dust and condensation stay inside the pipe.
•
A flue pipe must never pass through a combustible floor or ceiling or through an attic,
roof space, closet or concealed space.
•
Where passage through a wall or partition of combustible construction is desired, the
installation shall conform to CAN/CSA-B365, Installation Code for Solid-Fuel-Burning
Appliances and Equipment.
The ideal flue pipe assembly is one that rises straight up from the appliance flue collar and
directly into the chimney with no elbows. A straight up connector assembly needs either a
telescopic length or an inspection wrap (pipe coupler) to allow it to be assembled and
disassembled without moving the stove.
A straight flue pipe assembly offers the least restriction to gas flow and results in stronger
draft. Straight assemblies also need less maintenance because there are no corners to
collect creosote.
The chimney connector must be in good condition.
41
Page 42
Eldorado Installation and Operation Manual
Appendix 1: Installing the Fresh Air Intake Kit
When installed with a fresh air intake kit, the stove must be anchored to the floor. Secure
each leg (A) with the proper anchoring system (B) (not provided) depending on your
installation, as shown bellow.
To be considered mobile home approved, this stove requires installation of a fresh air
intake kit (A) and an insulated fresh air intake pipe (B), sold separately.
Installation on the back:
42
Page 43
Eldorado Installation and Operation Manual
Appendix 2: Installing the Optional Fire Screen (AC01342)
Open the door.
Hold the fire screen by the two
handles and bring it close to the
door opening.
Lean the upper part of the fire
screen against the top door opening
making sure to insert the top fire
screen brackets behind the primary
air deflector as shown.
Lift the fire screen upwards and
push the bottom part towards the
stove then let the fire screen rest on
the bottom of the door opening.
Warning: Never leave the stove unattended while in use with the fire
screen.
43
Page 44
Eldorado Installation and Operation Manual
Appendix 3: Installation and Use of Blower and Optional
Thermodisc
A blower is installed on the back of the stove to increase the flow of air past heat exchange
surfaces and to help circulate warm air in the room. When used regularly, the blower can
provide a small increase in efficiency, up to 2 percent. However, the use of a blower
should not be used as a way to gain more output from a stove that is undersized for the
space it is intended to heat.
When using the blower, allow the stove to reach operating temperature (approximately one
hour), before turning it on. The increased airflow from the blower cools the firebox and
could affect the start-up combustion efficiency if the blower is turned on too early. You can
also install a thermodisc to enable the blower to start or stop automatically when the stove
is hot or too cold. The thermodisc part number is AC05530 for a basic model and
ACO2055 for a quick connect model. Installation instructions are supplied with the blower
and the thermodisc.
44
Page 45
Eldorado Installation and Operation Manual
CAUTION: ENSURE THAT THE BLOWER’S POWER CORD IS NOT IN CONTACT
WITH ANY SURFACE OF THE STOVE TO PREVENT ELECTRICAL SHOCK OR FIRE
DAMAGE. DO NOT RUN THE POWER CORD BENEATH THE STOVE.
45
Page 46
Eldorado Installation and Operation Manual
Appendix 4: Installation of Secondary Air Tubes and Baffle
1- Starting with the rear tube, lean and
insert the right end of the secondary
air tube into the rear right channel
hole. Then lift and insert the left end of
the tube into the rear left channel.
2- Align the notch in the left end of the
tube with the key of the left air channel
hole. Using a « Wise grip » hold the
tube and lock it in place by turning the
tube as shown. Make sure the notch
reaches the end of the key way.
3- Repeat step 1 and 2 for the other
secondary air tubes.
4- To remove the tubes use the above
steps in reverse order.
46
Page 47
Eldorado Installation and Operation Manual
Note that secondary air tubes (A) can be replaced without removing the baffle board (B).
Important Notes:
The air tubes are identified for placement as follows:
Model Type of tube
Eldorado
Middle front ► 30 holes of 0.136’’
Middle rear ► 20 holes of 0.147’’
Front ► 30 holes of 0.140"
Rear ► 15 holes of 0.128’’
47
Page 48
Eldorado Installation and Operation Manual
Appendix 5: Exploded Diagram and Parts List
48
Page 49
Eldorado Installation and Operation Manual
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement
parts for your stove, please provide the model number and the serial number. We reserve
the right to change parts due to technology upgrade or availability. Contact an authorized
dealer to obtain any of these parts. Never use substitute materials. Use of non-approved
parts can result in poor performance and safety hazards.
# ITEM DESCRIPTION QTY
1 AC01342 FIRE SCREEN 1
2 30569 ROUND WOODEN HANDLE BLACK 2
3 AC07868 1/2 " BLACK COIL HANDLE 1
4 SE24219-01 CAST IRON DOOR WITH GASKET, HANDLE AND LATCH 1
5 AC06000 SILICONE AND 1/2" x 8' BLACK GASKET REPLACEMENT KIT (DOOR) 1
6 AC09155 HANDLE AND LATCH KIT 1
7 AC09185 DOOR LATCH KIT 1
8 30101 SPRING TENSION PIN 5/32" DIA X 1 1/2" LONG 1
17 30187 ZINC WASHER ID 17/64" x OD 1/2" 1
18 30206 ZINC WASHER ID=5/16" x OD=3/4" 1
19 PL65572 AIR CONTROL ROD GUIDE 1
20 SE54634 AIR CONTROL ROD ASSEMBLY 1
21 30429 3/8'' CHROME COIL HANDLE 1
22 SE54674 ASH DRAWER ASSEMBLY 1
23 SE54707 OUTSIDE AIR INLET TAKE-OFF 1
24 99999 BUILD TO ORDER 1
25 SE45661 ELDORADO INSTRUCTION MANUAL KIT 1
26 AC02050 100 CFM BLOWER WITH VARIABLE SPEED CONTROL 1
27 60013 POWER CORD 96" X 18-3 type SVT 1
28 44080 RHEOSTAT WITH NUT 1
29 44087 RHEOSTAT NUT 1
30 44085 RHEOSTAT KNOB 1
31 44073 CROSSFLOW BLOWER 115V-60Hz-39W 100 CFM 1
32 AC02055 QUICK CONNECT THERMODISC 1
32 AC05530 THERMODISC KIT 1
33 44046 THERMODISC F110-20F 1
34 SE16059 ASH DUMP PLUG 1
THREAD-CUTTING SCREW 1/4-20 x 1/2" F HEX STEEL SLOT WASHER
C102 ZINC
6
49
Page 50
Eldorado Installation and Operation Manual
# ITEM DESCRIPTION QTY
35 PL36119 3 1/2" X 8" X 1 1/4" REFRACTORY BRICK 2
36 PL36084 4" X 4 1/2'' X 1 1/4'' REFRACTORY BRICK 1
37 29015 4'' x 9'' x 1.25'' REFRACTORY BRICK 12
38 PL36027 3" X 9" X 1 1/4'' REFRACTORY BRICK 2
39 PL54512 SECONDARY AIR TUBE 1
40 PL54513 SECONDARY AIR TUBE 1
41 PL54514 SECONDARY AIR TUBE 1
42 PL54515 SECONDARY AIR TUBE 1
43 21397 BAFFLE VERMICULITE BOARD (17-1/8'' X 9-3/4'' X 1-1/4'') 1
50
Page 51
Eldorado Installation and Operation Manual
DROLET LIMITED LIFETIME WARRANTY
The warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This warranty covers brand
new products only, which have not been altered, modified nor repaired since shipment from factory. Proof of purchase (dated bill of
sale), model name and serial number must be supplied when making any warranty claim to your DROLET dealer.
This warranty applies to normal residential use only. Damages caused by misuse, abuse, improper installation, lack of
maintenance, over firing, negligence or accident during transportation, power failures, downdrafts, venting problems or underestimated heating area are not covered by this warranty. The heated area indicated for a given appliance is defined by the
manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.
This warranty does not cover any scratch, corrosion, distortion, or discoloration. Any defect or damage caused by the use of
unauthorized parts or others than original parts void this warranty. An authorized qualified technician must perform the installation in
accordance with the instructions supplied with this product and all local and national building codes. Any service call related to an
improper installation is not covered by this warranty.
The manufacturer may require that defective products be returned or that digital pictures be provided to support the claim. Returned
products are to be shipped prepaid to the manufacturer for investigation. If a product is found to be defective, the manufacturer will
repair or replace such defect. Transportation fees to ship the product back to the purchaser will be paid by the manufacturer. Repair
work covered by the warranty, executed at the purchaser’s domicile by an authorized qualified technician requires the prior approval of
the manufacturer. All parts and labour costs covered by this warranty are limited according to the table below.
The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation of the defect. The
manufacturer may, at its discretion, fully discharge all obligations with respect to this warranty by refunding the wholesale price of any
warranted but defective parts. The manufacturer shall in no event be responsible for any special, indirect, consequential damages of any
nature, which are in excess of the original purchase price of the product. A one-time replacement limit applies to all parts benefiting
from a lifetime coverage. This warranty applies to products purchased after March 1st, 2015.
extrusions), plating* (defective manufacture), and convector air-mate.
Removable stainless steel components, secondary air tubes*, deflectors and
supports.
PARTS LABOUR
Lifetime
3 years
5 years 3 years
5 years n/a
Glass retainers, handle assembly and air control mechanism. 3 years 1 year
Carbon steel firebox components, glass retainers, C-Cast baffle* and
vermiculite baffle*.
2 years n/a
Standard blowers, heat sensors, switches, rheostat, wiring, and other controls. 1 year 1 year
Optional blowers, ceramic glass (thermal breakage only*), paint (peeling),
gaskets, insulation, and ceramic fibre blankets.
1 year
n/a
Firebrick n/a n/a
All parts replaced under the warranty.
*Pictures required.
Labour cost and repair work to the account of the manufacturer are based on predetermined rate schedule and must not exceed the
wholesale price of the replacement part.
Shall your unit or a components be defective, contact immediately your DROLET dealer. Prior to your call make sure you have the
following information necessary to your warranty claim treatment:
• Your name, address and telephone number;
• Bill of sale and dealer’s name;
• Serial number and model name as indicated on the
nameplate fixed to the back of your unit;
•Nature of the defect and any relevant information.
90 days
n/a
Before shipping your unit or defective component to our plant, you must obtain from your DROLET dealer an Authorization Number.
Any merchandise shipped to our plant without authorization will be refused automatically and returned to sender
.
51
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.