Dri-Eaz Turbovent 48 Owner's Manual

.
OWNER'S MANUAL
SAFETY • WARRANTY
OPERATING INSTRUCTIONS • MAINTENANCE
TURBOVENT 48
INTERAIR DRYING SYSTEMS
For Walls, Floors, and Other Structural Areas
DEALER: ________________________________________________________________________________________________________________
THIS MANUAL CONTAINS IMPORTANT SAFETY WARNINGS. PLEASE READ THESE WARNINGS
BEFORE USING THE TURBOVENT AND SAVE THIS MANUAL FOR FUTURE REFERENCE.
TURBOVENTS
DRI-EAZ PRODUCTS • 15180 Josh Wilson Road, Burlington, WA 98233 • www.dri-eaz.com • (360) 757-7776
TABLE OF CONTENTS
SAFETY INFORMATION......................................... 2
WARRANTY........................................................... 2
PRINCIPLES OF OPERATION ................................ 3
INSTALLING A TURBOVENT 48 ............................. 3
INSTALLING MINI-TURBOVENTS........................... 4
APPLICATION #1 –
DRYING WALL INTERIOR CAVITIES ................ 4
APPLICATION #2 –
DRYING WALL & CEILING SURFACES............. 5
APPLICATION #3 –
DRYING CEILING CAVITIES............................. 7
APPLICATION #4 –
DRYING WITH DUCTED AIR ............................ 7
APPLICATION #5 –
DRYING HARDWOOD FLOORS ....................... 7
MAINTENANCE.....................................................11
MOISTURE CONTENT MAP .................................11
Congratulations on your selection of the TurboVent 48 or Mini-TurboVent system for drying walls, floors and ceilings. It is our goal at Dri-Eaz Products to offer you a product that will provide a profitable return on your investment. We invite your written appraisal and suggestions for improvements. Reading this Owner's Manual will help you achieve maximum results when drying structures. This manual uses the word “TurboVent” to mean both the Turbo­Vent 48 and Mini-TurboVents.
SAFETY INFORMATION
We strongly advise that you read your TurboDryer Owner’s Manual before operation. Please pay particu­lar attention to the safety information.
Failure to observe the safety warnings in your manual can result in injury to persons, fire damage, or damage to the TurboDryer. To reduce the risk of electrical shock, fire, or personal injury, read and follow each of the warnings in your manual before using TurboDryers.
Keep TurboDryers Grounded: Always operate TurboDryers with the three pronged grounding plug and a grounded electrical outlet. Never remove the three pronged plug, use an ungrounded extension cord, or use an ungrounded adapter. The grounding pin on the TurboDryer’s plug is an essential safety feature that
helps reduce the risk of shock or fire in the event of an electrical hazard.
Keep Children Away: Do not allow children to
play with or around the TurboDryers. Be sure that TurboDryer is inaccessible to children when left unattended. Secure all areas in which TurboDryers are left unattended while running.
CAUTION
Only TurboDryers from Dri-Eaz Products, Inc. can be used with TurboVents. Other brands of airmovers have not been tested by Dri-Eaz and may experience a motor temperature rise that is unsafe in high pressure applications. Dri-Eaz claims no responsibility if the TurboVent is used with other than Dri-Eaz Turbo­Dryers. The Snout Adapter for Mini-TurboVents fits only the Sahara TurboDryer.
WARRANTY
One Year Warranty: Within one year of purchase, Dri-Eaz promises to the original purchaser to repair or
replace any TurboVent 48 or Mini-TurboVent that is defective in material or workmanship. During this warranty period, Dri-Eaz Products, Inc. is responsible for the costs of labor, material and shipping, required to repair or replace the TurboVent. After 90 days, the customer is responsible for shipping costs to Dri-Eaz Products and labor at the prevailing hourly rate.
This warranty does not include normal wear and tear to ducting or other parts. This warranty shall not extend to any products showing effects of misuse, alteration, corrosive chemicals, accident damage, fire, normal wear, or any other causes beyond Dri-Eaz Products' control.
Dri-Eaz Products, Inc. is not responsible for any work performed or repairs effected upon any of its products, by other than Dri-Eaz Products, Inc. or authorized dealer personnel.
To receive warranty service, you must call for a Return Authorization. No replacement item will be shipped without an Authorization Number. No credit will be made until the defective item is received.
The foregoing constitutes the entire warranty and no other warranty, liability, contingency or responsi­bility, direct, indirect, consequential or in any way connected with the sale or operation of equipment products is expressed or implied.
Direct warranty questions to an authorized dis-
tributor or Dri-Eaz Products, Inc. at (360) 757-7776.
PRINCIPLES OF OPERATION
The TurboVent is a wall and floor drying accessory for Dri-Eaz TurboDryers. It is designed to increase the rate of evaporation from slow drying areas. Using it, you can achieve faster, more complete structural drying while reducing damage to finished materials like hardwood flooring or painted and papered walls.
INSTALLING A TURBOVENT 48
Whether drying walls, ceiling surfaces or floors, the TurboVent 48 is intended for use on the floor located against a flat wall surface. Wall moldings and baseboards must be removed to allow the vent opening to fit flush against the wall. The TurboDryer must be unplugged and turned off while attaching TurboVents.
NOTE
piece of foam pad under the base of the TurboDryer.
Attaching the TurboVent 48 to a TurboDryer
1. Remove baseboards and moldings, and drill holes (see Application #3.) In most cases, it is not necessary to remove carpeting.
2. Place TurboVent firmly against the wall so that oval snout points away from the wall.
3. Attach the TurboVent to the TurboDryer by sliding the TurboVent oval opening into the TurboDryer snout. The TurboVent opening should fit snugly.
: To avoid marring hard surface floors, place a
Three primary methods of installing the TurboVent 48. Mini-TurboVents can be used in the same ways.
1. Airflow can be directed under hardwood flooring for subsurface drying.
2. Airflow can be directed across wall surfaces; it will travel up the walls and across ceilings to dry both.
3. Airflow can be used to dry the interior cavities of walls by directing airflow up the inside of walls via openings cut at the baseboard level.
The principle of operation is to direct high volume airflow from a TurboDryer across, under, or into wet areas or surfaces. This airflow speeds evaporation as it removes the cushion of moisture-laden air that hangs near any wet surface.
This moist air is whisked away and dry (lower humidity) air replaces it. This constant process of removing moist air and replacing it with dry air draws moisture out of permeable materials and significantly speeds drying time. This reduces water damage to floors, walls, and ceilings.
It is highly recommended that Dri-Eaz commercial grade dehumidifiers be used in the area being dried. The moisture that is moved away from the wet materials should also be removed from the air. Dri-Eaz dehumidifiers do this as they rapidly lower humidity. Reducing the humidity is an important factor in speeding up the drying process.
Attaching TurboVent 48 to TurboDryer.
4. There are two positions to use TurboVents. Make certain that the TurboVent is in the correct position with the air opening facing up or down as appropriate.
Floor Drying: When drying floor or wall cavities, the
TurboVent label should be facing up.
Wall Drying: When drying exterior wall surfaces, the
TurboVent should be inverted so that the label is facing down toward the floor.
5. When using the TurboVent in a room with an unfinished floor, a 2" block of wood nailed to the floor will help maintain the TurboDryer in position.
6. Or, when on a finished floor, secure the TurboDryer and TurboVent to the wall using two 1/2" eye screws and a stretch bungee cord. The eye-screws should be attached to the wall below baseboard level.
INSTALLING
MINI-TURBOVENTS
Installation procedures for Mini-TurboVents are similar to those for the TurboVent 48. Remove mold­ings and baseboards as needed to allow the vent openings to fit flush against the installation surface. The TurboDryer must be unplugged and turned off while attaching Mini-TurboVents.
Attaching to a Sahara TurboDryer
Place Mini-TurboVent firmly into position. Be sure each Mini-TurboVent is in the correct position with the air opening facing up to dry walls with a sheet of air, or down when forcing air into wall cavities or under hardwood floors.
Typical Mini-TurboVent installation.
Each Mini-TurboVent can be fastened to a wall, ceiling, or built-in using drywall or other type screws. When attaching to a wall, angle the screws downward so they enter the sill plate. The holes will be covered when you replace the baseboard or cove base.
Clip hooks to the grill. When not using an outlet, cover with vinyl cap and a duct clamp.
The Adapter is fastened to the snout of any Sahara
TurboDryer by two hooks with springs.
If the TurboDryer has a wire grill (#1), position the hooks so they are pointed horizontally, or side-to-side. Fit the Adapter over the snout. Press the black knobs so the hooks go slightly inward and hook onto the ring of the grill for strongest attachment.
If the TurboDryer has a plastic grill (#2), position the hooks so they are pointed vertically, or up-and­down. Fit the Adapter over the snout. Press the black knbs so the hooks fasten to any part of the grill.
The Adapter fits very snugly over the snout of the TurboDryer to minimize air leakage.
Cut ducting to fit the job situation. 50 feet of standard 4-inch residential dryer ducting (also available locally at hardware stores) is included. For example, the 50-ft. piece could make two 20-ft. plus one 10-ft. sections, or two 15-ft. plus one 20-ft. sections. Attach ducting with regular duct clamps (six provided) that adjust with a screwdriver or nutdriver.
Using Mini-TurboVents in Series
Up to 9 Mini-TurboVents may be connected in series from one TurboDryer – 3 from each outlet from the snout adapter. (In the drawing above, two are connected to one outlet.)
When properly hooked up, the actual airflow into wall cavities or under hardwood floors is not great, since the holes into which the air must flow are small. This is the reason why up to 9 may be connected at one time.
However, a higher static pressure TurboDryer (such as the 1-hp. Sahara Pro, generating 3.0") will give better results than one with lower static pressure (such as the .4-hp Sahara, generating 1.5").
If using just one or two pieces of ducting, cover the unused outlet(s) of the snout adapter with a vinyl cap and duct clamp to prevent the escape of air.