Dri-Eaz F413-230V UK, F413-230V EU Owner's Manual

6
WARNING
Owner’s Manual
Revolution LGR Dehumidifier
Model F413-230V EU/UK
LEGEND BRANDS HOLDINGS LTD.
22 Plover Close, Interchange Park, Newport Pagnell, MK16 9PS
Tel: +44 (0)1908-611-211 Fax: +44 (0)1908-611-363 www.legendbrandseurope.com
The Dri-Eaz® Revolution LGR Dehumidifier reduces humidity in enclosed environments by removing wa­ter vapor from the air. The Revolution is ideal for water damage restoration, structural drying, construc­tion, and many other applications requiring temporary, high-performance dehumidification.
Patents: http://www.LBpatents.com
ORIGINAL INSTRUCTIONS
WARNING! Do not alter or modify your dehumidifier in any way. Use only replacement parts authorized by Dri-Eaz Products, Inc. Modifications or use of unapproved parts could create a hazard and will void your warranty. Contact your authorized distributor for assistance.
WARNING! Electric shock hazard, rotating fan haz­ard and hot surface hazards.
Inspect the power cord before use. If cord is dam­aged, do not use. Always grasp the plug (not the cord) to unplug.
Must be earthed. Insert three-prong plug on power cord into a matching electrically earthed outlet. Do not use adapter. Never cut off third prong. Do not use an extension cord.
The unit must be operated on a 230V/50 Hz circuit protected by a Residual Current Device (RCD) de­vice.
Keep motor and wiring dry.
Always unplug unit before cleaning or servicing.
Do not attempt to repair the unit. For service, contact
your local distributor.
FIRE HAZARD
Keep away from open flames and heat sources.
Do not use or store where vapors from gasoline, sol-
vents, thinners or other flammable materials may be present.
BEFORE YOU BEGIN
Warranty registration
Warranty registration procedures vary by country/mar­ket. Contact your local distributor for assistance. Regis­tration allows us to better assist you with using, main­taining or servicing your equipment and to contact you in case we have important safety information concerning your Dri-Eaz product. If you determine service is re­quired, have your equipment model, serial number and original proof of purchase available and ask for assis­tance with obtaining a return material authorization (RMA).
GROUNDING INSTRUCTIONS
This unit’s plug must be inserted into an appropriate out­let that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING! Improper connection of the equipment­grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlets are properly grounded. Do not modify the plugs pro­vided with the appliance – if the plugs do not fit the outlets, have proper outlets installed by a qualified electrician.
This equipment is for use on circuits with a nominal rat­ing of no more than 230V.
Handle the unit carefully
Always operate the unit on a stable, level surface. Do not drop, throw, or place where it could fall. Rough treat­ment can damage the unit, and may create a hazardous condition or void the warranty.
This unit intended for household and commercial use.
07-01899G F413-230V EU/UK 1 Legend Brands Holdings Ltd.
CONTROLS AND OPERATING INSTRUCTIONS
Set unit upright
NOTICE: Always store, transport, and use the unit in a horizontal position. If the unit is ever placed in a vertical position, return it to the horizontal position and let it stand for at least 30 minutes before turning it on.
Positioning a Dehumidifier
For best results, operate your dehumidifiers in an en­closed area. Close all doors and windows that open to the outside to maximize water removal efficiency. Place your dehumidifier away from obstructions, and keep it away from anything that could block airflow into and out of the unit. For more information about creating an opti­mum drying environment, contact your local distributor.
Set up drain hose
This unit automatically pumps out water on a regular ba­sis. This dehumidifier is equipped with a quick-connect fitting for quick attachment to the provided 12 m drain hose. Unwrap the entire hose and place the open end in a sink, drain, bucket or outdoors – anywhere that water can drain out safely. If you use a bucket or other con­tainer for water collection, check it regularly to prevent overflows.
NOTICE: Uncoil and straighten the entire drain hose. Do not leave any part of the hose coiled and do not place the end of the hose higher than 6 m above the bottom of the unit. Also check for kinks or other obstructions that might restrict the flow of water. Obstructions may cause a water backup and result in overflows.
Fig. A: Parts Identification
Carry handles
Control panel
Air inlet
Cord and hose storage wraps.
Condensate drain quick­connect
UNIT ON XXXX HRS
INLET XXX°C / INLET 00%
The first line of the display shows the total number of hours the unit has been in operation. This value may be reset to zero to track job hours (see “Job Hours Reset” below). The second line of the display alternates be­tween inlet temperature and inlet humidity.
Air outlet
Temp/RH sensor
Remove/Insert air filter here.
Plug in electrical cord
The unit should be plugged into a 230V/50Hz outlet.
Startup display and normal display modes
When unit is first plugged in to AC power, the control panel display will briefly cycle through a series of readouts. This is part of the unit’s self-diagnosis proce­dure and no user intervention is required.
Turn the unit on
The control panel has a display and a touchpad with four keys. Press the will now go through a compressor delay countdown (up to sixty seconds in duration) and a self diagnostics pro­cess.
Once the compressor delay countdown and self-diag­nostics are complete, the display will switch to normal display mode.
07-01899G F413-230V EU/UK 2 Legend Brands Holdings Ltd.
ON/OFF to turn the unit on. The unit
User Settings Menu
ON/OFF
Press and release to turn unit
or off.
DISPLAY MENU
Press to select next item in
display.
MENU SELECTION / UP KEY
Press to toggle or select values in menu displayed.
PURGE PUMP
Press and release to start purge.
A number of display settings may be changed by the user. System information can also be displayed. These items are accessed by pressing
DISPLAY MENU. Each press of the key will display the next parameter. When you reach the parameter you wish to adjust, press
MENU SELECTION to increase the value. Press DISPLAY MENU again to accept the setting and re-start the display cycle.
Note that only menu items followed by a greater-than symbol ( > ) may be adjusted.
All settings and modes are discussed in detail in Control Panel Guide.
CONTROL PANEL
DISPLAY
ON/OFF
DISPLAY MENU
on
menu. Menu item will show in
Display will count down sec­onds remaining until purge is complete.
PURGE PUMP
MENU SELECTION / UP KEY
Error messages
If the onboard diagnostics discover a problem, the unit will display an error message. See “Error Messages,” below, for an explanation of each message.
Control Panel Guide
ON/OFF. Press to turn the unit on or off. When the ma-
chine is turned on, the display normally reads PLEASE WAIT COMP. DELAY and performs a numeral count­down for a maximum of 60 seconds to 0. This delay al­lows time for refrigerant pressures to equalize for easier starting. Once the unit completes the compressor delay, the display shows UNIT ON XX HRS and cycles be­tween INLET XX°F and INLET XX%. NOTE: If no com­pressor delay countdown is displayed, a delay is not necessary and the machine will begin operation immedi­ately.
DISPLAY MENU. Press to cycle through the display of additional dehumidifier conditions and User Settings. To return to the main menu, press the ON/OFF key once.
MENU SELECTION. Press to change the values of the "User Defined" settings. The MENU SELECTION key acts as the UP key for adjusting the setpoint for Humidi­stat mode operation. See User Settings Menu (below) for details.
PURGE. Press to empty water from the condensate pump reservoir. The display will read PUMP PURGING with a numeral countdown. NOTE: During normal operation, the pump purges auto­matically.
Changing settings and viewing system information
Display setting changes and system information can be accessed by pressing of the key will display the next parameter (see list be­low). When you reach the parameter you wish to adjust, press Press
MENU SELECTION to increase the value.
DISPLAY MENU again to accept the setting
and re-start the display cycle
Note that only menu items followed by a greater-than symbol ( > ) may be adjusted.
DISPLAY MENU. Each press
07-01899G F413-230V EU/UK 3 Legend Brands Holdings Ltd.
Loading...
+ 6 hidden pages