Dri-Eaz LGR1800 Owner's Manual

Owner’s Manual
WARNING
LGR1800 Portable Dehumidifier 230 volt
with remote monitoring capability (F432i)
The Dri-Eaz® LGR1800 dehumidifier reduces humidity in enclosed structural environments by removing water vapour from the air. The LGR1800 is engineered for improved operating performance within lower humidity environments. With a rugged, durable and highly port­able design, the LGR1800 is ideally suited for water damage restoration, structural drying, construction, and other applications requiring temporary, high-performance dehumidification. With built-in humidistat control, the LGR1800 is ideal for environments that require longer term humidity control, museums, server rooms, etc.
READ AND SAVE THESE INSTRUCTIONS
SAFETY INSTRUCTIONS
WARNING! Electric shock hazard, rotating fan, hot surface hazards. Unplug unit before opening cover for cleaning or servicing. Unit must be earthed.
Inspect the power cord before use. If cord is damaged, do not use. Always grasp the plug (not the cord) to unplug.
The unit must be operated on a 230V/50Hz circuit protected by a Residual Current Device (RCD).
Keep motor and wiring dry.
Do not operate in standing water
Do not operate in rain or snow. If electrical
components become wet, allow them to dry before using.
Do not attempt to repair the unit. For service, call Dri–Eaz at +44 (0)1908-611-211
BEFORE YOU BEGIN
Unpacking your unit
Retain all packing material and boxes for possibl e equipment returns.
Warranty registration
Complete and post the enclosed card to register your purchase. Registration allows us to better as sist you with using, maintaining and servicing your equipment, and provides us with your contact information in cas e we
need to communicate important safety information concerning your Dri-Eaz product. If you determi ne service is required, have your equipment m odel, serial number and original proof of purchase available and call Dri-Eaz on +44 (0)1908-611-211 for assistance.
INTRODUCTION
Dehumidifiers reduce humidity in enclos ed st ructural environments by removing water vapour from the air. With proper use, the LGR1800 can help dry carpet , carpet pad, floors, walls, building contents and mo re. Using dehumidifiers can also help prevent secondary damage caused by high humidity. For best result s, use the LGR1800 with Dri-Eaz TurboDryer airmover s placed around the perimeter of the room. Airmovers help to distribute heat energy, which accelerate the release of moisture from wet surfaces into the air.
How the LGR1800 dehumidifier works
Dri-Eaz refrigerant dehumidifiers operat e by pulling moist air in across a very cold evaporator coil. The moisture in the air condenses on the coil and drips i nto a catch basin. The water collects in a tray and is pumped out through a hose. In certain conditions, the machine operates in defrost mode, warming any frost accumulated on the evaporator coil back into water. LGR (Low Grain Refrigerant) dehumidifiers have better heat exchange and defrost abilities than regular refrigerant dehumidifiers, and are able to continue removi ng moisture in drier environments.
Remote Monitoring Option
Your Dri-Eaz distributor can modify the LGR1800 to work with the HygroTrac Remote Monitoring System (purchased separately). HygroTrac lets you view dry ing environment conditions and equipment performance from any Web browser. Contact Dri-Eaz on +44 (0)1908­611-211 for more information about this option.
07-01706B 2010-02 1 Dri-Eaz Products
POSITIONING A DEHUMIDIFIER
FIG. B: SECURING HANDLE
FIG. C: HOSE STORAGE
FIG. A: BACK
For best results, operate your dehumidifiers in an enclosed area, as this creates a drying chambe r. Close all doors and windows that open to the outside to maximise the unit’s water removal efficiency. Also, keep traffic though the drying chamber to a minimum. Place your LGR1800 dehumidifier against a wall, away from obstructions, and keep it away from anyt hi ng that could block airflow into and out of the unit.
IMPORTANT: Before moving the unit, make sure there’s no water in the pump. See how to use the PURGE function under “How to Use the Control Panel” on page
3.
Managing temperatur e rise
Controling temperature in the drying environment is critical. The most accurate way to monitor temperature i s
PARTS IDENTIFICATION
with a thermo-hygrometer; however, you can use an indoor/outdoor thermometer to gauge tem perature. For improved accuracy, take temperature readings in in the center of the room, away from the airflow of the dehumidifier.
Dri-Eaz dehumidifiers warm the air as they remov e moisture. Optimal drying temperatures range from 20– 29°C (68–85°F). This may require the use of the building’s HVAC (heating and air conditioning) system. If heating and cooling is not available at the site, contact Dri-Eaz and a Technical Specialist will help you find an appropriate solution.
For more information about creating an optim um dry i ng environment, contact Dri-Eaz on +44 (0)1908-611-211.
Handle (in stored position).
Hose storage tabs. Rotate upper tab to release hose.
Location of pump and catch basin.
1. Rotate locking lever to right to release handle.
2. Raise handle to upright position and secure in place with locking lever.
3. Reverse procedure to secure handle for shipping and storage.
Rotate hose storage tab 180 degrees to the right to release drain hose.
07-01706B 2010-02 2 Dri-Eaz Products
ON/OFF
DISPLAY
Control panel
FIG. D: FRONT
OPERATING YOUR DEHUMIDIFIER
let the unit rest for five minutes before restarting. Otherwise it might shut off again.
Set unit upright
Always operate the dehumidifier in an upright position. If the unit has been stored or transported in a horizontal position, set it upright (in a vertical position) for at least 30 minutes before operating it. This will allow for any compressor oil that has flowed into the refrigerant coils to return to the compressor and allow the dehumidifie r to function properly.
Moulded cord storage.
Process (dehumidified) air outlet. May be used with standard 300 mm (12 in.) rigid or layflat ducting.
Air filter access door. Lift handle to release.
Humid air inlet (both sides).
Set up drain hose
The LGR1800 pump connects to a plastic drainage hose. The hose can be stored on the hose wrap, lo cated on the back of the unit (see Fig. A). You can release the hose by rotating the top reel of the hose wrap down; simply pull outward until you’re able to rotate it (see Fig. C). Rotate the tab to the right or left until it is pointing straight down. This feature makes it easy to take off the entire hose quickly. Place the unattached hose end in a sink, drain, bucket –even outside; anywhere that water can drain out safely.
NOTE: Uncoil and straighten the entire drain h ose. Do not leave any of part of the hose coiled on the unit and do not place the end of the hose higher than 4.5 m (15 ft.) above the top of the unit. Also check for kinks, or obstructions that would restrict the flow of water. Failure to do so may cause a water backup in the pump resulting in leakage.
Plug in electrical cord
The electrical cord is wrapped around the top of t he uni t. The LGR1800 will operate on any standard 230-volt Residual Current Device (RCD) protected outlet.
If the unit experiences a loss of power, either from a power interruption or from thermal overload pr otection,
Turn the unit on
The control panel on the LGR1800 has a display and a touchpad with four keys. Press the the unit on.
CONTROL PANEL
DISPLAY MENU
ON/OFF to turn
PURGE PUMP
MENU SELECTION / UP KEY
How to use the control panel
The control panel on the LGR1800 has a display and a touchpad with four keys.
ON/OFF. Press the ON/OFF key to turn the uni t on or off. When the machine turns on, the display normal l y reads PLEASE WAIT COMP. DELAY and performs a numeral count down from a maximum of 60 seconds to 0. This delay allows time for refrigerant pressures to equalise for easier starting. If you don’t see a compressor delay countdown, a delay is not neces sary and the machine will begin operation immediately . Once the unit completes the compressor delay, the display shows UNIT ON XX HRS and cycles between INLET TEMP XX°C and INLET RH XX%.
DISPLAY MENU. Press the DISPLAY MENU key to cycle through the display of additional dehumidi fier conditions and User Settings. To return t o the main menu, press the ON/OFF button once.
MENU SELECTION. Press the MENU SELECTION key to change the values on the "User Defined" set tings. The MENU SELECTON key acts as the UP key for adjusting the setpoint for Humidistat mode operation. See User Settings Menu (below) for details.
PURGE. Press the PURGE key to manually em pty water from the condensate pump reservoir. NOTICE: Always press the purge key prior to moving the uni t. During normal operation, the pump purges autom atically every six minutes, or whenever the reservoir is full. The
07-01706B 2010-02 3 Dri-Eaz Products