Drazice AIR 2, 6 kW, AIR 3, 5 kW, AIR 5 Operating And Installation Manual

...
OPERATING AND
INSTALLATION MANUAL
OUTDOOR UNIT
AIR 2,6 kW AIR 3,5 kW AIR 5,3 kW
Družstevní závody Dražice-strojírna s.r.o. Dražice 69, 294 71 Benátky nad Jizerou tel.: +420 / 326 370 911 fax: +420 / 326 370 980 e-mail: export@dzd.cz
CAREFULLY READ THIS MANUAL BEFORE INSTALLING!
Dear Customer, The Works Cooperative of Dražice - Machine Plant, Ltd., would like to thank you for your decision to use a product of our brand.
The product is not intended to be controlled by a) people (including children) with reduced physical, sensual or mental capacities, or b) people with insufficient knowledge and experiences unless supervised by responsible person,
or unless properly instructed by such responsible person.
CONTENTS
Safety instructions
Preparation before use
Safety Precautions
Installation instruction
Installation diagram
Select the installation locations Connecting of the cable 16 Wiring diagram
Outdoor unit installation
Air purging
Please read this use and installation instructions carefully before installing and using this appliance and keep this manual for future reference.
Caution: Risk of fire / flammable materials
WARNING: Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
3
4
5
14 14 15
17 18
18
Safety instructions
To guarantee the unit work normally, please read the manual carefully before
installation, and try to install strictly according to this manual.
Do not let air enter the refrigeration system or discharge refrigerant when moving the
air conditioner.
Properly ground the air conditioner into the earth.
Check the connecting cables and pipes carefully, make sure they are correct and firm
before connecting the power of the air conditioner.
There must be an air-break switch.
After installing, the consumer must operate the air conditioner correctly according
to this manual, keep a suitable storage for maintenance and moving of the air
conditioner in the future.
Fuse of indoor unit: T 3.15A 250VAC.
For 2,6 kW~3,5 kW models, fuse of outdoor unit: T 15A 250VAC.
For 5,3kW models, fuse of outdoor unit: T 20A 250VAC
The installation instructions for appliances that are intended to be permanently
connected to fixed wiring and have a leakage current that may exceed 10 mA, shall state that the installation of a residual current device (RCD) having a rated residual operating current not exceeding 30 mA is advisable.
Warning: Risk of electric shock can cause injury or death: Disconnect all remote
electric power supplies before servicing.
The maximum length of the connecting pipe between the indoor unit and outdoor unit
should be less than 5 meters. It will affect the efficiency of the air conditioner if the distance longer than that length.
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
The batteries in remote controller must be recycled or disposed of properly. Disposal
of Scrap Batteries - Please discard the batteries as sorted municipal waste at the accessible collection point.
If the appliance is fixed wiring, the appliance must be fitted with means
for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under over voltage category III conditions, and these means must be incorporated in the fixed wiring in accordance with the wiring rules. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons to avoid a hazard.
The appliance shall be installed in accordance with national wiring regulations.
Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
The appliance shall not be installed in the laundry.
- 3 -
Preparation before use
Note
Preset
Safeguarding the environment
For the multi system, the refrigerant refers to the multi outdoor unit.
When charging refrigerant into the system, make sure to charge in liquid state,
if the refrigerant of the appliance is R32.Otherwise, chemical composition of refrigerant (R32) inside the system may change and thus affect performance of the air conditioner.
According to the character of refrigerant (R32, the value of GWP is 675), the pressure
of the tube is very high, so be sure to be careful when you install and repair the appliance.
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons to avoid a hazard.
Installation of this product must be done by experienced service technicians’
professional installers only in accordance with this manual.
The temperature of refrigerant circuit will be high, please keep the interconnection
cable away from the copper tube.
Before using the air conditioner, be sure to check and preset the following.
Remote Control presetting
Each time after the remote control is replaced with new batteries or is energized, remote control auto presetting
heat pump. If the air conditioner you purchased is a Cooling Only one, heat pump remote controller can also be used.
Back-light function of Remote Control (optional)
Hold down any button on remote control to activate the back light. It automatically shuts off 10 seconds later.
Note: Back-light is an optional function.
Auto Restart Presetting
The air conditioner has an Auto-Restart function.
This appliance is made of recyclable or re-usable material. Scrapping must be carried out in compliance with local waste disposal regulations. Before scrapping it, make sure to cut off the mains cord so that the appliance cannot be re-used. For more detailed information on handling and recycling this product, contact your local authorities who deal with the separate collection of rubbish or the shop where you bought the appliance.
SCRAPPING OF APPLIANCE
This appliance is marked according to the European Directive 2012/19/EC, Waste Electrical and Electronic Equipment (WEEE). This marking indicates that this product should not be disposed
with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal,recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmentally safe recycling.
- 4 -
OFF
Safety precautions

Symbols in this Use and Care Manual are interpreted as shown below.

Be sure not to do.
Pay attention to such a situation.
Grounding is essential.
Warning: Incorrect handling could cause a serious hazard, such as death, serious injury, etc.
Use correct power supply in accordance with the rating plate requirement. Otherwise, serious faults or hazard may occur, or a fire maybe break out.
ON
Keep the power supply circuit breaker or plug from dirt. Connect the power supply cord to it firmly and correctly, lest an electric shock or a fire break out due to insufficient contact.
ON
OFF
Do not use the power supply circuit breaker or pull off the plug to turn it off during operation. This may cause a fire due to spark, etc.
It is harmful to your health if the cool air reaches you for a long time. It is advisable to let the air flow be deflected to all the room.
Prevent the air flow from reaching the gas burners and stove.
Do not touch the operation buttons when your hands are wet.
Never insert a stick or similar obstacle to the unit. Since the fan rotates at high speed, this may cause an injury.
Do not repair the appliance by yourself. If this is done incorrectly, it may cause an electric shock, etc.
Do not put any objects on the outdoor unit.
It is the user's responsibility to make the appliance be grounded according to local codes or ordinances by a licenced technician.
ON
OFF
SMART MODE
TEMP.
SUPER
TEMP.
FEEL SLEEP
CLOCK TIMER ON TIMER O FF
QUI ET DIM MER ECONOM Y
FAN SPEED
Turn off the appliance by remote control firstly before cutting off power supply if malfunction occurs.
- 5 -
Do not knit, pull or press the power supply cord, lest the power supply cord be broken. An electric shock or fire is probably caused by a broken power supply cord.

Precautions for using R32 refrigerant

The basic installation work procedures are the same as the conventional refrigerant
(R22 or R410A). However, pay attention to the following points:
1.

Transport of equipment containing flammable refrigerants

Compliance with the transport regulations
2.

Marking of equipment using signs

Compliance with local regulations
3.

Disposal of equipment using flammable refrigerants

Compliance with national regulations
4.

Storage of equipment/appliances

The storage of equipment should be in accordance with the manufacturer's instructions.
5.

Storage of packed (unsold) equipment

Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations.
6.

Information on servicing

6-1
Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
6-2

Work procedure

Work shall be undertaken under a controlled procedure to minimize the risk of flammable gas or vapor being present while the work is being performed.
6-3

General work area

All maintenance staff and others working in the local area shall be instructed
on the nature of work being carried out. Work in confined spaces shall be avoided.
The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.
6-4

Checking for presence of refrigerant

The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.