Air inlet .......................................................................................................32 dB(A)
Air vent .....................................................................................................34 dB(A)
3
/h and 150 Pa external) ............75 W
3
/h
3
/h
Weight ............................................................................................................ 68 kg
Heat recovery level of the plate heat exchanger
according to VDI 2071 with nominal volumetric fl ow .......................................85 %
Customer information
This handbook contains important notes and tips for the operation of your comfort ventilation
unit which will protect you from personal injury and guarantee a long service life for the unit. The
fi gures all depict the right-hand version of the unit (supply air connection located on the right).
All instructions are equally applicable to the left-hand version (supply air connection located on
the left). Please keep the operating instructions for future reference. Please pay attention to the
safety notes.
Product description
The aerosilent topo comfort ventilation unit consists of a ventilation module with highly
effi cient heat recovery characteristics and an optional heat register.
Proper application
The unit is designed for the ventilation and heating (optional) of living rooms and lounges
in passive houses and, if applicable, for near-passive buildings depending on the calculation and building design.
Unsuitable application
No uses other than those specifi ed under 'Proper usage' are permissible.
The unit must not be used to dehumidify buildings under construction. Drying and heating
a building structure can cause considerable damage to the unit.. The ventilation of rooms
with extremely high humidity levels, such as saunas, or heavily contaminated extract air
(fumes, air with a high fat content, explosive extract air) is also not permitted..
Safety notes
WARNING: Indicates that failure to follow the recommended safety procedures could result in damage to the unit or personal injury.
CAUTION: Indicates that failure to observe the recommended safety procedures could result in damage to the unit.
NOTE: Helpful information and useful tips.
Operating, Maintenance, Commissioning
Page 5
Operation
The aerosilent topo is operated using a room operating panel. Two different room operating panels are available that provide different functions:
•
3-level switch
3-stage timer•
The 3-level switch provides simple, manual fan control. In contrast, the 3-stage timer can be used
to set an individual weekly programme.
3-level switch
Selecting the fan level
You use the function button to select the required fan level. Once you have pressed the
button, the LED for the activated level lights up.
0 ... System off
1 ... Reduced air quantity
2 ... Nominal air quantity
3 ... Increased air quantity
Special 'Party' mode
This function sets the ventilation unit to level 3 for one hour. Press the function button until
LED "3" fl ashes. Once the hour has elapsed, the fan level automatically returns to the
level that was previously set.