Drieaz DriForce F211, DriForce F211-AK, DriForce F211-BU Owner's Manual

Manifolds (×8)
Hose barbs (×5)
Crush-proof
tions)
Carry bags (×2)
DriForce muf­fler/filter
DriForce unit
Manifold T-con-
ADS tubing Injectors (×100)
Manifold endcaps (×4)
DRIFORCE AIR DRYING SYSTEM (ADS) COMPONENTS
WARNING
Owner’s Manual
DriForce™ InterAir Drying System
Models F211, F211-AK, F211-BU
DRI-EAZ PRODUCTS, INC.
Phone: 800-932-3030 Fax: 360-757-7950 LegendBrandsRestoration.com
The DriForce InterAir Drying System allows the restorer to direct high-pressure air into wet walls, behind cabinets, and into other hard-to-reach structures with minimal disruption to materials. Provides fast, effective drying in all types of assemblies and materials.
Patents: www.LBpatents.com
REA D A N D S A V E T H E S E I N S T R U C T I O N S
WARNING! To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
WARNING! Unit must be grounded. Do not use with an ex­tension cord. Connect only to an outlet provided with a ground fault interrupting device.
WARNING! Do not touch grills when unit is operating.
(91 ft.)
NOTICE: Keep motor dry. For indoor use only. NOTICE: Unplug when not in use or when moving unit. WARNING: Do not allow children to play with or around the
unit. Be sure the unit is inaccessible to children when not attended.
NOTICE: Always operate the unit on a stable, level surface so it cannot fall and cause injury.
WARNING! Do not alter or modify your Dri-Eaz product in any way. Use only replacement parts authorized by Dri-Eaz Products, Inc. Modifications or use of unapproved parts could create a hazard and will void your warranty. Contact your authorized Dri-Eaz distributor for assistance.
WARNING! a) Do not operate any fan with a damaged cord or plug. Dis-
card fan or return to an authorized service facility for exami­nation and/or repair.
hose (thirteen 7 ft./2 m sec-
nectors (×2)
07-00274K F211, F211-AK, F211-BU 1 Dri-Eaz Products, Inc.
many other areas.
ON/OFF
shown)
DRIFORCE BLOWER
Vacuum IN
Blower OUT
Wrap cord
around unit when not in use.
switch in base (not
b) Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
WARNING: This product and other substances that may become airborne from its use contain
chemicals, including lead and phthalates, known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, go to P65Warnings.ca.gov
BEFORE YOU BEGIN
the wall, protect the wall surface by inserting a drywall knife between the pry bar and the wall. Pull remaining nails out of the wall, or through the back of the base­board. Write a number on the wall and the corre­sponding base so you will know where to reinstall it. However, drying success can also be achieved by making the wall penetrations immediately above the top of baseboard and proceeding to dry with the base­boards in place. This a necessary procedure where there is a desire to save a wall with a tiled wall base, when value is added by avoiding the detachment of wall baseboards.
Making air access holes
Punch holes with a carpet awl or use a drill with a 3⁄16 in. bit. Create at least one hole between each set of studs and about 2 in. above the floor. An electronic stud finder can be used to locate studs and find the center of the cavity.
Larger holes are more time-consuming to patch, and may decrease efficiency by leaking air. Try to reduce the need for later repairs by placing the holes behind the rubber wainscoting or cove base, or behind trim that is easily rein­stalled over the holes.
Steel Studs
Steel studs are common in commercial buildings. They are set in a channel that can hold large volumes of water. To access these areas, drill holes approximately ½ inch from
Warranty registration
Please visit warranty.drieaz.com to register your purchase. Registration allows us to better assist you with using, main­taining or servicing your equipment and to contact you in case we have important safety information concerning your Dri-Eaz product. If you determine service is required, have your equipment model, serial number and original proof of purchase available and call your distributor for assistance with obtaining a return material authorization (RMA).
OPERATING INSTRUCTIONS
IMPORTANT: Extract standing water before attempting to dry. Do NOT use the DriForce to extract standing wa­ter of any kind.
Tools
Pencil, tape measure, razor knife, drywall taping knife, small pry bar, nail puller, screw driver, a carpet awl, a drill with a 3⁄16 in. bit. An electronic stud finder is also useful.
Preparing Walls, Cabinets and other As­semblies for Drying
Walls
Wall drying using an inter-air drying system can be accom­plished with or without baseboards present. After inspect­ing walls, insulation, and baseboards, and after evaluating paint finish considerations, proceed in the manner that de­livers the most value to the customer.
Remove baseboard or cove base. First, use a razor knife to score along the top of the base where it meets the wall, to reduce damage to the painted surfaces and make a profes­sional re-installation easier. When prying base away from
07-00274K F211, F211-AK, F211-BU 2 Dri-Eaz Products, Inc.
The DriForce and the Air Drying System can deliver air to struc­tural cavities in walls, ceilings, under and above cabinets, and
The ADS connects to the DriForce blower outlet and attaches to a manifold with a standard hose cuff. Supply tubes run from the manifold to injectors that are inserted into a wall or other structural cavity.
Manifold
no.
Tubing
quantity
Tubing
length
Tubing locations
on manifold outlets
1
4
4 ft.
1.2 m
Outlets 1, 2, 11 and 12
2
4
3½ ft.
1 m
Outlets 3, 4, 9 and 10
3
4
1 ft.
30 cm
Outlets 5, 6, 7 and 8
Manifold
no.
Tubing
quantity
Tubing Length
Tubing locations
on manifold outlets
4
2
7½ ft.
2.3 m
Outlets 1 and 12
5
2
6½ ft.
2.0 m
Outlets 2 and 11
6
2
5½ ft.
1.7 m
Outlets 3 and 10
7
2
4½ ft.
1.4 m
Outlets 4 and 9
8
2
2½ ft.
0.8 m
Outlets 5 and 8
9
2
1 ft.
30 cm
Outlets 6 and 7
Diagram shows two inline ADS lines (left), and two double-ADS lines running from a T-fitting. It also shows tubing layouts for one or two injectors into each wall cavity.
the floor at a downward angle. Take care, however, not to immerse the ends of the tubes in any standing water that may be present.
Ceilings and Cabinets
The larger lumber sizes and structural cavities in ceilings will require more air airflow to dry properly.
Moisture under and behind cabinets may be difficult to de­tect, but it is safest to assume that moisture is present if water has flowed through these assemblies. Make sure to provide as much airflow as possible. If you cannot properly access all interior spaces, the cabinets may need to be re­moved.
NOTICE: Do not use the DriForce to extract liquid water or debris of any kind. This may damage the unit and void the warranty.
Air Drying System (ADS) Setup
Manifold configuration
Next, determine the number of manifolds needed for the job. The following setup will deliver 25 to 30 air exchanges per hour in each cavity, which is effective for most situa­tions. Use a formula of one manifold (each manifold has 12 injectors) for each 14 feet of interior 2 × 4 framed wall. For 2 × 6 exterior framed walls, common walls in apartments and condos, double-sheeted fire walls, and dense or water­resistant covered walls, use a formula of one manifold (12 injectors) for each 7 feet of wall.
After determining the number and length of hose assem­blies and manifolds, set up the ADS system. Pre-assem­bling the manifolds, tubing and injectors will save consider­able time.
Supply tube configuration
Two 200 ft. (60 m) lengths of in. (0.375 mm) ID air supply tubing are provided. This tubing can be cut to length with a pair of sturdy scissors or a utility knife. We recommend the cutting following tubing lengths to create a setup suitable for most standard wall-drying jobs:
1. Set up THREE manifolds with the following lengths of tubing:
DriForce Blower Setup
The DriForce Blower is equipped with a blower outlet, a vacuum inlet, a power switch and a power cord. Plug in unit to an appropriate grounded 115V outlet rated for 15 amps.
Attach vacuum hoses to the vacuum inlet and/or blower outlet.
Set the DriForce blower out of high traffic areas to minimize a trip-and-fall hazard from the blower and the ADS.
NOTE: The muffler/filter supplied with the DriForce should only be installed when using the DriForce in the Air Injec­tion (Blower) mode, described under Phase 2 below. Do not use the muffler-filter when using with the DriForce in the air extraction mode (Phase 1). The filter is not intended to be used on the inlet (vacuum) side of the DriForce.
Switch power on and off with the toggle switch, found in the base of the unit.
07-00274K F211, F211-AK, F211-BU 3 Dri-Eaz Products, Inc.
2. Set up the remaining FIVE manifolds with the follow­ing lengths of tubing:
To install the tubing, slide the one end of the tubing over the manifold outlet nipple and insert an injector in the other end.
Tightly seal off the last manifold on each run of ADS with an end-cap plug. Now place the injectors into the holes you have drilled or punched in the wall, cabinet or other assem­bly.
SPECIFICATIONS
DriForce InterAir Drying System (F211)
BASE UNIT
Dimensions (H × L × D)
14 × 14 × 12 in. | 35 × 35 × 30 cm
Amperage
5.4 amps
Power
115V / 60Hz
Total system airflow (max.)
100 CFM | 2.3 CMM
Working static pressure (water lift)
38 in. | 97 cm
Weight (base unit only)
14.5 lbs. | 6.3 kg
Safety
ETL listed to UL 507 and CSA C22.2 No. 113
AIR DELIVERY SYSTEM (ADS)
Crush-proof ADS tubing
91 ft. (28 m).of 1½ in. (3.8 cm) tubing. Pre-cut into thirteen 7 ft. (2 m) sections.
Injector hole size
Less than ¼ in. (6 mm)
Flexible tubing
400 ft. (122 m) of in. (0.375 mm) ID tubing
Carrying/storage system
2 suitcase-style duffle bags with handle and wheels
Drying modes
Either positive or negative pressure
Parts included
100 injectors, 8 manifolds (12 outlets each), 4 manifold endcaps, 4 coupler fittings, 2 hose clamps, 2 T-fittings, 13 hose assemblies with cuffs, 25 tube extender connections, 1 muffler.
Ensure that all T-fittings, hose cuffs, manifolds, supply lines, and injectors are properly installed. Attach the ADS to the DriForce. Plug in the DriForce and switch it on briefly, checking all connections for air leakage. If needed, use a hose clamp to seal off any air leakage where the vinyl prod­ucts connect up to hose barbs, etc.
Drying Procedure
Phase 1: Air Extraction (Vacuum) Drying
Attach the ADS to the vacuum inlet of the DriForce blower unit and switch unit on.
Use the air extraction (vacuum) mode to draw humid air from structural cavities.
Operate Phase 1 until the humidity of the air being drawn from the affected area is approximately the same as the humidity in an unaffected area of the job. You can use a hygrometer to compare RH readings between the outlet of the DriForce and the surrounding area.
NOTE: Be sure to attach the vacuum hose to the DriForce outlet and direct the exhaust air outside the structure. Do not use the muffler-filter that is supplied with the DriForce in the air extraction mode. This filter is not a HEPA-grade fil­ter, and will not properly capture contaminants that may be drawn into the DriForce. Use the muffler-filter only in the in­jection (blower) mode, described below.
Phase 2: Air Injection (Blower) Drying
Attach the ADS from the vacuum to the pressure outlet of the DriForce, install the muffler-filter on the air in­take, and switch unit on.
Once the humidity inside the structural cavity equals the humidity in the room, it is time to switch to the air injection mode. Injecting room air into the structural cavities will help continue the drying process. This is especially true if you are dehumidifying the room air.
TIP: When drying inside walls, use an awl-punch or drill to create a small vent holes placed just above the highest moisture point on the wall. This will provide a vent and help to speed up the drying process by allowing greater air flow through the affected materials. A small hole can be easily patched.
TIP: To maximize drying in walls that wainscoted, tile-cov­ered, double-sheeted, or covered with vinyl wall paper or impermeable paint, as well as lath and plaster walls, fire­walls and insulated walls, place additional injectors per lin­ear foot.
TIP: Accelerate drying with dehumidifiers. To increase drying rates during Phase 2, use a dehumidifier to supply dry air directly into the DriForce. Position the dry air outlet of a dehumidifier near the DriForce air inlet, or duct the de­humidifier outlet toward the DriForce inlet. Desiccant de- humidifiers are especially useful for this purpose, as the extremely dry air they produce can accelerate the dry­ing of dense materials and assemblies.
NOTICE: Do NOT tape or seal the dehumidifier ducting to the DriForce inlet, as this could unbalance the airflow through the dehumidifier and possibly damage the dehu­midifier.
Odor and Mold Control
If you suspect that mold and mildew may be growing inside
cavities, follow the appropriate industry mold remediation procedures and safety standards.
MAINTENANCE
WARNING: Always unplug unit prior to servicing or cleaning.
As needed
Check both the inlet and outlet of the DriForce unit for obstructions or debris after each use.
Inspect the muffler-filter, and clean as needed by vacuuming or washing. Check manifolds, tubing, injectors and other ADS components, and replace if needed.
Clean the exterior of the DriForce and ADS components with a vinyl cleaner and protectant.
Parts, service, and maintenance and warranty information are available from your Dri-Eaz distributor.
07-00274K F211, F211-AK, F211-BU 4 Dri-Eaz Products, Inc.
MANUAL DEL USUARIO
Colectores (× 8)
Conectores de mangueras (× 5)
Manguera a
pies / 2 m).
Bolsos para
Silenciador / fil­tro DriForce
Unidad DriForce
Conectores T
(× 2)
Tubería ADS Inyectores (×
Tapas del colec­tor (× 4)
COMPONENTES DEL SISTEMA DE SECADO POR AIRE (ADS) DRIFORCE
ADVERTENCIA
DriForce™ InterAir Sistema de Secado
Modelo F211, F211-AK, F211-BU
DRI-EAZ PRODUCTS, INC.
Teléfono: 800-932-3030 Fax: 360-757-7950 LegendBrandsRestoration.com
El InterAir Sistema de Secado de DriForce permite al reparador dirigir aire a alta presión contra paredes húmedas, detrás de los gabinetes y sobre otras estructuras difíciles de alcanzar, con un mínimo efecto sobre los materiales. Permite un secado rápido y eficaz en todo tipo de montajes y materiales.
Patentes: www.LBpatents.com
LEA Y C O N S E R V E E S T A S I N S T R U C C I O N E S
¡ADVERTENCIA! Para reducir el riesgo de incendio o descarga eléctrica, no use este ventilador con ningún dis­positivo de control de velocidad sólido.
¡ADVERTENCIA! La unidad debe tener puesta a tierra. No utilizar con un cable de extensión. Conectar solamente a un toma provisto de un dispositivo de interrupción por fallo con puesta a tierra.
(91 pies)
¡ADVERTENCIA! No toque las parrillas cuando la unidad esté en funcionamiento.
AVISO: Mantener seco el motor. Sólo para uso interior. AVISO: Desenchufar cuando no esté en uso o cuando esté
desplazando la unidad. ADVERTENCIA: No permita que los niños jueguen con o
cerca de la unidad. Asegúrese de que la unidad no quede accesible a los niños cuando no se la esté controlando.
AVISO: Siempre operar la unidad sobre superficie estable y nivelada para que no pueda caerse y causar lesiones.
¡ADVERTENCIA! No modificar su producto Dri-Eaz. Utilice sólo repuestos autorizados por Dri-Eaz Products, Inc. Las modifica­ciones o el uso de piezas no autorizadas podrían provocar un accidente y la nulidad de la garantía. Póngase en contacto con su distribuidor autorizado de Dri-Eaz para obtener ayuda.
llevar (× 2)
del colector
07-00274K F211, F211-AK, F211-BU 5 Dri-Eaz Products, Inc.
prueba de aplastamiento (13 tramos de 7
Loading...
+ 9 hidden pages