Drayton LP111Si, LP522Si, LP722Si, SINGLECHANNEL, LP231Si Installation Instructions Manual

...
1
Drayton
Drayton Lifestyle
Switchmaster
ACL
Drayton Switchmaster
Randall Danfoss Randall Danfoss Randall Danfoss Randall Danfoss Randall Danfoss Randall Danfoss Randall Grasslin Towerchron Grasslin Towerchron
Honeywell
Honeywell Horstmann
Horstmann Horstmann
Horstmann
L
andis&Staefa Landis&Staefa Landis&Staefa
Potterton Myson
Sangamo
DUAL
CHANNEL
LP241Si,LP522Si,LP722Si
SINGLE
CHANNEL
SINGLE
CHANNEL
Timeswitch
DUAL
CHANNEL
Programmer
for heating OR hot water
LP111Si, LP711Si
Technical Helpline: 0333 7000622
Email: customer.care@draytoncontrols.co.uk
Web: www.draytoncontrols.co.uk
SERVICE INTERVAL
for heating AND hot water
Installation Instructions
06490050001 ISS F
TIMESWITCH TERMINAL COMPARISONS
MAKE MODEL
Lifestyle
Installer note: After installation, tear along perforations indicated and retain this section - only leave the User instructions with the end user
Salus
Myson
Myson
British Gas
Drayton
Drayton
Drayton
2
INSTALLATIONINSTRUCTIONS
PLEASE NOTE: INSTALLATION MUST ONLY BE CARRIED OUT BY A QUALIFIED ELECTRICIAN OR HEATING ENGINEER.
MAKE SURE MAINS INPUT HASA3AMP FUSE.
TECHNICAL DATA
Lifestyle Programmers and Timeswitches conform to the essential requirements of these Directives:
2014/30/EC – Electromagnetic compatibility 2014/35/EC – Low voltage
LP241Si, LP522Si & LP722Si PROGRAMMERS LP111Si & LP711Si TIMESWITCHES
Voltage
230Va.c.+10% - 10% 50Hz
Programmer Rating
2 (1) A 230V a.c. each switch
Timeswitch Rating
2 (1) A 230V a.c.
Ambient temp
Operating: 0º to 45ºC Storage: -20ºC to 50ºC
Without mainspower
Display: blank Time: always kept Program times:always preserved
Programming resolution
1 minute
Wiring
Fixed wiring only, to comply with current IEEregulations
Maintenance Mustbemaintained byaqualified
electrician or heating engineer
Drayton
Drayton Lifestyle
Switchmaster
Switchmaster
ACL ACL
Danfoss Randall Danfoss
Randall
Danfoss Randall Danfoss Randall Danfoss Randall Danfoss Randall Danfoss Randall
Danfoss Randall
Grasslin Towerchron Honeywell Honeywell Honeywell
Horstmann
Landis&Staefa*
Myson
Sangamo
Smiths
Smiths
Smiths
Sunvic
Sunvic Venner
Email: customer.care@draytoncontrols.co.uk
Web: www.draytoncontrols.co.uk
PROGRAMMER TERMINAL COMPARISONS
MAKE MODEL
Pollution degree
Software class
Ball pressure test temperature
Rated impulse voltage
2
2
75ºC
2.5kV
Myson
Drayton Drayton
Drayton British Gas
3
2014/30/EC Electromagnetic compatibility 2014/35/EC – Low voltage
Myson
P
otterton Myson
Potterton Myson*
Sunvic Sunvic
BEFORE INSTALLATION
First, make sure the mains supply is switchedoff!
PROGRAMMER ONLY
The programmer must be set to the type of system it is to con­trol. The link on the back of the unit has two settings –Pand G.
P=afully pumped and controlled system–allowing
heating and hot water to be set separately.
G=agravity-fed hot watersystem – which does not allow
independent setting of heating without hotwater, though hot water can be controlledalone.
USING AN EXISTING WALL-PL ATE
Loosen the securing screws on the old programmer and unplug it. Check that there’s 70mm clearance to the right of the wall-plate, and 25mm above it.Check the chart on the next page to compare terminals and if necessary, change the wiring of the wall-plate to suit. Now plug the Lifestyle unit into the wall-plate and tighten the securing screws.
Check the 3A fuse, and switch on the mains.
FITTINGANEW WALL-PLATE
The ideal location is 1.4m above floor level, with reasonable lighting, good access, no condensation, no extremes of temperature, andasupporting surface that fully covers the back of theunit.
Position with 70mm clearance to the right, 25mm above, and sufficient room to access the securing screws underneath.
Fix, with terminals at the top,either direct toaflat wall using wall plugs andNo.6x1”(25mm)woodscrews, or on a flush mount­ingsingle conduit box type UA1 (BS4662) using M3.5 x 14 bolts. DO NOT USEASURFACE MOUNTING BOX.
* Can simply be removed from the backplate and replaced without any disturbance to the existing wiring.
WIRING THE TIMESWITCH
WIRING THE PROGRAMMER
C Common HCall for Heat S Satisfied N Neutral E Earth L Live
USINGADRAYTON SIMP-L-FIT, ALTHOUGH NOT NECESSARY, WILL MAKE THIS INSTALLATION EASIER.
Sangamo
Salus
Myson
4
What isaprogrammer?
...an explanation for householders
Programmers allow you to set ‘On’ and ‘Off time periods. Some models switch the central heating and domestic hot
Drayton Tempus 1, 2 (new models) NL 1 2 3 4
Drayton Lifestyle
LP111, LP711, LP111Si, LP711Si
NL 1 2 3 4
Switchmaster 300 NL 4 1
ACL TC (Towerchron) 21 4 7
Drayton Tempus 1, 2 (old models) NL 1 2 3 4 Switchmaster 980 NL 4 1
Danfoss Randall TS15, 75 (Mk18) E N L 1 4 2 5/6 Danfoss Randall TS715, TS715Si NL 1 4 2 3 Danfoss Randall TS975 E N L 5 4 6 1,2,3 Danfoss Randall SET1, SET1E ENL 5 4 6 Danfoss Randall SET4 ENL 5 4 6 Danfoss Randall 103, 103E, 103E5, 103E7 4 5 6 3 1 2 Danfoss Randall 911, 971 ENL 5 6 42 Grasslin Towerchron QE1 NL 2 4 Grasslin Towerchron T2001, T2001Q ENL 7
Honeywell ST 6100A, ST 6100C NL 1 4 2
Honeywell ST 7000B Horstmann Centaur SC1, SC7
L
Horstmann
Centaur Plus, C11, C17, C17-ZW
NL 2 4 3
Horstmann Emerald 423, Pearl Auto N L 2 4 Horstmann 517, Coronet, H11, H17 E N L 3 4
Landis&Staefa RWB3
NL 43
Landis&Staefa RWB30, RWB50, 100, 152, 170
NL 4 4 3
Landis&Staefa RWB7
Potterton Myson EP4000, 4001, 4002, 5002 NL 5 4 2
Sangamo M6
Smiths Centroller Mk1, Mk2 NL 3 2
Smiths Centroller 30 12 3/4
Smiths Centroller 300, 980 NL 4 1
Sunvic Select 107, SunProl1000 NL 1 3 2 4
Sunvic SP20, SP35 NL 3 5 4 5 Venner Vennerette N L LINE LOAD
TIMESWITCH TERMINAL COMPARISONS
Earth
Neutral
Live
Common
On
Off
Spare
MAKE MODEL
SINGLE
CHANNEL
for heating
LP111Si, LP711Si
SINGLE
CHANNEL
Timeswitch
E
46
3
1
Salus EP101, SP120
4
3
NL
Myson
Myson
NL 1 3 2 4
MEPIC
4
Mictrotimer (link L-5 and 5-8)
EN L 5 6
E
NL
423
3
32
NL 1 2 3 4
British Gas EMT2, UT1, UT2
NL 1 324
Drayton
Drayton
Drayton
NL 1 2 3 4
NL 1 2 3 4
NL 1 2 3 4
SM1
miGenie Wish 1
MiTimeMT711R, MiTime RF Pack1
CurrentModels
Discontinued/Competitors’ Models
5
Programmers allow you to set ‘On’ and ‘Off time periods. Some models switch the central heating and domestic hot water on and off at the same time, while others allow the domestic hot water and heating to come on and go off at different times.
Set the ‘On’ and ‘Off time periods to suit your own lifestyle. On some programmers you must also set whether you want the heating and hot water to run continuously, run under the chosen ‘On’ and ‘Off heating periods, or be permanently off.
The time on the programmer must be correct. Some types have to be adjusted in spring and autumn at the changes between Greenwic h Mean Time and British Summer Time.
You may be able to temporarily adjust the heating pro- gramme, for example, ‘Override’, Advance or ‘Boost’. These are explained in the manufacturer’s instructions.
The heating will not work if the room thermostat has switched the heating off. And, if you haveahot-water cylinder, the water heating will not work if the cylinder thermostat detects that the hot water has reached the correct temperature.
Drayton
Tempus 6,7
NL1 2 3 4
Drayton Lifestyle LP112, LP241, LP522, LP722 N L1 2 3 4
Switchmaster 400, 600 NL 4 3 1
(no connection to terminal 4 on 600)
Switchmaster 805, 900, 900i NL4 2 3 1
ACL MP (Towerchron) 21 ACL FP (Towerchron) 2 1 8 11 6 10
Tempus 3, 4, 6,7(old models),
Danfoss Randall
CP15, CP715, FP15, FP715 (Mk18
) ENL1 2 3 4
Danfoss Randall 3020P, 3060 E76 42 Danfoss Randall 4033 (link 1-6) E 7 65 3 4 2 Danfoss Randall 102, 102E, 102E5, 102E7 (link 6-3) E 5 6 12 Danfoss Randall 701 (link L-5 and 5-6) ENL 31 Danfoss Randall 702 (link L-5 and 5-6) ENL4 2 3 1 Danfoss Randall 922, 972 (link L-2 and 2-5) ENL1 4 3 6
Danfoss Randall SET2, SET2E, SET3E, SET3M, FP975 E N L 3 6 1 4
SET5 (link L-2 and 2-5)
Grasslin Towerchron DP 72, QE2 NL1 2 3 4 Honeywell ST 699/799 (link L-5 and 5-8) NL7 4 6 3 Honeywell ST 6200, ST 6300, ST 6400, ST 6450 N L 1 2 3 4 Honeywell ST 7100 (link L-3 and 3-6) N L7 4 8 5
Horstmann 525, 527, 425 Diadem, H21, H27, E N L 3 6 1 4
H121, Tiara (link L-2 and 2-5)
Landis&Staefa* RWB2, RWB2E, 20, 40, 102, 200, N L 1 2 3 4
252 & 270, RWB9
Myson Microtimer (link L-5 and 5-8) NL7 4 6 3
Potterton Myson All EP2000’s, EP3000’s, EP6000’s N L 1 2 3 4
(link L-5 and N-N)
Potterton Myson* Mini Minder NL1 2 3 4
Sunvic Select 207, SunPro 2000 NL1 2 3 4 Sunvic SP50, SP100 (link L-3) NL1 4 2 5
Sunvic SP20,
SP35 NL 3 5 4 5
Venner Vennerette N L LINE LOAD
Users Instructions
PROGRAMMER TERMINAL COMPARISONS
Current Models
Earth
Neutral
Live
Ch1 on
Chl2 on
Ch3 on
Ch4 on
MAKE MODEL
Discontinued/Competitors’ Models
* Can simply be removed from the backplate and replaced without any disturbance to the existing wiring.
INTRODUCTION
Lifestyle Timeswitches will automaticallycontrolyour system by switching it on and off at times that suit you. The light on the front of the timeswitch shows when it’s on.
LP111Si–a24hr program,upto3heating periods
each day, and every day the same.
LP711Si–a7-day program, allowing for different
Sangamo M5 (link 1-6)
NL 1
8
NL1 2 3 4
Salus EP200, SP220
Myson MEP2C
NL1 2 3 4
Drayton Drayton
Drayton British Gas
SM2 miGenie Wish 2
MiTime MT721R, MiTimeRF Pack 2 & 3
EMP2, UP1, UP2
NL1 2 3 4 NL1 2 3 4 NL1 2 3 4
NL1 2 3 4
6
Sunvic Select
207, SunPro 2000 N L1 2 3 4
Sunvic SP50, SP100 (link L-3) NL1 4 2 5
* Can simply be removed from the backplate and replaced without any disturbance to the existing wiring.
WIRING THE TIMESWITCH
Make the wiring connections as above. Note that the output contacts arevoltage-free, so power needs to be put on to Terminal1either by linking from Terminal L or from a separate supply with a 3A fuse.
WIRING THE PROGRAMMER
Arrowed numbers relate to the junction box.
Consult boiler handbook for details of pump overrun wiring.
Connection Charts
Wiring Colour Codes
GR Grey Y Yellow BK Black BL Blue BR Brown RD Red W White OR Orange YG Yellow/Green
C Common HCall for Heat S Satisfied N Neutral E Earth L Live
*Thermostat Key
USINGADRAYTON SIMP-L-FIT, ALTHOUGH NOT NECESSARY, WILL MAKE THIS INSTALLATION EASIER.
LP1
11Si–a24hr program,upto3heating periods
each day, and every day the same.
LP711Si–a7-day program, allowing for different
timings on each day of the week,upto3heating periods each day.
If the engineerhasn’t set your timings foryou, your timeswitch will work withastandard program that has been set at the factory. If this doesn’t suit you, it’s very easy to changeit– whenyou’ve read this introductory section, simply turn to the page for your timeswitchmodel.
Remember:
Make your changes using the SET?, YES/-, and + buttons
You can’t set ON1 as the last timing before midnight, but you
can set OFF3 after midnight–providing it’s not more than 23 hours and 59 minutes after ON1.
You need to set the timings in sequence–i.e. ON1, OFF1, ON2,
OFF2, ON3, OFF3. If you get out of sequence, the display will flash a warning.
on the programmer, found under the bottom flap.
7
DUAL
CHANNEL
LP241Si, LP522Si, LP722Si
SINGLE
CHANNEL
for heating OR hot water
LP111Si, LP711Si
Technical Helpline: 0333 7000622
Email: customer.care@draytoncontrols.co.uk
Web: www.draytoncontrols.co.uk
for heating AND hot water
User’s Instructions
06490050001 ISS F
SINGLE
CHANNEL
Timeswitch
DUAL
CHANNEL
Programmer
SERVICE INTERVAL
Lifestyle
If th
e engineer has set your program and timings–you won’t need to do anything else. Just keep this guide inasafe place for future reference.
Sometimes you might need to change the wayyouuseyour system temporarily–perhaps due to an exceptionallycold day.
Here’s how to do it–withoutaffecting the timings in your program.
Switching on and off
On the front of the timeswitch there is an button.
It allows youtoswitch your system either on or off, irrespective of the program. So if the heating is off, and you want warmth now, you can either
1. Press Advance to switch it on (ADV will be displayed), and it will
stay on until the end of the next period. Or if the heating is on and you don’t need it, pressAdvance and it will go offuntil the beginning of the next ON period.
Advance will only operate in TIMED or ONCE modes.
2. Press&Hold to switch on for an extra hour( &BSTwill be displayed), then Press again for two( )orthree ( ) hours. To cancel Boost, Press Boost again ( ). Or if the heating is already on,using Boost will extend the ON time by one, two or three hours.
DAY-TO-DAY VARIATIONS
Ove
r-riding theprogram
OF
F
TIMED
ONCE
8
What isaprogrammer?
...an explanation for householders
Programmers allow you to set ‘On’ and ‘Off’ time periods. Some models switch the central heating and domestic hot water on and off at the same time, while others allow the domestic hot water and heating to come on and go off at different times.
Set the ‘On’ and ‘Off’ time periods to suit your own lifestyle. On some programmers you must also set whether you want the heating and hot water to run continuously, run under the chosen ‘On’ and ‘Off’ heating periods, or be permanently off.
The time on the programmer must be correct. Some types have to be adjusted in spring and autumn at the changes between Greenwich Mean Time and British Summer Time.
You may be able to temporarily adjust the heating pro­gramme, for example, ‘Override’, ‘Advance’ or ‘Boost’. These are explained in the manufacturer’s instructions.
The heating will not work if the room thermostat has switched the heating off. And, if you haveahot-water cylinder, the water heating will not work if the cylinder thermostat detects that the hot water has reached the correct temperature.
Email: customer.care@draytoncontrols.co.uk
Web: www.draytoncontrols.co.uk
9
User’s Instructions
TIMESWITCHES
INTRODUCTION
Lifestyle Timeswitches will automaticallycontrolyour system by switching it on and off at times that suit you. The light on the front of the timeswitch shows when it’s on.
LP111Si–a24hr program,upto3heating periods each day, and every day the same.
LP711Si–a7-day program, allowing for different timings on each day of the week,upto3heating periods each day.
If the engineerhasn’t set your timings foryou, your timeswitch will work withastandard program that has been set at the factory. If this doesn’t suit you, it’s very easy to changeit– whenyou’ve read this introductory section, simply turn to the page for your timeswitchmodel.
Remember:
Make your changes using the SET?, YES/-, and + buttons
You can’t set ON1 as the last timing before midnight, but you can set OFF3 after midnight–providing it’s not more than 23 hours and 59 minutes after ON1.
You need to set the timings in sequence–i.e. ON1, OFF1, ON2, OFF2, ON3, OFF3. If you get out of sequence, the display will flash a warning.
LP711
Si –a7-day program,allowing for different timings on
each day of theweek, up to 3 heating periods each day.
Want to leaveatimingasitis?Just press SET? and move on to the next one.
If you need to reset your timings to the standard program and
When you press SET? after setting OFF3, the timeswitch will
return to normal operation.
ON
2 –start of secondtimed period* 12.00pm
OFF2 end of second timed period* 12.00pm
ON 3 –start of third timed period 4.30pm
OFF3 final switch-off of the day 10.30pm
Changing the timings
Press the SET? buttonandyou’ll see ‘SE
PROG?
Press the YES button, and you’ll see ON1, the start of your first
heating period. Adjust it in 1-minute stepsusing the–and+ buttons. If the–and+buttons are held down, the time changes in 10-minute steps.
Press SET?, and you’ll see OFF1, the end of your firstheating
period. Adjust thisinthesame way, press SET? then repeat the procedure for ON2, OFF2, ON3 andOFF3
on the programmer, found under the bottom flap.
10
Make
your changes using the SET?, YES/-, and + buttons
You can’t set ON1 as the last timing before midnight, but you
can set OFF3 after midnight–providing it’s not more than 23 hours and 59 minutes after ON1.
You need to set the timings in sequence–i.e. ON1, OFF1, ON2,
OFF2, ON3, OFF3. If you get out of sequence, the display will flash a warning.
SWITCHING
ON 1 –start of first timed period
OFF1– end of first timed period
ON 2 –start of secondtimed period
OFF2– end of second timed period
ON 3 –start of third timed period
OFF3– final switch-off of the day
LP711Si –a7-day program,allowing for different timings on each day of theweek, up to 3 heating periods each day.
Want to leaveatimingasitis?Just press SET? and move on to the next one.
If you need to reset your timings to the standard program and start again, press ‘SET and ‘+ together to go back to the pre-set program.
Your system will come on forupto3heating periods every 24hrs. ON1 starts the first one, OFF1 finishes it, and so on. Notice that ON2 and OFF2 are set to the same time.* This means your system won’t respond, but if you want to activate thatmiddle periodorchange any other timings–read on.
The standard program
ON
1 start of first timed period 6.30am 7.00am
OFF1 end of first timed period 8.30am 9.00am
ON 2 start of second timed period*12.00pm 12.00pm
OFF2 end of second timed period*12.00pm 12.00pm
ON 3 start of third timed period 4.30pm4.00pm
OFF3 final switch-off of the day 10.30pm 11.00pm
THE LP711Si 7-DAY ELECTRONIC TIMESWITCH Cont...
Changing the timings
Press the SET? button and you’ll see SET PROG?’.
Set all weekdays
First yousetthetimes that are goingtobethe same for each weekday, then you can select each day individually and make any further adjustments. If you want each day to be quite
PROG?
If the engineer has set your program and timings–you won’t need to do anything else. Just keep this guide inasafe place for future reference.
Sometimes you might need to change the wayyouuseyour system temporarily–perhaps due to an exceptionallycold day.
Here’s how to do it–withoutaffecting the timings in your program.
Switching on and off
On the front of the timeswitch there is an Advance/Boost button.
It allows youtoswitch your system either on or off, irrespective of the program. So if the heating is off, and you want warmth now, you can either –
1. Press Advance to switch it on (ADV will be displayed), and it will
stay on until the end of the next period. Or if the heating is on and you don’t need it, pressAdvance and it will go offuntil the beginning of the next ON period.
Advance will only operate in TIMED or ONCE modes.
2. Press&Hold Boost to switch on for an extra hour( &BSTwill
be displayed), then Press again for two( )orthree ( ) hours. To cancel Boost, Press Boost again ( ). Or if the heating is already on,using Boost will extend the ON time by one, two or three hours.
DAY-TO-DAY VARIATIONS