Drayton MiTime T742R User Manual

Step 1: Keys and Display
MiTime
Home key: Press to go back to the home screen at any time
Date
Home screen showing current Status and Set tings link for all zones
Time
Back key: Press to return to the previous screen
Help text to prompt for next action. It relate s to the highlighted line
Arrow keys: Press to move the highlight on screen, and to change field values
Advance key: Press from the home or zone details screens to advance to the next on or off period
+hr key: Press from the home or zone details screens to add up to 3 hours to the current period
Multi Channel: MiTime T742R
Select key: Press to select highlighte d
options, and to open and save editor screens
This icon used throughout these instructio ns refers to this button
Step 2: Home Screen
Zone = Heating Current status: the pr ogramme is On
until 12:00 am Link to zone details, see Step 3.
Link to Settings
See further detail s in Step 6.
Zone = Hot Water
Current status: the pro gramme is Off until 12:00 am Link to zone details, see Step 3.
Press Select ( ) to view or edit zone
Step 5: Period Settings
Day range & period
Stored programmes
MiTime contains 3 pre- set programmes. An example is shown below. These programmes can be mod ified according to personal needs and can be sto red by using a name. Via this name they also can be re-loaded. Once a programme has been modifi ed,
the original factory pr e-set will no longer be available. On a System Reset, only the cur rent loaded programme will be replaced with th e factory setting – see Installation Guide Ste p 4.
1st On 6:30am 6:30am 7:00am
1st Off 8:30am 8:30am 9:00am
2nd On 4:30pm 4:30pm 4:00pm
2nd Off 10:30pm 10:30pm 11:00pm
All week Week & Weeken d
Mon-Sun Mon-Fri Sat-Sun
Programme 1 Example:
Step 6: Additional User Settings
Press Select to enter a specifi c Setting. Option s shown below:
Feature: Description: Factory Pre-Se t:
Help Tips Describes th e button functions
Holiday switch off
In the period until holiday st arts the produc t will operate normally. If holiday is disabled manually or termina tes automatically, the mod e before start of holiday will be re-inst ated.
An enabled holiday will be indic ated with a suitcase sy mbol in the top line. If holiday is active, in the Set : line the holiday end date will be indica ted. In the Summary screen the sui tcase will be visible tog
ether with the holiday
temperature
Status Enable or disable holiday mo de. Disabled
Zones Holiday mode can be applied to a specific zone o r
all zones
All zones
Holiday start time (From)
Set the time for the star t of your holiday Current time -
nearest hour
Holiday start date (From)
Set the date for the star t of your holiday Today
Holiday end time (To)
Set the time for the end of your holiday Current time -
nearest hour
Holiday end date (To)
Set the date for the end of your holid ay Today +
1 week
Time and date sett ings
Set time To set time of day Factory set
Set date To set date Factory set
Daylight saving To enable or disable daylight saving Enabled
Clock format To select 12h or 24h clock mode 12hr
What is a programmer?
... an explanation for householders
Programmers allow you to set ‘On’ and ‘Of f’ time periods. Some models swit ch the central heating and domestic hot water on and off at the sa me time, while others allow the domestic hot water and heat ing to come on and go off at different times .
Set the ‘On’ and ‘Off ’ time periods to suit your own lifestyle. On some prog rammers you must also set whether you want the heating and hot water to run contin
uously, run under the chosen ‘On’ and ‘Off’
heating periods, or be permanent ly off.
The time on the programmer must be cor rect. Some types have to be adjusted in spring and aut umn at the changes between Greenwi ch Mean Time and British Summer Time.
You may be able to temporarily adjust the heating programme, for example, ‘Override’, ‘Advance’ or ‘Boost’. These are explained in th e manufacturer’s instruction s.
The heating will not work if the room thermos tat has switched the heating of f. Also, if you ha
ve a hot-water cylinder, the water heating will not work if the cylinder thermostat detec ts that the hot water has reached the correct tempera ture.
MiTime
Drayton
MiTimeTM Programmer Series
Multi Channel
Model: T742R
Technical Helpline: 0333 7000 622 Website: www.draytoncontrols.co.uk E-mail: customer.care@draytoncontrols.co.uk
l
@DraytonControls
x
/DraytonControls
EU Design Regs:- 002180638-1/2/3 User Guide 06490188001 Iss F
MiTime
Step 3: Zone Details
Zone = Heating
Link to Programme timetable
See further deta il in Step 4.
Now: describes the current s tatus, e.g.programme is On until 12:00 am. Link to Programme timetable - see fur ther details in Step 4.
Current mode: Auto
Options: see table below.
Press Select ( ) to change mode
Mode: Description:
Auto The programmer will control the
ON & OFF times in line with the programmed timetable
Always Off The selected zone will be OFF
Always On The select ed zone will be ON
All Day (first on / last off)
The programme will control the ON & OFF times in line with the programmed timetable, but using only the first ON event and the last OFF event - it will remain ON in between these two pe riods.
Step 4: Prog. Timetable
Zone = Heating
Help text: Use left /right buttons to
select the days you want to change
Period 1 settings: describes the current timetable settings, e.g. Heating has been programmed to turn On at 6:30am and go off at 8:30am
Period 2 settings: describes the current timetable settings, e.g. Heating has been programmed to turn On at 4:30pm and go off at 10:30pm
Press select (
) when highlighted to adjust
settings (see Step 5)
Up to 4 periods can be programmed
Arrow denotes that further opti ons are available if you scroll down.
Timetable day range: Monday to Friday (Week and weekend)
Options: Individual days (7day), Week and weekend (5/2day), All week (24hr). The available blocks depend on the selection in menu “change timetable type”
Link to Copy days
HOMEOWNER Guide
Zone = Zone 3
Current status: the pro gramme is Always Off Link to zone details, see Step 3.
LED: Illuminates when any zone is scheduled to be ON
Feature: Description: Factory Pre-Se t:
Programme Timetable
On & Off times for the cur rent period can be modified. See descript ion in ‘Step 4’
Copy days Will copy the curr ent day to one or more other days
Add Period Adds a Time event. It will be adde d at the correct
position within th e day. There is a maximum of 4 periods.
Remove Period Removes the selec ted period. There needs to be at
least 1 period
Change Timetable Type
The visible day-blo cks available in "programme timetable" can be defin ed, see Step 4
Individua
l days Each day ca n be programmed individually
Week and weekend
Mon… Fri and Sat… Sun can be programm ed as 2 blocks
Default
All week Mon…Sun can be programmed as one block
Stored programmes
MiTime contains 3 pr e-set programmes . These programmes can be modi fied according to personal needs and can be stored by using a nam e. Via this name they can also be re-lo aded. Once a programme has been modified, the original f actory pre-s et will no longer be available unless a S
ystem Reset is applie d -
see Installatio n Guide Step 4.
Programme 1
Load stored programme
A pre-set programme c an be loaded
Save current programme
The current programme c an be saved by name (Each pre-set program in cludes: Individual days, week / weekend, all day and custom day sche dules)
Help text: Use left /right buttons to change fields
Period settings: On at 6:30am and Of f at 8:30am
Highlight shows adjust able field:
Use up/down buttons to adjust values
HOMEOWNER Guide
: Indicates a Service warning
: Indicates that holiday
is enabled
401 Southway Drive Plymouth PL6 6QT United Kingdom
Drayton
Drayton
Drayton
Technical Data
MiTime T741R
Voltage 230V a.c. +10% -10% 50Hz
Switch Rating 2 (1) A 230V a.c. each switch
Ambient temp Op erating: 0º to 40ºC
Storage: -20ºC to 50ºC
Without mains power
Display: blank Time: always kept Programme times: always preserved
Programming resolution
1 minute
Wiring Fixed wiring only, to comply with
current IEE regulatio ns
Maintenance Must be maintained by a qualified
electrician or hea ting engineer
Pollution degree 2
Rated impulse voltage
2
.5kV
Ball pressure tes t temperature
75°C
Relevant EC Directives:
2014/35/EC Low Voltage Directive 2014/30/EC Electromagnetic Compatibilit y Directive 2006/66/EC Batter y Directive 2011/65/EU RoHS Directive
Applied Standar ds: EN60730 -1; EN60730-2-7
Step 2: Wiring
Connect the wiring as shown below.
Step 3: Connection Charts
Step 4: Installer Settings
Arrowed numbers relate to the jun ction box.
* Consult boiler handbook for de tails of pump overrun wiring.
Make the wiring connections , as shown, for the appropriate system. For sur face wiring, snap out the cable entry str ip on the bottom edge of the wall-plate. MiTime units are double- insulated and need no earth connection, but an ear thing continuity (loop) terminal is provided for convenience.
After wiring, plug in the unit and tighten the se curing screws. Check the mains input has a 3A fuse, and switc h on the mains.
4 Zone system: Models T742R
INSTALLATION Guide Step 1: Mounting the Wall-plate
! IMPORTANT:
Installation mus t only be carried out by a qualified electric ian or heating engineer.
Make sure mains input has a 3 amp fuse.
! CAUTION! Before inst allation, make sure the mains supply is switche d off!
MiTime
Option 2: Using an existing wall-plate
Loosen the securing screws on the old programmer and unplug it. Check that there is 70mm clearance to the right of the wall-plate and 25mm above it. Check the wiring diagram for your product model to compare terminals and, if necessar y, change the wiring of the wall­plate to suit. Now plug the MiTime unit into the wall-plate and tighten the securing screws.
Check the 3A fuse, and switch on the mains.
Option 1: Fitting a new wall-plate
The ideal location is 1.2m above floor level, with reasonable lighting, good access, no condensation, no extrem es of temperature and a suppor ting surface that fully cover s the back of the unit. Position with 70mm clearance to the right, 25mm above and sufficient room to access the securing screws underneath. Fix, with termina ls at the top, either direct to a flat wall using wall plugs and No. 6 x 1” (25mm) woodscrews, or on a flush mounting single conduit box type UA1 (B
S4662) using M3.5 x
14 bolts.
! DO NOT use a surface mounting box
Feature: Des cription: Factory Pre-Set:
Installer Set tings
! CAUTION! These settings should only be modified by a qualified person. They can influence safety and the proper functioning of the system.
Zone Settings Customise the MiTime according to pe rsonal requirement s
Select zone Select a zone for the fo llowing actions
Rename zone To rename an exis ting zone Heating,
H Water, Bed 1
Delete zone To delete an existing zone. The last zon e cannot be
deleted
Min. 1 Zone
Add Zone Add a new zone, apply a name & bind a the rmostat.
A time table can be applied.
Max. 4 Zones
System Setting s These are the settin gs which will be applied to the MiTim e unit
View product information
View the product det ails, e.g. Part number, Firmware revision etc.
Backlight sett ings Available options are: On with ti meout, Always On,
Always Off
On with timeout
Screen lock Enable or disable the lock in the Mi Time unit
To Lock: Enter a 3 digit code for protect ion To Unlock: Enter the 3 digit code
000 Master Code 401
Powersave To reduce power use when not being adjus ted.
Available options are: Powers ave off, partial displa y with key data, no display until bu tton press
Powersave off
System Reset Will reset all settin gs to factory pre- sets
Service Setti ngs To help comp ly with regulation 36 of the Gas safe ty [Installation & Use]
regulations 1998
Si Status Enable or disable Ser vice mode Disabled
Si Type Select betwe en, Reduced Comfort , Switched Off &
No Effect (warnin gs only)
Reduced Comfort
Reduced comfort duration
Set the duration for the reduc ed comfort sett ing (0 to 60mins.)
15 min.
Si due date Set the date th e next boiler service is due Today
Warning start Set the numbe r of days for the on-screen ser vice due
warning (0
to 60 days)
30 days
Boost status Enable or dis able Service Boost Disabled
No. of boosts Set the num ber of Boosts to be available af ter service
is due (1 to 99)
10
Audible Alarm Enable or dis able Service Alarm Enable d
Installer tel Enter the Installer teleph one number if required
Set password Set pas sword to restrict acc ess to the Service set tings 000 0
! IMPORTANT:
Always switch off th e mains before removing the MiTime programm er – and never fit it to a live wall-plate!
! IMPORTANT:
Always switch off th e mains before removing the MiTime programm er – and never fit it to a live wall-plate!
Ch1 Ch2 Ch3 Ch4
Internal Wiring
3 Zone system: Models T742R
From the Home screen, select Set tings, then Installer set tings as shown.
From here you can edit the assigned zones, rename the m if required and adjust the Service set tings.
If using the Service feature, remem ber to set the Password when complete.
Installer Notes:
Drayton
Loading...