DRIZAIR 1200, 2400 Troubleshooting Manual

DrizAir 1200/2400 Pump Troubleshooting Guide
All service procedures below are to be executed with the power off, i.e., unplugged.
Tools Required:
(1) Flathead Screwdriver (1) Q-Tip Cotton Swab
Preparation:
1. Read all pump and testing instructions carefully before checking and servicing pump on dehumidifiers.
2. Make sure you have all the parts and tools required to perform inspection, repair and upgrade as listed in these instructions.
3. Make sure the dehumidifier is disconnected from the power source before starting any of the following proce­dures.
Removing Dehumidifer Cover and Accessing Pump
4. DrizAir 1200 front cover in the following order. While unit is standing up, remove the two near the wheel axle. Place unit on its back, remove the two located on top, in front of cover. Last, remove the two located on bottom of unit near the front feet. All bolts can be identified because they are all 3/8”. Remove front cover.
DrizAir 2400: Lay unit on its back and unscrew the four 7/16” bolts on the grey bucket. Remove bucket and turn upside down. Then set the pump on it, using it as a table.
5. DrizAir 1200 power cord, and remove the two 5/16” mounting bolts lo­cated to the rear of the pump with nut driver.
DrizAir 2400 cord in place inside unit.you may not need to snip the zip tie if there is already plenty of slack in the power cord to set pump on grey bucket. The objective is to remove the pump just far enough to access the two Phillips screws [#10], one on each side of pump cover [#1].
Inspecting External Pump Components
6. With pump exposed, inspect ½” clear drain tube entering pump on right side to insure it’s properly seated into pump. If too short or kinked it may need to be replaced.
7. Pull tube out and verify bottom of tube has a 35-degree notch cut into it. This prevents a seal from occurring be­tween the hose and bottom of resourvoir tank. If seal oc­curs, water will back up in the drip tray and overflow.
8. Using screwdriver, remove pump-out tube from black check valve [#25] located on left side of pump. Be careful not to break fixture.
9. Unscrew check valve.
10. Look into the bottom of the check-valve assembly. Using needle nose pliers carefully remove bottom of check valve assembly by inserting one side of pliers approximately 1/8” into hole, grasp and pull carefully. A small bearing should fall out so be careful not to lose it. Now you can inspect for debris in assembly and clean accordingly. Clean and reinstall.
15180 Josh Wilson Road, Burlington WA 98233 •Tel: (360) 757-7776 Svc Fax (360) 757-6784 www.dri-eaz.com
PN 07-00397 Microswitch Kit Instructions - 2/28/02 1
(1) Needlenose Pliers (1) 6" x 8" piece of Cardboard
: Remove the six 3/8” bolts holding on the
, Carefully snip the zip tie holding the coiled
, Carefully snip the zip tie holding the power
Removing Pump
11. Remove pump from base by sliding to the left. While slightly lifting the silver pump shield up, pull pump up and out to left. Place piece of cardboard on top of refrigeration coils and rest pump gently on top of it, using it as a table.
12. Remove two pump cover screws [#10], and set pump cover [#1] aside.
Inspecting Internal Pump Components
13. With cover removed, visually inspect microswitch [#7]
for looseness. If loose, gently tighten screws [#8]. Note: Over tightening will cause switch to bind up inside and fail. If switch is snug and no parts missing, continue.
14. Check operation of microswitch by lifting float stem
[#15] upward, listening for the switch activation “click” sound. Then, let float stem fall on its own, listening for the “click” going downward. Switch may need adjusting or replacement if “click” doesn’t occur in both directions.
Adjustment mounting peg. If switch is tilted too far back it will not activate microswitch lever. Note: Do not bend mi­croswitch lever to compensate for unevenness. Loosen screws, adjust until level and gently re-tighten.
Replacement down direction, replace microswitch.
Note: Be careful not to over tighten mounting screws and nuts in either an adjustment or replacement switch situa­tion. Also, be sure to include two locking washers [#6] per screw, one underneath head of screw [#8] and one prior to installing hex nut [#5].
15. Inspect to insure two “C”clips [#22] on float stem are in
place, one above and one below microswitch lever.
16. Check to insure float moves freely up and down and is not
restricted. If restricted, clean float stem [#15] and access port. A Q-Tip works well for this procedure.
17. Check to see if impeller [#20] is spinning freely by spin-
ning the black plastic wheel located on top of motor.
18. Remove the remaining four Phillips screws [#10] from the
top of the pump assembly and separate it from the blue reservoir tank [#16]. (Any missing microswitch screws or nuts may be found here.)
19. Inspect bottom of reservoir tank for debris and dirt build
up. Clean accordingly.
20. Visually inspect impeller cover [#18] and gasket for
cracks, warps or exposed gasket material.
21. Remove four impeller cover screws [#17] and check for
debris in housing.
22. Assemble in reverse order. Run unit through several
pump outs to insure repairs.
DRI-EAZ PRODUCTS, INC.
: The microswitch needs to be level to its
: If switch lever hangs up in either up or
SPECIFIC PARTS LIST FOR PUMP
PART REF# ITEM DRI-EAZ
PART NUMBER
Cover - motor 154006 1 -
Fan 154031 2 -
Motor - 115v 979554 3 -
Motor - 230v 979555 4 -
Plate - Motor 154021 4 -
Nut - Hex, 2-54 920035 5 08-00300 2 2
Washer - Lock, #2 921027 6 08-00301 4 4
Switch - VC Pump 950337 7 08-00298
Screw - 2-54 x 9/16” 901600 8 08-00299 2 2
Wire Nut 950403 9 -
Screw - 8-18 x ½” 902436 10 - 16 16
Strain Relief 154038 11 -
Wiring Harness - 115v 951556 12 -
Wiring Harness - 230v 951222 12 -
Lead Wire Assembly 951982 14 -
QTY
115v
QTY
230v
PART REF# ITEM DRI-EAZ
Float/Stem Assembly 154017 15 -
Tank 154004 16 -
Screw - 8-18 x ½”, SS 902431 17 - 5 5
Volute, Impeller Cover 154015 18 -
Seal Ring, Nitrile 928006 19 -
Impeller 154009 20 -
Cover, Tank 154005 21 -
Retaining Ring - circlip 923006 22 - 2 2
Washer, Slinger 921063 23 -
Washer, Lock, #8 921015 24 - 2 2
Check Value, VC Assy
Adapter, ¼” MNPT x ¼” Hose
Plug, Drain Hole 929600 27 -
Screw, 8-32 x ½” 902421 28 -
154715 25 -
154037 26 -
PART NUMBER
QTY
115v
QTY
230v
15180 Josh Wilson Road, Burlington WA 98233 •Tel: (360) 757-7776 Svc Fax (360) 757-6784 www.dri-eaz.com
PN 07-00397 Microswitch Kit Instructions - 2/28/02 2
DRI-EAZ PRODUCTS, INC.
Loading...