Drieaz F571-230V, F571-110V Owner's Manual

Owner’s Manual
WARNING
Cube Dehumidifier
Models F571-230V & F571-110V EU/UK
LEGEND BRANDS EUROPE HOLDINGS LTD.
22 Plover Close, Interchange Park, Newport Pagnell, MK16 9PS
Tel: +44 (0)1908-611-211 Fax: +44 (0)1908-611-363 www.legendbrandseurope.com
The Dri-Eaz® Cube Dehumidifier reduces humidity in enclosed environments by removing water vapor from the air. The Cube is ideal for water damage restoration, structural drying, construction, and many other applications requiring temporary, high-performance dehumidification.
Patents: http://www.LBpatents.com
ORIGI N A L I N S T R UC T I O N S
WARNING! Electric shock hazard, rotating fan hazard and hot surface hazards.
Inspect the power cord before use. If cord is
damaged, do not use. Always grasp the plug (not the cord) to unplug.
Must be earthed. Insert three-prong plug on power
cord into a matching electrically earthed outlet. Do not use adapter. Never cut off third prong. Do not use an extension cord.
The unit must be operated on a 230V or 110V 50 Hz
circuit protected by a Residual Current Device (RCD) device, depending on model.
Keep motor and wiring dry. Always unplug unit before cleaning or servicing. Do not attempt to repair the unit. For service,
contact your local distributor.
FIRE HAZARD
Keep away from open flames and heat sources. Do not use or store where vapors from gasoline,
solvents, thinners or other flammable materials may be present.
BEFORE YOU BEGIN
Warranty registration
Warranty registration procedures vary by country/market. Contact your local distributor for assistance. Registration allows us to better assist you with using, maintaining and servicing your equipment and to contact you in case we have important safety
information concerning your Dri-Eaz product. If you determine service is required, have your equipment model, serial number and original proof of purchase available and ask for assistance with obtaining a return material authorization (RMA).
GROUNDING INSTRUCTIONS
This unit’s plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING! Improper connection of the equipment­grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlets are properly grounded. Do not modify the plugs provided with the appliance – if the plugs do not fit the outlets, have proper outlets installed by a qualified electrician.
This equipment is for use on circuits with a nominal rating of no more than 230V.
Handle the unit carefully
Always operate the unit on a stable, level surface. Do not drop, throw, or place where it could fall. Rough treatment can damage the unit, and may create a hazardous condition or void the warranty.
This unit intended for household and commercial use.
CONTROLS AND OPERATING INSTRUCTIONS
Set unit upright
NOTICE: Always store, transport, and use the unit in a horizontal position. If the unit is ever placed in a vertical position, return it to the horizontal position and let it stand for at least 30 minutes before turning it on.
Positioning a Dehumidifier
For best results, operate your dehumidifiers in an enclosed area. Close all doors and windows that open to the outside to maximize water removal efficiency. Place
07-02282A F571-230V & F571-110V 1 Legend Brands Europe Holdings Ltd.
your dehumidifier away from obstructions, and keep it
ON/OFF
Press and release to turn unit on or off.
DISPLAY MENU
Press to select next item in menu. Menu item will show in display.
MENU SELECTION / UP KEY
Press to toggle or select values in menu displayed.
PURGE PUMP
Press and release to start purge. Display will count down seconds remaining until purge is complete.
Carry handles
Fig. A: Parts Identification
Air inlet
Control Air outlet
(both sides)
Cord and Air outlet
(both sides)
Remove/Insert
CONTROL PANEL
ON/OFF
DISPLAY MENU
MENU SELECTION / UP KEY
PURGE PUMP
away from anything that could block airflow into and out of the unit. For more information about creating an optimum drying environment, contact your local distributor.
Set up drain hose
Unwrap the entire hose and place the unattached end in a sink, drain, bucket or outdoors – anywhere that water can drain out safely. If you use a bucket or other container for water collection, check it regularly to prevent overflows. Verify hose fitting is attached to short hose exiting the unit.
NOTICE: Uncoil and straighten the entire drain hose. Do not leave any part of the hose coiled and do not place the end of the hose higher than 6 m above the bottom of the unit. Also check for kinks or other obstructions that might restrict the flow of water. Obstructions may cause a water backup and result in overflows.
air filter here.
panel
hose storage compartment.
Turn the unit on
The control panel has a display and a touchpad with four keys. Press the ON/OFF to turn the unit on. The unit will now go through a compressor delay countdown (up to sixty seconds in duration) and an automatic diagnostics process.
Once the compressor delay countdown and self­diagnostics are complete, the display will switch to
normal display mode.
UNIT ON 00 HRS
INLET 00°C / INLET 00%
The first line of the display shows the total number of hours the unit has been in operation. This value may be
reset to zero to track job hours (see “Job Hours Reset”
below). The second line of the display alternates between inlet temperature and inlet humidity.
Plug in electrical cord
The unit should be plugged into a 230V/50Hz or 110V/50Hz outlet depending on the model.
Startup display and normal display modes
When unit is first plugged in to AC power, the control panel display will briefly cycle through a series of readouts. This is part of the unit’s self-diagnosis procedure and no user intervention is required.
07-02282A F571-230V & F571-110V 2 Legend Brands Europe Holdings Ltd.
User Settings Menu
A number of display settings may be changed by the user. System information can also be displayed. These items are accessed by pressing DISPLAY MENU. Each press of the key will display the next parameter. When you reach the parameter you wish to adjust, press
MENU SELECTION to increase the value. Press DISPLAY MENU again to accept the setting and re-start the display cycle.
Note that only menu items followed by a greater-than symbol ( > ) may be adjusted.
All settings and modes are discussed in detail in Control Panel Guide.
To return to the main menu, press the ON/OFF key once.
Error messages
If the onboard diagnostics discover a problem, the unit
will display an error message. See “Error Messages,”
p. 7 for an explanation of each message.
Control Panel Guide
ON/OFF. Press to turn the unit on or off. When the
machine is turned on, the display normally reads PLEASE WAIT COMP. DELAY and performs a numeral countdown for a maximum of 60 seconds to 0. This delay allows time for refrigerant pressures to equalize for easier starting. Once the unit completes the compressor delay, the display shows UNIT ON XX HRS and cycles between INLET XX°F and INLET XX%. NOTE: If no compressor delay countdown is displayed, a delay is not necessary and the machine will begin operation immediately.
DISPLAY MENU. Press to cycle through the display
of additional dehumidifier conditions and User Settings.
MENU SELECTION. Press to change the values of
the "User Defined" settings. The MENU SELECTION key acts as the UP key for adjusting the setpoint for Humidistat mode operation. See User Settings Menu (below) for details.
PURGE. Press to empty water from the condensate
pump reservoir. The display will read PUMP PURGING with a numeral countdown. NOTE: During normal operation, the pump purges automatically.
Changing settings and viewing system information
Display setting changes and system information can be accessed by pressing DISPLAY MENU. Each press of the key will display the next parameter (see list below). When you reach the parameter you wish to adjust, press MENU SELECTION to increase the value. Press DISPLAY MENU again to accept the setting and re-start the display cycle
Note that only menu items followed by a greater-than symbol ( > ) may be adjusted.
07-02282A F571-230V & F571-110V 3 Legend Brands Europe Holdings Ltd.
Loading...
+ 5 hidden pages