THE LP711 7-DAY ELECTRONIC TIMESWITCH Cont...
Changing the timings
Press the SET? button and you’ll see ‘SET PROG?’.
Set all weekdays
First you set the times that are going to be the same for each
weekday, then you can select each day individually and make
any further adjustments. If you want each day to be quite
different, go straight to ‘Set each day’.
Press the YES button, and the display will ask ‘SET MON to FRI
PROG?’.
Press YES and you’ll see ON1, the start of your first heating
period. Adjust it in 1-minute steps using the – and + buttons.
If the – and + buttons are held down, the time changes in
10-minute steps.
Press SET?, and you’ll see OFF1, the end of your first heating
period. Adjust this in the same way, press SET?, then repeat
the procedure for ON2, OFF2, ON3 and OFF3.
Set each day
If, after you’ve set OFF3 you want to fine-tune one or more
weekdays, press SET? until you find the first day you want to
adjust – then go through the procedure, altering any time you
wish. Press SET? to move on to the next day. When you’ve
finished, press SET? until you see ‘SET SAT SUN PROG?’.
If you don’t want to alter any individual days, keep pressing
SET? until you see ‘SET SAT SUN PROG?’.
Set weekend
Press YES and alter ON1, OFF1, ON2, OFF2, ON3 and OFF3
times in the same way.
Set each day
If, after you’ve set OFF3 for both SAT & SUN, you want to fine-
tune Saturday or Sunday, press SET? until you find the first day
you want to adjust – then go through the procedure, altering
any time you wish. Press SET? to move on to the next day.
When you press SET? after setting your hot water for Sundays,
the programmer will go back to normal operation.
If you don’t want to alter either day, keep pressing SET?
until the programmer goes back to normal operation.
If the engineer has set your program and timings – you
won’t need to do anything else. Just keep this guide in a
safe place for future reference.
INTRODUCTION
Lifestyle Programmers will automatically switch your central
heating and hot water on and off at times that suit you.
Depending on your system, central heating and hot water
can either both come on and off at the same time, or work
independently. The red light on the front of the programmer
shows when each one is on.
There are 4 models in the Lifestyle range:
LP112 – a 24hr program, with linked central heating and hot
water on for up to 3 heating periods each day, and every day
the same.
LP241 – a 24hr program, with central heating and
hot water working independently for up to 3 heating periods
each day, and every day the same.
LP522 – a 5/2-day program allowing for different
timings at the weekends, with central heating and hot water
working independently for up to 3 heating periods each day.
LP722 – a 7-day program allowing for different
timings on each day of the week, with central heating and
hot water working independently for up to 3 heating periods
each day.
INTRODUCTION Cont...
If the engineer hasn’t set your timings for you, your programmer
will work with a standard program that has been set at the
factory. If this doesn’t suit you, it’s very easy to change it –
when you’ve read this introductory section, simply go to the
section that contains your programmer model.
Remember:
Make your changes using the SET?, YES/-, and + buttons on
the programmer.
You can’t set ON1 as the last timing before midnight, but you
can set OFF3 after midnight – providing it’s not more than 23
hours and 59 minutes after ON1.
You need to set the timings in sequence – i.e. ON1, OFF1, ON2,
OFF2, ON3, OFF3. If you get out of sequence, the display will
flash a warning.
SWITCHING
ON 1 – start of first timed period
OFF 1 – end of first timed period
ON 2 – start of second timed period
OFF 2 – end of second timed period
ON 3 – start of third timed period
OFF 3 – final switch-off of the day
The engineer has set your program and timings – you
won’t need to do anything else. Just keep this guide in a
safe place for future reference.
DAY-TO-DAY VARIATIONS
Sometimes you might need to change the way you use your
central heating or hot water temporarily – perhaps due to an
unusually cold day, or exceptional demand for hot water.
Here’s how to do it – without affecting your program.
Switching on and off
On the front of the programmer there are two Advance buttons
– one for central heating and one for hot water. They allow you
to switch either on or off, irrespective of the program. So if the
heating is off, and you want warmth now – press Advance to
switch it on, and it will stay on until the end of the next OFF
period. Or if the hot water is on and you don’t need it, press
Advance and it will go off until the beginning of the next ON
period.
Over-riding the program
On each side of the display there are four operating modes –
one group for central heating, the other for hot water. You can
change modes with immediate effect by using the appropriate
SELECT button. This won’t alter the timings in your program,
which you can return to by selecting TIMED.
OFF = continuously off.
TIMED = on for up to 3 periods a day.
ONCE = on for 1 period a day, from the start of ON1
to the end of OFF3.
ON = continuously on.
THE LP112 24hr ELECTRONIC PROGRAMMER
LP112 – a 24hr program, with linked central heating and hot
water on for up to 3 heating periods each day, and every day
the same.
If the timings haven’t been set for you, then your programmer
will still be on the factory-set standard 24hr program, with
central heating and hot water operating together on the
same settings for every day of the week. But it’s easy to
make changes – just follow the instructions.
Want to leave a timing as it is? Press SET? and move on to
the next one.
If you need to reset your timings to the standard program
and start again, press ‘SET’ and ‘+’ together to go back to
the pre-set program.
If you don’t press anything for two minutes, the programmer
automatically goes back to normal operation.
The standard program
Your system will come on for up to 3 heating periods every
24hrs. ON1 starts the first one, OFF1 finishes it, and so on.
Notice that on the standard program ON2 and OFF2 are set
to the same time.* This means your system won’t respond,
but if you want to activate that middle period, or change any
other timings – read on.
THE LP112 24hr ELECTRONIC PROGRAMMER Cont...
Changing the timings
Press the SET? button and you’ll see ‘SET PROG?’.
Press the YES button, and you’ll see ON1, the start of your first
heating period. Adjust it in 1-minute steps using the – and +
buttons. If the – and + buttons are held down, the time
changes in 10-minute steps.
Press SET?, and you’ll see OFF1, the end of your first heating
period. Adjust this in the same way, press SET?, then repeat the
procedure for ON2, OFF2, ON3 and OFF3.
When you press SET? after setting OFF3, the programmer will
return to normal operation.
THE LP241 24hr ELECTRONIC PROGRAMMER
LP241 – a 24hr program, with central heating and hot water
working independently for up to 3 heating periods each day,
and every day the same.
If the timings haven’t been set for you, then your programmer
will still be on the factory-set standard 24hr program, with
central heating and hot water operating together on the
same timings for every day of the week. But it’s easy to make
changes, and have heating and water working independently
– just follow the instructions.
Want to leave a timing as it is? Press SET? and move on to
the next one.
If you need to reset your timings to the standard program
and start again, press ‘SET’ and ‘+’ together to go back to
the pre-set program.
If you don’t press anything for two minutes, the programmer
automatically goes back to normal operation.
The standard program
Your system will come on for up to 3 heating periods every 24hrs.
ON1 starts the first one, OFF1 finishes it, and so on. Notice that on
the standard program ON2 and OFF2 are set to the same time for
both central heating and hot water. * This means your system won’t
respond, but if you want to activate that middle period, or change
any other timings – read on.
Changing the timings
Press the SET? button and you’ll see ‘SET PROG?’.
Set the central heating
Press the YES button, and the display will ask ‘SET CH PROG?’.
Press YES and you’ll see ON1, the start of your first central
heating period. Adjust it in 1-minute steps using the – and +
buttons. If the – and + buttons are held down, the time
changes in 10-minute steps.
Press SET?, and you’ll see OFF1, the end of your first central
heating period. Adjust this in the same way, press SET?, then
repeat the procedure for ON2, OFF2, ON3 and OFF3.
Set the hot water
When you press SET? after setting OFF3 for the central heating,
the display will ask ‘SET HW PROG?’.
Press YES, then set your times in the same way. Remember, in
this mode you can have different times to your central heating if
you wish.
When you press SET? after setting OFF3 for the hot water, the
programmer will return to normal operation.
Drayton Tempus 6, 7 (new models) N L 1 2 3 4
Lifestyle LP112, LP241, LP522, LP722 N L 1 2 3 4
Switchmaster 400, 600 N L 4 3 1
(no connection to terminal 4 on 600)
Switchmaster 805 N L 4 2 3 1
ACL MP (Towerchron) 2 1 6 10
ACL FP (Towerchron) 2 1 8 11 6 10
Drayton Tempus 3, 4, 6, 7 (old models) N L 1 2 3 4
Switchmaster 905, 9001 N L 4 2 3 1
Danfoss Randall
CP15, CP715,FP15, FP715 (Mk18
)ENL1234
Danfoss Randall 3020P, 3060 E 7 6 4 2
Danfoss Randall 4033 (link 1-6) E 7 6 5 3 4 2
Danfoss Randall 102, 102E, 102E5, 102E7 (link 6-3) E 5 6 1 2
Danfoss Randall 701 (link L-5 and 5-6) E N L 3 1
Danfoss Randall 702 (link L-5 and 5-6) E N L 4 2 3 1
Danfoss Randall 922, 972 (link L-2 and 2-5) E N L 1 4 3 6
Danfoss Randall SET2, SET2E, SET3E, SET3M, FP975 E N L 3 6 1 4
SET5 (link L-2 and 2-5)
Grasslin Towerchron DP 72, QE2 N L 1 2 3 4
Honeywell ST 699/799 (link L-5 and 5-8) N L 7 4 6 3
Honeywell ST 6200, ST 6300, ST 6400, ST 6450 N L 1 2 3 4
Honeywell ST 7100 (link L-3 and 3-6) N L 7 4 8 5
Horstmann 525, 527, 425 Diadem, H21, H27, E N L 3 6 1 4
H121, Tiara (link L-2 and 2-5)
Horstmann Centaur Plus, C21, C27 N L 1 2 3 4
Landis & Staefa* RWB2, RWB2E, 20, 40, 102, 200, N L 1 2 3 4
252 & 270, RWB9
Myson Microtimer (link L-5 and 5-8) N L 7 4 6 3
Potterton Myson All EP2000’s, EP3000’s, EP6000’s N L 1 2 3 4
(link L-5 and N-N)
Potterton Myson* Mini Minder N L 1 2 3 4
Sunvic Select 207 N L 1 2 3 4
Sunvic SP50, SP100 (link L-3) N L 1 4 2 5
Drayton Tempus 1, 2 (new models) N L 1 3 2 4
Lifestyle LP111, LP711 N L 1 3 2 4
Switchmaster 300 N L 4 1
ACL TC (Towerchron) 2 1 4 7
Drayton Tempus 1, 2 (old models) N L 1 2 3 4
Switchmaster 980 N L 4 1
Danfoss Randall TS15, 75 (Mk18) E N L 1 4 2 5/6
Danfoss Randall TS715 E N L 1 4 2 3
Danfoss Randall TS975 E N L 5 4 6 1,2,3
Danfoss Randall SET1, SET1E E N L 5 4 6
Danfoss Randall SET4 E N L 5 4 6
Danfoss Randall 103, 103E , 103E5, 103E7 4 5 6 3 1 2
Danfoss Randall 911, 971 E N L 5 6 4 2
Grasslin Towerchron QE1 N L 2 4 3
Grasslin Towerchron T2001, T2001Q E N L 7
Honeywell ST 6100A, ST 6100C N L 1 4 2
Honeywell ST 7000B L 3 2
Horstmann Centaur SC1, SC7 N L 4 3
Horstmann Centaur Plus, C11, C17 N L 2 4 3
Horstmann Emerald 423, Pearl Auto E N L 3 4
Horstmann 517, Coronet, H11, H17 E N L 5 4 6
Landis & Staefa RWB3 N L 4 3
Landis & Staefa RWB30, RWB50,100, 152, 170 N L 2 4 3
Landis & Staefa RWB7 N L 2 4 3 1
Potterton Myson EP4000, 4001, 4002, 5002 N L 5 4 2
Sangamo M6 E 4 6 3 1 2
Smiths Centroller Mk1, Mk2 N L 3 2
Smiths Centroller 30 1 2 4/5
Smiths Centroller 300, 980 N L 4 1
Sunvic Select 107 N L 1 3 2 4
Sunvic SP20, SP35 N L 3 5 4 S
Venner Vennerette N L LINE LOAD
DUAL
CHANNEL
LP112, LP241, LP522, LP722
SINGLE
CHANNEL
for heating OR hot water
LP111, LP711
Climate Controls Europe
Sales: 0845 1305522 / Technical Helpline: 0845 1307722
Email: customer.care@invensys.com / Web: www.draytoncontrols.co.uk
for heating AND hot water
Installation Instructions
06490033001 ISSC
DUAL
CHANNEL
LP112, LP241, LP522, LP722
SINGLE
CHANNEL
User’s Instructions
TIMESWITCHES
for heating OR hot water
LP111, LP711
Climate Controls Europe
Sales: 0845 1305522 / Technical Helpline: 0845 1307722
Email: customer.care@invensys.com / Web: www.draytoncontrols.co.uk
for heating AND hot water
User Instructions
06490033001 ISSC
INSTALLATION INSTRUCTIONS
PLEASE NOTE: INSTALLATION MUST ONLY BE
CARRIED OUT BY A QUALIFIED ELECTRICIAN OR
HEATING ENGINEER.
MAKE SURE MAINS INPUT HAS A 3 AMP FUSE.
TECHNICAL DATA
Lifestyle Programmers and Timeswitches conform to the
essential requirements of these Directives:
89/336/EEC – Electromagnetic compatibility
73/23/EEC – Low voltage
BEFORE INSTALLATION
First, make sure the mains supply is switched off!
PROGRAMMER ONLY
The programmer must be set to the type of system it is to control. The link on the back of the unit has two settings – P and G.
P = a fully pumped and controlled system – allowing
heating and hot water to be set separately.
G = a gravity-fed hot water system – which does not allow
independent setting of heating without hot water, though
hot water can be controlled alone.
USING AN EXISTING WALL-PLATE
Loosen the securing screws on the old programmer and
unplug it. Check that there’s 70mm clearance to the right of
the wall-plate, and 25mm above it. Check the chart on the
next page to compare terminals and if necessary, change the
wiring of the wall-plate to suit. Now plug the Lifestyle unit into
the wall-plate and tighten the securing screws.
Check the 3A fuse, and switch on the mains.
FITTING A NEW WALL-PLATE
The ideal location is 1.4m above floor level, with reasonable
lighting, good access, no condensation, no extremes of
temperature, and a supporting surface that fully covers the
back of the unit.
Position with 70mm clearance to the right, 25mm above, and
sufficient room to access the securing screws underneath.
Fix, with terminals at the top, either direct to a flat wall using wall
plugs and No. 6 x 1” (25mm) woodscrews, or on a flush mounting single conduit box type UA1 (BS4662) using M3.5 x 14 bolts.
DO NOT USE A SURFACE MOUNTING BOX.
TIMESWITCH TERMINAL COMPARISONS
Earth
Neutral
Live
Common
On
Off
Spare
MAKE MODEL
Current Models
PROGRAMMER TERMINAL COMPARISONS
Current Models
Earth
Neutral
Live
H/W off
C/H off
H/W on
C/H on
MAKE MODEL
Discontinued/Competitors’ Models
* Can simply be removed from the backplate and replaced without any disturbance to the existing wiring.
Discontinued/Competitors’ Models
WIRING THE TIMESWITCH
Make the wiring connections as
above. Note that the output
contacts are voltage-free, so
power needs to be put on to
Terminal 1 either by linking from
Terminal L or from a separate
supply with a 3A fuse.
WIRING THE PROGRAMMER
Arrowed numbers relate to
the junction box.
Consult boiler handbook
for details of pump
overrun wiring.
Connection Charts
Wiring Colour Codes
GR Grey
Y Yellow
BK Black
BL Blue
BR Brown
RD Red
W White
OR Orange
YG Yellow/Green
C Common
H Call for Heat
S Satisfied
N Neutral
E Earth
LLive
*Thermostat Key
USING A DRAYTON SIMP-L-FIT, ALTHOUGH NOT
NECESSARY, WILL MAKE THIS INSTALLATION EASIER.
SWITCHING
STANDARD PROGRAM
CH HW
ON 1 – start of first timed period 6.30am 6.30am
OFF 1 – end of first timed period 8.30am 8.30am
ON 2 – start of second timed period* 12.00pm 12.00pm
OFF 2 – end of second timed period* 12.00pm 12.00pm
ON 3 – start of third timed period 4.30pm 4.30pm
OFF 3 – final switch-off of the day 10.30pm 10.30pm
DAY-TO-DAY VARIATIONS Cont...
Over-riding the program
At the side of the display there are four operating modes:
OFF = continuously off.
TIMED = on for up to 3 periods a day.
ONCE = on for 1 period a day, from the start of ON1
to the end of OFF3.
ON = continuously on.
Use the SELECT button under the flap to change the mode.
This won’t alter the timings in your program, which you can
return to by selecting TIMED.
THE LP111 24hr ELECTRONIC TIMESWITCH
LP111 – a 24hr program, up to 3 heating periods each day,
and every day the same.
Want to leave a timing as it is? Just press SET? and move on
to the next one.
If you need to reset your timings to the standard program
and start again, press ‘SET’ and ‘+’ together to go back to
the pre-set program.
The standard program
Your system will come on for up to 3 heating periods every
24hrs. ON1 starts the first one, OFF1 finishes it, and so on.
Notice that ON2 and OFF2 are set to the same time.* This
means your system won’t respond, but if you want to activate
that middle period or change any other timings – read on.
SWITCHING STANDARD PROGRAM
ON 1 – start of first timed period 6.30am
OFF 1 – end of first timed period 8.30am
ON 2 – start of second timed period* 12.00pm
OFF 2 – end of second timed period* 12.00pm
ON 3 – start of third timed period 4.30pm
OFF 3 – final switch-off of the day 10.30pm
Changing the timings
Press the SET? button and you’ll see ‘SET PROG?’.
Press the YES button, and you’ll see ON1, the start of your first
heating period. Adjust it in 1-minute steps using the – and +
buttons. If the – and + buttons are held down, the time
changes in 10-minute steps.
Press SET?, and you’ll see OFF1, the end of your first heating
period. Adjust this in the same way, press SET?, then repeat the
procedure for ON2, OFF2, ON3 and OFF3.
When you press SET? after setting OFF3, the timeswitch will
return to normal operation.
THE LP711 7-DAY ELECTRONIC TIMESWITCH
LP711 – a 7-day program, allowing for different
timings on each day of the week, up to 3 heating periods
each day.
Want to leave a timing as it is? Just press SET? and move on
to the next one.
If you need to reset your timings to the standard program and
start again, press ‘SET’ and ‘+’ together to go back to the
pre-set program.
The standard program
Your system will come on for up to 3 heating periods every
24hrs. ON1 starts the first one, OFF1 finishes it, and so on.
Notice that ON2 and OFF2 are set to the same time.* This
means your system won’t respond, but if you want to activate
that middle period or change any other timings – read on.
SWITCHING
STANDARD PROGRAM
MON-FRI SAT-SUN
ON 1 – start of first timed period 6.30am 7.00am
OFF 1 – end of first timed period 8.30am 9.00am
ON 2 – start of second timed period* 12.00pm 12.00pm
OFF 2 – end of second timed period* 12.00pm 12.00pm
ON 3 – start of third timed period 4.30pm 4.00pm
OFF 3 – final switch-off of the day 10.30pm 11.00pm
LP112, LP241, LP522 & LP722 PROGRAMMERS
LP111 & LP711 TIMESWITCHES
Voltage 230V AC +10% - 10% 50Hz
Programmer Rating 2 (1) A 230V AC each switch
Timeswitch Rating 2 (1) A 230V AC
Ambient temp Operating: 0º to 45ºC
Storage: -20ºC to 50ºC
Without mains power Display: blank
Time: always kept
Program times: always preserved
Programming resolution 1 minute
Wiring Fixed wiring only, to comply with
current IEE regulations
Maintenance Must be maintained by a qualified
electrician or heating engineer
User’s Instructions
PROGRAMMERS
SWITCHING STANDARD PROGRAM
ON 1 – start of first timed period 6.30am
OFF 1 – end of first timed period 8.30am
ON 2 – start of second timed period* 12.00pm
OFF 2 – end of second timed period* 12.00pm
ON 3 – start of third timed period 4.30pm
OFF 3 – final switch-off of the day 10.30pm
INTRODUCTION
Lifestyle Timeswitches will automatically control your system
by switching it on and off at times that suit you. The red light
on the front of the timeswitch shows when it’s on.
LP111 – a 24hr program, up to 3 heating periods
each day, and every day the same.
LP711 – a 7-day program, allowing for different
timings on each day of the week, up to 3 heating periods
each day.
If the engineer hasn’t set your timings for you, your timeswitch
will work with a standard program that has been set at the
factory. If this doesn’t suit you, it’s very easy to change it –
when you’ve read this introductory section, simply turn to
the page for your timeswitch model.
Remember:
Make your changes using the SET?, YES/-, and + buttons.
You can’t set ON1 as the last timing before midnight, but you
can set OFF3 after midnight – providing it’s not more than 23
hours and 59 minutes after ON1.
You need to set the timings in sequence – i.e. ON1, OFF1, ON2,
OFF2, ON3, OFF3. If you get out of sequence, the display will
flash a warning.
SWITCHING
ON 1 – start of first timed period
OFF 1 – end of first timed period
ON 2 – start of second timed period
OFF 2 – end of second timed period
ON 3 – start of third timed period
OFF 3 – final switch-off of the day
If the engineer has set your program and timings – you won’t
need to do anything else. Just keep this guide in a safe place
for future reference.
DAY-TO-DAY VARIATIONS
Sometimes you might need to change the way you use your
system temporarily – perhaps due to an exceptionally cold day.
Here’s how to do it – without affecting the timings in your
program.
Switching on and off
On the front of the timeswitch is an Advance button. It allows
you to switch your system on or off, irrespective of the program.
Press Advance to switch it on, and it will stay on until the end
of the next OFF period. Turn it off, and it will stay off until the
beginning of the next ON period.
SINGLE
CHANNEL
Timeswitch
DUAL
CHANNEL
Programmer
Lifestyle
SINGLE
CHANNEL
Timeswitch
DUAL
CHANNEL
Programmer
Lifestyle
PROG?
PROG?
MON TUE WED THU FRI
PROG?
MON
PROG?
SETTING THE DATE Cont...
Set the month
Press SET? and the month will start to flash. Use the – and +
buttons to adjust.
Set the day
Press SET? and the day will start to flash. Use the – and + but-
tons to adjust.
Set the Day Light Saving
Press SET? and the current DLS status will start to flash for day
light saving (British Summer Time). Use the – and + buttons to
turn on or off.
Press SET? to go back to normal operation.
WEEKDAYS WEEKENDS
HW CH HW CH
ON 1 – start of first timed period 6.30am 6.30am 7.00am 7.00am
OFF 1 – end of first timed period 8.30am 8.30am 9.00am 9.00am
ON 2 – start of second timed period* 12.00pm 12.00pm 12.00pm 12.00pm
OFF 2 – end of second timed period* 12.00pm 12.00pm 12.00pm 12.00pm
ON 3 – start of third timed period 4.30pm 4.30pm 4.00pm 4.00pm
OFF 3 – final switch-off of the day 10.30pm 10.30pm 11.00pm 11.00pm
SWITCHING
WEEKDAYS WEEKENDS
HW CH HW CH
ON 1 – start of first timed period 6.30am 6.30am 7.00am 7.00am
OFF 1 – end of first timed period 8.30am 8.30am 9.00am 9.00am
ON 2 – start of second timed period* 12.00pm 12.00pm 12.00pm 12.00pm
OFF 2 – end of second timed period* 12.00pm 12.00pm 12.00pm 12.00pm
ON 3 – start of third timed period 4.30pm 4.30pm 4.00pm 4.00pm
OFF 3 – final switch-off of the day 10.30pm 10.30pm 11.00pm 11.00pm
SWITCHING
THE LP522 5/2-DAY ELECTRONIC PROGRAMMER
LP522 – a 5/2-day program allowing for different timings at
the weekends, with central heating and hot water working
independently for up to 3 heating periods each day.
If the timings haven’t been set for you, then your programmer
will still be on the factory-set standard program. This means
that central heating and hot water will operate together, with
the same timings for weekdays and different ones for the
weekend. But it’s easy to make changes, and have heating
and water working independently – just follow the instructions.
Want to leave a timing as it is? Press SET? and move on to
the next one.
If you need to reset your timings to the standard program
and start again, press ‘SET’ and ‘+’ together to go back to
the pre-set program.
If you don’t press anything for two minutes, the programmer
automatically goes back to normal operation.
The standard program
Your system will come on for up to 3 heating periods every
24hrs. ON1 starts the first period, OFF1 finishes it, and so on.
Notice that ON2 and OFF2 are set to the same time.* This
means your system won’t respond, but if you want to activate
that middle period, or change any other timings – read on.
Changing the timings
Press the SET? button and you’ll see ‘SET PROG?’.
Set the weekday central heating
Press the YES button, and the display will ask ‘SET CH MON to
FRI PROG?’.
Press YES and you’ll see ON1, the start of your first central
heating period. Adjust it in 1-minute steps using the – and +
buttons. If the – and + buttons are held down, the time
changes in 10-minute steps.
Press SET?, and you’ll see OFF1, the end of your first central
heating period. Adjust this in the same way, press SET?, then
repeat the procedure for ON2, OFF2, ON3 and OFF3.
Set weekday hot water
When you press SET? after setting OFF3 for the central heating,
the display will ask ‘SET HW MON to FRI PROG?’.
Press YES, then set your times in the same way. Remember, in
this mode you can have different times to your central heating if
you wish.
Set weekend central heating
When you press SET? after OFF3 for the weekday hot water,
the display will ask ‘SET CH SAT SUN PROG?’. Press YES to
confirm, and alter the times in the same way.
Set weekend hot water
When you press SET? after OFF3 for the weekend central
heating, the display will ask ‘SET HW SAT SUN PROG?’.
Press YES, and follow the procedure.
When you press SET? after OFF3 for HW SAT SUN, the
programmer will go back to normal operation.
PROG?
MON TUE WED THU FRI
CH
THE LP722 7-DAY ELECTRONIC PROGRAMMER
LP722 – a 7-day program allowing for different timings on each
day of the week, with central heating and hot water working
independently for up to 3 heating periods each day.
If the timings haven’t been set for you, then your programmer
will still be on the factory-set standard program. This has central
heating and hot water operating together – with the option of
having different timings for each day of the week. But it’s easy
to make changes, and have heating and water working
independently – just follow the instructions.
Want to leave a timing as it is? Press SET? and move on to the
next one.
If you need to reset your timings to the standard program and
start again, press ‘SET’ and ‘+’ together to go back to the
pre-set program.
If you don’t press anything for two minutes, the programmer
automatically goes back to normal operation.
The standard program
Your system will come on for up to 3 heating periods every
24hrs. ON1 starts the first period, OFF1 finishes it, and so on.
Notice that ON2 and OFF2 are set to the same time.* This
means your system won’t respond, but if you want to activate
that middle period, change any other timings – read on.
Changing the timings
Press the SET? button and you’ll see ‘SET PROG?’.
Set all weekdays
First you set the times that are going to be the same for each
weekday, then you can select each day individually and make
any further adjustments. If you want each day to be quite different, go straight to ‘Set each day.’
Press the YES button, and the display will ask ‘SET MON to FRI
PROG?’.
Press YES and the display will ask ‘SET CH MON to FRI
PROG?’.
Press YES, and you’ll see ON1, the start of your first central
heating period. Adjust it in 1-minute steps using the – and +
buttons. If the – and + buttons are held down, the time
changes in 10-minute steps.
Press SET?, and you’ll see OFF1, the end of your first central
heating period. Adjust this in the same way, press SET?, then
repeat the procedure for ON2, OFF2, ON3 and OFF3.
When you press SET? after setting OFF3 for the weekday cen-
tral heating, the display will ask ‘SET HW MON to FRI PROG?’.
Press YES, then set your hot water times in the same way.
Remember, in this mode you can have different times to your
central heating if you wish.
Set each day
If, after you’ve set OFF3 for your hot water, you want to fine-tune
one or more weekdays, press SET? until you find the first day
you want to adjust – then go through the procedure, altering any
time you wish. Press SET? to move on to the next day. When
you’ve finished, press SET? until you see ‘SET SAT SUN
PROG?’.
If you don’t want to alter any individual days, keep pressing
SET? until you see ‘SET SAT SUN PROG?’.
PROG?
MON TUE WED THU FRI
CH
PROG?
MON TUE WED THU FRI
Climate Controls Europe
Sales: 0845 1305522 / Technical Helpline: 0845 1307722
Email: customer.care@invensys.com / Web: www.draytoncontrols.co.uk
USERS NOTES
THE LP722 7-DAY ELECTRONIC PROGRAMMER Cont...
Set weekend
Press YES, and alter the central heating and hot water times in
the same way.
When you press SET? after OFF3 for HW SAT SUN, the pro-
grammer will ask the question TEST? If you want to test your
program, see below, otherwise press SET? again. If you don’t
want to test your program, press SET? again – and you’ll be
asked the question SET H’DAY? If you want to set a holiday
switch off, see page 23, otherwise press SET? again.If you’re
not going to program in a holiday switch-off, then press SET?
again and your programmer will go back to normal operation.
Test your program
This test facility allows you to run through your program to
check that the timings are exactly what you want.
Answer YES to TEST? and the display will show Monday and
a time just past midnight. Press YES again and hold it down –
and the display will start to run through the days of the week,
pausing for a few seconds when it reaches an ON or an OFF
time. At each pause, the appropriate lights and circuits will
come on.
Release the YES button, and the display will stop running
and give you longer to identify a timing.
Press YES once more, and the display will start running again –
and will continue all through the week until you press SET?
Press SET? and your programmer will go back to normal
operation.
Remember - The display shows the strict time sequence, so
ON1 for HW could be followed by ON1 for CH, then OFF1 for
HW etc.
Set a holiday switch-off
Using this feature you can program your system to switch off
while you’re on holiday, then switch back on again in time to
have the house warm for your return.
Press SET? three times and you’ll see ‘SET H’DAY?’
Press YES to SET H’DAY? and the display will show ‘00’.
Using + and -, set the number of days you want the system to
be off.
Press SET, the display will show ‘H’DAY’ and the programmer
will switch off the system. It will then return to normal operation
after the set number of days.
Remember - The programmer counts each pass through
midnight as a day. So if on a Saturday morning you don’t want
the heating on again until Tuesday morning, set for 3 days.
SETTING THE CLOCK AND DATE
Applicable to all models.
SETTING THE CLOCK
The clock in your programmer has been set at the factory,
and automatically accounts for British Summer Time.
However, should you need to set the clock, read on.
Press the SET? button until you see SET CLOCK?.
Set the hour
Press YES once, and then the hour will start to flash. Use the
– and + buttons to set the hour, checking for AM and PM.
Set the minute
Press SET?, and the minutes will start to flash. Use the – and +
buttons to set the exact time.
Press SET?, and ‘SET DATE?’ appears in the display.
If you don’t want to change the date press SET? to go back to
normal operation. If you do, go on to the next section.
SETTING THE DATE
The weekday is automatically calculated from the date, so if
the weekday is incorrect you’ll need to reset the date.
Press the SET? button until you see SET DATE?.
Set the year
Press YES and the year will start to flash. Use the – and + but-
tons to adjust.
E L N C H
N L 3
L N 1 3
E 4 1 2
#
3
L
N
1
L
2
L11 2 374
4
N
E
1
2
3
124 5
ROOM THERMOSTAT
PROGRAMMER PUMP
JUNCTION BOX
LWC3
SET TO
'G'
Gravity HW, Pumped CH with Room Stats
RTS 1&2
RTS 4,5&6
ETS 1
#- LINK L-1 FOR 230V OUTPUT
Switched and Fused
(3A) Mains input
For pump overrun boilers consult
manufacturer's instructions
†
See Thermostat Key
*
E
N
L
3
2
5
BOILER
E
N
L
3
2
7
2N3E4 5 6 7 8 9 10 1112
E L N C H
N L 3
L N 1 3
E 4 1 2
#
W GR OR BL YG
3
L
N
1
58723
L
2
L
1
8
1 2 364
4
N
E
1
2
3
124 5
ROOM THERMOSTAT
PROGRAMMER
PUMP
JUNCTION BOX
LIFESTYLE 679H340-30L0 (22mm)
LIFESTYLE 779H340-30L0 (28mm)
DRAYTON FLOWSHARE 2
Honeywell
V4073A
Landis & Gyr
MAV 3
LWC3
SET TO
'P'
HTS 3
Mid-Position Valve System
RTS 1&2
RTS 4,5&6
ETS 1
#- LINK L-1 FOR 230V OUTPUT
Switched and Fused
(3A) Mains input
For pump overrun boilers consult
manufacturer's instructions
†
†
See Thermostat Key
*
*
E
N
L
3
2
7
CYLINDER THERMOSTAT
BOILER
E
N
L
3
2
7
2
8
6 7
C1
SCH
2N3E4 5 6 7 8 9 1011 12
MID-POSITION VALVE
WIRING THE PROGRAMMER Cont...
Connection Charts
Make the wiring connections, as above, for the appropriate system.
For surface wiring, snap out the cable entry strip on the bottom edge
of the wall-plate. Lifestyle units are double-insulated and need no earth
connection, but an earthing continuity (loop) terminal is provided for
convenience.
After wiring, plug in the unit and tighten the securing screws.
Check the mains input has a 3A fuse, and switch on the mains.
Then set the timings as shown in the User’s Guide.
ALWAYS SWITCH OFF THE MAINS BEFORE REMOVING
THE LIFESTYLE TIMESWITCH/PROGRAMMER – AND
NEVER FIT IT TO A LIVE WALL-PLATE!
HTS 3
†
E L N C H
N L 3
L N 1 3
E 4 1 2
#
3
L
N
1
L
2
L11 2 364
4
N
E
1
2
3
124 5
ROOM THERMOSTAT
PROGRAMMER
PUMP
JUNCTION BOX
LWC3
SET TO
'P'
Spring-Return 2-Valve System
RTS 1&2
RTS 4,5&6
ETS 1
#- LINK L-1 FOR 230V OUTPUT
Switched and Fused
(3A) Mains input
For pump overrun boilers consult
manufacturer's instructions
†
See Thermostat Key
*
*
E
N
L
3
2
7
CYLINDER THERMOSTAT
BOILER
E
N
L
3
2
7
2
8 6
C1
SCH
2N3E4 5 6 7 8 9 101112
GR OR BR BL YG
17523
LIFESTYLE 679H308-30L1
LIFESTYLE 779H33530L10
DRAYTON ZV22
Honeywell
V4043H1056
Landis & Gyr
ZAV222
CH VALVE
GR OR BR BL YG
17823
DHW VALVE
Climate Controls Europe
Sales: 0845 1305522 / Technical Helpline: 0845 1307722
Email: customer.care@invensys.com / Web: www.draytoncontrols.co.uk
INSTALLERS/ENGINEERS NOTES