Dri-Eaz HydroSensor I, HydroSensor II Owner's Manual

Owner’s Manual
HydroSensor I & II Moisture Probes
Models F245, F251
DRI-EAZ PRODUCTS, INC.
15180 Josh Wilson Road, Burlington, WA 98233
Phone: 800-932-3030 Fax: 360-757-7950 http://LegendBrandsRestoration.com
Patents: http://www.LBpatents.com
REA D A N D S A V E T H E S E I N S T R U C T I O N S
NOTICE: The sensor points of the HydroSensor probe are extremely sharp. Take care when collapsing the telescoping tubes to avoid the points extending by accident. This could cause injury. Always retract the probe points into the shaft when not in use.
BEFORE YOU BEGIN
Warranty registration
Visit warranty.LegendBrandsRestoration.com to register your purchase. Registration allows us to better assist you with us­ing, maintaining or servicing your equipment and to contact you in case we have important safety information concerning your Dri-Eaz product. If you determine service is required, have your equipment model, serial number and original proof of purchase available and call your distributor for assistance with obtaining a return material authorization (RMA).
OPERATION
1. When using the HydroSensor II, first extend the shaft. Grasp the smaller-diameter tube and slide it out until the spring button pops into place.
2. Extend the sensor points at the bottom of the probe. Loosen the black plastic knob. Push it down and around the S­shaped slot, then tighten the knob to lock in position.
3. Test the unit by placing your fingers across the shaft of the points. The indicator lamp will light and the unit will beep.
4. Probe the suspected moisture area with the points. Flash­ing and beeping indicates that carpet and/or pad are wet. A faster rate of beeping/flashing indicates a higher level of moisture.
5. Take care not to apply too much force on the probe. Excess force may damage the tips or telescoping tubes.
6. Always retract the sensor points when not in use.
INTRODUCTION
The HydroSensor Moisture Probes I & II are designed to detect moisture in carpets, cushion, floors, walls, furniture and other materials. When the probe tips are pushed into materials to penetrate the surface, an electric current is sent between the probes. The amount of moisture present in the material deter­mines how easily the electrical current passes from one probe to the other.
When moisture is present in a material, the light on the Hy­droSensor will flash and the transducer will beep. The faster the rate of flashing and beeping, the higher the level of mois­ture.
The 7/8” probe tips are long enough to penetrate shag carpets,
cushion, and flooring materials. With care, the HydroSensor can also be used to find moisture in furniture, walls, and ceiling materials.
The HydroSensor will also detect the presence of urine resi­dues. This is because urine salts attract and hold enough moisture to be detected. A black-light is recommended to con­firm that urine is present.
07-00315E F245, F251 1 Dri-Eaz Products, Inc.
Dimensions
HydroSensor I: 31 in. HydroSensor II: 31 in. extended; 21 in. col-
lapsed
Probe tips
7/8 in. nickel plated steel
Shaft
Stainless steel
Handle
Injection molded
Indicator light
LED in handle
Weight
1 lb.
Power
One 9-volt DC battery (included)
MAINTENANCE
After each use
Clean and dry the unit with a soft cloth.
As needed
If the probe tips become dull, they may be resharpened with a file. If points need replacement because of excessive wear, con­tact Dri-Eaz for a replacement kit.
Battery Replacement The HydroSensor is operates on the current from one 9-volt battery.
Battery life depends on usage and storage conditions. Do not allow probe tips to stay in contact with metal, damp cloth, car­pet, water, cork or any other materials that will conduct electric­ity.
If the indicator light no longer illuminates, it may be time to re­place the batters. The battery is contained inside the handle below the indicator light. To inspect and replace the battery, follow these instructions:
1. Remove the small screws that hold the handle halves to­gether, and gently split apart the handle.
2. Remove the old battery from its connectors and replace with a new general-purpose 9-volt battery.
3. Reinsert battery into handle.
4. Align the holes of the handle halves and replace the screws. Take care not to pinch any wires. Do not overtighten.
SPECIFICATIONS
ADDITIONAL PRODUCT INFORMATION and current
documentation is available at LegendBrandsRestora­tion.com.
FOR PARTS AND SERVICE CALL YOUR LOCAL DIS­TRIBUTOR or Dri-Eaz at 800-932-3030.