DreamLine SHDR-3448580-EX-04 User Manual

1
AQUA SERIES TUB EX/RT
TUB DOOR GLASS PANEL INSTALLATION INSTRUCTIONS
Configuration 2
with Extender Panel
Configuration 3
with Return Panel
ATTENTION:
Please see the Shower / Tub Door Installation manual included in the door packaging for complete tub door installation instructions.
MODEL: __________ STYLE: __________ SELECTOR: __________
Please choose your door model, style and selector according to your order for easy installation.
IMPORTANT
DreamLineTM reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical drawings, manuals or any other details please refer to the support.BathAuthority.com web page.
Please read these instructions carefully before installing. If you have any questions regarding
installation, please call our technical support specialists Monday through Friday 9:00 AM – 5:00
PM EST at Phone: 1-866-731-2244, Fax: 1-866-227-1533 or e-mail our technical support group
at
support@BathAuthority.com.
For more information on DreamLineTM Shower Doors and Enclosure please visit www.BathAuthority.com
AQUA SERIES TUB EX/RT”, PANEL Rev.1 Ver.1 06/2014
2
Preparation
Caulk
Tape Measure Pencil
Screwdriver
Phillips Drill bit
Level
Gun
Caulk
Drill
Electric
Hammer
Drill bit
(Ø=5/16")
(Ø=1/8")
Mallet Wood
1. After opening all boxes and packages, read this introduction carefully. Check that all of the needed
parts are included in the package by marking all the components on the Detailed Diagram of Glass Panel Components”. Examine boxes and packages for shipping damage. If the unit has been damaged, has a finishing defect, or has missing parts, please contact our customer support department within 5 business days of the delivery date. Please note that DreamLineTM will not
replace any damaged products or missing parts free of charge after 5 business days or if the product has been installed. Feel free to contact DreamLineTM if you have any questions.
2. Please note that you should consult your local building codes with questions on installation
compliance standards. Building and plumbing codes may vary by location, and DreamLine is not responsible for code compliance standards for your project and will not accept any returns.
3. If this unit is going to be installed in new construction, please install all of the required plumbing
and drainage before installing the shower. Use a competent and licensed (if required by local code) plumber for all plumbing installation.
4. Prior to the installation, please ensure that the installation surface is level and solid and will be
able to support the total weight of the unit. Also make sure that the walls are plumb. Depending on the type of unit you are installing, some adjustments in leveling may be possible. However, irregular installation, surface level or out of square conditions can result in serious problems for your installation. Please note that some adjustments and drilling may be necessary. Please protect all primary surfaces of the product during installation. Never set your glass down directly onto a tile floor. Always use a piece of wood or cardboard to protect the bottom edge and corners of the glass.
5. Note: The installation of this unit requires that you drill down into the tub.
Tools Required
AQUA SERIES TUB EX/RT”, PANEL Rev.1 Ver.1 06/2014
3
Diagram A
01
U-channel 1 (wall profile)
1pc
08
Countersunk screw ST4.2x40
4pcs
02
U-channel 2 (bottom profile)
1pc
10
Countersunk screw ST4.2x25
2pcs
07
Ø5/16” Wall anchor
4pcs
16
Extender panel glass
1pc
Diagram B
01
U-channel 1 wall profile)
1pc
08
Countersunk screw ST4.2x40
4pcs
02
U-channel 2 (bottom profile)
1pc
10
Countersunk screw ST4.2x25
2pcs
07
Ø5/16” Wall anchor
4pcs
17
Return panel glass
1pc
Detailed Diagram of Glass Panel Components
Packing List
NOTE: Unpack your unit carefully and inspect it. Lay it out and identify all parts using the detailed
diagram and packing list in your manual as a reference. Before discarding the carton, check for small hardware bags that tend to fall to the bottom of the box. If any parts are damaged or missing, please contact DreamLineTM for replacement. The shipping boxes may contain extra parts not used in your model configuration.
AQUA SERIES TUB EX/RT”, PANEL Rev.1 Ver.1 06/2014
4
Align the Extender glass with the Door
inside
Extender glass
U-channel 1
U-channel 2
inside
outside
Door
Extender glass
Door
inside
wall
wall
inside
outside
inside
wall
1
3 5 2
4
6
Fig. 1
Configuration 2: 9” In-Line Extender Panel Installation
NOTE: The following installation instructions apply to all of the Aqua series tub doors. Please install whichever Aqua model you purchased prior to proceeding with the following Stationary Glass installation instructions. Please see the Shower / Tub Door Installation manual included in the door packaging for complete tub door installation instructions.
NOTE: The Standard Aqua Hinged Tub Door is the example shown throughout this installation manual.
NOTE: Use parts from Diagram “A” for the glass panel assembly and installation.
1. Slip the U-channel 2 (bottom profile) (02) and U-
channel 1 (wall profile) (01) onto the Extender panel glass (16) in the shown locations.
With the door open, place the Extender panel glass onto the middle of the tub ledge ensuring that the U- channel 1 (wall profile) (01) is flush with the wall. Close the Glass Door and align the Extender panel glass to it. Ensure that the Extender panel glass is precisely in line with Door and level vertically. Outline the position of the Extender panel glass along the inside edge of both U-channels on the wall and tub ledge.
See Fig. 1 for details.
AQUA SERIES TUB EX/RT”, PANEL Rev.1 Ver.1 06/2014
5
U-channel 1
U-channel 2
outside
inside
wall
Fig. 2
1 3 5
2 4 6
Ø1/8”
Fig. 3
waterproof silicone
2. Remove the U-channel 1 (wall profile) (01) and U-
channel 2 (bottom profile) (02) from the Extender panel glass (16) and carefully set the Extender glass
aside. Place the U-Channel 2 (bottom profile) onto the tub ledge in line with the inside
U-channel
mark.
Mark the drill holes on the tub ledge through the predrilled holes in the U-Channel 2 and drill the holes using Ø1/8” drill bit.
Apply waterproof silicone along the bottom surface and around the holes of the U- Channel 2 and fasten it to the tub ledge with the Countersunk screws
ST4.2×25 (10).
NOTE: The surface needs to be clean and free of debris before applying silicone.
See Fig. 2 & 3 for details
AQUA SERIES TUB EX/RT”, PANEL Rev.1 Ver.1 06/2014