The DriForce InterAir Drying System allows the restorer to direct high-pressure air into wet walls,
behind cabinets, and into other hard-to-reach structures with minimal disruption to materials.
Provides fast, effective drying in all types of assemblies and materials.
Patents: www.LBpatents.com
READ AND SAVE THESE INSTRUCTIONS
WARNING! To reduce the risk of fire or electric shock, do
not use this fan with any solid-state speed control device.
WARNING! Unit must be grounded. Do not use with an
extension cord. Connect only to an outlet provided with a
ground fault interrupting device.
WARNING! Never operate a unit with a damaged power
cord, as this may lead to electrical or fire hazards. If power
cord is damaged, it must be replaced by a cord of the same
type and amperage rating.
WARNING! Do not touch grills when unit is operating.
NOTICE: Keep motor dry. For indoor use only.
NOTICE: Unplug when not in use or when moving unit.
WARNING: Do not allow children to play with or around the
unit. Be sure the unit is inaccessible to children when not
attended.
NOTICE: Always operate the unit on a stable, level surface
so it cannot fall and cause injury.
WARNING! Do not alter or modify your Dri-Eaz product in
any way. Use only replacement parts authorized by Dri-Eaz
Products, Inc. Modifications or use of unapproved parts
could create a hazard and will void your warranty. Contact
your authorized Dri-Eaz distributor for assistance.
DRIFORCE AIR DRYING SYSTEM (ADS) COMPONENTS
(91 ft.)
hose (thirteen
7 ft./2 m sec-
connectors (×2)
fler/filter
07-00274H F211-115V 1 Dri-Eaz Products, Inc.
endcaps (×4)
ON/OFF
shown)
DRIFORCE BLOWER
Vacuum IN
Blower OUT
Wrap cord
BEFORE YOU BEGIN
Warranty registration
Please visit warranty.drieaz.com to register your purchase.
Registration allows us to better assist you with using, maintaining or servicing your equipment and to contact you in
case we have important safety information concerning your
Dri-Eaz product. If you determine service is required, have
your equipment model, serial number and original proof of
purchase available and call your distributor for assistance
with obtaining a return material authorization (RMA).
around unit
when not in
use.
switch in
base (not
when value is added by avoiding the detachment of
wall baseboards.
Making air access holes
Punch holes with a carpet awl or use a drill with a
3⁄16 in. bit. Create at least one hole between each set
of studs and about 2 in. above the floor. An electronic
stud finder can be used to locate studs and find the
center of the cavity.
Larger holes are more time-consuming to patch, and
may decrease efficiency by leaking air. Try to reduce
the need for later repairs by placing the holes behind
the rubber wainscoting or cove base, or behind trim
that is easily reinstalled over the holes.
Steel Studs
Steel studs are common in commercial building s.
They are set in a channel that can hold large volumes
of water. To access these areas, drill holes approximately ½ inch from the floor at a downward angle. Take
care, however, not to immerse the ends of the tubes in any
standing water that may be present.
Ceilings and Cabinets
The larger lumber sizes and structural cavitie s in ceilings
will require more air airflow to dry properly.
Moisture under and behind cabinets may be difficult to detect, but it is safest to assume that moisture is present if
water has flowed through these assemblies. Make sure to
provide as much airflow as possible. If you cannot properly
OPERATING INSTRUCTIONS
IMPORTANT: Extract standing water before attempting
to dry. Do NOT use the DriForce to extract standing
water of any kind.
Tools
Pencil, tape measure, razor knife, drywall taping knife,
small pry bar, nail puller, screw driver, a carpet awl, a drill
with a 3⁄16 in. bit. An electronic stud finder is also useful.
Preparing Walls, Cabinets and other Assemblies for Drying
Walls
Wall drying using an inter-air drying system can be accomplished with or without baseboards pres ent. A fter inspecting walls, insulation, and baseboards, and after evaluating
paint finish considerations, proceed in the manner that delivers the most value to the customer.
Remove baseboard or cove base. First, use a razor knife to
score along the top of the base where it meets the wall, to
reduce damage to the painted surfaces and make a professional re-installation easier. When prying base away
from the wall, protect the wall surface by inserting a drywall
knife between the pry bar and the wall. Pull remaining nails
out of the wall, or through the back of the baseboard. Write
a number on the wall and the corresponding base so you
will know where to reinstall it. However, drying success can
also be achieved by making the wall penetrations immediately above the top of baseboard and proceeding to dry
with the baseboards in place. This a necessary procedure
where there is a desire to save a wall with a tiled wall base,
07-00274H F211-115V 2 Dri-Eaz Products, Inc.
The DriForce and the Air Drying System can deliver air to structural cavities in walls, ceilings, under and above cabinets, and
many other areas.
The ADS co nnects to the DriForce blower outlet and attaches
to a manifold with a standard hose cuff. Supply tubes run
from the manifold to injectors that are inserted into a wall o r
other structural cavity.
Manifold
Tubing
Tubing
Tubing locations
access all interior spaces, the cabinets may need to be
removed.
NOTICE: Do not use the DriForce to extract liquid water or
debris of any kind. This may damage the unit and void the
warranty.
After determining the number and length of hose assemblies and manifolds, set up the ADS system. Preassembling the manifolds, tubing and injectors will save
considerable time.
Supply tube configuration
Two 200 ft. (60 m) lengths of of ⅜ in. (0.375 mm) ID ai r supply
are provided. This tubing can be cut to length with a
tubing
pair of sturdy scissors or a utility knife. We recommend the
cutting following tubing lengths to create a setup suitable
for most standard wall-drying jobs:
1. Set up THREE manifolds with the following lengths
of tubing:
Manifold
no.
1 4
2 4
3 4
Tubing
quantity
Tubing
length
4 ft.
1.2 m
3½ ft.
1 m
1 ft.
30 cm
Tubing locations
on manifold outlets
Outlets 1, 2, 11
and 12
Outlets 3, 4, 9 and 10
Outlets 5, 6, 7 and 8
2. Set up the remaining FIVE manifolds with the following lengths of tubing:
Diagram shows two inline ADS lines (left), and two double-ADS
lines running from a T-fitting. It also shows tubing layouts for
one or two injectors into each wall cavity.
DriForce Blower Setup
The DriForce Blower is equipped with a blower outlet, a
vacuum inlet, a power switch and a power cord. Plug in unit
to an appropriate grounded 115V outlet rated for 15 amps.
Attach vacuum hoses to the vacuum inlet and/or blower
outlet.
Set the DriForce blower out of high traffic areas to minimize
a trip-and-fall hazard from the blower and the ADS.
NOTE: The muffler/filter supplied with the DriForce should
only be installed when using the DriForce in the Air Injection (Blower) mode, described under Phase 2 below. Do
not use the muffler-filter w hen usin g with the DriForce in
the air extraction mode (Phase 1). The filter is not intended
to be used on the inlet (vacuum) side of the DriForce.
Switch power on and off with the toggle switch, found in the
base of the unit.
Air Drying System (ADS) Setup
Manifold configuration
Next, determine the number of manifolds needed for the
job. The following setup will deliver 25 to 30 air exchanges
per hour in each cavity, which is effective for most situations. Use a formula of one manifold (each manifo ld has 12
injectors) for each 14 feet of interior 2 × 4 framed wall. For
2 × 6 exterior framed walls, common walls in apartments
and condos, double-sheeted fire walls, and dense or waterresistant covered walls, use a formula of one manifold (12
injectors) for each 7 feet of wall.
07-00274H F211-115V 3 Dri-Eaz Products, Inc.
no.
4 2
5 2
6 2
7 2
8 2
9 2
To install the tubing, slide the one end of the tubing over
the manifold outlet nipple and insert an injector in the other
end.
Tightly seal off the last manifold on each run of ADS with
an end-cap plug. Now place the injectors into the holes you
have drilled or punched in the wall, cabinet or other assembly.
Ensure that all T-fittin gs, hos e cuff s, mani fold s, sup ply
lines, and injectors are properly installed. Attach the ADS to
the DriForce. Plug in the DriForce and switch it on briefly,
checking all connections for air leakage. If needed, use a
hose clamp to seal off any air leakage where the vinyl
products connect up to hose barbs, etc.
quantity
Length
7½ ft.
2.3 m
6½ ft.
2.0 m
5½ ft.
1.7 m
4½ ft.
1.4 m
2½ ft.
0.8 m
1 ft.
30 cm
on manifold outlets
Outlets 1 and 12
Outlets 2 and 11
Outlets 3 and 10
Outlets 4 and 9
Outlets 5 and 8
Outlets 6 and 7
Drying Procedure
Phase 1: Air Extraction (Vacuum) Drying
Attach the ADS to the vacuum inlet of the DriForce
blower unit and switch unit on.
Use the air extraction (vacuum) mode to draw humid air
from structural cavities.
Operate Phase 1 until the humidity of the air being drawn
from the affected area is approximately the same as the
humidity in an unaffected area of the job. You can use a
hygrometer to compare RH readings between the outlet of
the DriForce and the surrounding area.
NOTE: Be sure to attach the vacuum hose to the DriForce
outlet and direct the exhaust air outside the structure. Do
not use the muffler-filter that is supplied with the DriForce in
the air extraction mode. This filter is not a HEPA-grade
filter, and will not properly capture contaminants that may
be drawn into the DriForce. Use the muffler-filter only in the
injection (blower) mode, described below.
Phase 2: Air Injection (Blower) Drying
Attach the ADS from the vacuum to the pressure outlet
of the DriForce, install the muffler-filter on the air intake, and switch unit on.
Once the humidity inside the structural cavity equals the
humidity in the room, it is time to switch to the air injection
mode. Injecting room air into the structural cavities will help
continue the drying process. This is especially true if you
are dehumidifying the room air.
TIP: When drying inside walls, use an awl-punch or drill to
create a small vent holes placed just above the highest
moisture point on the wall. This will provide a vent and help
to speed up the drying process by allowing greater air flow
through the affected materials. A small hole can be easily
patched.
TIP: To maximize drying in walls that wainscoted, tilecovered, double-sheeted, or covered with vinyl wall paper
or impermeable paint, as well as lath and plaster walls,
firewalls and insulated walls, place additional injectors per
linear foot.
TIP: Accelerate drying with dehumidifiers. To increase
drying rates during Phase 2, use a dehumidifier to supply
dry air directly into the DriForce. Position the dry air outlet
of a dehumidifier near the DriForce air inlet, or duct the
dehumidifier outlet toward the DriForce inlet. Desiccant dehumidifiers are especially useful for this purpose, as
the extremely dry air they produce can accelerate the drying of dense materials and assemblies.
NOTICE: Do NOT tape or seal the dehumidifier ducting to
the DriForce inlet, as this could unbalance the airflow
through the dehumidifier and possibly damage the dehumidifier.
Odor and Mold Control
If you suspect that mold and mildew may be growing inside
cavities, follow the appropriate industry mold remediation
procedures and safety standards.
MAINTENANCE
WARNING: Always unplug unit prior to servicing or cleaning.
As needed
Check both the inlet and outlet of the DriForce unit for obstructions or debris after each use.
Inspect the muffler-filter, and clean as needed by vacuuming or washing. Check manifolds, tubing, injectors and other ADS components, and replace if needed.
Clean the exterior of the DriForce and ADS components
with a vinyl cleaner and protectant.
Parts, service, and maintenance and warranty information
are available from your Dri-Eaz distributor.
SPECIFICATIONS
DriForce InterAir Drying System (F211-115V)
BASE UNIT
Dimensions (H × L × D) 14 × 14 × 12 in. | 35 × 35 × 30 cm
Amperage 5.4 amps
Power 115V / 60Hz
Total system airflow (max.) 100 CFM | 2.3 CMM
Working static pressure (water lift) 38 in. | 97 cm
Weight (base unit only) 14.5 lbs. | 6.3 kg
Safety ETL listed to UL 507 and CSA C22.2 No. 113
AIR DELIVERY SYSTEM (ADS)
Crush-proof ADS tubing 91 ft. (28 m).of 1½ in. (3.8 cm) tubing. Pre-cut into thirteen 7 ft. (2 m) sections.
Injector hole size Less than ¼ in. (6 mm)
Flexible tubing 400 ft. (122 m) of ⅜ in. (0.375 mm) ID tubing
Carrying/storage system 2 suitcase-style duffle bags with handle and wheels
Drying modes Either positive or negative pressure
Parts included 100 injectors, 8 manifolds (12 outlets each), 4 manifold endcaps, 4 coupler fittings, 2 hose clamps, 2
El InterAir Sistema de Secado de DriForce permite al reparador dirigir aire a alta presión contra paredes
húmedas, detrás de los gabinetes y sobre otras estructuras di fíciles de alcanzar, con un mínimo efecto sobre
los materiales. Permite un secado rápido y eficaz en todo tipo de montajes y materiales.
Patentes: www.LBpatents.com
LEA Y CONSERVE ESTAS INSTRUCCIONES
¡ADVERTENCIA! Para reducir el riesgo de incen dio o
descarga eléctrica, no use este ventilador con ningún
dispositivo de control de velocidad sólido.
¡ADVERTENCIA! La unidad debe tener puesta a tierra. No
utilizar con un cable de extensión. Conectar sola me nte a
un toma provisto de un dispositivo de interrupción por f all o
con puesta a tierra.
¡ADVERTENCIA! Nunca haga funcionar una unidad con el
cable de alimentación dañado, ya que puede generar
riesgos eléctricos o de incendio. Si el cable está dañado,
debe ser sustituido por uno del mismo tipo y amperaje.
¡ADVERTENCIA! No toque las parrillas cuando la unidad
esté en funcionamiento.
AVISO: Mantener seco el motor. Sólo para uso interior.
AVISO: Desenchufar cuando no esté en uso o cuando esté
desplazando la unidad.
ADVERTENCIA: No permita que los niños jueguen con o
cerca de la unidad. Asegúrese de que la unidad no quede
accesible a los niños cuando no se la esté controlando.
AVISO: Siempre operar la unidad sobre superficie estable y
nivelada para que no pueda caerse y causar lesiones.
¡ADVERTENCIA! No modificar su producto Dri-Eaz. Utilice
sólo repuestos autorizados por Dri-Eaz Products, Inc. Las
modificaciones o el uso de piezas no autorizadas podrían
provocar un accidente y la nulidad de la garantía. Póngase en
contacto con su distribuidor autorizado de Dri-Eaz para obtener
COMPONENTES DEL SISTEMA DE SECADO POR AIRE (ADS) DRIFORCE
(91 pies)
llevar (× 2)
DriForce
del colector
(× 2)
filtro DriForce
07-00274H F211-115V 5 Dri-Eaz Products, Inc.
prueba de
aplastamiento
(13 tramos de 7
pies / 2 m).
colector (× 4)
Loading...
+ 9 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.