Standard Electrics----------------------------------------- 1 1
To Set Temperature: -------------------------------------- 11
Microprocessor Control ---------------------------------- 12
DRYER OPERATION-TROUBLE SHOOTING --------- 13
DRYER OPERA TION-DETAILED DIAGNOSIS -------- 14
DRI-AIR ROT AR Y ZONE VALVE--------------------------- 15
PARTS LISTS
OPERA TING MANUAL - ARID-X, HP4-X 18-100 FM DR YERS
Revision 10/8/02
Page 3
DRI-AIRINDUSTRIES, INC.
DRYER OPERATION/
FEATURES
The ARID-X dryer series is a dual bed design that provides a
constant supply of dry air to the material hopper. While one
bed is removing moisture from the process air the other is
regenerating by heating the desiccant to a high temperature.
Once the regenerated bed cools down, the Zone V alve
switches the airflow, and the newly regenerated bed is used to
desiccate the process air stream. The saturated bed is now
regenerated in the same manner, completing the regeneration
cycle. The cycle is depicted Page 8.
The airflow design of the ARID-X dryers makes the
regeneration cycle more efficient because we utilize a small
amount of the desiccated process air rather than ambient air
to regenerate the desiccant bed. This reduces the impact of
the high moisture content of the ambient air, which would
contaminate the desiccant bed, and allows the dryer to attain
a lower dew point. Please see the Air Flow Schematic on
Page 6.
where two are stacked, one over the other. This nearly
doubles the amount of desiccant available for drying the
process air stream, and because of the tower design, the
dryer is able to regenerate the desiccant in the same time as
our ARID-X series. This allows the dryer to operate in very
high humidity conditions without affecting the process air dew
point. In fact, this design produces dew point levels of – 40’ to
-80’ C for faster more complete drying of your material. Please
see the Air FLow Diagram on Page 7.
inner shell surrounded by a stainless steel jacketed insulation
layer. The easily removable stainless steel spreader cone
promotes proper material flow to ensure that the material is
dried efficiently and no dried material is left at the hopper
bottom that needs to be fed out prior to operating. You must
ensure that your hopper is adequately sized for your usage
rate and is kept filled, to ensure that you have sufficient time to
dry the material.
OPERA TING MANUAL - ARID-X , HP4-X 18-100 FM DRYERS
Revision 10/8/02
DRYER OPERATION/
FEATURES (Cont.)
DRI-AIRINDUSTRIES, INC.
Dryer Controls
The ARID-X series can be supplied with the standard PLC
Control Module or the advanced Microprocessor Control
Module, while the HP4-X series is only available with the
Microprocessor Control Module.
The PLC Control module includes a PLC control board,
display board, temperature controller and touch pad that is
programmed for the drying cycle described above. The
controller, display board and touch pad indicate the machine
status, alarms, set points and allow you to enter operational
settings for the dryer. These are explained in more detail later
in this manual.
The Microprocessor Control Module is one of the most
sophisticated yet operator friendly controls on the market. It
has many more features than the PLC control module that
provide the operator with more control and operational
flexibility with the dryer. These features and the operating
instructions are covered in detail in the Microprocessor
Control Instruction Manual included with your dryer.
OPERA TING MANUAL - ARID-X, HP4-X 18-100 FM DR YERS
Revision 10/8/02
Page 5
AIR FLOW SCHEMATIC
FOR ARID-X DRYERS
DRI-AIRINDUSTRIES, INC.
CONTROL
THER MOCOU PLE
H1
VORTEX BLOWER
4-WAY ZO NE
VENT
REGENERATION
AND PROC ESS
HEATER
SAFETY THERMAL
VALVE
XX
FILTER
CONTROL
THER MOCOU PLE
H2
CONTROL
THER MOCOU PLE
L1
Page 6
CONTROL
THER MOCOU PLE
L2
SAFETY THERMAL
TO HOPPER
PROCESS HEATER
(APD 5-9)
OPERA TING MANUAL - ARID-X , HP4-X 18-100 FM DRYERS
Revision 10/8/02
AIR FLOW SCHEMATIC
FOR HP4-X DRYERS
DRI-AIRINDUSTRIES, INC.
CONTROL
THERMOCOUPLE
H1
CONTROL
THERMOCOUPLE *
M1
CONTROL
THERMOCOUPLE
L1
VORTEX BLOWER
VENT
SAFETY THERMAL
SECONDARY
REGENERATION
HEATER
4-WAY ZON E
VA LV E
XX
FILTER
CONTROL
THERMOCOUPLE
H2
CONTROL
THERMOCOUPLE *
M2
CONTROL
THERMOCOUPLE
L2
SAFETY THERMAL
REGENERATION
AND PROC ESS
HEATER
* - CONTROL THERMOCOUPLE
FOR PLC CONTROL ONLY
OPERA TING MANUAL - ARID-X, HP4-X 18-100 FM DR YERS
Revision 10/8/02
REGENERATION
AND PROC ESS
HEATER
SAFETY THERMAL
TO HOPPER
PROCESS HEATER
(H P D 5 -9 )
Page 7
DRYER CYCLE
DIAGRAM
DRI-AIRINDUSTRIES, INC.
Zo ne 1 C o o ling
Va lv e Shif t s
Zo ne 1 H e a ti ng
Valve Shif t s
Dryer Cycle
Diagram
D esicant Beds
XX
Zo ne 2 H e a ti ng
Zo ne 2 C o o ling
Page 8
OPERA TING MANUAL - ARID-X , HP4-X 18-100 FM DRYERS
Revision 10/8/02
DRI-AIRINDUSTRIES, INC.
PLC ST ANDARD
ELECTRICS
U2A
Jp7
R11
R12
R13
R14
OSC1
DISPLAY B O ARD - P/N 83401
The control package includes a PLC controller which is
programmed for the drying cycle previously discussed. The
display board indicates the machine status, heater operation
and alarms. See section on start up for details.
Below are descriptions of the inputs and outputs of the PLC
which are used for trouble shooting. A lit LED indicates the
input or output is actuated. All inputs are 12 volts AC and all
outputs are 1 10 volts AC and 15 v DC to the heater relays.
Refer to the electrical schematic for more detail.
ARID-X50-100
Z2 TOP HEATER
Z1 TOP HEATER
+-
+-
SS4
SS3
J11A
11
Rn7
OSC3
U9
+
U5
S2
PORT
U2
OSC1
D16
J12
R36
J5
DRI-AIR INDUSTRIES
EXPANDER BD REV C
Z2 BOTTOM HEATER
PROCESS HEATER
+
SS5
-
J11
+
C15C13
S1
Z1 BOTTOM HEATER
+
+
SS1
SS2
-
-
D8D11
J118
D9D13
J2
D10D14
D12
OSC2
D15
C14
+
D20
++
C20
U7
C11
P/N 84100
MOTHER B OARD
Tb2
C14
8 UNUSED
8A UNUSED
9 UNUSED
9A UNUSED
10 ALARM (OPTIONAL)
11 HIGHTEMP. ALARM (OPTIONAL)
12 UNUSED
AL1
T1
AL2
110 VAC
13 MAIN CONTACTOR/TEMPCONTROL
14 ZONE VALVE
FROM XFORMER
CR1
M2
50
14
XX
J2
DegC
X10
JP3
1
2
C9
C4
U10
C3
U1
C2
C1
NON H.P.
50-300
#9TEMP.CONTSIGNAL
SAFETY
TC1
UNUSED
OL1
C101234567
UNUSED
UNUSED
7DAYTIMER
HI TEMP. ALARM SIGNAL
TC1
7DAYTIMER
UNUSED
UNUSED
+
C7
C21
C19
Rgain
C20
C13C14C15C16C17
C12
TC re v B
-+-+-+-+-+-+-
THERMOCOUPLE BOARD
H2H1M2M1L2
J1
ANALOG
TC
JP2
1
2
3
C8
3
C18
OSC1
C5
C6
JP1
1
2
L1
C11
C10
Ch5 Ch4 C h3 C h2PWRCh1 Ch0
UNUSED
OPERA TING MANUAL - ARID-X, HP4-X 18-100 FM DR YERS
Revision 10/8/02
C19 J5
C18
D8
D9
D11
D10
D12
D13
D14
J2
U8
L1
L2
JUMP
GROUND
QT9
QT8QT7QT6QT5
8
11
9
10
U5
U18
C0
C1
H.P ONLY 50-100 PROCESS TUBE
U9
C2
Jp7
Rn3
Rn4
U1
R1R2R3R4R5
012
R38
C1
Tb1
Rn7
R2
OSC2
C15
U6
C13
OSC1
U4
U3
C8
U11
OSC3
C2
C4C5C6
C7
Rn5
C3
D16
R37
C11
C16
Jp6
Jp5
C12
U2
R6
Jp1
3
567
4
C17
R8
R7
C23
Jp2
Jp3
C22
OUTPUTS
POW E R
D15
C9
+C18
Br1+
L1
Jp4
UNUSED
UNUSED
INPUTS
HI TEMP
REV E
MAIN
SAFETY
TEMP
50-300
Rn6
D0 D1 D2 D3 D4 D5 D6 D7
NON H.P.
PLC03
mal l
S
C2
Z1
L2
Page 9
DRI-AIRINDUSTRIES, INC.
INSTALLATION
PROCEDURE
For all Dri-Air models except ARID-X 10, AHM-1, & PDII
Electrical Connection:
Open electrical access door on the front of the machine by
turning the disconnect off and turning the lower clamping
screw 1/2 turn counterclockwise. Locate the disconnect by
following the operating handle down to the electrical panel.
Insert the incoming power cable or conduit through the hole
provided on the side of the machine.
« use approved wire and fastening means «
Wire incoming power to the top of the disconnect as shown in
the diagrams below.
NOTE:
When 3 wire supplies are used in place of 4 wire supplies,
a control transformer is required.
XX
3 PHASE DRYER INST ALLATION
CHECK FOR CORRECT MOTOR ROTATION
BEFORE RUNNING DRYER
To check motor rotation.......
Leave the electrical cabinet door open so the blower can be
observed. Turn on the power to the dryer and press the ON/ST ART touch pad and then immediately press the OFF/STOP
touch pad. Observe the cooling fan on the top of the blower
motor and verify the fan is turning clockwise. If the motor is
not turning clockwise, switch any two adjacent supply wires.
The unit is now ready for operation.
Page 10
OPERA TING MANUAL - ARID-X , HP4-X 18-100 FM DRYERS
Revision 10/8/02
START-UP PROCEDURE
DRI-AIRINDUSTRIES, INC.
Standard Electrics
Operating this unit is very simple. Once the dryer is
connected to the facility power supply, the unit can be started
by turning the disconnect located on the electrical panel
enclosure to the ON position and pressing the ON button on
the Control Panel Key Pad. To shut the dryer off, simply push
the OFF button on the Control Panel Key Pad and turn the
disconnect to the OFF position.
Setting the process air temperature is done using the Digital
Controller.
For a more detailed explanation, see the following sections.
Control Panel - Operating Display
Turn power on to dryer using disconnect.
1. POWER light indicates power to the unit is on.
Press ON button on key pad.
2. Illuminated BLOWER Light indicates Blower is on.
3. Flashing ZONE light indicates bed is in Regeneration
cycle.
4. Steady ZONE light means bed is in cooling cycle.
5. Illuminated HEA TER light indicates heater is on.
Alarm Conditions:
6. Flashing HIGH TEMP. ALARM indicates an over or
under temp alarm. Unit shuts down.
7. Steady HIGH TEMP. ALARM light indicates a
thermocouple has failed. Further diagnostics are
required.
8. Flashing ALARM light indicates a safety override
condition has occured. Dryer shuts down.
XX
Digital Controller - Setting Process Air T emperature:
Press SET button - temperature set display will flash.
Press up arrow to increase temperature and down arrow to
decrease temperature.
Press SET again to enter the new temperature.
If the display flashes, the temperature is out of the control
range.
If the display shows 0000 the thermocouple is not connected
or is faulty .
OPERA TING MANUAL - ARID-X, HP4-X 18-100 FM DR YERS
Revision 10/8/02
Page 11
DRI-AIRINDUSTRIES, INC.
Microprocessor Control
1. Power light indicates there is power on.
2. After initializing, dri Air will be displayed.
3. Press
4. To set the temperature:
5. Left display indicates actual temperature
6. Right display shows dewpoint or set temp
7. To set high temp alarm: (degrees over setting)
8. Status block indicates heater on or fault
9. See manual for setting 7-day timer .
10. Configuration of the dryer parameters is done
For a more detailed explanation of the features and operation
of the Microprocessor Controller, please consult the
Microprocessor Control Operating manual enclosed with this
unit.
START to start the dryer.
press SET - right display shows set temp
change setting using arrow keys
press ENTER to input new setting
press TEMP D.POINT button to change
press ALARM - right display shows setting
change setting using arrow keys
press ENTER to input new setting
using the setup button. see manual.
Page 12
OPERA TING MANUAL - ARID-X , HP4-X 18-100 FM DRYERS
Revision 10/8/02
DRYER OPERATION
TROUBLE SHOOTING
DRI-AIRINDUSTRIES, INC.
The new Dri-Air Standard PLC and MICROPROCESSOR
Electrics were designed for quick diagnosis of problems.
The following steps should be done before proceeding with
other diagnostic steps.
1. Check the Power Circuit:
a. Incoming fuses or circuit breaker
b. All dryer fuses:
Each fuse, with the exception of the main fuses, has
a blown fuse indicator light that illuminates when the
fuse is blown.
c. Is power supplied to the unit?
d. Check heater continuity using a volt ohmmeter.
2. Compressed Air:
For those models that require compressed air.
a. Is compressed air connected with at least 60 PSI
b. Check water separator and drain if necessary
c. Pressure gage should read 60 PSI
3. Air Flow Circuit:
a. Ensure Zone V alve position corresponds to the
regeneration cycle by comparing the Zone position lights
on the Zone V alve to the ZONE position lights on the
dryer panel.
b. Make sure that all hoses are connected, not crushed,
and free from obstructions.
c. Inspect filter and make sure cover is tight and the filter is
clean.
4. Control Circuit:
a. Using the PLC/MICRO Display Panel ZONE indicator
lights as a guide for the dryer regeneration cycle, check
that all inputs/outputs are proper for the part of the
regeneration cycle that the machine is in.
b. Monitor the PLC output lights to ensure the
corresponding LED on the power board is illuminated
and there is an output voltage to the heater.
5. Operating Conditions:
a. Check the process temperature. It should
below 140° F (60° C) because the unit will go into high
temp alarm.
not be set
OPERA TING MANUAL - ARID-X, HP4-X 18-100 FM DR YERS
Revision 10/8/02
1. Check circuit breakers (CB1) or incoming fuses inside
control box to see if they are tripped or blown. Reset
circuit breakers by turning them off and then on.
2. Check small fuses (FU1 & FU2) next to contactor. The
LED will be lit if they are blown. Replace if necessary by
opening the fuse holder and put new fuse into holder.
3. Check that incoming power to the unit is proper.
4. Check safety snap discs.
Alarm light is flashing: Unit will not run.
Main contactor is not pulling in.
1. Check the motor overload OL1 located in the panel. If it
is tripped, the window will show as orange/yellow. Reset
overload by pushing in the reset button.
Machine will not run: High T emp Alarm Light flashing:
This indicates that the temperature has exceeded the high
limit programmed into the temperature control or the set
temperature can not be reached.
Press stop and restart machine holding in the start button.
Monitor the actual temperature to see if it exceeds the set
point or can not reach the set point. If it can not reach set
point, see section below.
Machine will not run. High T emperature Alarm on, not
flashing:
1. This indicates an “open” thermocouple or the
temperature in the desiccant tower exceeded 900° F.
Machine will not reach temperature:
1. If the process heater light is not lit.
A.Check output from temperature controller and input to
PLC.
B.Check the thermocouple. The tip should be in the
middle of the hose.
2. If the process heater light is lit.
A.Check fuses on power board
B.Check solid state relays on power board.
C.Check that the air flow is correct.
D.Check blower rotation
E.Check heater for continuity .
Page 14
OPERA TING MANUAL - ARID-X , HP4-X 18-100 FM DRYERS
Revision 10/8/02
DRI-AIRINDUSTRIES, INC.
Check the limit first by pressing the SET button on the
temperature control and holding until AL is displayed. The
setting shown indicated the amount over set point that the
alarm will be actuated. It is factory set to 50°F (30°C) and
should not be set below 30°F (16°C) or it will actuate too soon.
If the temp exceeds the set point check the following:
1. Remove the hose from the top of the hopper to check air
flow. There should be air flow out of the hopper with a
suction on the hose. If there is little or no flow, check the
inlet hose.
2. Inspect the filter to make sure that it is clean and not
affecting the air flow .
3. Check the power boards to see if one of the solid state
relays has failed on. Using an ammeter or voltmeter on
the output to the heater, see if there is power when the
LED is not lit which will indicate a failed relay .
4. Check the valve position.
DRI-AIR
ROTAR Y ZONE VALVE
The Dri-Air rotary valve is designed to provide very little flow
restriction and no leakage. It incorporates high temperature,
self adjusting seals for years of trouble free service. The
electrical controls are built into the end of the valve and
include position lights.
Trouble shooting is easy. If the lights indicating position do not
match the zone displayed on the control panel, or there are no
lights, the valve is not working properly. See if the cam is
actuating a switch.
DO NOT PUT FINGERS INTO VALVE WITH POWER ON
Check all electrical connections to make sure they are tight.
Contact factory with the serial number of the dryer for a
replacement valve.
OPERA TING MANUAL - ARID-X, HP4-X 18-100 FM DR YERS
Revision 10/8/02
Page 15
DRI-AIRINDUSTRIES, INC.
ARID-X & HP4-X 18 - 35
PARTS LISTS
GENERAL
ELECTRICAL
NOTE:
TO ORDER BLOWERS OR
OVERLOAD REFER TO
P AR T NUMBER ON ITEM.
*:
IEC CONTACTOR USED IN ALL
FM, PD & HM DRYERS AND CLL
POWER PACKS WITH SERIAL
NUMBERS GREA TER THAN
D14650
DESCRIPTIONArid-XHP4-X
Dryer Filter Element8105581055
Zone V alve8370583705
Thermocouple (Process)8405484054
Desiccant 80082 (Lbs/Machine)8 lbs.14 lbs.
Tower Clamp8101780017
Tower Gasket8102881028
Regeneration V alveNRNR
Pressure SwitchNRNR
RegulatorNRNR
MAC V alveNRNR
Caster (Swivel)8098180981
STDMICRO
Disconnect8230882308
Temperature Control (RKC CB-100)84016NR
Main Board8410082071
Display Board8340182072
Thermocouple Board84049NR
Transformer8343784131
Current TransformerNR82246
Main Contactor8227082270
Solid State Relay8230282302
IEC Contactor8057680576
IEC Contactor*8486084860
Power Board8349383493
Power Board (208 & 230 v Dryers)8408084080
Single Pole Relay8249682496
Double Pole Relay8058780587
Dual Solid State BoardNR82870
Toggle Switch8046680466
Safety Thermal Switch(Tower)8022180221
Thermocouple (Tower)8217482174
TRI-Solid State BoardNR83468
Dewpoint Sensor8190881908
Page 16
HEATERS
208V 230V 400V 480V 575V
Regeneration (Cone Style) 83342 83373 83982 83374 84235
HP Center (Flat Style)82373 82373 83958 82505 84260
ProcessNRNRNRNRNR
OPERA TING MANUAL - ARID-X , HP4-X 18-100 FM DRYERS
Revision 10/8/02
DRI-AIRINDUSTRIES, INC.
ARID-X & HP4-X 50 - 100
DESCRIPTIONArid-XHP4-X
GENERAL
ELECTRICAL
NOTE:
TO ORDER BLOWERS OR
OVERLOAD REFER TO
P AR T NUMBER ON ITEM.
*:
IEC CONT ACT OR USED IN ALL
FM, PD & HM DRYERS AND CLL
POWER P ACKS WITH SERIAL
NUMBERS GREA TER THAN
D14650
Dryer Filter Element8133181331
Zone V alve8370583705
Thermocouple (Process)8405484054
Desiccant (Pounds / Machine)30 lbs.50 lbs.
Tower Clamp8117281172
Tower Gasket8279582795
Regeneration V alveNRNR
Pressure SwitchNRNR
RegulatorNRNR
MAC V alveNRNR
Caster (Swivel)8098180981
STDMICRO
Disconnect8230882308
Temperature Control (RKC CB-100)84016NR
Main Board8410082071
Display Board8340182072
Thermocouple Board84049NR
Transformer8343784131
Current TransformerNR82246
Main Contactor8227082270
Solid State Relay8230282302
IEC Contactor8057680576
IEC Contactor*8486084860
Power Board8349383493
Power Board (208 & 230 v Dryers)8408084080
Single Pole Relay8249682496
Double Pole Relay8058780587
Dual Solid State BoardNR82870
T oggle Switch8046680466
Safety Thermal Switch(T ower)8022180221
Safety Thermal Switch(Process)8055180551
Thermocouple (Tower)8217582175
Transformer .0508224582245
TRI-Solid State BoardNR83468
Dewpoint Sensor8190881908
HEATERS
Regeneration (Cone Style)81351 81766 81366 81432
HP Center (Flat Style)82364 83934 82493 83372
Process82343 84204 82319 84065
OPERA TING MANUAL - ARID-X, HP4-X 18-100 FM DR YERS
Revision 10/8/02
230V400V480V575V
Page 17
DRI-AIRINDUSTRIES, INC.
NOTES:
Page 18
OPERA TING MANUAL - ARID-X , HP4-X 18-100 FM DRYERS
Revision 10/8/02
DRI-AIRINDUSTRIES, INC.
NOTES:
OPERA TING MANUAL - ARID-X, HP4-X 18-100 FM DR YERS
Revision 10/8/02
Page 19
DRI-AIRINDUSTRIES, INC.
NOTES:
Page 20
OPERA TING MANUAL - ARID-X , HP4-X 18-100 FM DRYERS
Revision 10/8/02