Owner’s Manual
Deluxe Automatic Blood Pressure Monitor
Wrist Model
MODEL BP3200
Wrist Type
Contents
Safety Notice ................................................................ 02
Unit Illustration ............................................................... 06
Important Testing Guidelines ........................................ 09
Quick Start ..................................................................... 10
Unit Operation .............................................................. 12
Battery Installation ..................................................... 12
System Settings ........................................................ 13
Applying The Wrist Monitor ....................................... 16
Testing ....................................................................... 18
Power Off .................................................................. 23
Memory Check & Last 3 Tests Average .................... 25
Memory Deletion ....................................................... 27
Low Battery Indicator ................................................ 28
Troubleshooting ........................................................ 29
Blood Pressure Information .......................................... 30
Blood Pressure Q&A ..................................................... 34
Maintenance ................................................................. 36
Specifications ................................................................ 40
Warranty Specifications ................................................. 44
Document No.
Version: REV01.07.21.16
Drive Medical
99 Seaview Blvd
Port Washington, NY 11050
Toll-Free 877-224-0946
www.drivemedical.com
Safety Notice
1
Thank you for purchasing the BP3200 Blood Pressure Monitor.
The unit has been constructed using reliable circuitry and durable
materials. Used properly, this unit will provide years of satisfactory use.
The device is intended for used by individuals 12 years and older to
measure the systolic and diastolic blood pressure and pulse rate. All
values can be read out in one LCD DISPLAY. Measurement position is on
adult upper arm only.
Blood pressure measurement determined with this device are equivalent
to those obtained by a trained observer using the cuff/ stethoscope
auscultation method, within the limits prescribed by the American National
Standard (ANSI/AAMI Sp10) for electronic sphygmomanometers.
Precautions to Ensure Safe, Reliable Operation
1. Do not drop the unit. Protect it from sudden jars or shocks.
2. Do not insert foreign objects into any openings.
3. Do not attempt to disassemble the unit.
4. Do not crush the pressure cuff.
5. If the unit has been stored at temperatures below 0 oC, leave it in a warm
place for about 15 minutes before using it. Otherwise, the cuff may not inflate
properly.
6. Do not store the unit in direct sunlight, high humidity or dust.
7. To avoid any possibility of accidental strangulation, keep this unit away from
children and do not drape tubing around your neck.
8. Ensure that children do not use the instrument unsupervised; some parts are
small enough to be swallowed.
9. Some may get a skin irritation from the cuff taking frequent readings over the
course of the day, but this irritation typically goes away on its own after
the monitor is removed.
2
Safety Notice
Important Instructions Before Use
1. Do not confuse self-monitoring with self-diagnosis. Blood pressure
measurements should only be interpreted by a health professional who
is familiar with your medical history.
2. Contact your physician if test results regularly indicate abnormal
readings.
3. If you are taking medication, consult with your physician to determine
the most appropriate time to measure your blood pressure. NEVER
change a prescribed medication without first consulting with your
physician.
4. Individuals with serious circulation problems may experience
discomfort. Consult your physician prior to use.
5. For persons with irregular or unstable circulation resulting from diabetes,
liver disease, arteriosclerosis or other medical conditions, there may be
variations in blood pressure values measured at the wrist versus at the
upper arm. Monitoring the trends in your blood pressure taken at either
the arm or the wrist is nevertheless useful and important.
6. People suffering from vascular constriction, liver disorders or diabetes,
people with cardiac pacemakers or a weak pulse, and women who are
pregnant should consult their physician before measuring their blood
pressure themselves. Different values may be obtained due to their
condition.
3
Safety Notice
7. People suffering from arrhythmias such as atrial or ventricular
premature beats or atrial fibrillation only use this blood pressure
monitor in consultation with your doctor. In certain cases oscillometric
measurement method can produce incorrect readings.
8. Too frequent measurements can cause injury to the patient due to blood
flow interference.
9. The cuff should not be applied over a wound as this can cause further
injury.
10. Do not attach the cuff to a limb being used for IV infusions or any other
intravascular access, therapy or an arterio-venous (A-V) shunt. The cuff
inflation can temporarily block blood flow, potentially causing harm to the
patient.
11. The cuff should not be placed on the arm on the side of a mastectomy.
In the case of a double mastectomy use the side of the least dominant
arm.
12. Pressurization of the cuff can temporarily cause loss of function of
simultaneously used monitoring equipment on the same limb.
13. A compressed or kinked connection hose may cause continuous cuff
pressure resulting in blood flow interference and potentially harmful injury
to the patient.
14. Check that operation of the unit does not result in prolonged
impairment of the circulation of the patient.
15. Product is designed for its intended use only. Do not misuse in any way.
4

Safety Notice
16. Product is not intended for infants or individuals who cannot express their
Unit Illustration
Monitor Unit
intentions.
17. Any hazards associated with prolonged overinflation of the bladder.
18. Do not disassemble the unit or wrist cuff. Do not attempt to repair.
19. Use only the approved wrist cuff for this unit. Use of other arm cuffs may
result in incorrect measurement results.
20. The system might produce incorrect readings if stored or used outside
the manufacturer’s specified temperature and humidity ranges.
21. Do not use cell phones and other devices, which generate strong
electrical or electromagnetic fields, near the device, as they may cause
incorrect readings and interference or become interference source to the
device.
22. Do not mix new and old batteries simultaneously
23. Replace batteries when Low Battery Indicator "
Replace both batteries at the same time.
" appears on screen.
24. Do not mix battery types. Long-life alkaline batteries are recommended.
25. Remove batteries from device when not in operation for more than
3 months.
26. Do not insert the batteries with their polarities incorrectly aligned.
27. Dispose batteries properly; observe local laws and regulations.
28. Refer to instruction manual/ booklet symbol.
29. Refer to keep dry.
Unit Illustration Unit Illustration
ContentsDisplay
Time
Date
1 2
AVG
(
( )
/
)
mmHg
No
kPa
Systolic
Blood
Pressure
Diastolic
Blood
Pressure
Pulse
Rate
2. Owner’s Manual
Groups
Low Battery Indicator
WHO Blood Pressure
Classification Indicator
Last 3 Results Average
Irregular Heartbeat Indicator
World Health Organization (WHO)
Blood Pressure Classification Indicator
LCD
Systolic Blood Pressure
SYS
g
mmH
SET
Diastolic Blood Pressure
DIA
mmHg
PLU
in
/m
M
T
R
TA
S
P
STO
Pulse Rate
“M” Button
“ START/STOP “ Button
“ SET “ Button
Wrist Cuff
YS
S
mHg
m
DIA
Hg
mm
U
L
P
n
i
m
/
M
START
STOP
SET
1. Monitor Unit
Important Testing Guidelines Quick Start
1. Avoid eating, exercising, and bathing for 30 minutes prior to testing.
2. Sit in a calm environment for at least 5 minutes prior to testing.
3. Do not stand while testing. Sit in a relaxed position while keeping your
wrist level with your heart.
4. Avoid speaking or moving body parts while testing.
5. While testing, avoid strong electromagnetic interference such as
microwave ovens and cell phones.
6. Wait 3 minutes or longer before re-testing.
7. Try to measure your blood pressure at the same time each day for
consistency.
8. Test comparisons should only be made when monitor is used on the
same wrist, in the same position, and at the same time of day.
9. This blood pressure monitor is not recommended for people with severe
arrhythmia.
10. Do not use this blood pressure monitor if the device is damaged.
1. Install 2x AAA batteries. (See Figure A )
Figure A
2. Remove clothing from the wrist area. (See Figure B)
3. Rest for several minutes prior to testing. Wrap cuff around
left wrist. (See Figure C)
Figure B Figure C
1-2cm ''(0.4-0.8 )
3. Plastic Storage Case
S
E
T
S
T
S
A
T
R
O
T
P
S
mmHg
Y
S
D
mmHg
I
A
P
M
U
/
min
L

Quick Start
4. Sit in a comfortable position and place wrist level with heart.
(See Figure D)
5. Press “ START/STOP ” button to start testing. (See Figure E)
SYS
mmHg
DIA
mm
Hg
PU L
/mi
START
SET
Figure D Figure E
M
STOP
Unit Operation
Battery Installation
Slide battery cover off as indicated by arrow.
Install 2 new AAA alkaline batteries according to polarity.
Close battery cover.
n
Note:
1) Replace batteries when Low Battery Indicator “ ”
appears on screen.
2) Batteries should be removed from device when not in
operation for an extended period of time.
Unit Operation
System Settings
With power off, press "SET” button to activate System Settings.
The Memory Group icon flashes.
1. Select Memory Group
While in the System Setting mode, you may accumulate test results
into 2 different groups. This allows multiple users to save individual
Unit Operation
2. Time/ Date Setting
Press "SET” button again to set the Time/Date mode. Set the year first
by adjusting the " M " button. Press " SET " button again to confirm
current month. Continue setting the day, hour and minute in the
same way. Every time the " SET " button is pressed, it will lock in your
selection and continue in succession (month, day, hour, minute.)
test results (up to 60 memories per group.)
Press “ M ” button to choose a group setting. The test results will
automatically store in each selected group.
1 2
Unit Operation Unit Operation
3. Time Format Setting
Press “ SET “ button again to set the time format mode. Set the time
format by adjusting the “ M “ button.
EU means European Time. US means U.S. Time.
Applying The Wrist Monitor
Do not apply over clothing. If wearing a long sleeved shirt, be sure to roll
sleeve back to forearm.
Apply monitor to wrist as illustrated. Tighten cuff firmly as not to wiggle.
/
//
4. Save Settings
While in any setting mode, press “ START/STOP “ button to turn the
unit off. All information will be saved.
Note: Unit will automatically save all information and shut off
if left for 3 minutes.
1-2 cm ''(0.4-0 .8 )
SET
ST
S
TOP
ART
SYS
mmHg
D
mmHg
I
A
P
M
U
/min
L