The DrizAir® 1200 dehumidifier reduces humidity in enclosed structural environments by
removing water vapor from the air. The 1200 is engineered to be rugged, durable and highly
portable, making them ideally suited for water damage restoration, structural drying,
construction, and other applications requiring temporary, high-performance
dehumidification.
READ AND SAVE THESE INSTRUCTIONS
SAFETY INSTRUCTIONS
WARNING! Electric shock hazard, rotatin g fan, hot
surface hazards. Unplug unit before open ing cover
for cleaning or servicing. Unit must be grounded.
• Inspect the power cord before use. If cord is
damaged, do not use. Always grasp the plug (not
the cord) to unplug.
• Insert three-prong plug on power cord into a
matching electrically grounded outlet. Do not use
adapter. Never cut off third prong. Do not use an
extension cord.
• The unit must be operated on a 115V/60 Hz circuit
protected by a Ground Fault Circuit Interrupter
(GFCI) device.
• Keep motor and wiring dry.
• Do not attempt to repair the unit. Contact your local
authorized distributor for service.
BEFORE YOU BEGIN
Unpacking your unit
Retain all packing material and boxes for possible
equipment returns.
Install the handle
The 1200 is shipped without the handle attached. Install
the handle using the four ¼-20 hex washer-head bolts
supplied and a ⅜ in driver or wrench. Make sure the
bolts are firmly secured before using the unit. Do not
overtighten.
Warranty registration
Visit warranty.drieaz.com to register your purchase.
Registration allows us to better assist you with using,
maintaining or servicing your equipment, as well as to
contact you in case we have important safety information
concerning your Dri-Eaz product. If you deter mine
service is required, have your equipment model, serial
number and original proof of purchase available and call
your distributor for assistance with obtaining a return
material authorization (RMA).
INTRODUCTION
Dehumidifiers reduce humidity in enclosed structural
environments by removing water vapor from the air. With
proper use, the 1200 can help dry carpet, carpet pad,
floors, walls, building contents and more. Using
dehumidifiers can also help prevent secondary damage
caused by high humidity. For best results, use the 1200
with Dri-Eaz TurboDryer
perimeter of the room to distribute heat energy and
release moisture from wet surfaces into the air.
®
airmovers placed around the
How the 1200 dehumidifier works
Dri-Eaz refrigerant dehumidifiers operate by pulling
moist air in across a very cold evaporator core. The
moisture in the air condenses on the coil. In certain
conditions, the machine operates in defrost mode,
warming any frost accumulated on the evaporator coil
back into water. T he water c ollects in a tra y and is
pumped out through a hose.
IMPORTANT: Before moving the unit, make sure there’s
no water in the pump. See how to use the PURGE
function under “How to use the control pad” on page 2
.
07-01705B 2014-04 Warranty 07-00420 1 Dri-Eaz Products, Inc.
POSITIONING A DEHUMIDIFIER
Control panel.
Molded indent
Humid air
Process (dehumidified)
air outlet (not shown).
FIG. A: FRONT
For best results, operate your dehumidifiers in an
enclosed area, as this creates a drying chamber. Close
all doors and windows that open to the outside to
maximize the unit’s water removal efficiency. Also, keep
traffic though the drying chamber to a minimum. Place
your 1200 dehumidifier against a wall, away from
obstructions, and keep it away from anything that could
block airflow into and out of the unit.
Managing temperature rise
before operating it. When the unit is placed in a
horizontal, oil from the compressor flows into the
refrigerant coils reducing the ability of the dehumidifier to
function.
Set up drain hose
The 1200 condensate pump connects to a plastic
drainage hose that is wrapped around the air outlet
located at the back of the unit. This hose is equipped
with a quick-connect fitting for quick attachment to the
provided 40 ft. drain hose. Unwrap the entire hose and
place the unattached end in a sink, drain, bucket or
outside – anywhere that water can drain out safely. If
you use a bucket or other receptacle for water collection,
check it regularly to prevent spills.
for cord storage.
inlet. Air filter
located behind
screen.
DrizAir dehumidifiers warm the air as they remove
moisture. Optimal drying temperatures range from
68−85°F (20−29°C).
The most accurate way to monitor temperature is with a
thermo-hygrometer; however, you can use an
indoor/outdoor thermometer to gauge temperature. Just
make sure it is located in the center of the room away
from the airflow of the dehumidifier.
If the temperature rises to unsafe levels (over
90°F/32°C) you can use the structure’s HVAC (heating
air conditioning) system to bring the temperature down.
Just set it to 80°F (27°C), and continue to operate the
dehumidifier. For more information about creating an
optimum drying environment, visit
www.Dri-Eaz.com.
NOTE: Uncoil and straighten the entire drain hose.
Do not leave any of part of the hose coiled on the
unit and do not place the end of the hose higher
than 20 ft. (6 m) above the top of the unit. Also
check for kinks, or obstructions that would restrict
the flow of water. Failure to do so may cause a water
backup in the pump resulting in leakage.
Plug in electrical cord
Locate the electrical cord either on the top or back of the
unit. The 1200 dehumidifier may be plugged in to a 115volt (15 amp) grounded outlet, which is standard in most
homes.
If the unit experiences a loss of power, either from a
power interruption or from thermal overload protection,
let the unit rest for five minutes before restarting.
Otherwise it might shut off again.
Turn the unit on
Press the “on” button on the touchpad.
How to use the control panel
The Touchpad on DrizAir dehumidifiers has one display
and four keys. The normal display messages are
OPERATING YOUR DEHUMIDIFIER
Set unit upright
Always operate the dehumidifier in an upright position. If
the unit has been stored or transported in a horizontal
position, set it upright (vertical) for at least 30 minutes
07-01705B 2014-04 Warranty 07-00420 2 Dri-Eaz Products, Inc.
Drip tray
Coils
Pump
FIG. B: CLEANING
DEHUMIDIFIER OFF CMPRSR DELAY
DEHUMIDIFIER ON PUMP PURGING
TOTAL HRS DEFROST ON
JOB HRS GET SERVICE ERXX
When the unit is first connected to AC power, the
touchpad display will cycle continuously through three
messages: DEHUMIDIFER OFF, TOTAL HOURS, and
JOB HOURS.
ON-OFF. Press the ON-OFF key to turn the unit on
or off. When turning the machine on, usually the display
reads CMPRSR DELAY and performs a numeral count
down from a maximum of 60 seconds to 0. The
compressor delay gives the machine time to warm up
(when needed). If you don’t see a compressor delay
countdown, the machine is ready to go. Once the unit
completes the CMPRSR DELAY, the display reads
DEHUMIDIFIER ON, and continues to cycle between
TOTAL HOURS, JOB HOURS and DEHUMIDIFIER ON.
Press the ON-OFF key again to turn the unit off. The
display will read DEHUMIDIFIER OFF.
DISPLAY. Press the DISPLAY key to stop the
display at DEHUMIDIFER ON or OFF, TOTAL HOURS,
or JOB HOURS as it cycles. Press DISPLAY again to restart the display cycle.
How to change the language display
CAUTION: While in the change-language mode,
pressing other keys can change the programming of the
machine. Do NOT press other keys you’re not instructed
to press.
Use the DISPLAY key to change the display language.
Follow these steps:
1. Unplug the unit.
2. While holding down the
DISPLAY key, plug the unit in.
The display reads ENGLISH.
3. To change to FRANCAIS,
DEUTSCH, or ESPANOL, press
the DISPLAY key or the CLEAR
key.
4. When the desired language
is shown in the display, unplug
the unit, and the language is
set.
CLEAR. Press the CLEAR
key to reset the JOB HOURS
1. As the display cycles
between DEHUMIDIFIER ON,
JOB HOURS, and TOTAL
HOURS, press the DISPLAY key when JOB HOURS
appears on the screen. That will make the display read
JOB HOURS steadily.
2. Then press the CLEAR key to re-set the numerals
to 00000.
3. Press DISPLAY again to re-start the display cycle.
NOTE: the TOTAL HOURS reading cannot be re-set.
PURGE. Press the PURGE key to empty water
from the pump reservoir. During normal operation, the
pump purges automatically every six minutes, or
whenever the reservoir is full. The display will read
PUMP PURGING with a num eral countdo wn. To purge
the pump manually:
1. Turn the power off using the OFF key, and let the unit
sit plugged in for about 10 minutes. This allows water to
drip from the coils and collect in the drip pan.
2. Press PURGE to remove residual water.
Defrost mode
During normal operation, the temperature sensor detects
frost forming on the coils, causing a defrost cycle to
start. The display will read DEFROST ON.
Dehumidification stops during the defrost cycle. When
the unit completes the cycle, the display returns to
DEHUMIDIFIER ON.
Error messages
If the 1200’s onboard diagnostics discover a problem,
the unit will disp lay “GET SERVICE,” followed by "ER”
and a numeral from 01 to 09. If this message appears,
first follow these steps:
1. Unplug the unit and then plug it back in. This may reset the electronics.
2. If the error message reappears, try the solution (if one
is listed) in the “Error Messages,” p. 4.
3. If the error message still
appears, please contact the Dri-Eaz
Service Department at
888-867-3235.
At the end of the job
As with all dehumidifiers, once the
drying job is completed, it is
important to make sure the unit is
completely purged of water before
moving it. To ensure that all water
has drained into the pump, turn
the unit off, allow it to rest for 10
minutes, then press the PURGE
button. (The unit must be plugged
in for the purge to operate.) Once
the purge cycle is complete, unplug
the unit and remove it promptly
from the job.
Before transporting, be sure to
07-01705B 2014-04 Warranty 07-00420 3 Dri-Eaz Products, Inc.
remove the external drain hose, drain it carefully, and
MESSAGE
return it to the pocket provided on the front of the unit.
MAINTENANCE
WARNING! ELECTRIC SHOCK HAZARD. Unplug the
1200 before performing any maintenance.
1. Unplug unit.
2. Remove housing, locate coils and allow coils to dry if
wet.
3. Vacuum both sides of the coils until clean, being
careful not to let the nozzle touch the fins; as that may
cause damage by bending them.
Before each use
Inspect the electrical cord for damage. Look for
fraying, cuts, etc. Do not use the unit if you find any
damage. Contact your local authorized distributor for
service.
Inspect and vacuum filter as needed. Keep a clean
filter in the unit at all times to protect internal
components from dust and other particulate build-up.
The 1200 is equipped with a 3M™ High Air-Flow filter.
The HAF filter may be vacuumed clean and reused up to
three times. Do not rinse or wash the HAF filter, as it
will reduce the effectiveness of the electrostatic material.
Replace only with a new 3M HAF Filter (Dri-Eaz part no.
F368). Contact your local authorized distributor for parts.
CAUTION: Dust can cause the unit to overheat and
shut down. Do not operate when excessive dust or
airborne particles are present, such as during
sanding or spray-painting. Inspect and clean air filter
elements and coils frequently.
IMPORTANT: Replace the HAF filter whenever 1)
it has been vacuumed clean 3 times or 2) it has
been used on a mold remediation job or
otherwise exposed to potentially dangerous
contaminants.
Monthly
Check coils. Dirty coils can cause the unit to overheat.
Clean when visibly dirty. See Fig. B.
Check catch basin tray. Clean when dirt and debris are
present.
1. Wipe clean with a rag.
Check drain hose.
1. Look for obstructions. Disconnect and clear any debris
present.
2. Reattach drain hose.
Annually
Have the pump system inspected by your local
authorized distributor .
TRANSPORT AND STORAGE
NOTICE: Handle the unit carefully. Do not drop, throw,
or place the unit where it could fall. Rough treatment can
damage this equipment and may create a hazardous
condition or void warrant y.
IMPORTANT: Be sure to purge the water from the pump
reservoir before moving the unit. See the PURGE
function under "How to use the control panel" on page 2.
Note that the unit must be plugged in for the Purge
function to operate.
1. Do not expose the control panel to moisture, snow or
rain when transporting in uncovered vehicles.
2. Store and transport securely to avoid any damaging
impact to internal parts.
READ AND SAVE
THESE INSTR
ERROR MESSAGES
The table below shows error message that the system may detect. If the display shows an “ER” message, first unplug the
unit and then plug it back in. This may re-set the electronics, and if so, no further action is required. If the error message
reappears, try the solution shown under “Explanation.” If this still does not fix the problem, Contact your local authorized
distributor.
ERROR
ER 1, 2, 3, 5, 6 Problem with electronic control panel. Contact Dri-Eaz Service.
ER 4 Check the temperature or sensor cable. Contact Dri-Eaz Service for instructions.
ER 8 Check the touchpad key. Press and release each key several times.
ER 9 Check for obstructions or kinks in the drain hose.
EXPLANATION
TROUBLESHOOTING
07-01705B 2014-04 Warranty 07-00420 4 Dri-Eaz Products, Inc.
Unit
Room temperature too low
Increase room temperature.
Pump does not
Stuck float valve
Clean float valve shaft.
Dimensions
(H × D × W)
32 × 20 × 19.5 in.
83 × 50 × 50 cm
Water removal AHAM
(80°F/60% RH)
Water removal max.
(90°F/90% RH)
FAULT CAUSE SOLUTION
Unit does not
operate
Unit operating,
but room not dry
No power to machine.
Unit not switched on.
Not enough time to dry.
Poor air movement in room.
Excessive moist air infiltration.
Plug in unit; check power at outlet and at base of unit.
Switch unit on.
Allow more time for drying.
Increase air movement with air movers.
Reduce infiltration.
continuously in
defrost mode
function
Unit collects too
little water
Room air is dry.
Room temperature is too low.
Check humidity with hygrometer.
Increase room temperature.
Check filter and coils; clean as necessary.
If the problem you are experiencing is not listed here, call your local distributor or contact the Dri-Eaz Service
Department toll-free at 800-932-3030.
SPECIFICATIONS
Model DrizAir 1200 F203-A
Type Standard refrigerant
Refrigerant R-410A
Use weight 80 lbs. | 36 kg
Power 6.4 amps, 115 volts
64 pts. | 30 liter s / day
132.3 pts. | 62.6 liters / day
Max process ai r 235 CFM | 400 CMH*
Operating range 33°–100°F | 1°–38°C
Air filter 3M HAF filter (part no. F368)
Power cord 25 ft. | 7.6 m
Construction
Safety
Specifications are subject to change without notice. Some
El deshumidificador DrizAir® 1200 reduce la humedad en ambientes cerrados eliminando el
vapor de agua que se encuentra en el aire. El modelo 1200 está creado de modo que sea
resistente, duradero y fácil de transportar, características que lo convierten en un elemento
sumamente adecuado para la reparación de daños causados por el agua, el secado de
estructuras, la construcción y otros usos para los que se necesita temporalmente un
deshumidificador de alto rendimiento.
LEAYGUARDEESTASINSTRUCCIONES
INSTRUCCIONES DE SEGURIDAD
¡ADVERTENCIA! Peligro de sufrir una descarg a
eléctrica, lastimarse con el ventilador rotatorio,
quemarse con una superficie caliente. Desenchufe la
unidad antes de abrir la tapa para li m piarla o
repararla. La unidad debe tener descarga a tierra.
• Controle el cable de alimentación antes de usar. Si
está dañado, no lo use. Para desenchufar el
aparato, tire siempre del enchufe (nunca del cable).
•Coloque el enchufe de tres clavijas que está en el
extremo del cable de alimentación en un
tomacorriente con descarga a tierra adecuado. No
use adaptadores. Nunca corte la tercera clavija. No
use cables prolongadores.
•La unidad debe utilizarse en un circuito eléctrico de
115 V/60 Hz, protegido por un interruptor del circuito
de fallos de conexión a tierra (GFCI, por sus siglas
en inglés).
• Mantenga el motor y los cables secos.
• No intente reparar la unidad.
ANTES DE COMENZAR
Cómo desembalar la unidad
Conserve todo el material de embalaje y las cajas por si
tiene que devolver el equip o.
Cómo colocar la manija
La manija del modelo 1200 no viene acoplada. Para
colocarla, use los cuatro tornillos con arandela y cabeza
hexagonal de ¼-20 que acompañan al equipo y un
destornillador o una llave de tuercas de ⅜ pulgadas
(9.5 mm). Antes de usar la unidad, asegúrese de que los
tornillos estén bien ajustados.
Registro de la garantía
Visite warranty.drieaz.com para registrar su compra. El
registro nos permite brindarle mejor asistencia en el uso,
el mantenimiento o la reparación de su equipo, y
también comunicarnos con usted en caso de que
tengamos información de seguridad importante sobre su
producto de Dri-Eaz. Si considera que su producto
necesita reparación, tenga a mano el modelo del equipo,
el número de serie y el comprobante de compra original,
y llame a su distribuidor para que lo ayude a obtener
una autorización para devolver el producto (RMA, por
sus siglas en inglés).
INTRODUCCIÓN
Los deshumidificadores reducen la humedad en
ambientes cerrados eliminando el vapor de agua que se
encuentra en el aire. Si se usa correctamente, el 1200
puede ayudar a secar alfombras, almohadillas para
alfombras, pisos, paredes, elementos en el interior de
una propiedad y más. También puede ayudar a prevenir
daños secundarios causados por el exceso de
humedad. Para obtener mejores resultados, cuando use
los deshumidificadores 1200 coloque ventiladores
TurboDryer
habitación, a fin de distribuir la energía térmica y hacer
que la humedad de las superficies mojadas se pierda en
el aire.
®
de Dri-Eaz alrededor del perímetro de la
07-01705B 2014-04 Warranty 07-00420 6 Dri-Eaz Products, Inc.