15180 Josh Wilson Road, Burlington, WA USA 98233
Fax: (360) 757-7950 Phone US: (360) 757-7776
www.dri-eaz.com
Owner’s Manual
Sahara ProX3 (115V Model)
Patents:
http://www.LBpatents.com
READ AND SAVE THESE INSTRUCTIONS
WARNING
ELECTRIC SHOCK HAZARD
This unit must be electrically
grounded
Use only on GFCI protected
receptacles
The power cord is equipped with a 3prong grounding plug. Use only with a matching receptacle.
Do not cut off the grounding prong.
Do not use an adapter.
Do not use with a damaged power
cord.
Do not use an extension cord.
To reduce risk of fire or electric shock,
do not use this airmover with any solid
-state speed control device.
NOTE: Humidity will rise with the use of
TurboDryers because they lift moisture
from wet materials into the air. To learn
about managing humidity during drying,
contact your local distributor or call DriEaz Education at 800-575-5152.
PLACING YOUR TURBODRYERS
When drying the interior of a building, use at least one TurboDryer
per water-damaged room, or one every 200 square feet. Try to get
airflow to all wet surfaces. Open interior doors to improve air circulation, and brace doors to prevent them from blowing shut.
WARNING
Do not move or carry a TurboDryer while under operation. When the unit
is in motion, the powerful airflow is hard to control, and can produce
rapid and unpredictable movement.
Do not allow children to play with or around TurboDryers. If they lift or
get a unit off balance, the powerful airflow can cause the TurboDryer to
move rapidly, risking injury.
Do not alter or modify your Dri-Eaz product in any way. Use only replacement parts authorized by Dri-Eaz Products, Inc. Modifications or
use of unapproved parts could create a hazard and will void your warranty. Contact your authorized Dri-Eaz distributor for assistance.
OPERATING YOUR TURBODRYER
1. Locate the electrical cord and plug into a standard 3-prong outlet.
2. Set the switch to the desired speed, based on amp draw as listed
by the switch on the side control panel.
HE AUXILIARY OUTLET
T
You can “daisy chain” or interconnect up to three Sahara Pro X3 units
to customize your drying needs. The unit can conduct a maximum of
12 amps when it is turned off or 8 amps when it is turned on.
ED CIRCUIT BREAKER SWITCH
R
The primary purpose of the circuit breaker is to protect the machine. It
turns the unit off when more than 12 amps are run through the on-unit
circuit.
ROUND FAULT CIRCUIT INTERRUPTER
G
The GFCI protects the user. Should it detect a sudden “ground fault,”
the GFCI will interrupt the electric current. The GFCI will also trip
when a short circuit or overload occurs. If the GFCI “trips,” unplug the
unit and look for potential hazards (standing water, frayed cord, etc.)
that might cause an electrical surge. Relocate the unit and plug into a
different outlet. Then push the “Reset” button and check to make sure
it is operating. If so, continue use; if not, call a Dri-Eaz tech specialist
at 800-575-5152.
07-01537D F351-120V 2013-05 Warranty 07-00419 1 Dri-Eaz Products, Inc.
1
READ AND SAVE THESE INSTRUCTIONS
WARNING
ELECTRIC SHOCK HAZARD
Keep motor and electrical parts
dry.
Do not operate in standing water.
Do not expose to rain, water or
snow.
Do not get the exterior, motor or wir-
ing wet.
Do not clean with wet objects, i.e.,
power washers, soap and water, etc.
If motor or electrical parts become
wet, allow them to dry completely
before using.
Read and understand manual before operating.
COOLAND VENTILATE
Place the airmover on a flat surface, and direct the air from cooler
areas (including the outdoors) into a warm room.
TURBODRYER STORAGE
Stackable
Units can be stacked (up to 3) on their sides
for storage.
NOTICE
Stacking feature is not secure enough to
be used during transport.
WARNING
Always disconnect the TurboDryer from its
power source before performing any maintenance or cleaning.
WARNING
FIRE HAZARD
Keep air intakes clear. Reduced
airflow can cause motor to overheat.
Clean any lint or other material
from the screens before each use.
Do not operate near draperies or
other material that could block the
air intakes.
Clean dust and dirt from motor
using a vacuum or compressed air.
Do not use or store where flammable vapors like gasoline, solvents, or
thinners are present.
Do not use near open flames, or
heat sources.
Read and understand manual before operating.
Preventive Maintenance
Routine maintenance can significantly increase the life of your TurboDryer. It also promotes efficient operation. The applications and
amount of use by owners vary, so the recommendations listed below
are for average-to-high-volume use in water damage. Constant operation or use in other environments may require additional maintenance.
Contact Dri-Eaz for more information.
NOTE: Do not oil motor bearings; they are permanently oiled.
EFORE EACH USE:
B
Inspect power cord for cuts, fraying or damage; do not use if dam-
aged.
Remove lint or obstructions from the grills using a vacuum or com-
pressed air.
Inspect exterior components (switch, knob, etc.) for damage.
Q
UARTERLY (ORASNEEDED):
Clean the exterior with a household all-purpose spray cleaner.
Spray the rag, then apply to the surface.
To renew shine on the plastic, use a vinyl cleaner.
Remove grill and blower, then blow off internal components with
compressed air.
A
NNUALLY:
Inspect components and internal wiring for discoloration, loose con-
nections, or fraying.
07-01537C 2013-01 Warranty 07-00419 2 Dri-Eaz Products, Inc.
2
Important Safety Instructions:
TurboDryer from its power source before performing
any maintenance or cleaning.
Always disconnect the
TO CLEANINTERIOR (ASNEEDED):
To remove grill and blower wheel:
1. Use a Phillips #2 screwdriver to remove 2 screws.
2. Remove inlet grill
3. Loosen the blower wheel shaft nut (3/8” socket driver)
Note the backstop for ensuring alignment when replacing wheel.
4. Pull the blower wheel out of the unit.
.
5
2
3
To remove control panel and motor:
Rotate the unit onto its side so that the controls are facing up.