DreamLine SHDR6160762006, SHDR6160762008, SHDR6160762007, SHDR6160622008, SHDR6160622007 User Manual

...
Page 1
ENIGMA-XO
SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS
IMPORTANT
DreamLine For the latest up-to-date technical drawings, manuals, warranty information or additional details please refer to your model’s web page on DreamLine.com
reserves the right to alter, modify or redesign products at any time without prior notice.
SHDR-61606220-##
Right Hand door installation shown
Please review this entire manual prior to installation.
For more information about DreamLine® Shower Doors & Tub Doors please visit DreamLine.com
ENIGMA-XO manual Ver 1 Rev 2 03/2018
SHDR-61487620-## SHDR-61547620-## SHDR-61607620-##
SHDR-61727620-##
##=finish 06- Oil Rubbed Bronze 07- Brushed Stainless Steel 08- Polished Stainless Steel
©2018 DreamLine. All Rights Reserved
Page 2
This model is treated with DreamLine’s
TM
exclusive ClearMax
Glass technology. This is a specially formulated coating that prevents the build up of soap and water spots.
Install the surface with the ClearMaxTM label towards the inside of the shower. Please note that depending on the model, the glass may be coated on either one or both surfaces.
For best results, squeegee the glass after each use and dry with a soft cloth.
ENIGMA-XO manual Ver 1 Rev 2 03/2018
©2018 DreamLine. All Rights Reserved
Page 3
Table of Contents
Section title
Model Information
Reinforcement Information
Preparation Tools
Parts List
Installation
Vinyl Seals
Stoppers
SafeStop™ Bumper
Wheel Adjustments
Product maintenance
Page #
3
4
5
6
7-8
9-27
23
24
25-26
28
29
ENIGMA-XO manual Ver 1 Rev 2 03/2018
©2018 DreamLine. All Rights Reserved
Page 4
IMPORTANT! This manual will describe the installation of the single threshold
!
model of the Enigma-XO. Use this manual when installing the Enigma-XO single threshold model.
For the ENIGMA-XO Enclosure installation: Start with the Enigma-X/Enigma-XO Enclosure Return Panel manual that is packaged with the return panel glass first for the installation of the return panel glass, then use this manual for the installation of the door section.
2
nd
ENIGMA-XO
SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS
IMPORTANT
®
DreamLine
reserves the right to alter, modify or redesign products at any time without prior notice.
For the latest up-to-date technical drawings, manuals, warranty information or additional details please refer to your model’s web page on DreamLine.com
SHDR-61606220-##
SHDR-61727620-##
SHDR-61487620-## SHDR-61547620-## SHDR-61607620-##
Right Hand door installation shown
Please review this entire manual prior to installation.
For more information about DreamLine® Shower Doors & Tub Doors please visit DreamLine.com
©2018 DreamLine. All Rights Reserved
ENIGMA-XO manual Ver 1 Rev 2 03/2018
ENIGMA-XO
SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS
IMPORTANT
®
reserves the right to alter, modify or redesign products at any time without prior notice.
DreamLine For the latest up-to-date technical drawings, manuals, warranty information or additional details please refer to your model’s web page on DreamLine.com
SHDR-61606220-##
Right Hand door installation shown
For more information about DreamLine® Shower Doors & Tub Doors please visit DreamLine.com
ENIGMA-XO manual Ver 1 Rev 2 03/2018
st
1
##=finish 06- Oil Rubbed Bronze 07- Brushed Stainless Steel 08- Polished Stainless Steel
ENIGMA-X / ENIGMA-XO Shower Enclosure Return Panel manual Ver 1 01/2018
SHDR-61487620-## SHDR-61547620-## SHDR-61607620-##
Please review this entire manual prior to installation.
ENIGMA-X/ENIGMA-XO Enclosure Return Panel
SHOWER ENCLOSURE RETURN PANEL INSTALLATION INSTRUCTIONS
IMPORTANT
®
reserves the right to alter, modify or redesign products at any time without prior notice.
DreamLine For the latest up-to-date technical drawings, manuals, warranty information or additional details please refer to your model’s web page on DreamLine.com
NOTE: Use this manual FIRST to install the Return Panel Glass. Then use the manual packaged with the door glass box to continue
!
with the installation of the shower door section of the enclosure.
Left-Hand Return panel installation
Right-Hand Return panel installation
Please review this entire manual prior to installation.
®
Shower Doors, Tub Doors & Enclosures, please visit DreamLine.com
For more information about DreamLine
©2018 DreamLine. All Rights Reserved
SHDR-61727620-##
©2018 DreamLine. All Rights Reserved
##=finish 06- Oil Rubbed Bronze 07- Brushed Stainless Steel 08- Polished Stainless Steel
+
ENIGMA-X/ENIGMA-XO Enclosure Return Panel
SHOWER ENCLOSURE RETURN PANEL INSTALLATION INSTRUCTIONS
IMPORTANT
®
DreamLine
reserves the right to alter, modify or redesign products at any time without prior notice.
For the latest up-to-date technical drawings, manuals, warranty information or additional details please refer to your model’s web page on DreamLine.com
NOTE: Use this manual FIRST to install the Return Panel Glass. Then use the manual packaged with the door glass box to continue
!
with the installation of the shower door section of the enclosure.
Left-Hand Return panel installation
Right-Hand Return panel installation
Please review this entire manual prior to installation.
®
For more information about DreamLine
Shower Doors, Tub Doors & Enclosures, please visit DreamLine.com
ENIGMA-X / ENIGMA-XO Shower Enclosure Return Panel manual Ver 1 01/2018
©2018 DreamLine. All Rights Reserved
2
nd
ENIGMA-XO
SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS
IMPORTANT
®
DreamLine
reserves the right to alter, modify or redesign products at any time without prior notice.
For the latest up-to-date technical drawings, manuals, warranty information or additional details please refer to your model’s web page on DreamLine.com
SHDR-61606220-##
SHDR-61727620-##
SHDR-61487620-## SHDR-61547620-## SHDR-61607620-##
Right Hand door installation shown
Please review this entire manual prior to installation.
For more information about DreamLine® Shower Doors & Tub Doors please visit DreamLine.com
©2018 DreamLine. All Rights Reserved
ENIGMA-XO manual Ver 1 Rev 2 03/2018
st
1
##=finish 06- Oil Rubbed Bronze 07- Brushed Stainless Steel 08- Polished Stainless Steel
ENIGMA-X/ENIGMA-XO Enclosure Return Panel
SHOWER ENCLOSURE RETURN PANEL INSTALLATION INSTRUCTIONS
IMPORTANT
®
reserves the right to alter, modify or redesign products at any time without prior notice.
DreamLine For the latest up-to-date technical drawings, manuals, warranty information or additional details please refer to your model’s web page on DreamLine.com
NOTE: Use this manual FIRST to install the Return Panel Glass. Then use the manual packaged with the door glass box to continue
!
with the installation of the shower door section of the enclosure.
Left-Hand Return panel installation
Right-Hand Return panel installation
Please review this entire manual prior to installation.
®
Shower Doors, Tub Doors & Enclosures, please visit DreamLine.com
For more information about DreamLine
ENIGMA-X / ENIGMA-XO Shower Enclosure Return Panel manual Ver 1 01/2018
©2018 DreamLine. All Rights Reserved
ENIGMA-XO Enclosure MODEL #s
SHEN-6132482-## SHEN-6132602-## SHEN-6134482-## SHEN-6134542-## SHEN-6134602-##
ENIGMA-XO manual Ver 1 Rev 2 03/2018
ENIGMA-XO Enclosure MODEL #s
SHEN-6132722-## SHEN-6134722-##
©2018 DreamLine. All Rights Reserved
2
Page 5
A
B
B
A
C
PANEL
G
D
DOOR
F
E
IMPORTANT INFORMATION REGARDING THE INSTALLATION OF THIS SHOWER DOOR
!
Right hand door installation shown as an example
Guide Rail Brackets must be firmly
A
attached to the wall. Installation into a stud is strongly recommended. All of the guide rail bracket set screws must be tightened.
Thread Lock must be applied to both
B
stopper set screws. Panel-side stopper must be installed into the pre-drilled stopper hole in the upper guide rail. Door-side stopper must be installed at the proper position to stop the door from contacting the wall.
C
ENIGMA-XO manual Ver 1 Rev 2 03/2018
Roller Wheel Safety Set Screws must be re-tightened after installation. Apply thread lock.
Lower Roller wheels must be adjusted
D
during installation to make contact with the Upper Guide Rail. Tighten Safety set screws. Apply thread lock.
Bumper Vinyl Seal must be installed on
E
the closing edge of the door glass
The Guide Block must be screwed to the
F
threshold and installed square to the panel glass and door glass. Installing the guide block crooked may damage the bottom edge of the door glass and lead to breakage.
Bumper is secured in position with 3M tape or
G
screwed to the wall.
PLEASE READ THE ENCLOSED INSTALLATION MANUAL FOR DETAILS REGARDING PROPER INSTALLATION.
THE LATEST VERSION OF THE INSTALLATION MANUAL IS AVAILABLE TO VIEW OR PRINT ON DREAMLINE.COM
©2018 DreamLine. All Rights Reserved
3
Page 6
Reinforcement for Enigma Series
Heavy Glass frameless sliding shower door
Install studs OR install 2”x 6” wood blocking between the studs where the
Guide Rail Brackets will attach to the wall
Stud
or
measured
from threshold*
(see list below)
2” X 6”
2” X 6”
threshold or tub deck
threshold
*Blocking height requirement (to center) as measured from threshold or tub deck: Enigma Air = 73” for shower ht / 59” for tub ht Enigma-X, Enigma-XO = 72-1/2“ for shower ht / 58-1/2” for tub ht Enigma-Z = 73-1/2” for shower ht / 59-1/2“ for tub ht Enigma = 75-1/2” for shower ht only
ENIGMA-XO manual Ver 1 Rev 2 03/2018
or tub deck
©2018 DreamLine. All Rights Reserved
4
Page 7
Preparation
1. After opening all boxes and packages, read this introduction carefully. Check that all of the needed parts are included in the package by marking all the components on the “Detailed Diagram of Shower Door Components”. Examine boxes and packages for shipping damage. If the unit has been damaged, has a finishing defect, or is missing parts, please contact our customer support department within
®
3 business days of the delivery date. Please note that DreamLine products or missing parts free of charge after 3 business days or if the product has been installed.
®
Please contact DreamLine
2. Please note that you should consult your local building codes with questions on installation
compliance standards. Building and plumbing codes may vary by location, and DreamLine responsible for code compliance standards for your project and will not accept any returns.
3. If this unit is going to be installed in a new construction, install all of the required plumbing and drainage before installing the shower. Use a competent and licensed (if required by local code)
plumber for all plumbing installation.
4. Make sure that prior to beginning the installation, the surfaces are leveled and solid and will be able to support the total weight of the unit. Also make sure the walls are at right angles. Irregular installation surface level, radius corners or improper angle of side walls will result in serious problems for your installation. Please note that some adjustments and drilling might be necessary during the installation process.
if you have any questions.
will not replace any damaged
®
is not
5. Protect all primary surfaces of the product during installation. Never set your glass down directly onto a tile floor. Leave corner protectors in place until necessary to remove them. Always use a piece of wood or cardboard to protect the bottom edge and corners of the glass prior to and during installation.
6. This unit must be installed upon a finished threshold and against finished walls.
7. NOTE! This door does not have out-of-plumb adjustment. Make sure your walls are at right angles.
8. This door requires a minimum 2-3/4”of flat threshold space for installation.
9. Note: The installation of this unit requires that you drill down into the threshold.
10. Please note that Step #11 has an option for installing the guide rail brackets to the wall using
anchors. However, the manufacturer strongly recommends installing these heavy doors to the studs or to pre-installed 2”x 6” wood reinforcements behind the wall in the area where the guide rail brackets will be attached to the wall.
!
Attention: This door is extremely heavy and requires professional installation. Two installers recommended.
!
NOTE: This door is reversible for right or left-hand door installation. The right-hand door installation is shown as an example throughout this manual. For the left-hand door installation, simply begin on the opposite wall and reverse the orientation of the steps shown.
Do Not hang or drape a towel or wash cloth over the Enigma series guide rail as this may cause the roller wheels to get stuck and possibly cause serious damage or injury.
©2018 DreamLine. All Rights Reserved
5ENIGMA-XO manual Ver 1 Rev 2 03/2018
Page 8
Tools
Level
Drill bit (Ø=1/8")
(3mm)
Painter’s Tape
Tape Measure
Drill bit (Ø=1/4")
(6mm)
Razor Knife
Pencil
Drill bit (Ø=5/16") (8mm)
Professional-grade Glass suction cup
Drill bit (Ø=3/8") (10mm)
Phillips Screwdriver
Hammer
Silicone
Chop saw
or
Hacksaw
Power Drill
Metal File
Tip: Measure the finished opening before proceeding with the installation to be sure that the
correct model size has been ordered.
Be sure to cover the shower drain to prevent losing small parts.
NOTE: Unpack your unit carefully and inspect it. Lay it out and identify all parts using the detailed
diagram and packing list in this manual as a reference. Before discarding the carton, check for small hardware bags that may have fallen to the bottom of the box. If any parts are damaged or missing, please contact DreamLine
your model configuration.
NOTE: Retain these installation instructions for future reference.
!
for replacement. The shipping boxes may contain extra parts not used in
These instructions will show the installation of the shower door. Please follow the same steps for the installation of the tub door.
©2018 DreamLine. All Rights Reserved
6ENIGMA-XO manual Ver 1 Rev 2 03/2018
Page 9
Detailed Diagram ‘A’of Shower Door Components
11
12
13
14
15
16
17
18
19
10
1
2
3
9a/9b
5
6
4
8
7
The glass surface
with the ClearMax™
label must be
installed to face
inside of the shower
26
PART#
01 Door stopper
02
03
04
05
06
07
08
9a Wall anchor Ø3/8" (10mm)
9b
10 Large Truss Head Screw ST6x55
11
DESCRIPTION
Stationary glass
Upper guide rail
Roller
Door Glass
Handle
Glass bracket
Guide rail bracket
Wall anchor Ø5/16" (8mm)
Allen Wrench 3,4,5 mm
(for 48" or 54” or 60")
30
Packing List A
PART#
QTY
2pcs
1pc
1pc
4pcs
1pc
1pc
2pcs
2pcs
2pcs
3pcs
2pcs
1set
12
13
14
15
16
17
18
19
26
30
model #s
SHDR-61606220-## SHDR-61487620-## SHDR-61547620-## SHDR-61607620-##
DESCRIPTION
Guide block (with caps)
Bumper strip
Anti-water strip
Anti-splash threshold
Threshold cap
ST4.2x40 Countersunk screw
ST4.2x55 Truss Head screw
Wall bracket
Thread Lock adhesive
Bumper
(for 48" or 54” or 60")
QTY
1pc
1pc
2pcs
1pc
1pc
2pcs
1pcs
1pc
1pc
1pc
** not used with the 72” configuration
©2018 DreamLine. All Rights Reserved
7ENIGMA-XO manual Ver 1 Rev 2 03/2018
Page 10
Detailed Diagram ‘B’ of Shower Door Components (for 72” model width only)
24
14
18
23
19
21
model #s (for 72” )
SHDR-61727620-##
PART#
DESCRIPTION
22
9
11
Packing List B
QTY PART#
25
DESCRIPTION
The glass surface
with the ClearMax™
label must be
installed to face
inside of the shower
QTY
9b
11
14
18
19
Wall anchor Ø5/16"(8mm)
Allen Wrench 3,4,5 mm 1set
Anti-water strip 1pc
ST4.2x55 Truss Head screw 1pc
Wall bracket
2pcs
1pc
21
22
23
24
25
Small stationary glass bracket
Small stationary glass Bottom bracket
Small stationary glass
Upper guide rail (for 72")
ST4.2x40 Countersunk screw
1pc
1pc
1pc
1pc
1pc
©2018 DreamLine. All Rights Reserved
8ENIGMA-XO manual Ver 1 Rev 2 03/2018
Page 11
Installation steps
1. Measure the distance between the two finished
walls at the top, middle and bottom. Measure the width at the model height (62” or 76”). This top measurement will be the “W” dimension used to cut the guide rail to the correct size for the finished opening. Also, check the threshold for level and the walls for plumb. (Fig 1)
Note: The minimum threshold requirement for the ENIGMA-XO is 2-3/4” of flat threshold space.
Top
Middle
Bottom
2-3/4” minimum
Threshold must be level.
!
2. The Upper Guide Rail (#03) has been pre-cut
for the model width of: 48”, 60” or 72”.
(Note: The actual rail is shorter than the model width by design).
Cut the Upper Guide Rail (#03) from the door end only, which is the end that is farther from the Glass Bracket (#07) holes. (Fig 2)
The length to cut off will be (L) :
Model Width – finished opening W = cut off length (L)
W
Fig 1
glass bracket holes
door end
*FOR EXAMPLE:
If the model width is 48” and the finished opening is 46”, then you will need to cut 2” off from the door end of the Guide Rail: Example: 48” – 46” = 2” cut off
*Note that this is only an example and the actual cut-off length will vary based on the actual finished opening dimension.
door end
Fig 2
Use a metal file to deburr the cut end
©2018 DreamLine. All Rights Reserved
9ENIGMA-XO manual Ver 1 Rev 2 03/2018
Page 12
stationary panel-end
door-end
3a. Attach the Upper Guide Rail (#03) to the Stationary Glass (#02)
with the Glass Brackets (#07) and tighten the bolts into the holes in the Upper Guide Rail (#03). Make sure both adjustment disks are installed in the same direction with the high spot towards the door end. (see *Note below) Make sure that the guide rail is attached parallel with the top edge of the stationary panel glass.
1
panel end
2
stopper hole
3b. Slide the Door Stoppers (#01) onto each end of the Upper
Guide Rail (#03). Secure them using the 4mm Allen Wrench (#11). Install the panel-end stopper into the pre-drilled stopper hole in the Upper Guide Rail and apply thread lock to the set screw. (Fig 3.3) Install the door-end stopper approximately 4” from the end
of the guide rail. (The door-end stopper position will be adjusted after the door glass is installed).
3c. Slide the Guide Rail Brackets (#08) onto each end of the
Upper Guide Rail (#03) and secure them. Next, assemble the Wall Bracket (#19) onto the bottom corner of the Stationary Glass (#02) with the bolt facing into the shower as shown in Fig 3.5. Use the supplied gaskets to protect the glass. (Fig. 3 and Fig. 4)
glass bracket
3
5
outside
EQ
EQ
4
thread lock
6
Fig 3
measure
disk
*NOTE: The outer glass bracket disk has an eccentric bushing
for adjustment. Be sure to install both glass bracket disks with the high spot of the bushing pointed towards the door end of the guide rail.
Door end of guide rail
High spot of disk bushing
TIP: Mark the location of the high spot on the outer surface of the adjustment disk with a felt tip pen to make adjustment easier to see.
Fig 4
©2018 DreamLine. All Rights Reserved
10ENIGMA-XO manual Ver 1 Rev 2 03/2018
Page 13
ATTENTION: This step shows the Small Stationary Glass Bracket (#21) installation for the 72” model only
(not included with the 48“ or 60” model).
4. If the model width is 72” and includes the Small
Stationary Glass (#23), attach the Small Stationary Glass Bracket (#21) to the Upper Guide Rail for 72” (#24) between the Door Stopper (#01) and the Guide Rail Bracket (#08) as shown in Fig. 5.
This bracket will be repositioned during the installation of the Small Stationary Glass (#23). (Fig 5)
1
2
Fig 5
disk
5. If the model width is 72” and includes the Small Stationary Glass (#23),
assemble the Wall Bracket (#19) onto the larger notch at the bottom corner of the Small Stationary Glass (#23). Use the provided gaskets to protect the glass. (Fig 6)
1
outside
Fig 6
2
outside
!
NOTE: For single threshold installation (shown), this bracket will be installed to the wall.
For an enclosure installation, this bracket will need to be installed into the threshold.
©2018 DreamLine. All Rights Reserved
11ENIGMA-XO manual Ver 1 Rev 2 03/2018
Page 14
6. Place the Stationary Glass (#02) with the Upper Guide Rail (#03) onto the threshold and position it
against the wall. (Note that the Stationary Glass (#02) installs to the outside of the Upper Guide Rail (#03))
Make sure the Stationary Glass (#02) and the Upper Guide Rail (#03) are level. If a horizontal adjustment is required, loosen, rotate and re-tighten the disks on the Glass Brackets (#07). (Fig 7)
rotate disk(s) to level rail
Fig 7
©2018 DreamLine. All Rights Reserved
12ENIGMA-XO manual Ver 1 Rev 2 03/2018
Page 15
ATTENTION:
This step shows the Small Stationary Glass (#23) installation for the 72” model only
(not included with the 60” model).
rotate disk(s) to level rail
7. If installing the 72” model:
Unscrew the disk from the Small Stationary Glass Bracket (#21) and loosen the set screw that secures the bracket to the Guide Rail. If necessary, slide the Door Stopper (#01) away from the area so that it will not interfere with the placement of the Small Stationary Glass (#23). Position the Small Stationary Glass (#23) onto the threshold and butt it up against the wall. Align the Small Stationary Glass Bracket (#21) with the hole in the Small Stationary Glass (#23),
re-attach the outer disk and secure the Small
Stationary Glass Bracket (#21) to the Upper Guide Rail for 72” (#24). (Fig 8a and 8b)
Fig 8a
Fig 8b
1
3
2
4
©2018 DreamLine. All Rights Reserved
13ENIGMA-XO manual Ver 1 Rev 2 03/2018
Page 16
8. Once the Upper Guide Rail (#03) is level, mark the position of the Wall Bracket (#19) and Guide
Rail Brackets (#08) on the wall. *NOTE:
wall for the Small Stationary Panel Glass (#23) (see Fig 9.4*). (Fig 9)
If installing the 72” model, also mark the position of the Wall Bracket (#19) on the opposite
1 2 3
inside
4*
for 72” model
inside
Fig 9
9. Make sure that the Stationary Glass (#02) is parallel to the front edge of the threshold and mark it.
Slide the Guide Block (#12) into the notch of the Stationary Glass (#02), and align flush with the edge (Fig 10a). Mark its position and also mark the hole for drilling using a pencil (or center punch.)
Note: If installing the 72” model, also position the Small Stationary Glass Bottom Bracket (#22) with the edge of the Small Stationary Glass (#23) (Fig 10b) and mark its position and the hole for drilling.
(Fig 10a and 10b)
Fig 10a
Fig 10b
for 72” model
©2018 DreamLine. All Rights Reserved
14ENIGMA-XO manual Ver 1 Rev 2 03/2018
Page 17
10. After marking the positions of all the hardware, set the
Stationary Glass (#02) with the Upper Guide Rail (#03) aside.
(If installing the 72” model, also remove the Small Stationary Panel Glass (#23) from the Upper Guide Rail (#03)).
Remove the Guide Rail Brackets (#08) from the Upper Guide Rail (#03) and the Wall Bracket (#19) from the Stationary Glass (#02). Place the Wall Bracket (#19) and Guide Rail Brackets (#08) back to the outlined positions and mark the
holes for drilling.
*NOTE: If installing the 72” model, perform the same procedure on the opposite wall to mark the Wall Bracket (#19) for the Small Stationary Panel Glass (#23) (see Fig 11.4*).
(Fig 11)
sleeve
1 2
3
Fig 11
1 2
Ø5/16 (8mm)
for 72” model
4*
Separate the Guide Rail Bracket (#08) sleeve from the base by loosening the set screws (leave the sleeves on both ends of the upper guide rail)
base
!
**NOTE: Step #11 has an option for installing the guide rail brackets to the wall using anchors. However, the manufacturer strongly recommends installing these heavy doors to the studs or to pre-installed 2”x 6“ wood reinforcements behind the wall in the area where the guide rail brackets will be attached to the wall.
**For the recommended installation into a stud, drill a Ø1/4” hole up to the stud, do not use wall anchors, and let the screw bore into the wood.
11. Drill a hole for the Wall Bracket (#19) using a Ø5/16”
(8mm) drill bit and insert the Wall Anchor (#9b) (see Fig. 12.1 and 12.2). For the 72“ model, repeat this step for the Wall Bracket (#19)
for the Small Stationary Panel Glass (#23). (Fig 12.7 and 12.8)
Drill the holes for the Guide Rail Brackets (#08) using a Ø3/8” (10mm) drill bit and insert the Wall Anchors (#9a). (see Fig. 12.3**~ 12.6**).
3**
Ø3/8 (10mm)
see Note
4**
5** 6**
7 8
Ø5/16 (8mm)
Ø3/8 (10mm)
see Note
for 72” modelfor 72” model
**If installing into a stud (recommended), drill a Ø1/4” hole and do not use the wall anchors (see note above). (Fig 12)
Fig 12
©2018 DreamLine. All Rights Reserved
15ENIGMA-XO manual Ver 1 Rev 2 03/2018
Page 18
12. Fasten the Wall Bracket (#19) to the wall using the ST4.2×55 Truss Head Screw (#18). (Fig 13.1)
If installing the 72” model, repeat this step to install the Wall Bracket (#19) for the Small Stationary Panel Glass (#23) (Fig 13.4).
Install the base parts of the Guide Rail Brackets (#08) onto both walls using the ST6×55 Large Truss Head Screw (#10). Note that the adjustment set screws must be aligned vertically for easier access to
adjust for level if necessary after the glass is installed. Align the set screws vertically and tighten. (Fig 13)
1 2 3 4*
Fig 13
13a. To install Guide Block (#12): Loosen the set screw and
remove the guide block face plate (Fig 14a.5). Apply silicone to the underside of the Guide Block (#12) and screw the Guide
Block (#12) to the threshold as described below:
*NOTE:
For installation into an Acrylic Threshold: drill a Ø1/8”(3mm) hole and use the ST4.2 x 40mm
Countersunk Screw (#17) OR
For installation into a Tile Threshold: drill a Ø5/16”(8mm) hole, install a Wall Anchor 5/16” (#09b) and use the ST4.2 x 40mm Countersunk Screw (#17).
use a pencil or
1
a center-punch to mark the hole
only use anchor
**
with tile threshold
3
for 72” model
2
*see note
4
The Guide Block (#12) must be screwed down. (Fig 14a)
ST4.2 X 40
overhead view of threshold & guide block
M5 X 10
Guide Block must be installed square to the plane of the glass
Part#12 - Guide Block (with caps)
5
Fig 14a
©2018 DreamLine. All Rights Reserved
16ENIGMA-XO manual Ver 1 Rev 2 03/2018
Page 19
13b. If installing the 72” model, repeat Step #13a for the
Small Stationary Glass Bottom Bracket (#22). Loosen the
set screw and remove the Guide Block Face Plate.
use a pencil or a
1
center-punch to mark the hole
2
*NOTE:
For installation into an Acrylic Threshold: drill an Ø1/8”(3mm) hole and use the ST4.2 x 40mm
Countersunk Screw (#17) OR
For installation into a Tile Threshold: drill a Ø5/16”(8mm) hole and use the ST4.2 x 40mm
Countersunk Screw (#17) (with Anchor (#09b) for tile)
Apply silicone to the underside of the Guide Block (#12) and screw the Guide Block (#12) to the threshold. (Fig 14b)
The Small Stationary Glass Bottom Bracket (#22) must be screwed down.
ST4.2 X 40
3
** use anchor with tile threshold
5
*see note
4
Fig 14b
M5 X 10
Part#22 - Small Stationary Glass Bottom Bracket
!
NOTE: Before you install the Stationary Glass (#02), take
the Door Glass (#05) into the shower area and lean it against the wall with the handle holes on the correct side. After the Stationary Glass (#02) is installed, it may not be possible to easily get the door glass into the shower. Always use padding to protect the glass and shower surfaces.
NOTE: DO NOT attach the handle to the door glass until instructed to do so. DO NOT attempt to lift the door glass with the handle as this may result in damage to the glass and/or serious personal injury. Use a professional grade glass suction cup and an assistant.
protective padding
protective padding
©2018 DreamLine. All Rights Reserved
17ENIGMA-XO manual Ver 1 Rev 2 03/2018
Page 20
14. Re-position the Stationary Glass (#02) and Upper Guide
Rail (#03) onto the threshold and fasten both sleeves of the Guide Rail Brackets (#08) to the brackets on the walls.
Tighten the set screws on the Guide Rail Brackets (#08) to secure the Upper Guide Rail (#03). Position the bracket set screws so that they are accessible from the top and bottom (Fig 15.1 and 15.2).
Assemble the Wall Bracket (#19) at the bottom corner of the Stationary Glass (#02). For the 72“ model, repeat this step for the Wall Bracket (#19) for the Small Stationary Panel Glass (#23) (Fig 15.4) Use the clear vinyl gasket between the glass and the metal parts to avoid contact with the glass, then tighten the bolt with the supplied allen wrench. (Fig 15)
1
3
2
4
for 72” model
TIP: Adjust the installed Upper Guide Rail (#03) to level as necessary using the Guide Rail Brackets (#08) first and then the Glass Brackets (#07). Start adjustments from the door end.
Panel end
Glass bracket
(Right hand door installation shown as example)
Door end
Guide Rail Bracket
outside
outside
Fig 15
Lower guide rail Raise guide rail
Glass Bracket adjustments
NOTE: Use the Guide Rail Bracket (#08) set screws to adjust the Guide Rail (#03) to level.
To lower the rail:
Loosen the top set screw and tighten the bottom set screw.
To raise the rail:
Loosen the bottom set screw and tighten the top set screw.
©2018 DreamLine. All Rights Reserved
18ENIGMA-XO manual Ver 1 Rev 2 03/2018
Page 21
15a. For the 48”or 60“ model size: Measure the
distance from the edge of the Guide Block (#12) to the wall. This distance will be “X”. Use a miter saw or a hacksaw to cut the
Anti-Splash Guard (#15) to the size of: (X) + 3/8”. (Fig 15a)
15b. For the 72” model size: Measure the
distance between the edge of the Guide Block (#12) to the Small Stationary Glass Bottom Bracket (#22). This distance will be “L”.
Use a miter saw or a hacksaw to cut the
Anti-Splash Guard (#15) to the size of: (L) + 3/4”. (Fig 15b)
for 48”or 60“ model
X
X + 3/8”
measure the distance ‘X’ from the guide block to the wall and add 3/8”
for 72” model
L
L + 3/4 ”
measure the distance ‘L’ between the guide blocks and add 3/4”
Fig 15a Fig 15b
16. Apply silicone to the bottom of the Anti-Splash Guard (#15). Insert one end of the
Anti-Splash Guard (#15) into the Guide Block (#12).
Align the Anti-Splash Guard (#15) parallel with the front edge of the shower base or threshold.
Cover the other end of the Anti-Splash Guard (#15) with the Anti-Splash Guard Cap (#16) against the wall (48” and 60” models) (see Fig 16.4). (Fig 16)
For the 72” model: Insert the Anti-Splash Guard (#15) into the Small Stationary Glass
Bottom Bracket (#22). (Fig 16.5)
1 42 3
for 48” & 60” model
only use cap when installing up to a wall
5*
for 72” model
Fig 16
©2018 DreamLine. All Rights Reserved
19 ENIGMA-XO manual Ver 1 Rev 2 03/2018
Page 22
17. Secure the Anti-Splash Guard (#15) to the threshold with several pieces of painter’s tape to hold it
in position and tight to the threshold until the silicone fully cures. (Fig 17)
Fig 17
18. Attach the Guide block face plate to the installed
Guide Block (#12) and tighten the set screw with the
supplied allen wrench. Use the supplied Decorative caps to cover the screw holes. (Fig 18)
face plate
Fig 18
©2018 DreamLine. All Rights Reserved
20ENIGMA-XO manual Ver 1 Rev 2 03/2018
Page 23
19. If installing the 72” model: attach the Small Stationary Panel Glass (#23) to the Upper Guide
Rail (#03) using the Small Stationary Glass Bracket (#21).
Attach the face plate to the Wall Bracket (#19) on the threshold (see Fig 19.5). (Fig 19)
1 2
20. If installing the 72” model: Attach the
Guide block face plate to the installed Small Stationary Glass Bottom Bracket (#22) and
tighten the set screw with the supplied allen wrench. Make sure that the clear gaskets are in place to protect the glass. Use the supplied Decorative caps to cover the screw holes. (Fig 20)
Fig 19
3
4
5
outside
clear gasket
face plate
Fig 20
©2018 DreamLine. All Rights Reserved
21ENIGMA-XO manual Ver 1 Rev 2 03/2018
Page 24
NOTE: DO NOT attach the handle to the door glass until instructed to do so. DO NOT attempt to lift the door glass with the handle as
!
this may result in damage to the glass and/or serious personal injury.
21. Attach two of the Rollers (#04) into the top holes on the
Door Glass (#05) with the wheels facing outside of the shower. Apply Thread Lock Adhesive (#26) to the bolts and safety set screws. Align the safety set screw towards the top for easier access to retighten after installation. (See Fig 21 and page 30 for details)
Lift the door and position the Rollers (#04) onto the Upper Guide Rail (#03) while carefully sliding the bottom edge of the Door Glass (#05) into the groove of the Guide Block (#12).
If necessary, adjust the disks on both Rollers (#04) to ensure that the bottom edge of the Door Glass (#05) does not touch the bottom of the Guide Block (#12) (see details regarding
adjustment on page 28). (Fig 21 and 22)
safety set screw
1 2
outside
3
safety set screw
5
4
Note: The adjustment disks in the wheels are the same as the disks in the Glass brackets and can be rotated to adjust the door glass to create a seal with the wall. See detailed
description on page 28.
!
TIP: Mark the location of the
high spot on the outer surface of the adjustment disk with a felt tip pen to make adjustment easier to see.
TIP: Use a 3/16” shim beneath the door glass when adjusting the level of the door so that the glass does not make contact with the guide block.
Raise Door glassLower Door glass
Roller wheel adjustment disks
22. Attach two Rollers (#04) into the holes in the Door
Glass (#05) beneath the Upper Guide Rail (#03). Adjust these Rollers (#04) to make conatct with the Upper Guide Rail (#03). Apply Thread Lock Adhesive (#26) to the bolts and safety set screws. Align the safety set screw towards the bottom for easier access to retighten after installation. (Fig 22)
inside
Fig 21
1 2
!
add threadlock to
the safety set screw
and wheel bolt
Upper Guide Rail
front view
side view
3
4
safety set screw
Fig 22
©2018 DreamLine. All Rights Reserved
22ENIGMA-XO manual Ver 1 Rev 2 03/2018
Page 25
add threadlock to
the safety set screw
and wheel bolt
NOTE: The Safety set screw on both wheels MUST BE
re-tightened after installation to prevent the large bolt
!
from coming loose. Apply thread lock during installation.
(See details Fig 23 and also on Page 28)
23. Press the Anti-Water Strip (#14) onto the vertical edge
of the Stationary Glass (#02) and the Door Glass (#05) (Fig 24.1). Press the Bumper Strip (#13) onto the vertical edge of the Door Glass (#05) (48” and 60“ model). (Fig 24.2)
For the 72” model: Attach Anti-Water Strip (#14) to the edge of the Small Stationary Glass (#23). The Bumper Strip (#13) is not necessary with the 72” model (Fig 24.3*).
Attach the Handle (#06) to the Door Glass (#05). (Fig 24)
Note: Use a razor knife to trim the Anti-Water Strip (#14) at
the top to avoid interfering with the lower Rollers (#04).
Fig 23
1
inline panel
3*
door
inside
72” model
small panel
door
48”or 60”
2
model
door
wall
4
outside
(Right hand door installation shown as an example)
Fig 24
©2018 DreamLine. All Rights Reserved
23ENIGMA-XO manual Ver 1 Rev 2 03/2018
Page 26
24. Position the Door Stoppers (#01) and screw
them tightly to the Upper Guide Rail (#03).
!
NOTE: The Door Stoppers (#01) must be
positioned correctly to prevent the handle from contacting the Stationary Glass (#02) (48”, 60” & 72“ models) and to stop the
wall
Door Glass (#05) in a position that allows the bumper strip to create a seal with the wall, but does not allow the door glass to bang into the wall during normal operation (48” & 60” models).
(Fig 24a 24b)
*For the 72” model: Install the door side stopper in a position to
prevent the handle from making contact with the small inline panel glass when the door is in the closed position. (Fig 24b.7)
Fig 24a
door side of opening 48” and 60” models
(+/- 1/8”)
3”
approximately
Door Stopper Installation:
1. Remove the set screw
2. Slide the Door Stopper (#01) onto the Upper Guide Rail (#03)
3. Align with stopper hole (stationary panel side only)
4. Apply Thread Lock Adhesive (#26) to the set screw threads
5. Tighten screw into the stopper hole (stationary panel side only)
6. Correctly position the door side stopper and tighten the set screw with Thread Lock Adhesive (#26)
(Fig. 24b)
Stopper
1
Panel side
Stopper
5
hole
2
Thread Lock
6
Note: If installing
3
Door side
Stopper (#01)
4
Thread
Lock
7*
the 72” model, position the door-side stopper so that the handle cannot make contact with the small inline panel glass
position stopper to allow enough clearance for the handle
small
panel
when the door is in the closed position.
!
(ENIGMA-XO Right hand door installation shown as an example)
Fig 24b
72” model with Right hand door installation
©2018 DreamLine. All Rights Reserved
24ENIGMA-XO manual Ver 1 Rev 2 03/2018
Page 27
25. Install the Bumper (#30) with the 3M tape: postion the Bumper (#30) onto the threshold and
against the wall on the stationary panel side of the installation. (For 72” model, this will be the side of the opening with the large stationary panel). Remove the 3M Tape backing and position the Bumper
(#30) onto the threshold against the Wall Bracket (#19). (Fig 25)
TIP: Install the Bumper (#30) using the 3M
NOTE: The surfaces need to be clean and free of construction debris before installing the bumper. Wipe the area with an alcohol swab before installation
tape. Screwing the bumper to the wall using a 5/16” hole and anchor is optional (see step #26).
The Bumper (#30) is reversible for Left (as shown below from inside the shower) or Right wall installation
Door
Panel
1
2
180
3M Tape
º
Inside
ENIGMA-XO manual Ver 1 Rev 2 03/2018
Inside
3
Inside
Fig 25
©2018 DreamLine. All Rights Reserved
25
Page 28
26. To install the Bumper (#30) with the screw method, position the bumper (#30) onto the
threshold and against the wall on the stationary panel side of the installation. (For 72” model, this will be the side of the opening with the large stationary panel). and mark the position of the hole onto the wall. Drill a 5/16” hole and insert the anchor (###). Remove the 3M Tape and position the Bumper (#30) onto the threshold against the Wall Bracket (#19) and attach using the ST4.2 x 40 Countersunk screw.
(Fig 26)
NOTE: The surfaces need to be clean and free of construction debris before installing the bumper. Wipe the area with an alcohol swab before installation
Door
Panel
TIP: Use caution if using the screw method
to not crack the wall/tile and to avoid any plumbing behind the wall.
The Bumper (#30) is reversible for Left (as shown below from inside the shower) or Right wall installation
1 2
3 4
3M TAPE
4a
ENIGMA-XO manual Ver 1 Rev 2 03/2018
Inside
4b
5
6
4c
7
Fig 26
©2018 DreamLine. All Rights Reserved
26
Page 29
27. Apply a good quality mildew-resistant silicone along the interior perimeter where the glass meets
the wall and threshold and also along the Anti-Splash Guard (#15). (Fig 26)
Please allow 24 hours for the silicone to fully cure before using the shower.
24
Hours
Fig 27
!
Do Not hang or drape a towel or wash
cloth over the guide rail as this may cause the roller wheels to get stuck and possibly cause serious damage or injury.
ENIGMA-XO manual Ver 1 Rev 2 03/2018
©2018 DreamLine. All Rights Reserved
27
Page 30
Roller adjustment procedure for Enigma, Enigma-X and Enigma-XO
The bushing that goes through
Insert a small tool (like an
you reghten the big bolt.
Once you have loosened the
This is the adjustment disk.
2
3
4 4a
To achieve minimal clearance beneath the door glass without making contact with the boom
guide block and creang a good seal with the wall.
Have at least two 3/16” shims or wedge shims (to maintain space beneath the door glass) and an assistant available to help with this procedure.
Adjust only one wheel at a me and you may need to perform these steps more than once to
get the desired results.
Cauon: The door glass is heavy and may require two people to safely accomplish these steps.
1. the -X) orFirst, loosen and lower either Roller Guards (Enigma Boom Rollers (Enigma, Enigma-XO) to allow
enough room to adjust the upper rollers. (If you have not installed these yet, you will be instructed to in step #7 aer these adjustments are made)
2. Loosen the safety set screw on the roller. (See note 2 below)
3. Loos
en the big bolt just enough so that you can rotate the adjustment disk. (See note 3 below)
4. Rotate the adjustment disk to raise or lower the door slightly with help from an assistant. You can use a small tool (like an allen wrench) to aid in turning this disk by inserng it into the small hole on the edge of the adjustment disk. (see note 4 & 4a below)
5. While holding the adjustment disk in p
lace, reghten the big bolt. Use a shim or have an assistant hold
the door glass in place while you reghten the big bolt.
6. Re-ghten the safety set screw to hold the big bolt in place (see note 5). Test the operaon of the door.
7. For the Enigma-X:Reposion the rollerguards approximately 1/16” beneath the guide rail and
reghten. For the Enigma/Enigma-XO: adjust the lower rollers to make contact with the rail in the same
manner as th
Loosen this safety set screw rst. This holds the big bolt in place and must be re-ghtened aer the roller is adjusted.
Posion this set screw at
the top for easier access.
5
It is extremely important that the safety set screw is re-tightened to secure the big bolt.
e upper rollers.
During installaon onto the glass,
rotate this disk so that the safety set screw is at the top for easier access
set screw, you will be able to loosen this big bolt just enough to allow you to rotate the adjustment disk.
Once the big bolt is loosened, rotate this disk to raise or lower the door glass slightly. Use cauon so that the door glass does not make contact with the guide block.
!
add threadlock to
the safety set screw
and wheel bolt
ENIGMA-XO manual Ver 1 Rev 2 03/2018
the glass is ellipcal and
allows you to raise or lower
the glass when you rotate the
adjustment disk.
allen wrench) into this hole to help rotate this adjustment disk and also to hold the disk in place when
©2018 DreamLine. All Rights Reserved
28
Page 31
Product Maintenance
BASES and BACKWALLS: To ensure long lasting life for your acrylic back walls: wipe them off after each use with a soft cloth. To clean the acrylic back walls use non-abrasive sprays or cream based cleaners. Avoid the use of aerosol spray cleaners. Never use abrasive cleansers, metal brushes or scrapers that could scratch or dull the surface.
GLASS: To ensure long lasting life for your glass shower products: wipe them off after each use with a soft cloth. Rinse and wipe off the glass using either a soft cloth or a squeegee to prevent soap buildup and water spots (Hard water can etch the surface of the glass over time if left to dry). To prevent scratching the surface: never use abrasive cleaners or cleaning products that contain scouring agents. Never use bristle brushes or abrasive sponges that may scratch the surface.
HARDWARE: To ensure a long lasting finish: wipe off the metal parts after each use with a soft cloth. Do not use abrasive cleaners or cleaning products containing ammonia, bleach or acid. If accidentally used, rinse the surface as soon as possible to prevent damage to the finish (peeling or corrosion). After cleaning the polished finishes, rinse thoroughly and wipe dry with a soft cloth. Clean stainless steel surfaces at least once a week. When applying stainless steel cleaner or polish to stainless steel hardware, work with (not across) the grain. Never use an abrasive sponge or cloth, steel wool or wired brush as these may permanently scratch the surfaces.
NOTE: To maximize the life of your door, it is important to regularly inspect the glass and other hardware for misalignment, proper attachment, and/or damage. Contact DreamLine
Enigma-XO Maintenance checklist
Guide rail level and tight ◻ Guide rail brackets tight to the walls
o All set screws tight
Panel glass secure ◻ Panel glass brackets tight ◻ Guide block square to the threshold and glass ◻ Proper clearance beneath the door glass between the threshold and within the guide block ◻ Door Glass adjusted so that the Bulb vinyl seal makes even contact with the wall ◻ Wheel assemblies tight
o Wheel roller bolts tight o Wheel assembly safety set screws tight and accessible Stoppers tight and positioned correctly o Panel-side stopper installed into the pre-drilled hole in the guide rail o Adequate Handle clearance when the door is fully open o Door-side stopper positioned at approximately 3” (+/- 1/8”) (as measured from the wall to the center of the stopper)
◻ Stopper stops the door and bulb vinyl seals to the wall ◻ SafeStop bumper secure to the wall ◻ Bottom Rollers should make contact with the guide rail. ◻ Remove vinyl seals to inspect the edges of the door glass for concealed damage
o Damaged glass must be replaced! Replace damaged or missing vinyl seals
®
with any questions or concerns.
©2018 DreamLine. All Rights Reserved
29ENIGMA-XO manual Ver 1 Rev 2 03/2018
Page 32
For more information on DreamLine
TEL: 866-731-2244
FAX: 866-857-3638
DREAMLINE.COM
®
Shower Doors and Enclosures please visit DreamLine.com
©2018 DreamLine. All Rights Reserved
Loading...