Dri-Eaz Velo, F505, F504, Velo Pro Owner's Manual

Owner’s Manual
Fig. B: Operating Positions
Horizontal (for
horizontal surfaces)
Vertical (for walls and
ceilings)
Right edge (for
wall drying)
Left edge (for wall
drying)
With stand for stairwells
(Pro model only)
Rear cord wrap under
Pro: Variable speed Stand folds o ut
Inlet grill. Keep clear of Outlet grill. Kee p clear
of obstructions.
Velo: On/Off and circuit
GFCI-protected power
Carry strap
Fig. A: Parts Identification
Front Lift/Cord Wrap tab.
Velo™ & Velo™ Pro Low Profile Airmover
Models F504 & F505 115V
DRI-EAZ PRODUCTS, INC.
15180 Josh Wilson Road, Burlington, WA 98233, USA
The Velo Airmover produces a high rate of airflow to accelerate the
evaporation of moisture from materials for restorative drying.
Patents: http://www.LBpatents.com
READ AND SAVE THESE INSTRUCTIONS
WARNING! To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
WARNING! Unit must be grounded. Do not use with an extension cord. Connect only to an outlet provided with a ground fault interrupting device.
WARNING! Never operate a unit with a damaged power cord, as this may lead to electrical or fire hazards. If power cord is damaged, it must be replaced by a cord of the same type and amperage rating.
WARNING! Do not touch grills when unit is operating. NOTICE: Keep motor dry. For indoor use only. NOTICE: Unplug when not in use or when moving unit. NOTICE: Do not allow children to play with or around the unit.
Be sure the unit is inaccessible to children when not attended. NOTICE: Always operate the unit on a stable, level surface so it
cannot fall and cause injury.
Wrap cord counter-
obstructions.
clockwise and secure with plug clip.
WARNING! Do not alter or modify your Velo in any way. Use only replacement parts authorized by Dri-Eaz Products, Inc. Modifications or use of unapproved parts could create a hazard and will void your warranty. Contact your authorized Dri-Eaz distributor for assistance.
WARNING!
a) Do not operate any fan with a damaged cord or plug. Discard fan or return to an authorized service facility for examination and/or repair.
b) Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
BEFORE YOU BEGIN
Warranty registration
Please visit warranty.drieaz.com to register your purchase. Registration allows us to better assist you with using, maintaining
control with amp readout
outlet sockets with reset switch.
bottom edge. Wrap cord counter-clockwise and secure with plug clip.
07-01837E F504/F505-115V 1 Dri-Eaz Products, Inc.
and wall drying
breaker reset switches
and locks (Pro only).
or servicing your equipment and to contact you in case we have

Fig. C: Disassembly

with amp and total unit hours display
To disassemble for
1. Remove impeller
2. Remove base
important safety information concerning your Dri-Eaz product. If you determine service is required, have your equipment model, serial number and original proof of purchase available and call your distributor for assistance with obtaining a return material authorization (RMA).

OPERATING INSTRUCTIONS

Note that the Velo can be placed in a variety of positions for drying and air circulation. See Fig. B for details.
1. Unwrap the cord and plug the unit into a standard 115V
GFCI-protected outlet. CAUTION: Be sure switch is in the off position before connecting unit to power outlet.
2. Direct the Velo outlet toward the surface to be dried. TIP: On the Velo Pro (F505), the airflow may be adjusted by
pressing the Up or Down arrow on the speed control (Fig. D). A digital readout shows the approximate amp draw. Use this value to maximize the number of Velos you can place on a single circuit.
3. When surface is dry to the touch, switch the unit off and
reposition the unit in the next area to be dried.
4. When finished, unplug the unit and re-wrap the cord in the
cord wrap.
For additional instructions about the use of airmovers for restorative drying, visit www.DriEaz.com
and
www.RestorationSciencesAcademy.com.
Electrical safety devices
Circuit breaker: If the circuit breaker detects overload or short
circuit conditions, the breaker will automatically shut off the electrical supply. If this should occur, check the power cable carefully for any damage and ensure it is plugged into a properly grounded outlet. Press the “Circuit Breaker Reset Switch (Fig. A) to reestablish the electrical supply.
Ground Fault Circuit Interrupter: If the GFCI device detects a ground fault, it will automatically shut off the electrical supply. If this should occur, check the power cable carefully for damage and ensure it is plugged into a properly grounded outlet. Press the GFCI reset button (Fig. A) to reestablish the electrical supply.

TRANSPORT AND STORAGE

Always use the handle to load or carry the unit. Wrap cord in a counter-clockwise direction under front Cord
Wrap tab and rear bottom edge (Fig. A). Pull cord snug and secure with plug clip.
Units may be stacked for transport and storage. When transporting in a vehicle, secure the unit(s) carefully to
prevent sliding and damage to the unit and/or injury to vehicle occupants.
Keep unit dry. Do not expose the unit to rain or snow.
screws (×6) and
cleaning, first remove the
four screws from the impeller assembly 1) (below), then turn the unit on its top and 2) remove the six screws from the base. Lift off the housing. Retain screws and washers for reassembly.
assembly screws (×4).
lift out housing.
Fig. D: Pro model: Variable speed control

Maintenance

WARNING: Unplug unit before performing any maintenance.
Before each use
Inspect the power cord. If cord is damaged, do not use. Always grasp the plug (not the cord) to unplug.
As needed
Clean housing and impeller. If dust accumulation is visible, remove the four screws from the top, then turn the unit on its top and remove the six fasteners from the bottom as shown (Fig. C). Lift off the housing. Clean imp eller as se mbly with pressurized air and/or with a soft cloth. Do not apply liquids to the impeller assembly. The housing may be cleaned with a mild solution of detergent and warm water. Ensure housing is completely dry before reassembling.
07-01837E F504/F505-115V 2 Dri-Eaz Products, Inc.
FOR SERVICE CALL YOUR LOCAL DISTRIBUTOR or the Dri-Eaz
Dimensions (D × W × H)
24 × 18 × 9 in. 61 × 45.7 × 22.9 cm
24 × 18 × 9 in. 61 × 45.7 × 22.9 cm
Velos per 15 amp circuit
885 CFM | 1504 CMH
(min.)
On/Off switch w i th Variable speed
Service Department at 800-932-3030.
Be sure to visit warranty.drieaz.com and register your purchase. Your registration will help us provide you with updated product information as needed.
SPECIFICATIONS
Model Velo (F504) Velo Pro (F505) Weight 21 lbs. | 9.52 kg 21 lbs. | 9.52 kg
Amp draw 1.9 amps (115V) 1.2 – 1.9 amps (115V)
Up to 6 Up to 10
Power 185W 185W
Air movement 885 CFM | 1504 CMH
Static pressure 1.65 in. (H2O) 1.65 in. (H2O) Sound level (avg.) 69 dB 69 dB
Control On/Off switch Cord length
Fan
Construction
Safety
Specifications are subject to change without notice. Some values may be approximate.
15 ft. | 4.6 m 15 ft. | 4.6 m 6 blades 6 blades Rotomolded
polyethylene and injection molded ABS housing components; steel wire inlet and outlet grills.
ETL tested to UL and CSA standards
(max.) 500 CFM | 850 CMH
Rotomolded polyethylene and injection molded ABS housing components; steel wire inlet and outlet grills.
ETL tested to UL and CSA standards
07-01837E F504/F505-115V 3 Dri-Eaz Products, Inc.