6
Owner’s Manual
Revolution LGR Dehumidifier
Model F413-230V EU/UK
LEGEND BRANDS HOLDINGS LTD.
22 Plover Close, Interchange Park, Newport Pagnell, MK16 9PS
Tel: +44 (0)1908-611-211 Fax: +44 (0)1908-611-363 www.legendbrandseurope.com
The Dri-Eaz® Revolution LGR Dehumidifier reduces humidity in enclosed environments by removing water vapor from the air. The Revolution is ideal for water damage restoration, structural drying, construction, and many other applications requiring temporary, high-performance dehumidification.
Patents: http://www.LBpatents.com
ORIGINAL INSTRUCTIONS
WARNING! Do not alter or modify your dehumidifier
in any way. Use only replacement parts authorized
by Dri-Eaz Products, Inc. Modifications or use of
unapproved parts could create a hazard and will
void your warranty. Contact your authorized
distributor for assistance.
WARNING! Electric shock hazard, rotating fan hazard and hot surface hazards.
• Inspect the power cord before use. If cord is damaged, do not use. Always grasp the plug (not the
cord) to unplug.
• Must be earthed. Insert three-prong plug on power
cord into a matching electrically earthed outlet. Do
not use adapter. Never cut off third prong. Do not
use an extension cord.
• The unit must be operated on a 230V/50 Hz circuit
protected by a Residual Current Device (RCD) device.
• Keep motor and wiring dry.
• Always unplug unit before cleaning or servicing.
• Do not attempt to repair the unit. For service, contact
your local distributor.
FIRE HAZARD
• Keep away from open flames and heat sources.
• Do not use or store where vapors from gasoline, sol-
vents, thinners or other flammable materials may be
present.
BEFORE YOU BEGIN
Warranty registration
Warranty registration procedures vary by country/market. Contact your local distributor for assistance. Registration allows us to better assist you with using, maintaining or servicing your equipment and to contact you in
case we have important safety information concerning
your Dri-Eaz product. If you determine service is required, have your equipment model, serial number and
original proof of purchase available and ask for assistance with obtaining a return material authorization
(RMA).
GROUNDING INSTRUCTIONS
This unit’s plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance
with all local codes and ordinances.
WARNING! Improper connection of the equipmentgrounding conductor can result in a risk of electric
shock. Check with a qualified electrician or service
person if you are in doubt as to whether the outlets
are properly grounded. Do not modify the plugs provided with the appliance – if the plugs do not fit the
outlets, have proper outlets installed by a qualified
electrician.
This equipment is for use on circuits with a nominal rating of no more than 230V.
Handle the unit carefully
Always operate the unit on a stable, level surface. Do
not drop, throw, or place where it could fall. Rough treatment can damage the unit, and may create a hazardous
condition or void the warranty.
This unit intended for household and commercial use.
07-01899G F413-230V EU/UK 1 Legend Brands Holdings Ltd.

CONTROLS AND OPERATING
INSTRUCTIONS
Set unit upright
NOTICE: Always store, transport, and use the unit in
a horizontal position. If the unit is ever placed in a
vertical position, return it to the horizontal position
and let it stand for at least 30 minutes before turning
it on.
Positioning a Dehumidifier
For best results, operate your dehumidifiers in an enclosed area. Close all doors and windows that open to
the outside to maximize water removal efficiency. Place
your dehumidifier away from obstructions, and keep it
away from anything that could block airflow into and out
of the unit. For more information about creating an optimum drying environment, contact your local distributor.
Set up drain hose
This unit automatically pumps out water on a regular basis. This dehumidifier is equipped with a quick-connect
fitting for quick attachment to the provided 12 m drain
hose. Unwrap the entire hose and place the open end in
a sink, drain, bucket or outdoors – anywhere that water
can drain out safely. If you use a bucket or other container for water collection, check it regularly to prevent
overflows.
NOTICE: Uncoil and straighten the entire drain hose. Do
not leave any part of the hose coiled and do not place
the end of the hose higher than 6 m above the bottom of
the unit. Also check for kinks or other obstructions that
might restrict the flow of water. Obstructions may cause
a water backup and result in overflows.
Fig. A: Parts Identification
Carry handles
Control
panel
Air inlet
Cord and
hose storage
wraps.
Condensate
drain quickconnect
UNIT ON XXXX HRS
INLET XXX°C / INLET 00%
The first line of the display shows the total number of
hours the unit has been in operation. This value may be
reset to zero to track job hours (see “Job Hours Reset”
below). The second line of the display alternates between inlet temperature and inlet humidity.
Air outlet
Temp/RH
sensor
Remove/Insert
air filter here.
Plug in electrical cord
The unit should be plugged into a 230V/50Hz outlet.
Startup display and normal display modes
When unit is first plugged in to AC power, the control
panel display will briefly cycle through a series of
readouts. This is part of the unit’s self-diagnosis procedure and no user intervention is required.
Turn the unit on
The control panel has a display and a touchpad with four
keys. Press the
will now go through a compressor delay countdown (up
to sixty seconds in duration) and a self diagnostics process.
Once the compressor delay countdown and self-diagnostics are complete, the display will switch to normal
display mode.
07-01899G F413-230V EU/UK 2 Legend Brands Holdings Ltd.
ON/OFF to turn the unit on. The unit

User Settings Menu
Press and release to turn unit
Press to select next item in
Press to toggle or select values
in menu displayed.
Press and release to start purge.
A number of display settings may be changed by the
user. System information can also be displayed. These
items are accessed by pressing
DISPLAY MENU.
Each press of the key will display the next parameter.
When you reach the parameter you wish to adjust, press
MENU SELECTION to increase the value. Press
DISPLAY MENU again to accept the setting and re-start
the display cycle.
Note that only menu items followed by a greater-than
symbol ( > ) may be adjusted.
All settings and modes are discussed in detail in Control
Panel Guide.
CONTROL PANEL
DISPLAY
ON/OFF
DISPLAY
MENU
on
menu. Menu item will show in
Display will count down seconds remaining until purge is
complete.
PURGE PUMP
MENU
SELECTION /
UP KEY
Error messages
If the onboard diagnostics discover a problem, the unit
will display an error message. See “Error Messages,”
below, for an explanation of each message.
Control Panel Guide
ON/OFF. Press to turn the unit on or off. When the ma-
chine is turned on, the display normally reads PLEASE
WAIT COMP. DELAY and performs a numeral countdown for a maximum of 60 seconds to 0. This delay allows time for refrigerant pressures to equalize for easier
starting. Once the unit completes the compressor delay,
the display shows UNIT ON XX HRS and cycles between INLET XX°F and INLET XX%. NOTE: If no compressor delay countdown is displayed, a delay is not
necessary and the machine will begin operation immediately.
DISPLAY MENU. Press to cycle through the display of
additional dehumidifier conditions and User Settings. To
return to the main menu, press the ON/OFF key once.
MENU SELECTION. Press to change the values of the
"User Defined" settings. The MENU SELECTION key
acts as the UP key for adjusting the setpoint for Humidistat mode operation. See User Settings Menu (below)
for details.
PURGE. Press to empty water from the condensate
pump reservoir. The display will read PUMP PURGING
with a numeral countdown.
NOTE: During normal operation, the pump purges automatically.
Changing settings and viewing system information
Display setting changes and system information can be
accessed by pressing
of the key will display the next parameter (see list below). When you reach the parameter you wish to adjust,
press
Press
MENU SELECTION to increase the value.
DISPLAY MENU again to accept the setting
and re-start the display cycle
Note that only menu items followed by a greater-than
symbol ( > ) may be adjusted.
DISPLAY MENU. Each press
07-01899G F413-230V EU/UK 3 Legend Brands Holdings Ltd.