Dri-Eaz F533-115V Operation And Maintenance Manual

Operation and Maintenance Guide
DriTec™ 4000i Desiccant Dehumidifier
Model F533-115V
DRI-EAZ PRODUCTS, INC.
15180 Josh Wilson Road, Burlington, WA 98233
This document is a supplement to the DriTec 4000i Owner’s Manual supplied with the unit.
Please refer to the Owner’s Manual for important safety information.
Patents: http://www.LBpatents.com
READ AND SAVE THESE INSTRUCTIONS
GROUNDING INSTRUCTIONS
This unit’s plugs must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING! Improper connection of the equipme n t-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlets are properly grounded. Do not modify the plugs provided with the appliance – if the plugs do not fit the outlets, have proper outlets installed by a qualified electrician.
This equipment is for use on circuits with a nominal rating of no more than 120V.
Handle the unit carefully
Always operate the unit on a stable, level surface. Do not drop, throw, or place where it could fall. Rough treatment can damage the unit, and may create a hazardous condition or void the warranty.
This unit intended for household and commercial use.
BEFORE FIRST USE
TOOLS REQUIRED
3mm Allen wrench and/or bits and cordless drill
The unit is shipped with two duct rings and an adaptor kit, two power cords, and the Owner’s Manual packed inside the storage compartment.
F533-115V 1 Dri-Eaz Products, Inc.
Parts Identification
Air filter
Power sockets inside
Air inlet
Reactivation
Control panel
Process Air Out-
compartment. Stor­age for power cords,
Air Outlet (installation of duct re­quired)
react ducting.
let (optional duct attachment kit provided)
Required: Install Reactivation Air Outlet duct ring. Note: The
unit must always be operated with the react duct ring and ducting provided.
Insert duct ring into circular slot and rotate clockwise until snug.
F533-115V 2 Dri-Eaz Products, Inc.
Optional: Install Process Outlet Duct Ring
Install the 4 offset screws provided. Note the correct placement of the washer and spacer on the screw. Do not overtighten.
Optional: Install Air Inlet Duct Ring
Attach to inlet with the thumbscrews prov ided.
F533-115V 3 Dri-Eaz Products, Inc.
SETUP AND OPERATIONS
NOTICE
Positioning the Dehumidifier
For best results, operate your dehumidifier in an en­closed area. Close all doors and windows that open to the outside to maximize water removal efficiency. Place your dehumidifier away from any obstructions that could block airflow into and out of the unit. Duct reactivation outlet outdoors through window adapter or dryer vent.
Plug in electrical cords
Always plug the cords firmly into the sockets in the top compartment first, then into the wall out­lets. Ensure that the cords are route d properly through the cord cutout notch before closing the storage compartment lid.
NOTICE: The power cords of the DriTec must be
plugged into separate GFCI-protected 120V outlets rated for at least 15A.
NOTICE: Connect to two separate 15A circuits ON­LY. A bright green light on the front of the unit indi­cates correct connect ions . No ligh t will sho w whe n using only one cord or if both power cords are plugged into the same power circuit.
If a second circuit is not available, the unit may be operated on a single power cord. Plug into Circuit 1. Note that the unit will operate at 50% of the rated performance when using a single pow­er cord.
Condensation may collect in the reactivation duct during opera­tion. Do not allow water to run back into the unit. This could cause a shock hazard or damage to the unit.
Startup display and normal display modes
When unit is first plugged in, the control panel dis­play will briefly cycle through a series of readouts. This is part of the unit’s self-diagnosis procedure and no user intervention is required.
F533-115V 4 Dri-Eaz Products, Inc.
Ducting Setup
For ducting configurations, see “Ducting Options,” p. 5.
Reactivation Outlet Ducting
The reactivation air should always be ducted to the outside. Reactivation outlet ducting should not exceed 20 ft. (6 m) in length. Do not operate unit without reactivation outlet ducting in place.
NOTICE: Temperatures inside React Out ducting can reach 150°F (66°C). Use only heat-rated ducting as provided.
React ducting should always be ducted out-of­doors.
Process Outlet Ducting (Optional)
The process out air may be ducted where more fo­cused drying is required. Use with layflat ducting only.
Process outlet ducting should not exceed10 ft. (3 m) in length.
1. Insert the layflat ducting through the process outlet duct bracket and fold over as shown in photo to the right.
F533-115V 5 Dri-Eaz Products, Inc.