Operation and Maintenance Guide
DriTec™ 4000i Desiccant Dehumidifier
Model F533-115V
DRI-EAZ PRODUCTS, INC.
15180 Josh Wilson Road, Burlington, WA 98233
Phone: 800-932-3030 Fax: 360-757-7950 http://DriTec.DriEaz.com
This document is a supplement to the DriTec 4000i Owner’s Manual supplied with the unit.
Please refer to the Owner’s Manual for important safety information.
Patents: http://www.LBpatents.com
READ AND SAVE THESE INSTRUCTIONS
GROUNDING INSTRUCTIONS
This unit’s plugs must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all
local codes and ordinances.
WARNING! Improper connection of the equipme n t-grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service person if you are in doubt as to whether the outlets are properly
grounded. Do not modify the plugs provided with the appliance – if the plugs do not fit the outlets, have proper
outlets installed by a qualified electrician.
This equipment is for use on circuits with a nominal rating of no more than 120V.
Handle the unit carefully
Always operate the unit on a stable, level surface. Do not drop, throw, or place where it could fall. Rough treatment can
damage the unit, and may create a hazardous condition or void the warranty.
This unit intended for household and commercial use.
BEFORE FIRST USE
TOOLS REQUIRED
• 3mm Allen wrench and/or bits and cordless drill
The unit is shipped with two duct rings and an adaptor
kit, two power cords, and the Owner’s Manual packed
inside the storage compartment.
F533-115V 1 Dri-Eaz Products, Inc.

compartment. Storage for power cords,
Air Outlet
(installation
of duct required)
react ducting.
let (optional duct
attachment kit
provided)
Required:
Install Reactivation Air Outlet duct ring. Note: The
unit must always be operated with the react duct ring
and ducting provided.
Insert duct ring into circular slot and rotate clockwise
until snug.
F533-115V 2 Dri-Eaz Products, Inc.

Optional:
Install Process Outlet Duct Ring
Install the 4 offset screws provided. Note the correct
placement of the washer and spacer on the screw. Do
not overtighten.
Optional:
Install Air Inlet Duct Ring
Attach to inlet with the thumbscrews prov ided.
F533-115V 3 Dri-Eaz Products, Inc.

SETUP AND OPERATIONS
Positioning the Dehumidifier
For best results, operate your dehumidifier in an enclosed area. Close all doors and windows that open
to the outside to maximize water removal efficiency.
Place your dehumidifier away from any obstructions
that could block airflow into and out of the unit. Duct
reactivation outlet outdoors through window adapter
or dryer vent.
Plug in electrical cords
Always plug the cords firmly into the sockets in
the top compartment first, then into the wall outlets. Ensure that the cords are route d properly
through the cord cutout notch before closing the
storage compartment lid.
NOTICE: The power cords of the DriTec must be
plugged into separate GFCI-protected 120V outlets
rated for at least 15A.
NOTICE: Connect to two separate 15A circuits ONLY. A bright green light on the front of the unit indicates correct connect ions . No ligh t will sho w whe n
using only one cord or if both power cords are
plugged into the same power circuit.
If a second circuit is not available, the unit may
be operated on a single power cord. Plug into
Circuit 1. Note that the unit will operate at 50% of
the rated performance when using a single power cord.
Condensation may collect in the reactivation duct during operation. Do not allow water to run back into the unit. This could
cause a shock hazard or damage to the unit.
Startup display and normal display modes
When unit is first plugged in, the control panel display will briefly cycle through a series of readouts.
This is part of the unit’s self-diagnosis procedure and
no user intervention is required.
F533-115V 4 Dri-Eaz Products, Inc.

Ducting Setup
For ducting configurations, see “Ducting Options,” p. 5.
Reactivation Outlet Ducting
The reactivation air should always be ducted to the
outside.
Reactivation outlet ducting should not exceed 20 ft.
(6 m) in length. Do not operate unit without reactivation
outlet ducting in place.
NOTICE: Temperatures inside React Out ducting
can reach 150°F (66°C). Use only heat-rated ducting
as provided.
React ducting should always be ducted out-ofdoors.
Process Outlet Ducting (Optional)
The process out air may be ducted where more focused drying is required. Use with layflat ducting only.
Process outlet ducting should not exceed10 ft. (3 m) in
length.
1. Insert the layflat ducting through the process outlet
duct bracket and fold over as shown in photo to the
right.