Drolet DG05437, DG05447 User Manual

ULTRA FLAME
DIRECT VENT "0" CLEARANCE GAS FIREPLACE
INSTALLATION AND OPERATING INSTRUCTIONS
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE
OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL INFORMATION, CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY, OR THE GAS SUPPLIER.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS AND
LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any electrical appliance
Do not touch any electrical switch
Do not use any phone in your building
Immediately call your gas supplier from a neighbour’s phone
Follow the gas supplier’s instruction
I f you cannot reach your gas supplier, call the fire department
Manufactured by : DROLET STOVES & FIREPLACES INC. 1700 Leon-Harmel
Quebec, QC G1N 4R9 Canada
Rev 07/98 45046A
Tested by : Intertek Testing Services
WARNOCK HERSEY
ULTRA FLAME DV “0” Clearance Fireplace
TABLE OF CONTENTS
GENERAL INFORMATION................................................................................................. 3
WARNING ............................................................................................................................... 4
SPECIFICATIONS..................................................................................................................5
OPERATION ........................................................................................................................... 6
BEFORE LIGHTING.................................................................................................. 6
LIGHTING PROCEDURE......................................................................................... 6
WALL THERMOSTAT.............................................................................................7
SHUTDOWN................................................................................................................ 7
BLOWER...................................................................................................................... 7
MAINTENANCE INSTRUCTIONS...................................................................................... 8
GLASS MAINTENANCE........................................................................................... 8
BURST DISC REPLACEMENT................................................................................9
TOP, FRONT AND SIDE VIEWS......................................................................................... 10
INSTALLATION..................................................................................................................... 11
POSITIONING THE FIREPLACE........................................................................... 11
VENT TERMINAL LOCATION............................................................................... 12
MINIMUM CLEARANCE TO COMBUSTIBLES ................................................. 13
INSTALLATION OF THE UNIT.............................................................................. 14
VENTING KITS .......................................................................................................... 16
1) STRAIGHT OUT INSTALLATION..................................................................... 17
2) CORNER INSTALLATION .................................................................................. 17
3) BASEMENT INSTALLATION ............................................................................. 18
VENTING SYSTEM.................................................................................................... 19
VENT TERMINAL, STRAIGHT OUT AND CORNER INSTALLATION ......... 20
VENT TERMINAL, BASEMENT INSTALLATION.............................................. 20
VENT TERMINAL, ROOF INSTALLATION ........................................................ 21
OPTIONAL BLOWER INSTALLATION................................................................ 21
GLASS FRONT REMOVAL, CLEANING AND INSTALLATION.................... 22
BURNER REMOVAL AND INSTALLATION........................................................ 22
EMBER KIT INSTALLATION................................................................................. 23
LOG INSTALLATION.............................................................................................. 24
LOUVRE INSTALLATION....................................................................................... 25
OPTIONAL REFRACTORY PANEL INSTALLATION....................................... 26
ADJUSTMENTS...................................................................................................................... 27
ADJUSTING THE GAS PRESSURE........................................................................ 28
ADJUSTING AIR SHUTTER.................................................................................... 29
WALL THERMOSTAT.............................................................................................. 29
OPTIONAL PARTS................................................................................................................ 30
REPLACEMENT PARTS ...................................................................................................... 30
LIMITED 5 YEAR WARRANTY.......................................................................................... 31
2
ULTRA FLAME DV “0” Clearance Fireplace
GENERAL INFORMATION
The ULTRA FLAME DIRECT VENT GAS FIREPLACE is a high-efficiency free-standing gas appliance with a maximum input rating of 30 000 Btu/h with natural gas or 26,000 Btu/h with propane. It features a thermostatic modulating valve and a constant pilot. This means that you can set the height of the flame to your liking by turning the adjusting knob. An optional thermostat is also available for automatic room temperature control. The valve is also independent of any exterior electrical supply. Your appliance will therefore continue to heat your house in the event of a power failure.
For increased efficiency, we offer as an option a 200 CFM blower with speed control and thermo-switch. Your blower will therefore turn itself on or off automatically if you desire.
Read these instructions and consult your local building authorities before installing this appliance. Install the unit and its venting system only as described in these instructions.
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
This gas fireplace has been tested by Intertek Testing Services according to CGA-2.22-M96 and CAN/CGA-2.17-M91 for Canada and ANSI Z21.50-1996 and UL307B-1995 for USA.
It is mobile home approved. This appliance must be installed in accordance with the current Standard Mobile Homes, CAN/CSA Z240 MR OR CAN/CSA Z240RV, RECREATIONAL
VEHICLES or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or when such a standard is not applicable, the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities, ANSI/NFPA 501A or
with the current Standard for RECREATIONAL VEHICLES, ANSI A119.2/NFPA 501C.
The unit can be installed in a range of altitude from 0 to 4 500 ft (0-1 370 m) in Canada. In USA see gas codes for operating above 2000 ft.
This appliance must be connected to a venting system.
Use only with Drolet Direct Vent Kit, supplied by manufacturer.
3
ULTRA FLAME DV “0” Clearance Fireplace
WARNING
INSTALLATION SHOULD BE DONE BY A QUALIFIED INSTALLER.
DO NOT BURN WOOD OR ANY OTHER MATERIAL IN THIS APPLIANCE.
HOT WHEN IN OPERATION. KEEP CHILDREN, FURNITURE, CLOTHING AND FLAMMABLE MATERIAL AWAY FROM THE APPLIANCE.
ADVISE ADULTS AND CHILDREN ABOUT THE HAZARD OF HIGH SURFACE TEMPERATURES AND THAT THEY SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.
THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A QUALIFIED SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC.
IT IS IMPERATIVE THAT THE CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS BE KEPT CLEAN.
DO NOT MODIFY THIS APPLIANCE.
THE LOUVRED OPENINGS AT THE TOP AND BOTTOM OF THE FIREPLACE SURROUND SHOULD NEVER BE BLOCKED.
PROVIDE ADEQUATE ACCESSIBILITY CLEARANCES FOR SERVICING AND PROPER OPERATION.
4
ULTRA FLAME DV “0” Clearance Fireplace
SPECIFICATIONS
Dimensions: height 39", width 36", depth 20"
Glass: 29-1/8" x 17-3/4" 1400oF clear ceramic
Minimum opening in wall for installing the units: height: 39-1/2" width: 36-1/2"
Input : 30,000/ 20,000 26,000/20,000 Btu/h Manifold pressure : 3.5/1.8 10.5/7.0 in w.c. Min. inlet pressure : 5 11 in w.c. Max. inlet pressure : 7 14 in w.c. Efficiency: 75%
Valve: SIT Model Nova 820 adjustable millivolt valve
Blower: Variable speed, 200 CFM
Maximum length of venting pipe allowed: Straight out installation: - Vertical rise: 0’
- Max horizontal length: 5'
- Max combination of both: 5’
Corner installation: - Vertical rise: 0’
- Max horizontal length: 5'
- Max combination of both: 5’
Basement installation: - Max vertical rise: 25'
- Max horizontal length: 10'
Fuel: Natural Gas Propane
Vent size: 4" inner 8" outer coaxial vent pipes
Thermo-switch: 120oF "ON", 90oF "OFF" bi-metal type
Pressure relief device: Burst disc
- Max combination of both: 25'
Maximum number of elbows 90° or 45°: 3
5
ULTRA FLAME DV “0” Clearance Fireplace
OPERATION
BEFORE LIGHTING
1) Do not use this appliance if any part has been under water. Immediately call a qualified
service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
2) Make sure that there are no obstructions in the air intake or venting system.
3) Clear the immediate area of combustible materials, gasoline, and other flammable liquids and
vapours.
4) Make sure that the gas log is in its proper place.
THE FIRST FIRE:
During the first few hours of operation the appliance will release an odor. This is caused by the burning off of residual oils used in the manufacturing process and by the curing of the high heat paint. The ceramic glass window may require cleaning after this initial "burn in." Please read the instructions on cleaning in the MAINENANCE section before doing so.
The optional gold plated items must be from your fingerprints may permanently etch the gold plating.
If the protective packaging that accompanied the gas log is still in place, follow the instructions in the LOG PLACEMENT section.
absolutely clean before you light each fire. The acid
LIGHTING PROCEDURE
WARNING: If you do not follow these lighting instructions exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
Open the pedestal cover front panel to reach the control.
Make sure the gas control knob is turned to the "off" position. If it is not, press knob slightly and turn clockwise to the "off" position. Do not force the gas control knob. If the gas control was in the on position you should wait 5 minutes before trying to re-light the fireplace.
If you smell gas STOP and follow instructions on the COVER page.
Push in and turn gas control knob counterclockwise to the "pilot" position.
6
ULTRA FLAME DV “0” Clearance Fireplace
Press gas control knob in and hold. Immediately push the red igniter button repeatedly until
pilot flame ignites. Continue holding in the control knob for 5 to 10 seconds, then release it. If the pilot flame goes out, repeat this step.
Push and turn gas control knob counterclockwise to the "on" position.
CAUTION: This fireplace is hot while in operation. Do not touch. Keep children, clothing and flammable materials away.
WALL THERMOSTAT
To operate your ULTRA FLAME using the wall thermostat, follow the lighting procedure and set the gas control to the ON position. Simply set your wall thermostat to a comfortable temperature and the fireplace will do the rest.
During the heating season, you do not have to touch the gas control valve. If you would like the fireplace off for a while, just set the thermostat to its minimum setting. However if you do not need the fireplace for quite some time, follow the procedure outlined in the SHUTDOWN section. This will extinguish the pilot light as well.
SHUTDOWN
Push in and rotate the gas control knob clockwise to the "off" position. Do not force.
If you are going to perform any maintenance or cleaning, first allow the fireplace to cool completely. Follow the instructions in the section on cleaning under MAINTENANCE INSTRUCTIONS.
BLOWER
The blower control contains a variable speed switch and a thermal switch. When the fireplace is operating, the thermal switch will turn on at 120° F, allowing the blower to operate . When the fireplace cools to 90° F, the thermal switch turns off the blower in about 40 minutes. This prevents the blower from operating when the fireplace is not in use.
The blower not only helps circulate air throughout the room, it also increases the heat output and efficiency of the ULTRA FLAME.
7
ULTRA FLAME DV “0” Clearance Fireplace
MAINTENANCE INSTRUCTIONS
TURN OFF THE GAS WITH THE SHUTDOWN VALVE AND DISCONNECT THE ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE.
The venting system and the gas fireplace should be inspected at least once a year.
Remove the glass front and the logs and clean them if necessary.
The control compartment, air circulating passages, firebox, logs and burner should be cleaned at least once a year by vacuuming or brushing.
Check the pilot flame to see if it is adjusted properly. Readjust the pilot flame if necessary (as described below) or clean the pilot orifice if readjustment is not possible.
Check the burner for flame lifting or for unusual flame pattern. If necessary clean the burner orifice. For more information, see “Adjustments” in the INSTALLATION section.
Keep the area clear and free from combustible materials, gasoline and other flammable vapours and liquids.
GLASS MAINTENANCE
We have supplied your ULTRA FLAME with special ceramic glass which will withstand the heat from the unit without cracking. Be careful not to hit the glass.
NOTE: Never clean this glass with abrasive cleaners. Use only a cleaner recommended by your dealer. Never clean glass while it is still hot. Do not operate the fireplace with the glass broken or removed
For removing your glass front see page 22.
If Your Glass Breaks:
See your dealer for exact replacement glass.
Remove front as explained above. With a 5/16” nut driver remove all nuts holding the glass
retainers. Carefully remove retainers and seal.
After removing all broken glass pieces, insert new glass and reinstall seal and brackets. It the
seal is damaged, replace it with an identical new seal from your dealer.
8
ULTRA FLAME DV “0” Clearance Fireplace
BURST DISC REPLACEMENT
If the burst disc under the burner moves from its location, it must be put back in place into the silicone seal. Make sure the switch is depressed all the way during the installation. Otherwise the appliance will not operate.
WARNING: Never glue or lubricate the disc to the silicone seal. Do not put any object under the disc.
9
ULTRA FLAME DV “0” Clearance Fireplace
TOP, FRONT AND SIDE VIEWS
FRONT VIEW TOP VIEW
SIDE VIEW
.......................................................................................................................................................................................................
10
Loading...
+ 21 hidden pages