The Dri-Eaz® LGR 6000Li dehumidifier reduces humidity in enclosed environments by removing
water vapor from the air. The 6000Li is rugged, durable and highly portable, making it ideal for
water damage restoration, structural drying, construction, and other applications requiring
temporary, high-performance dehumidification.
Patents: http://www.LBpatents.com
SAVE THESE INSTRUCTIONS
• Inspect the power cord before use. If cord is
SAFETY INSTRUCTIONS
WARNING! Do not alter or modify your dehumidifier
in any way. Use only replacement parts authorized
by Dri-Eaz Products, Inc. Modifications or us e of
unapproved parts could create a hazard and will
void your warranty. Contact your authorize d
distributor for assistance.
WARNING! Electric shock hazard, rotatin g fan, hot
surface hazards. Unplug unit before open ing cover
for cleaning or servicing. Unit must be grounded.
Grasp IEC plug and pull straight out
damaged, do not use. Always grasp the plug (not
the cord) to unplug.
• Insert three-prong plug on power cord into a
matching electrically grounded outlet. Do not use
adapter. Never cut off third prong. Do not use an
extension cord.
• The unit must be operated on a 115V/60Hz circuit
protected by a Ground Fault Circuit Interrupter
(GFCI) device.
• Keep motor and wiring dry.
• Do not attempt to repair the unit. For Authorized
Service Centers, contact Dri-Eaz.
BEFORE YOU BEGIN
Warranty registration
Visit warranty.drieaz.com to register your purchase.
Registration allows us to better assist you with using,
maintaining or servicing your equipment and to contact
you in case we have important safety information
concerning your Dri-Eaz product. If you determ ine
service is required, have your equipment model, serial
number and original proof of purchase available and call
your distributor for assistance with obtaining a return
material authorization (RMA).
IMPORTANT: Damage to IEC receptacle or
dehumidifier resulting from improper removal
of the power cord is not covered by warranty.
The IEC power cord is a wear item and is not
07-02300B F600 1 Dri-Eaz Products, Inc.
CONTROLS AND OPERATING
INSTRUCTIONS
Set unit upright
NOTICE: Transporting or storing the unit in a
horizontal position is not recommended. When the
machine is placed in a horizontal position, th e oil
from the compressor can flow into the refrigerant
coils and reduce the ability of the dehum idifier to
function and possibly damage the unit. If the unit
has been placed in a horizontal position, set it
upright and let it stand for at least 30 mi nu tes before
turning it on.
Drain hose
Power cord
socket.
Model serial
FRONT
REAR
Humid air inlet.
Power cord and
Process (dehumidified)
air outlet.
Front panel. Remove to
Integrated handle. Us e the
for loading or storage.
Control panel.
FIG A: PARTS IDENTIFICATION
Drain hose quick-
Extend handle
Release the handle by rotating red locking
lever outward, then lift handle up into place.
Rotate red lever back into locked position to
secure handle in operating position.
drain hose
storage.
Air filter.
quick-connect.
access the pump and
coils for cleaning. S ee
Fig. B.
red lever to lock handle
upright for use or down
NOTICE: Do not use the extended handle to
lift the unit off the ground horizontally. Do not
use the extended handle as an attachment
point to strap the unit in a vehicle for
transport. These uses will place undue strain
on the handle attachment points in the
housing.
Set up drain hose
This unit automatically pumps out water on a
regular basis. This dehumidifier is equipped
with a quick-connect fitting for attachment to
the provided drain hose located in the tray on
top of the unit. Unwrap the ent ire hose an d
place the open end in a sink, drain, bucket or
outdoors – anywhere tha t water can drai n out
safely. If you use a bucket or other container
for water collection, check it regularly to
prevent overflows.
NOTICE: Uncoil and straighten the entire
drain hose. Do not leave any part of the hose
coiled on the unit and do not plac e the end of
the hose higher than 20 ft. (6 m) above the
bottom of the unit. Also check for kinks or
other obstructions that might restrict the flow
of water. A kink or blockage will cause the unit
to turn off produce an ER9 error code. See
“Error Messages,” below, for more
information.
connect.
number label
Positioning a Dehumidifier
For best results, operate your dehumidifier in an
enclosed area. Close all doors and windows to maximize
the unit’s water removal efficiency. Place your
dehumidifier away from obstructions, and keep it away
from anything that could obstruct airflow into and out of
the unit.
07-02300B F600 2 Dri-Eaz Products, Inc.
Plug in electrical cord
The dehumidifier should be plugged into a
GFCI-protected 115 volt outlet rated for at
least 15
amps. Remove the cord from the
storage tray and uncoil it. Al wa ys plug the
cord firmly into the unit first, and then plug the
other end into a suitable electrical outlet.
Startup display and normal display modes
When unit is first plugged into AC power, the
control panel display will briefl y cycle through
a series of readouts. This is part of the unit’s
self-diagnosis procedure and no user
intervention is required.
Turn the unit on
The control panel has a display and a touchpad with four
keys. Press the ON/OFF to turn the unit on. The unit will
now go through a compressor delay countdown (up to
60 seconds in duration) and a self-diagnostics process,
then switch to normal display mode.
ON/OFF
Press and release to turn unit on
or off.
DISPLAY MENU
Press to select next item in menu.
Menu item will show in display.
MENU SELECTION /
UP KEY
Press to toggle or select values in
menu displayed.
PURGE PUMP
Press and release to start purge.
ON/OFF
DISPLAY
DISPLAY
MENU
PURGE PUMP
CONTROL PANEL
MENU
Display will count down seconds
remaining until purge is complete.
SELECTION /
UP KEY
delay, the display shows UNIT ON XXXX HRS and
cycles between INLET XXX°C and INLET XX%. NOTE:
If no compressor delay countdown is displayed, a delay
is not necessary and the machine will begin operation
immediately.
DISPLAY MENU. Press to cycle through the display of
additional dehumidifier conditions and User Settings. To
return to the main menu, press the ON/OFF key once.
MENU SELECTION. Press to change the values of the
"User Defined" settings. The MENU SELECTION key
acts as the UP key for adjusting the setpoint for
Humidistat mode operation. See User Settings Menu
(next page) for details.
PURGE. Press to empty water from the condensate
pump reservoir. The display will read PUMP PURGING
with a numeral countdown. NOTE: During normal
operation, the pump purges automatically.
NOTE: During normal operation, the pump purges automatically.
UNIT ON XXXX HRS
INLET XXX°C / INLET 00%
The first line of the display shows the total number of
hours the unit has been in operation. This value may be
reset to zero to track job hours (see “Job Hours Reset”
below). The second line of the display alternates
between inlet temperature and in let humidity.
User Settings Menu
A number of settings may be changed by the user.
System information can also be displayed. These items
are accessed by pressing DISPLAY MENU. Each press
of the key will display the next parameter. When you
reach the parameter you wish to adjust, press MENU
SELECTION to increase the value. Press DISPLAY
MENU again to accept the setting and re-start the
display cycle.
Note that only menu items followed by a greater-than
symbol ( > ) may be adjusted.
Error messages
If the onboard diagnostics discover a problem, the unit
will display an error message. See “Error Messages,”
below, for an explanation of each message.
Control Panel Guide
ON/OFF. Press to turn the unit on or off. When the
machine is turned on, the display normally reads
PLEASE WAIT COMP. DELAY and performs a numeral
countdown from a maximum of 60 seconds to 0. This
delay allows time for refrigerant pressures to equalize for
easier starting. Once the unit completes the compressor
07-02300B F600 3 Dri-Eaz Products, Inc.
Press DISPLAY
the next menu item. ↓
□
1. JOB HRS RESET >
PWR INTERRUPT X
1. JOB HR RESET 0
PWR INTERRUPT 0
2. INLET OUTLET
100’ 80% 115’ 30%
3. GRAIN DPR
XX GPP
4. FILTER CLEANED
XXX HRS >
4. FILTER CLEANED
0 HRS
5. COIL CLEANED
XXX HRS >
5. COIL CLEANED
0 HRS
6. HUMIDISTAT
7. HUMIDISTAT
8. IDIOMA
8. SPRACHE
8. LANGUE
9. TEMP UNITS
’F >
9. TEMP UNITS
’C >
10. COIL TEMP
XX’
11. COMP CURRENT
XX.X A
12. FIRMWARE
3.XX FXXX-XXX
13. LIFE HOURS
XXXX HRS
(Returns to
top menu item.)
14. SENSOR ID
(Returns to
top menu item.)
USER SETTINGS
Only menu items followed by a greater-than symbol (>) can be adjusted. If no keys are selected f or 5 minute s on scree ns: INLET
OUTLET, GRAIN DPR (INLET-OUTLET for 230V models), the display will return to normal display mode. In all the other menu items,
the display with return to the normal display mode after 20 seconds. Items without the symbol (>) are for information only and cannot be
changed or reset.
MENU to proceed to
Press ˃ MENU SELECTION to change the setting.
→
MODE OFF >
SETPOINT XX% >
8. LANGUAGE
ENGLISH >
˃
For information only.
Unit displays GPP if set to Fahrenheit or g/kg if set to Celsius. To change this setting, see menu item 9.
˃
˃
˃
˃ Press ˃ to cycle through 40%–90% at 5% increments (default is 50%).
˃
˃
6. HUMIDISTAT
MODE ON >
ESPANOL >
Press ˃ to reset to 0.
Press ˃ to clear filter hours.
Press ˃ to clear coil hours.
Press ˃ to turn ON or OFF. For maximum dehumidification, make sure
HUMIDISTAT is OFF.
˃
DEUTSCH >
Press ˃ to change to °F or °C.
˃
FRANCAIS >
Press ˃ to change
language options.
For information only.
For information only.
For information only.
The following section available only on wireless-equipped units.
XXXXXXXXX
AT THE END OF THE JOB
To reduce the possibility of drips when moving the
unit, follow these additional step s to ensure that all
water is removed from the unit.
NOTICE: The unit will complete the defrost cycle even if
the unit is turned off but still plugged in. If the unit is
unplugged during the defrost c ycle, exc ess ive water may
accumulate in the unit and may drip out when you m ove
the unit.
07-02300B F600 4 Dri-Eaz Products, Inc.
NOTICE: To ensure the condensate tank empties
completely while purging, make sure the unit is placed
upright on a horizontal surface.
1. Do not turn unit off or move it until it has returned
to normal operating mode. To confirm unit status,
review the control panel. The control panel will
display one of the following messages:
Defrost in progress:
---
DEFROST XX
Display mode when unit is in defrost mode. XX indicates
the seconds remaining on the defrost cycle.
Shutdown sequence:
WAIT FOR
DEFROST XX
Display mode when unit in defrost and unit is powered
down (shut off by user). Unit will complete the defrost
cycle to remove any built-up ice then purge the pump.
XX indicates the seconds remaining on the defrost cycle.
Drying sequence:
WAIT FOR
UNIT DRYING XXX
Display mode when unit not in defros t and unit is
powered down (shut off by user). Unit will complete the 5
minute drying cycle then purge the pump. XX indicates
the seconds remaining on the drying cycle.
Normal display:
UNIT ON XXXX HRS
INLET XXX°F / XX%
The unit has completed a defrost and drying cycle and
has returned to normal mode. You may now proceed to
step 2.
• Store and transport securely to avoid an y dam aging
impact to internal parts.
• Secure during transport to prevent sliding and
possible injury to vehicle occupants.
• Do not transport or store the unit on its front, sides or
back. This will help to prevent any remaining moisture
from escaping from the unit or flowing into areas
outside the sump.
MAINTENANCE SCHEDULE
WARNING! ELECTRIC SHOCK HAZARD. Unplug the
dehumidifier before performing any maintenance.
WARNING: Risk of dust and contaminants exposure.
Use of respirator mask and gloves is recommended. If
unit has been exposed to potentially dangerous
contaminants, clean thoroughly and sanitize before
reuse.
NOTICE: The unit is fitted with sensitive electronic
sensors. Protect the sensors and their lead wires from
damage and do not expose them to water or cleaning
solution.
The following tools and supplies are needed to
complete the maintenance procedures described in
this manual:
Philips screwdriver
T-20 Torx bit
10 mm nutdriver or socket and ratchet
Cleaning cloths
HEPA vacuum cleaner with soft brush nozzle and
crevice tool.
2. Gently rock the machine to ensure any water
remaining on interior surfaces falls into the sump
area.
3. Press the PURGE key. When the purge cycle is
complete, turn the unit off.
4. Remove the external drain hose, drain it carefully,
coil it and return it to the storage tray o n th e top of
the unit.
TRANSPORTATION AND STORAGE
IMPORTANT: Before moving, transporting or
storing, purge unit and stow hose and power cord as
described in the “At the End of the Job” section
above.
NOTICE: Handle the unit carefully. Do not drop, throw or
place the unit where it could fall. Rough treatment can
damage the dehumidif ier and may create a hazardous
condition or void the warranty.
07-02300B F600 5 Dri-Eaz Products, Inc.
• Do not expose the control panel to moisture, snow
or rain.
Before each use
Inspect the electrical cord for damage. Look for
fraying, cuts, etc. Replace the cord if you find any
damage.
Inspect filter. Replace if accumulation of dust and
debris is visible.
NOTICE: Replace used filters only with a new Dri-Eaz
filter part no. F579 (24-pack). Other filter types do not
provide adequate filtration or airflo w. Each fi lter is
individually wrapped to prot ect filtr ation effectiveness.
Remove the wrapper before installing the filter into the
dehumidifier.
Monthly
Inspect coils. Clean when dust accumulation is visible.
In normal use, dust can accumulate and can restrict
airflow, reducing performance and causing the unit to
overheat.
To maintain appearance, wipe interior and exterior
surfaces with a damp cloth. For deep cleaning and a
Remove the 4
Fig.
lasting, protective shine, use an automotive interior
treatment product.
B: Disassembly for Cleaning
As Needed
Clean Pump Check Valve and Basin. If the unit
displays the message “ER9 PUMP BLOCKED PUMP
& HOSE”, the pump check valve and pump basin may
need to be cleaned. This requires removal of the front
housing.
Clean coils. Inspect the horizontal evaporator (cold)
coil with the front cover removed. If excessive dust and
debris is present, vacuum thoroughly and/or clean with
alkaline (non-acidic)coil cleaner.
screws from front
housing, and slide
off to access coils
and pump for
service.
07-02300B F600 6 Dri-Eaz Products, Inc.
CONTROL PANEL
FIRMWARE VERSION
XXX
FXXX-XXX
Model number.
None
OFF
Unit has finished powering up and is operat ing.
None
PLEASE WAIT
COMP. DELAY XX
60s delay before compressor turns on. Allows system
pressure to equalize.
First line: indicates total operating hours.
inlet RH every 2 seconds.
First line: indicates unit is in humidistat mode
inlet RH every 2 seconds.
HI TEMP CYCLE
REMAINING XX MIN
---
DEFROST XXXX
Unit turned off when coil is cold or already in a defrost
coils of ice before storage.
WAIT FOR
UNIT DRYING XXX
Occurs when unit is turned off and coil is not frozen.
Clears the coils of water before storage.
CLEAN FILTER >
---
Change filter. Press the > key to
reset
CLEAN COILS >
OFF
Clean coils. Press the > key
to reset
SYSTEM MESSAGES
The Control Panel will display the following messages based on system performance and environmental conditions. User
action, if any is required, is indicated in the third column.
MESSAGE
INITIALIZING Unit is powering up. None
Indicates control board firmware version number. None
UNIT ON XXXX HRS
INLET XXX°F / XX%
HUMIDISTAT
INLET XXX°F / XX%
LOW TEMP
INLET XXX°F / XX%
---
PUMP PURGING XX
Second line: Toggles between inlet temperature and
Second line: Toggles between inlet temperature and
Unit shuts off if inlet temp below 45°F/7°C. Turns back
on when inlet reaches 50°F/10°C.
Displays when the Pump Purge button is pres s ed.
Shows time remaining in seconds.
Unit overload limit reached. Cool-down initiated. None
Unit is defrosting, with countdown in seconds. None
EXPLANATION USER ACTION
None
None
None
None
None
WAIT FOR
DEFROST XXX
cycle. Proceeds to finish cycle or initiate one to clear the
Prompt to change filter.
Prompt to clean coils and interior.
None
None
07-02300B F600 7 Dri-Eaz Products, Inc.
ERROR MESSAGES
If the control system detects an error, it will produce an error (“ER”) message. If this occurs, first unplug the unit and then
plug it back in. This will usually reset the electronics, and the unit will begin operating normally. If the error message
reappears, refer to the explanations and solutions shown below. If these solutions do not fix the problem, contact your
local authorized service center.
CONTROL PANEL
MESSAGE
ER4 DEFROST
SENSOR CONNECT
–or–
ER4 OUTLET
SENSOR CONNECT
ER5 SENSOR
CONNECTION ON BD
ER6 CONTACT
SERVICE CENTER
ER7 INVALID
MODEL SETTING
ER8 BUTTON STUCK
ALL BUTTONS
EXPLANATION AND SOLUTION
Temp sensor is open, missing, or shorted. Check that temp sensors are installed
correctly on control panel. If error persists, contact service.
Inlet Temp/RH sensor is open, missing, or shorted. Check that inlet temp/RH sensor is
installed correctly on control panel and inlet shroud. If error persists, contact service.
Current sensor failure. If error persists, contact service.
Incorrect or unsupported DIP switch settings. Contact Dri-Eaz service department for
correct DIP switch settings.
Key is stuck or has been held down too long. Contact service.
ER9 PUMP BLOCKED
PUMP & HOSE
Check for obstructions. Is the hose kinked under the unit or pinched shut b y a wheel?
Check the pump for blockage and service if needed.
07-02300B F600 8 Dri-Eaz Products, Inc.
Switch unit on.
base of unit.
Make sure “Humidistat” is OFF.
Seal off area to reduce infiltration.
Water removal AHAM
(80°F/60% RH)
Water removal saturation
(90°F/90% RH)
Dimensions
(H × D × W)
32.1 × 19.8 × 20.0 in.
81.5 × 50.3 × 50.8 cm
TROUBLESHOOTING
FAULT CAUSE SOLUTION
Water drips out
when moving unit
Unit does not
operate
Unit operating,
but room not dry
Unit was unplugged before
purging was complete.
Unit not switched on.
No power to machine.
Not enough time to dry.
Poor air movement in room.
Excessive moist air infiltration.
Room air is dry.
Unit collects too
little water
Room temperature is too low.
Filter is full.
Coils are clogged.
If the problem you are experiencing is not listed here, call your local distributor or contact
our Service Department at 800-932-3030 for further assistance.
SPECIFICATIONS
Model LGR 6000Li (F600)
100 pts. | 47.3 L / day
204 pts. | 96.5 L / day
Process air (max.) 330 CFM
Weight 100 lbs. | 45 kg
Amps 6.6A
Volts 115V
Frequency 60Hz
Power 759W
Operating range 33°F–100°F | 1°C–38°C
Noise level (avg.) 60 dB
Drain hose
Power cord
Construction
Safety ETL certified CSA 22.2 no. 92
Specifications are subject to change without notice. Some values
may be approximate.
40 ft. | 12.2 m
25 ft. | 7.6 m
Rotomolded shell
Purge unit before moving. See “At the End of the Job.”
Plug in unit; check power cord connection at wall outlet and at
Allow more time for drying.
Increase air movement with air movers.
Make sure “Humidistat” is OFF.
Confirm humidity level with hygrom et er.
Increase room temperature.
Check filter. Replace as necessary.
Check coils. Clean as necessary.
Order replacement air filters from your local distributor.
Part no. F579 (24 pack). Warranty information is
available at www.dri-eaz.com
.
Be sure to visit warranty.drieaz.com and register your
purchase. Your registration will help us provide you with
updated product information as needed.
For proper disposal, this unit should be taken to a
recycler licensed to process refrigeration equipment.
07-02300B F600 9 Dri-Eaz Products, Inc.
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.