Drayton RTS2, RTS3, RTS4, RTS6, RTS9 Installation Instructions Manual

...
Page 1
RTS Thermostat
Installation instructions
Models
RTS1: Standard heating thermostat
RTS2 Heating thermostat with call for heat LED indicator
RTS3: Indoor frost thermostat
RTS4 Volt free heating/cooling change over switch
RTS9 & 10: Volt free heating/cooling changeover switch with call
for heating LED indicator
IMPORTANT NOTE
RTS thermostats are ELECTRONIC with a relay output.
Unless connected to a 230V mains supply the relay will
not operate, no 'click' will be heard and the call for heat
contact will remain open.
Location
Care should be taken to mount the thermostat in a position which is not subject to direct sunlight or draughts. Preferably it should be mounted on an inside wall about 1.5m (5ft) above the floor in a position where it can respond to room temperature but away from the direct influence of radiators or other appliances giving off heat.
Note: If the thermostat is to be used as a frost protection device it should be located in the coldest part of the premises.
Fixing
1. Loosen the securing screws, remove the wall-plate and, if surface wiring is to be used, snap out the cable entry strip on the bottom edge of the wall-plate with a pair of pliers.
2. Fix the wall-plate, terminals at the top, either direct onto a flat wall using wall plugs and No 6 x 1” woodscrews or on a flush mounting single conduit box using M 3.5 x 14 screws.
3. Complete the wiring to the wall-plate in accordance with the relevant diagram shown overleaf in accordance with I.E.E. regulations.
Note: The thermostat is for fixed wiring only and is double insulated, the earthing continuity (loop) terminal is only provided for convenience.
4. Plug the thermostat onto the wall-plate and tighten the securing screws.
5. Before switching on the mains ENSURE THE CIRCUIT
FUSE IS 3A.
WARNING
Disconnect mains supply before fitting or removing from
wall-plate.
A switch having contact separation of at least 3mm in all
poles must be incorporated in the fixed wiring as a means
of providing full disconnection of the mains supply.
Setting
1. Set the desired room temperature on the control knob against the setting mark.
2. The setting range may be limited or a particular setting locked through the use of the mechanism to be found under the control knob.
3. To adjust the limiters firstly set the thermostat to the desired temperature and then carefully pull off the knob.
4. Lift and rotate the two limiting arms to re-position them in the required notches.
5. Replace the knob with the previously set temperature against the setting mark.
Technical data
Electrical supply: 230V ac 50Hz fused 3A
Double insulated (no earth required)
Temp. range: RTS1, 2, 4 & 9 10° to 30°C
RTS3 (Frost) 3° to 10°C RTS6 5° to 23°C
Switch type: RTS 1, 2 & 3 S.P.S.T 2(1)A 230V ac live
output
RTS4, 9 & 10 S.P.D.T 2(1)A 230V ac volt free
Temp. sensor: Electronic
Drayton
RTS10
14° to 30°C
Page 2
06490053001 Iss. A
0205
Customer Service Tel: +44 (0) 845 130 5522 Technical Helpline Tel: +44 (0) 845 130 7722
Room thermostats
Make Model Drayton RTS 1 & 2 N L 3
Drayton RTS 4, 5, 6, 9 & 10
N
L 132 Drayton Digistat 1 1 3 2 ACL Lifestyle PT271/371 N L 1 3 2 ACL Lifestyle TS 142 E 4 1 2 ACL Lifestyle TA 350 5 1 3 2 Drayton Digistat (old version) 4 1 2 3 Drayton RT & RTE 4 1 2 3 Danfoss Randall TP1 E N L 1 2 Danfoss Randall RT1. TP2, 3, 4 & 5 1 3 2 Danfoss Randall RD3, RD3A 4 1 2 Danfoss Randall RTC, RTM, RSR E N 3 1 2 Danfoss Randall R504 N 3 1 2 Honeywell 6060, 6061, 6063 2 1 3 4 Honeywell CT200 A B C Horstman HRT 1 E 4 1 2 Landis & Gyr RAD 1 E 1 2 3 Potterton PRT 1 N L H Potterton PRT 2 & 100 ST N TL H Potterton PRT 100 DT N TL H C Sunvic TLX 2259 E N L 1 2 Sunvic TLX 2356 E 3 1 2 Sopac TA 350 E 1 3 2 Sopac TA 351 E 4 1 3 2 Switchmaster SRT 2 5 1 3 2 Tower SS E 4 1 2
Earth
Neutral
Live
Common
Demand
Satisfied
Wiring (schematic)
Note: It is essential to make a neutral connection to terminal N.
Note: Link between terminals L and 1 if mains voltage is required on the thermostat switch.
Information
The RTS room thermostat replaces earlier models of both ACL and Drayton room thermostats subject to a maximum load of 2(1)A 230V ac. The wiring conversion between these models is:
ACL ACL Drayton RTS RTS
TS142 TA350 Roomstat 1,2 4, 6,
RT (E) & 3 9 & 10
Live supply 1 1 L L
Neutral
4– 4NN
(accelerator heater)
Call for heat 2 3 2 3 3
Heating satisfied
–2 3 –2
(call for cooling)
Volt free
–1 – –1
switch common
Earth connection E 5
Conforms to the essential requirements of the following
directives:
89/336/EEC – Electromagnetic compatibility
73/23/EEC – Low voltage directive
N L 1 2 3
N
230V AC 50HZ
fused 3A
L
Call for heat
RTS1, RTS2 and RTS3
N L 1 2 3
N
230V AC 50HZ
fused 3A
L
Call for heat
RTS4, RTS6, RTS9 and RTS10
COM
Heating satisfied o
r
call for cooling