Dri-Eaz Vortex, Santana SX, Rebel EX, Sahara, Sahara Pro Owner's Manual

...
Owner’s Manual – Dri-Eaz TurboDryers
230-volt Models
Vortex, Rebel EX, Santana SX, Sahara, Sahara Pro, Sahara Pro-HP
DRI-EAZ PRODUCTS, INC.
15180 Josh Wilson Road, Burlington, WA USA 98233
Fax US: (360) 757-7950 Phone US: (360) 757-7776 Phone UK: (01908) 562611 www.dri-eaz.com
TurboDryers are high-performance airmovers for speed-drying of building structures and contents.
They are designed for a balance of static pressure and airflow, as well as durability and ease of use.
Keep Air Intakes Clear: Do not clog or block air intakes, as
Safety Information
Keep Children Away: Do not allow children to play with or around the unit, which could result in injury. Be sure the unit is inaccessible to children when not attended.
Keep Unit Grounded: Always operate the unit with a grounding plug and a grounded electrical outlet. A grounding plug is an essential safety feature that helps reduce the risk of shock or fire.
Protect Power Cord from Damage: Never operate a unit with a damaged power cord, as this may lead to electrical or fire hazards. If the power supply cord is damaged, it must be replaced by a cord of the same type and amperage rating.
may occur if operated to close to draperies or similar materials. This may cause the unit to overheat and result in a fire or electrical hazard.
Keep Out Dust and Dirt: Do not allow dust, dirt, or other particles to be drawn into the air intakes. Dirt in the motor can cause it to overheat, resulting in a fire or electrical hazard. If the motor gets dirty, clean it using an air hose.
Allow Repair Only by Qualified Person: Do not attempt to disassemble or repair the unit if you are not qualified to do so. You may handle some maintenance and troubleshooting, but make sure that more complex problems are handled by an authorized service technician. For information about authorized repair, call Dri-Eaz at (360) 757-7776.
Extension Cords: Extension cords must be grounded and able to deliver the appropriate voltage to the unit.
When Using Outdoors: When using outdoors, connect only to an outlet provided with a Ground Fault Interrupting (GFI) device, and do not use an extension cord, to reduce the risk of electrical shock. Do not expose to rain.
Do Not Use Speed Control Device: To reduce the risk of fire or electric shock, do not use TurboDryers with a solid­state speed control device.
Handle With Care: Do not drop or throw the unit. Rough treatment can damage the components or wiring and create a hazardous condition.
Run on Stable Surface: Always operate the unit on a stable, level surface, like the floor or a strong counter, so it cannot fall and cause injury.
Secure During Transport: When transporting in a vehicle, secure the unit to prevent sliding and possible injury to vehicle occupants.
Keep Out of Water: Never operate the unit in pooled or standing water, as this may create a risk of injury from electrical shock. Do not store or operate outdoors. If elec­trical wiring or components become wet, thoroughly dry them
HOW TO USE TURBODRYERS
TurboDryer airmovers are designed to blow air across wet surfaces for speed drying. They are especially good for drying floors because they create a flat ribbon of air. High­volume airflow will increase the rate of evaporation, help prevent mould growth, and reduce the risk of additional moisture damage. Moving air will improve evaporation by re­moving a boundary layer of saturated air that hangs near wet surfaces. TurboDryers whisk away this moist air and replace it with dryer air.
Positioning TurboDryers
When drying in a building, place at least one TurboDryer per room, or one for every 200 square feet. Place as many as needed for maximum airflow across all wet areas of the floor.
Ensure that all wet surfaces receive good airflow. Open inter­ior doors to maintain good air circulation. Doors may need to be braced to prevent them from blowing shut.
Control the Humidity
Using TurboDryers to speed the rate of evaporation in a building usually causes the humidity to rise immediately.
used with adequate dehumidification. To help control mould growth, keep indoor humidity below 60% Rh. If possible, maintain indoor humidity below 45% Rh. This may require the use of DrizAir Refrigerant Dehumidifiers. Even lower humidity (25-40% Rh) will speed the drying of dense materials such as lumber, and is possible with Dri-Eaz Desiccant Dehumidifiers.
To improve drying, close off the area being dried from the rest of structure. Regulate the heating or air conditioning system at 68-80°F (20-27°C). When dehumidifiers are not available, run exhaust fans in the attic, kitchen and bathroom to remove some humidity. If outdoor air is very dry, open some windows or doors at least slightly. Use a thermo­hygrometer such as the DHT200 or DHT600 to determine the relative humidity.
Check if Materials are Dry
Monitor the moisture condition of wet materials with moisture meters like the HydroSensor, Moisture Counter, and Mois­ture Pro. To check how completely materials have dried out, compare your readings to readings you take on similar materials you know are dry.
grounded and that all safety precautions are taken.
MAINTENANCE
Always turn off the power before performing maintenance procedures. All the service procedures below are to be executed with the unit unplugged. Perform before each use or as needed.
INSPECT ELECTRICAL SYSTEM: Inspect the electrical cord for damage at regular intervals. Periodically, remove the housing and inspect internal wiring for bare wires, insecure fasteners, and discoloration. Remove and repair any dam­aged wiring as needed. Failure to do so may lead to electrical shock or a fire hazard.
CLEAN AIR INTAKES: Clean off any accumulated lint or other materials from the air inlet side-screens. A buildup will reduce the airflow and may cause the motor to overheat and become a fire hazard.
CLEAN EXTERIOR: Clean the housing with mild detergent and water. Bring back the original shine with a vinyl cleaner and polish like those used on automobile plastics.
Cooling & Ventilation
Over-heated rooms can be cooled with high-volume airflow from a TurboDryer. Place the airmover on the floor or other flat surface and direct the air from cooler areas or the out­doors. Use the kickstand or the 45-90 degree tilt feature to elevate the snout and circulate cool air throughout the room.
OPERATING INSTRUCTIONS
1. Plug in to a standard outlet with the correct voltage and amperage for the unit. Set the switch at the desired speed. Check for proper operation before leaving the unit unattended.
2. Do not move or carry the TurboDryer when it is running.
ELECTRICAL CONNECTIONS
TurboDryers are designed to operate on a 230V/50 Hz electrical connection. Make sure that the electrical outlet is
EXTERIOR INSPECTION: Evaluate exterior components and make sure they are properly installed. Listen to the unit for abnormal sounds. Repair or replace components as needed.
Periodic Maintenance (as needed)
Make sure unit is unplugged and the wheel has stopped. Remove four screws to remove each side screen. This will permit access to motor and wheel for cleaning.
CLEAN COMPONENTS: Use compressed air or a vacuum to remove lint and dust from blower wheel, motor and side screens.
DO NOT WET MOTOR OR WIRING: To prevent damage to electrical components, do not use a hose or pressure washer to clean a TurboDryer. If electrical components do become wet, dry them immediately.
MOTOR BEARINGS: The bearings on all Dri-Eaz Turbo­Dryers are permanently lubricated. Do not oil.
Loading...
+ 2 hidden pages