OPERA TING MANUAL - HP4-X 400-750 FM DR YERS
Revision 10/8/02
Page 1
DRI-AIRINDUSTRIES, INC.
Page 2
DRI-AIRINDUSTRIES, INC.
16 THOMPSON ROAD
P.O. BOX 1020
EAST WINDSOR, CT 06088-1020
Tel. (860) 627-5110
FAX(860) 623-4477
Internet http://www.dri-air.com
e-mail: sales@dri-air.com
OPERA TING MANUAL - HP4-X 400-750 FM DRYERS
Revision 10/8/02
DRI-AIRINDUSTRIES, INC.
CONTENTS
DRYER OPERA TION/FEATURES---------------------------4
AIR FLOW SCHEMATIC FOR HP4-X DRYER -----------6
DRYER CYCLE DIAGRAM------------------------------------ 7
INST ALLATION PROCEDURE ------------------------------- 8
Electrical Connection ---------------------------------------8
Check for correct motor rotation -------------------------8
Compressed Air Connection------------------------------8
Set Temperature: -------------------------------------------- 9
DRYER OPERATION-TROUBLE SHOOTING --------- 10
DRYER OPERA TION-DETAILED DIAGNOSIS -------- 11
DRI-AIR ZONE V ALVE --------------------------------------- 12
PARTS LIST----------------------------------------------------- 13
OPERA TING MANUAL - HP4-X 400-750 FM DR YERS
Revision 10/8/02
Page 3
DRI-AIRINDUSTRIES, INC.
DRYER OPERATION/
FEATURES
The HP4-X 400/500/750 dryer series is a four bed dryer
design that is ideal for use on large molding press or extrusion
applications. This large capacity dryer combines our patented
desiccant tower design and state of the art microprocessor
controls to provide a constant supply of dry air to the material
hopper. Material drying is controlled by utilizing one zone for
removing moisture from the process air, while regenerating
the other by heating the desiccant to a high temperature.
Once the regenerated beds cool down, the Zone V alve
switches the airflow, and the newly regenerated beds are used
to desiccate the process air stream. The saturated beds are
now regenerated in the same manner, completing the
regeneration cycle. The cycle is depicted Page 7.
The airflow design of the HP4-X dryers makes the
regeneration cycle more efficient because we utilize a small
amount of the desiccated process air rather than ambient air
to regenerate the desiccant bed. This reduces the impact of
the high moisture content of the ambient air, which would
contaminate the desiccant bed, and allows the dryer to attain
a lower dew point. Please see the Air Flow Schematic on
Page 6.
HP4-X Design
Our patented HP4-X design incorporates 4 double-stacked
desiccant beds . This nearly doubles the amount of desiccant
available for drying the process air stream, and because of the
tower design, the dryer is able to regenerate the desiccant in
the same time as our ARID-X series. This allows the dryer to
operate in very high humidity conditions without affecting the
process air dew point. In fact, this design produces dew point
levels of – 40’ to -80’ C for faster more complete drying of your
material.
Unique to the HP4-X 400/500/750 disiccant bed design is the
use of two sets of desiccant towers per zone. The first tower
in each Zone Set is the regeneration cycle “control tower”,
while the second tower of the Zone Set is “slaved” off the first.
Please see the Air Flow Diagram on Page 7.
Hopper Design
These dryers are designed to be used with our large capacity
1000, 1500, and 2000 lb. hoppers. Dri-Air’s ”all stainless”
hopper design utilizes a stainless steel inner shell surrounded
by a stainless steel jacketed insulation layer. The easily
removable stainless steel spreader cone promotes proper
Page 4
OPERA TING MANUAL - HP4-X 400-750 FM DRYERS
Revision 10/8/02
DRI-AIRINDUSTRIES, INC.
DRYER OPERATION/
FEATURES (Cont.)
material flow to ensure that the material is dried efficiently and
no undried material is left at the hopper bottom that needs to
be fed out prior to operating. Y ou must ensure that your
hopper is adequately sized for your usage rate and is kept
filled, to ensure that you have sufficient time to dry the
material.
Dryer Controls
The HP4-X series is supplied with the advanced
Microprocessor Control Module. The module includes a
mother board, display board and key pad that allow the
operator to easily monitor dryer performance and input
operational settings.
The Microprocessor Control Module is one of the most
sophisticated yet operator friendly controls on the market. It
has many more features than other PLC and Microprocessor
controls currently available. This module provides the
operator with more control and operational flexibility with the
dryer. These features and the operating instructions are
covered in detail in the Microprocessor Control Instruction
Manual included with your dryer.
OPERA TING MANUAL - HP4-X 400-750 FM DR YERS
Revision 10/8/02
Page 5
DRI-AIRINDUSTRIES, INC.
P
0
AIR FLOW SCHEMATIC FOR ARID-X 400/5
ZONE 2
ELECTRICAL BO
X
ZONE 1
PLAN VIEW
T/C
SECONDARY
HEATER
T/C
BLOWER
FILTER
ZONE VALVEZONE VALVE
VENT
VENT
FROM
MATERIAL
HOPPER
T/C
SECONDARY
HEATER
T/C
REGENERATION
AND PROCESS
HEATER
Page 6
REGENERATION
AND PROCESS
HEATER
SAFETY
THERMAL
PROCESS HEATER
SAFETY
THERMAL
SAFETY THERMAL
TO MATERIAL HOP
OPERA TING MANUAL - HP4-X 400-750 FM DRYERS
Revision 10/8/02
DRI-AIRINDUSTRIES, INC.
OPERATING MANUAL - HP4-X 400-750 FM DR YERS
Revision 10/8/02
Page 7
Dryer Cycle
Diagram
D esicant Beds
Zo ne 1 H e a ti ng
Zone 2 C o o ling
Zo ne 2 H e a ti ng
Zone 1 C o o ling
Valve Shif t s
Valv e Sh if t s
DRYER CYCLE
DIAGRAM
XX
DRI-AIRINDUSTRIES, INC.
INSTALLATION
PROCEDURE
For all Dri-Air models except ARID-X 10, AHM-1, & PDII
Electrical Connection:
Open electrical access door on the front of the machine by
turning the disconnect off and turning the lower clamping
screw 1/2 turn counterclockwise. Locate the disconnect by
following the operating handle down to the electrical panel.
Insert the incoming power cable or conduit through the hole
provided on the side of the machine.
« use approved wire and fastening means «
Wire incoming power to the top of the disconnect as shown in
the diagrams below.
208/230 1PH 50/60 HZ380/415 3PH 4W 50HZ *
L1 L2 L3
NOTE:
When 3 wire supplies are used in place of 4 wire supplies,
a control transformer is required.
GND MP R S T
XX
3 PHASE DRYER INST ALLATION
CHECK FOR CORRECT MOTOR ROTATION
BEFORE RUNNING DRYER
To check blower motor rotation.......
Remove the front panel of the blower compartment so the
blower can be observed. Turn on the power to the dryer and
press the ST ART touch pad on the dryer’s control panel and
quickly press the STOP touch pad. Observe the cooling fan on
the motor. The motor should rotate in a “clockwise” direction.
If the motor is rotating counterclockwise, switch any two
adjacent supply wires.
Compressed Air Connection:
Compressed air is required for the HP4-X 400/500/750 Floor
Mount models to operate the dryer’s Zone V alve. For those
units:
CONNECT COMPRESSED AIR TO INLET ON DRYER SIDE
P ANEL. Maximum incoming pressure not to exceed 100 psi
(.69 MPa). The pressure gauge on the dryer is factory set to
70 psi.
The unit is now ready for operation.
Page 8
OPERA TING MANUAL - HP4-X 400-750 FM DRYERS
Revision 10/8/02
DRI-AIRINDUSTRIES, INC.
START-UP PROCEDURE
Turn disconnect on electrical panel to ON position and follow
the instructions below:
Microprocessor Control Panel
1. Power light indicates there is power on.
2. After initializing, dri air will be displayed.
3. Press
4. To set the process air temperature:
5. Left display indicates actual temperature
6. Right display shows dewpoint or set temp
7. To set high temp alarm: (degrees over setting)
8. Status block indicates heater on or fault
9. See Microprocessor manual for setting 7-day timer .
10. Configuration of the dryer parameters is done
STAR T to start the dryer.
Press SET - right display shows set temp.
Change setting using arrow keys.
Press ENTER to input new setting.
Press TEMP to display process air set temp.
Press D.POINT to display dew point.
Press ALARM - right display shows setting.
Change setting using arrow keys.
Press ENTER to input new setting.
using the setup button. See Microprocessor Control
manual.
OPERA TING MANUAL - HP4-X 400-750 FM DR YERS
Revision 10/8/02
These instructions are covered in detail in Microprocessor
Control Instruction Manual. Please read this manual before
proceeding further.
Page 9
DRYER OPERATION &
BASIC
TROUBLESHOOTING
DRI-AIRINDUSTRIES, INC.
Operating the Dryer
Our dryers are capable of operating in heavy industrial to
clean room environments with no significant loss in
performance. In order to maintain this high level of
performance, the operator should take the following steps:
Hopper Maintenance/Material Control
1. In order to ensure that material is sufficiently dried;
a. The material hopper should be kept filled to a constant,
predetermined level to allow sufficient dwell time in the
hopper to dry the material
b. To ensure proper air flow through the hopper , always
keep the level of material above the spreader cone on
the diffuser basket, ensuring that it is completely
covered.
c. Routinely clean the hopper and diffuser basket by
removing the spreader cone assembly and blowing the
basket and hopper out with compressed air.
d. Do not overfill the hopper, blocking the exhaust port at the
top.
Filter Maintenance
1. Routinely remove and clean the filter element by blowing it
out with compressed air. DO NOT OPERATE DRYER
WITHOUT FILTER ELEMENT INSTALLED.
Page 10
OPERA TING MANUAL - HP4-X 400-750 FM DRYERS
Revision 10/8/02
DRI-AIRINDUSTRIES, INC.
Basic Trouble-Shooting
The new Dri-Air MICROPROCESSOR Electrics are designed
for quick diagnosis of problems. The microprocessor is
designed to display error codes and faults that indicate the
nature of the failure that has occurred. The most common
errors and faults are discussed in the Microprocessor Control
Instruction Manual and should be consulted in the event of a
failure.
The following steps should be taken before proceeding with
other diagnostic steps.
1. Check the Power Circuit:
a. Incoming power fuses or circuit breaker
b. Check all dryer fuses with multimeter.
c. Is power supplied to the unit?
d. Check heater continuity using a volt/ohmmeter.
2. Compressed Air:
a. Is compressed air connected with at least 70 PSI
b. Check water separator and drain if necessary
c. Pressure gauge should read 70 PSI
3. Air Flow Circuit:
a. Ensure Zone Valve position corresponds to the
regeneration cycle by comparing the position of the Zone
V alve to the ZONE position lights on the dryer control
panel (See pg. 12 for details).
b. Make sure that all process air hoses are connected, not
crushed, and free from obstructions.
c. Inspect filter and make sure cover is tight and the filter
element is clean.
4. Control Circuit:
a. Using the MICRO Display panel ZONE indicator
lights as a guide for the dryer regeneration cycle, check
that all outputs to heaters are proper for the part of the
regeneration cycle that the machine is in. (Output
voltage to heater relays is approx 4.5v)
5. Operating Conditions:
a. Check the process temperature. It should
below 140° F (60° C) because the unit will go into high
temp alarm.
not be set
OPERA TING MANUAL - HP4-X 400-750 FM DR YERS
Revision 10/8/02
Page 11
DETAILED DIAGNOSIS &
TROUBLESHOOTING
DRI-AIRINDUSTRIES, INC.
Diagnosing problems with the dryer is very easy , as the
Microprocessor Control Module performs numerous internal
diagnostic checks upon start-up and continually monitors
critical parameters during operation. When a fault or failure is
detected, the dryer shuts down and an Error Code is displayed
on the dryer’s control panel.
Error codes are displayed on the control panel by Err
appearing in the left display and a three digit number
appearing in the right display . Each code corresponds to a
specific type of failure. These codes are discussed in detail in
the Microprocessor Control Instruction Manual.
If the temp will not reach set point, check the following:
1. Check heater fuses with multimeter.
2. Check blower rotation by utilizing procedure detailed on
page 8 of Installation Procedures.
3. Check location of process air thermocouple. Ensure
that is positioned so that the tip is centered in the inlet
port to the hopper.
4. Check dryer’s internal air flow by the following:
a. Ensure that Zone V alve Air Diversion Valve is
positioned correctly .
b. Ensure filter element is not blocked or choked
with dust/material.
c. Ensure air flow to hopper is sufficient by
removing process air hose from dryer and
checking flow from dryer.
If the temp exceeds the set point, check the following:
1. Remove the hose from the top of the hopper to check air
flow. There should be air flow out of the hopper with a
suction on the hose. If there is little or no flow, check the
inlet hose.
2. Inspect the filter to make sure that it is clean and not
affecting the air flow .
3. Check to see if heater relay has failed on. Using an
ammeter or voltmeter, check the output lead from the
relay to the heater for power to the heater when the
Micro Display LED for that heater is off.
4. Check the Zone Valve position.
Page 12
OPERA TING MANUAL - HP4-X 400-750 FM DRYERS
Revision 10/8/02
DRI-AIRINDUSTRIES, INC.
DRI-AIR
ZONE VALVE
TROUBLESHOOTING
The Dri-Air Zone Valve assembly is designed to provide very
little flow restriction and no leakage. To direct the air flow for
the regeneration cycle and process air, the assembly
incorporates pneumatic Air-Flow Diversion V alves and
Regeneration Air Exhaust V alves controlled by a single
solenoid valve.
TROUBLESHOOTING is easy . The Air-Flow Diversion Valve
assembly located on the top of the dryer cabinet is equipped
with viewing ports to observe the assembly’s operation. To
check the valve, note which zone is in regeneration by
observing the REGEN indicator LED on Microprocessor
Control Panel and then checking that the corresponding Air
Diversion Cylinder has actuated, closing the port to the
towers. The Regeneration Air Exhaust Valves located in the
dryer blower compartment, work in tandem with the Air-Flow
Diversion Valves, by opening when the Diversion Valve is
closed, to allow the wet regeneration air to exhaust. To check
these valves, simply check to see if air is exhausting out the
bottom of the dryer. If the valves are not working properly
check the following:
1. Check all air line connections to make sure they are
tight.
2. Check air lines to ensure they are not cracked or
broken.
3. Check incoming air pressure (70 psi min.).
4. Check operation of solenoid valve (See below).
To check operation of solenoid valve, remove front
panel to blower compartment. The valve is located
on the right-hand wall, directly connected to the air
pressure regulator. Located on the top of the valve
is a button, that when depressed will actuate the
valve. With air pressure supplied to the dryer, use
a small screw driver to depress the actuator
button. Observe the action of the Air Diversion
V alves on the top of the dryer. If the Diversion
V alves operate, the solenoid valve is operating
correctly.
OPERA TING MANUAL - HP4-X 400-750 FM DR YERS
Revision 10/8/02
Page 13
DRI-AIRINDUSTRIES, INC.
ARID-X 400 - 750
DESCRIPTION400500/750
GENERAL
ELECTRICAL
NOTE:
TO ORDER BLOWERS OR
OVERLOAD REFER TO
P AR T NUMBER ON ITEM.
*:
IEC CONTACTOR USED IN ALL
FM, PD & HM DRYERS AND CLL
POWER PACKS WITH SERIAL
NUMBERS GREA TER THAN
D14650
HEATERS
Dryer Filter Element8301 18301 1
Zone V alve Air Cylinder8389783897
Thermocouple (Process)8217482174
Thermocouple (Tower)8217582175
Desiccant #80082 (Lbs/Machine)262 lbs 262 lbs.
Tower Clamp8219782197
Tower Gasket8381583815
Pressure Switch8281382813
Regulator8299582995
MAC V alve8378383783
Caster (Swivel)8231 182311
Caster (Fixed)8231282312
MICRO
Disconnect82714
Main Board82071
Display Board82072
Transformer82245
Current Transformer82246
Main Contactor82904
Solid State Relay82302
IEC Contactor80576
IEC Contactor*84860
Solid State Heater Relay82302
Dual Solid State Board82870
Safety Thermal Switch(Tower)80221
Safety Thermal Switch (Process)80551
Transformer .05084131
Dewpoint Sensor81908
400V480V575V
Regeneration (Cone Style)81923 81367 81494
HP Center (Flat Style)82506 82517 84046
Process82047 83845 84609
Page 14
OPERA TING MANUAL - HP4-X 400-750 FM DRYERS
Revision 10/8/02
DRI-AIRINDUSTRIES, INC.
NOTES:
OPERA TING MANUAL - HP4-X 400-750 FM DR YERS
Revision 10/8/02
Page 15
DRI-AIRINDUSTRIES, INC.
NOTES:
Page 16
OPERA TING MANUAL - HP4-X 400-750 FM DRYERS
Revision 10/8/02
DRI-AIRINDUSTRIES, INC.
NOTES:
OPERA TING MANUAL - HP4-X 400-750 FM DR YERS
Revision 10/8/02
Page 17