Dri-Air Industries HA750B, HA1500B, HA1000B Operating Manual

DRI-AIR INDUSTRIES, INC.
HA750B - 1500B
HOT AIR DRYER
OPERATING MANUAL
OPERA TING MANUAL - HA750-1500B HOT AIR DR YERS Revision 10/8/02
Page 1
DRI-AIR INDUSTRIES, INC.
Page 2
DRI-AIR INDUSTRIES, INC.
16 THOMPSON ROAD P.O. BOX 1020 EAST WINDSOR, CT 06088-1020
Tel. (860) 627-5110 FAX (860) 623-4477
Internet http://www.dri-air.com e-mail: sales@dri-air.com
DRI-AIR INDUSTRIES, INC.
CONTENTS
DRYER OPERA TION/FEATURES---------------------------4 INST ALLATION PROCEDURE -------------------------------6
Electrical Connection ---------------------------------------6 Check for correct motor rotation -------------------------6 Thermocouple Connection --------------------------------6
START-UP PROCEDURE -------------------------------------7
Set Temperature: -------------------------------------------- 7
DRYER OPERATION-TROUBLE SHOOTING ----------- 8
Dryer Operation---------------------------------------------- 8
Trouble-Shooting --------------------------------------------9 P AR TS LIST HA750/1000 ----------------------------------- 10 P A R TS LIST HA1500 ----------------------------------------- 11
OPERA TING MANUAL - HA750-1500B HOT AIR DR YERS Revision 10/8/02
Page 3
DRI-AIR INDUSTRIES, INC.
DRYER OPERATION/
FEATURES
The HA750-1500 Hot Air dryer series is ideal for drying non­hygroscopic resins such as polypropylene and polyethylene. The moisture associated with these resins resides on the surface of the pellets. The surface moisture on these resins is easily removed by a flow of hot air.
Resins such as polycarbonates, ABS, and Nylons are hygroscopic, absorbing moisture into the pellet. These resins require a dryer equipped to desiccate the air stream and may not be suitable for a Hot Air dryer.
Air Flow
The airflow of the HA series dryers is circulated through a heater cabinet containing up to 9 tubular heaters and the material hopper by a fan type blower specified below.
HA750 750 cfm Blower HA1000 1000 cfm Blower HA1500 1500 cfm Blower
The HA series dryers are compatible with many types of material hoppers. The hopper must be designed to allow good material flow and should be equipped with a diffuser basket so that air flow through the hopper is not impeded. To ensure proper air flow, we strongly recommend that you use a Dri-Air hopper described below.
Hopper Design
These dryers are designed to be used with our large capacity 1000, 1500, and 2000 lb. hoppers. Dri-Air’s ”all stainless” hopper design utilizes a stainless steel inner shell surrounded by a stainless steel jacketed insulation layer. The easily removable stainless steel spreader cone promotes proper material flow to ensure that the material is dried efficiently and no undried material is left at the hopper bottom that needs to be fed out prior to operating. You must ensure that your hopper is adequately sized for your usage rate and is kept filled, to ensure that you have sufficient time to dry the material.
Dryer Controls
The HA series dryers are supplied with a digital temperature controller that allows the operator to easily monitor dryer performance and input operational settings. The controller is factory set and requires no additional programming.
The controller is used in conjunction with a 6 inch long 0.125”
Page 4
DRI-AIR INDUSTRIES, INC.
DRYER OPERATION/
FEATURES (Cont.)
diameter Type J thermocouple that is placed in inlet air stream of the material hopper.
These dryers are designed to operate between 120 and 250 degrees F (49-121 degrees C). Operating outside these parameters may lead to temperature control problems.
Dryer Configuration
The HA750 - 1500 series dryers are designed to be portable and utilize a very compact footprint. The dryer’s base dimensions are typically 39” wide by 42” long by 78” high. (99.1 x 106.7 x 198.1 cm) The dryers are equipped to operate at 380/460/600 volts, 3 phase at 50/60 HZ.
The dryer is configured with a 6” (15.3 cm) O.D. process air outlet and supplied with 12 feet (3.6 meters) of 500 degree F (260 deg. C) rated hose to connect with the material hopper and a 0.125” Type J thermocouple with an armored connector wire.
Setup and installation instructions are covered on page 6 of this manual.