ETHYLENE GLYCOL
ANTIFREEZE
TESTER
35807 – AFT-4B INSTRUCTIONS FOR USE
Read this manual in full before attempting to use the
product and retain it for later use.
1. Scope
This product can be used to determine the level of
protection provided by ethylene glycol vehicle coolant
solutions. Protection is dependent on the ratio of
water and antifreeze chemicals present in the solution.
Measuring range: -37 to -7°C
2. Health and Safety Instructions
Important: Refer to the vehicle manufacturer’s
manual or the appropriate Haynes workshop manual
before EVERY use.
WARNING! Antifreeze solution is toxic; ALWAYS
read the label. If it comes into contact with your
eyes or skin, immediately ush with plenty of water.
If it is swallowed, drink plenty of water. In all cases,
and seek medical attention immediately.
• ALWAY S wear suitable protective gloves and
goggles when working with antifreeze solution.
• Clear any spillage immediately and with care.
• Wash the tester thoroughly after every use.
• Keep out of reach of children.
Important: ALWAYS dispose of antifreeze and coolant
solutions in accordance with local regulations.
(DISC TYPE)
June 2022
3. Operation
Important: Read the Health and Safety information
before attempting to use this product. ALWAYS allow
the radiator to cool before removing the cap.
To avoid separation of the coolant solution, test the
solution while hot, after bringing the vehicle up to
temperature and then allowing the radiator to cool.
1. Run the vehicle engine to normal temperature if
necessary to mix fresh coolant.
2. Carefully remove the radiator cap using a cloth
and gloves.
WARNING! ALWAYS allow the radiator to
cool before opening it. The cooling system may
still be pressurised when opened and emit hot
steam, which can cause burns.
3. Insert the tester tube into the radiator reservoir
and squeeze the rubber bulb to draw uid into the
tester so that it is almost full.
Important: If the coolant solution is dirty or rusty,
drain, ush and rell the radiator, then clean the
tester and redraw the solution to the uid line.
4. Remove the tube from the reservoir and squeeze the
bulb lightly to expel any air bubbles from the uid.
5. Allow the discs to settle and observe the number of
discs that are oating (see below).
6. Flush the tester with hot soapy water and rinse clean
with warm water after use.
EN
Version 2

4. Disposal
At the end of its working life, dispose of the product responsibly and in line with local regulations.
Recycle where possible.
5. Explanation of Symbols
Read the instruction
manual
Wear protective goggles
UK Conformity Assessed
WARNING!/CAUTION
Wear protective gloves
European conformity
Number of oating discs Meaning Required action
0 Minimal or no protection
1 Protected to -7°C
2 Protected to -15°C
Replace the coolant with a higher
concentration of antifreeze
3 Protected to -23°C
No action required4 Protected to -31°C
5 Protected to -37°C
6
Helpline: +44 (0) 23 8049 4344
Website: drapertools.com
Draper Tools Limited, Hursley Road, Chandler’s Ford, Eastleigh, Hampshire, SO53 1YF, UK 0822
Unsafe solution – excessive antifreeze can
cause corrosion and increase the boiling
point of the solution.
Sales Desk: +44 (0) 23 8049 4333
Email: sales@drapertools.com
Replace the coolant with a lower
concentration of antifreeze.
General Enquiries: +44 (0) 23 8026 6355