Dri-Eaz DriForce InterAir F211-115V Owner's Manual

Manifolds (×8)
Hose barbs (×5)
Crush-proof
tions)
Carry bags (×2)
DriForce muf-
DriForce unit
Manifold T-
ADS tubing Injectors (×100)
Manifold
WARNING
Owner’s Manual
DriForce™ InterAir Drying System
Model F211-115V
DRI-EAZ PRODUCTS, INC.
15180 Josh Wilson Road, Burlington, WA 98233
The DriForce InterAir Drying System allows the restorer to direct high-pressure air into wet walls, behind cabinets, and into other hard-to-reach structures with minimal disruption to materials. Provides fast, effective drying in all types of assemblies and materials.
Patents: www.LBpatents.com
READ AND SAVE THESE INSTRUCTIONS
WARNING! To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
WARNING! Unit must be grounded. Do not use with an extension cord. Connect only to an outlet provided with a ground fault interrupting device.
WARNING! Never operate a unit with a damaged power cord, as this may lead to electrical or fire hazards. If power
cord is damaged, it must be replaced by a cord of the same type and amperage rating.
WARNING! Do not touch grills when unit is operating. NOTICE: Keep motor dry. For indoor use only. NOTICE: Unplug when not in use or when moving unit. WARNING: Do not allow children to play with or around the
unit. Be sure the unit is inaccessible to children when not attended.
NOTICE: Always operate the unit on a stable, level surface so it cannot fall and cause injury.
WARNING! Do not alter or modify your Dri-Eaz product in any way. Use only replacement parts authorized by Dri-Eaz Products, Inc. Modifications or use of unapproved parts could create a hazard and will void your warranty. Contact your authorized Dri-Eaz distributor for assistance.
DRIFORCE AIR DRYING SYSTEM (ADS) COMPONENTS
(91 ft.)
hose (thirteen 7 ft./2 m sec-
connectors (×2)
fler/filter
07-00274H F211-115V 1 Dri-Eaz Products, Inc.
endcaps (×4)
ON/OFF
shown)
DRIFORCE BLOWER
Vacuum IN
Blower OUT
Wrap cord
BEFORE YOU BEGIN
Warranty registration
Please visit warranty.drieaz.com to register your purchase. Registration allows us to better assist you with using, main­taining or servicing your equipment and to contact you in case we have important safety information concerning your Dri-Eaz product. If you determine service is required, have your equipment model, serial number and original proof of purchase available and call your distributor for assistance with obtaining a return material authorization (RMA).
around unit when not in use.
switch in base (not
when value is added by avoiding the detachment of wall baseboards.
Making air access holes
Punch holes with a carpet awl or use a drill with a 3⁄16 in. bit. Create at least one hole between each set of studs and about 2 in. above the floor. An electronic stud finder can be used to locate studs and find the center of the cavity.
Larger holes are more time-consuming to patch, and may decrease efficiency by leaking air. Try to reduce the need for later repairs by placing the holes behind the rubber wainscoting or cove base, or behind trim that is easily reinstalled over the holes.
Steel Studs
Steel studs are common in commercial building s. They are set in a channel that can hold large volumes
of water. To access these areas, drill holes approxi­mately ½ inch from the floor at a downward angle. Take care, however, not to immerse the ends of the tubes in any standing water that may be present.
Ceilings and Cabinets
The larger lumber sizes and structural cavitie s in ceilings will require more air airflow to dry properly.
Moisture under and behind cabinets may be difficult to de­tect, but it is safest to assume that moisture is present if water has flowed through these assemblies. Make sure to provide as much airflow as possible. If you cannot properly
OPERATING INSTRUCTIONS
IMPORTANT: Extract standing water before attempting to dry. Do NOT use the DriForce to extract standing water of any kind.
Tools
Pencil, tape measure, razor knife, drywall taping knife, small pry bar, nail puller, screw driver, a carpet awl, a drill with a 3⁄16 in. bit. An electronic stud finder is also useful.
Preparing Walls, Cabinets and other As­semblies for Drying
Walls
Wall drying using an inter-air drying system can be accom­plished with or without baseboards pres ent. A fter inspect­ing walls, insulation, and baseboards, and after evaluating paint finish considerations, proceed in the manner that de­livers the most value to the customer.
Remove baseboard or cove base. First, use a razor knife to score along the top of the base where it meets the wall, to reduce damage to the painted surfaces and make a pro­fessional re-installation easier. When prying base away from the wall, protect the wall surface by inserting a drywall knife between the pry bar and the wall. Pull remaining nails out of the wall, or through the back of the baseboard. Write a number on the wall and the corresponding base so you will know where to reinstall it. However, drying success can also be achieved by making the wall penetrations immedi­ately above the top of baseboard and proceeding to dry with the baseboards in place. This a necessary procedure
where there is a desire to save a wall with a tiled wall base,
07-00274H F211-115V 2 Dri-Eaz Products, Inc.
The DriForce and the Air Drying System can deliver air to struc­tural cavities in walls, ceilings, under and above cabinets, and many other areas.
The ADS co nnects to the DriForce blower outlet and attaches to a manifold with a standard hose cuff. Supply tubes run from the manifold to injectors that are inserted into a wall o r other structural cavity.
Manifold
Tubing
Tubing
Tubing locations
access all interior spaces, the cabinets may need to be removed.
NOTICE: Do not use the DriForce to extract liquid water or debris of any kind. This may damage the unit and void the warranty.
After determining the number and length of hose assem­blies and manifolds, set up the ADS system. Pre­assembling the manifolds, tubing and injectors will save considerable time.
Supply tube configuration
Two 200 ft. (60 m) lengths of of ⅜ in. (0.375 mm) ID ai r supply
are provided. This tubing can be cut to length with a
tubing
pair of sturdy scissors or a utility knife. We recommend the cutting following tubing lengths to create a setup suitable for most standard wall-drying jobs:
1. Set up THREE manifolds with the following lengths of tubing:
Manifold
no.
1 4
2 4
3 4
Tubing
quantity
Tubing
length
4 ft.
1.2 m 3½ ft.
1 m 1 ft.
30 cm
Tubing locations
on manifold outlets
Outlets 1, 2, 11 and 12
Outlets 3, 4, 9 and 10
Outlets 5, 6, 7 and 8
2. Set up the remaining FIVE manifolds with the follow­ing lengths of tubing:
Diagram shows two inline ADS lines (left), and two double-ADS lines running from a T-fitting. It also shows tubing layouts for one or two injectors into each wall cavity.
DriForce Blower Setup
The DriForce Blower is equipped with a blower outlet, a vacuum inlet, a power switch and a power cord. Plug in unit to an appropriate grounded 115V outlet rated for 15 amps.
Attach vacuum hoses to the vacuum inlet and/or blower outlet.
Set the DriForce blower out of high traffic areas to minimize a trip-and-fall hazard from the blower and the ADS.
NOTE: The muffler/filter supplied with the DriForce should only be installed when using the DriForce in the Air Injec­tion (Blower) mode, described under Phase 2 below. Do not use the muffler-filter w hen usin g with the DriForce in the air extraction mode (Phase 1). The filter is not intended to be used on the inlet (vacuum) side of the DriForce.
Switch power on and off with the toggle switch, found in the base of the unit.
Air Drying System (ADS) Setup
Manifold configuration
Next, determine the number of manifolds needed for the job. The following setup will deliver 25 to 30 air exchanges per hour in each cavity, which is effective for most situa­tions. Use a formula of one manifold (each manifo ld has 12 injectors) for each 14 feet of interior 2 × 4 framed wall. For 2 × 6 exterior framed walls, common walls in apartments and condos, double-sheeted fire walls, and dense or water­resistant covered walls, use a formula of one manifold (12 injectors) for each 7 feet of wall.
07-00274H F211-115V 3 Dri-Eaz Products, Inc.
no.
4 2
5 2
6 2
7 2
8 2
9 2
To install the tubing, slide the one end of the tubing over the manifold outlet nipple and insert an injector in the other end.
Tightly seal off the last manifold on each run of ADS with an end-cap plug. Now place the injectors into the holes you have drilled or punched in the wall, cabinet or other as­sembly.
Ensure that all T-fittin gs, hos e cuff s, mani fold s, sup ply lines, and injectors are properly installed. Attach the ADS to the DriForce. Plug in the DriForce and switch it on briefly, checking all connections for air leakage. If needed, use a hose clamp to seal off any air leakage where the vinyl products connect up to hose barbs, etc.
quantity
Length
7½ ft.
2.3 m 6½ ft.
2.0 m 5½ ft.
1.7 m 4½ ft.
1.4 m 2½ ft.
0.8 m 1 ft.
30 cm
on manifold outlets
Outlets 1 and 12
Outlets 2 and 11
Outlets 3 and 10
Outlets 4 and 9
Outlets 5 and 8
Outlets 6 and 7
Drying Procedure
Phase 1: Air Extraction (Vacuum) Drying
Attach the ADS to the vacuum inlet of the DriForce blower unit and switch unit on.
Use the air extraction (vacuum) mode to draw humid air from structural cavities.
Operate Phase 1 until the humidity of the air being drawn from the affected area is approximately the same as the humidity in an unaffected area of the job. You can use a hygrometer to compare RH readings between the outlet of the DriForce and the surrounding area.
NOTE: Be sure to attach the vacuum hose to the DriForce outlet and direct the exhaust air outside the structure. Do not use the muffler-filter that is supplied with the DriForce in the air extraction mode. This filter is not a HEPA-grade filter, and will not properly capture contaminants that may be drawn into the DriForce. Use the muffler-filter only in the injection (blower) mode, described below.
Phase 2: Air Injection (Blower) Drying
Attach the ADS from the vacuum to the pressure outlet of the DriForce, install the muffler-filter on the air in­take, and switch unit on.
Once the humidity inside the structural cavity equals the humidity in the room, it is time to switch to the air injection mode. Injecting room air into the structural cavities will help continue the drying process. This is especially true if you are dehumidifying the room air.
TIP: When drying inside walls, use an awl-punch or drill to create a small vent holes placed just above the highest moisture point on the wall. This will provide a vent and help to speed up the drying process by allowing greater air flow through the affected materials. A small hole can be easily patched.
TIP: To maximize drying in walls that wainscoted, tile­covered, double-sheeted, or covered with vinyl wall paper or impermeable paint, as well as lath and plaster walls,
firewalls and insulated walls, place additional injectors per linear foot.
TIP: Accelerate drying with dehumidifiers. To increase drying rates during Phase 2, use a dehumidifier to supply dry air directly into the DriForce. Position the dry air outlet of a dehumidifier near the DriForce air inlet, or duct the dehumidifier outlet toward the DriForce inlet. Desiccant dehumidifiers are especially useful for this purpose, as the extremely dry air they produce can accelerate the dry­ing of dense materials and assemblies.
NOTICE: Do NOT tape or seal the dehumidifier ducting to the DriForce inlet, as this could unbalance the airflow through the dehumidifier and possibly damage the dehu­midifier.
Odor and Mold Control
If you suspect that mold and mildew may be growing inside cavities, follow the appropriate industry mold remediation procedures and safety standards.
MAINTENANCE
WARNING: Always unplug unit prior to ser­vicing or cleaning.
As needed
Check both the inlet and outlet of the DriForce unit for ob­structions or debris after each use.
Inspect the muffler-filter, and clean as needed by vacuum­ing or washing. Check manifolds, tubing, injectors and oth­er ADS components, and replace if needed.
Clean the exterior of the DriForce and ADS components with a vinyl cleaner and protectant.
Parts, service, and maintenance and warranty information are available from your Dri-Eaz distributor.
SPECIFICATIONS
DriForce InterAir Drying System (F211-115V)
BASE UNIT
Dimensions (H × L × D) 14 × 14 × 12 in. | 35 × 35 × 30 cm Amperage 5.4 amps Power 115V / 60Hz Total system airflow (max.) 100 CFM | 2.3 CMM Working static pressure (water lift) 38 in. | 97 cm Weight (base unit only) 14.5 lbs. | 6.3 kg Safety ETL listed to UL 507 and CSA C22.2 No. 113
AIR DELIVERY SYSTEM (ADS)
Crush-proof ADS tubing 91 ft. (28 m).of 1½ in. (3.8 cm) tubing. Pre-cut into thirteen 7 ft. (2 m) sections. Injector hole size Less than ¼ in. (6 mm) Flexible tubing 400 ft. (122 m) of in. (0.375 mm) ID tubing Carrying/storage system 2 suitcase-style duffle bags with handle and wheels Drying modes Either positive or negative pressure Parts included 100 injectors, 8 manifolds (12 outlets each), 4 manifold endcaps, 4 coupler fittings, 2 hose clamps, 2
T-fittings, 13 hose assemblies with cuffs, 25 tube extender connections, 1 muffler.
07-00274H F211-115V 4 Dri-Eaz Products, Inc.
MANUAL DEL USUARIO
Colectores (× 8)
Conectores de mangueras (× 5)
Manguera a
Bolsos para
Silenciador /
Unidad
Conectores T
Tubería ADS Inyectores (×
Tapas del
ADVERTENCIA
DriForce™ InterAir Sistema de Secado
Modelo F211-115V
DRI-EAZ PRODUCTS, INC.
15180 Josh Wilson Road, Burlington, WA 98233
Teléfono: 800-932-3030 Fax: 360-757-7950 www.dri-eaz.com
El InterAir Sistema de Secado de DriForce permite al reparador dirigir aire a alta presión contra paredes húmedas, detrás de los gabinetes y sobre otras estructuras di fíciles de alcanzar, con un mínimo efecto sobre los materiales. Permite un secado rápido y eficaz en todo tipo de montajes y materiales.
Patentes: www.LBpatents.com
LEA Y CONSERVE ESTAS INSTRUCCIONES
¡ADVERTENCIA! Para reducir el riesgo de incen dio o descarga eléctrica, no use este ventilador con ningún dispositivo de control de velocidad sólido.
¡ADVERTENCIA! La unidad debe tener puesta a tierra. No utilizar con un cable de extensión. Conectar sola me nte a un toma provisto de un dispositivo de interrupción por f all o con puesta a tierra.
¡ADVERTENCIA! Nunca haga funcionar una unidad con el cable de alimentación dañado, ya que puede generar
riesgos eléctricos o de incendio. Si el cable está dañado, debe ser sustituido por uno del mismo tipo y amperaje.
¡ADVERTENCIA! No toque las parrillas cuando la unidad esté en funcionamiento.
AVISO: Mantener seco el motor. Sólo para uso interior. AVISO: Desenchufar cuando no esté en uso o cuando esté
desplazando la unidad. ADVERTENCIA: No permita que los niños jueguen con o
cerca de la unidad. Asegúrese de que la unidad no quede accesible a los niños cuando no se la esté controlando.
AVISO: Siempre operar la unidad sobre superficie estable y nivelada para que no pueda caerse y causar lesiones.
¡ADVERTENCIA! No modificar su producto Dri-Eaz. Utilice sólo repuestos autorizados por Dri-Eaz Products, Inc. Las modificaciones o el uso de piezas no autorizadas podrían provocar un accidente y la nulidad de la garantía. Póngase en contacto con su distribuidor autorizado de Dri-Eaz para obtener
COMPONENTES DEL SISTEMA DE SECADO POR AIRE (ADS) DRIFORCE
(91 pies)
llevar (× 2)
DriForce
del colector (× 2)
filtro DriForce
07-00274H F211-115V 5 Dri-Eaz Products, Inc.
prueba de aplastamiento (13 tramos de 7 pies / 2 m).
colector (× 4)
Loading...
+ 9 hidden pages