Draper Signature E Series, E, V, Signature V Series Installation & Operating Instructions Manual

Installation/Operating Instructions
Signature/Series E & V Electric Projection Screen by Draper
Read instructions through completely before proceeding. Follow instructions carefully. Installation con trary to instructions invalidates
warranty. Entire bottom of screen case should be unobstructed to permit proper operation of automatic trap door, and access to bottom panel for making electrical connections or servicing.
Screen should be installed level (using a carpenter’s level). Nothing should be fastened to screen dowel or viewing surface. Operating switch(es) is packed separately in screen carton. Do not discard
with packing material. Screen operates on 110-120V, 60 Hz., 1.1 amp current draw for models using small case; 1.3 for models using large case (see page 2). NOTE: Screen has been thoroughly inspected and tested at factory and found to be operating properly prior to shipment.
These instructions are meant as a guide only. They do not imply any re spon si bil i ty on the part of Draper, Inc. for improper in stal la tion or faulty work man ship at the jobsite.
Hanging Screen
Caution
When locating viewing surface and checking clear ance for screen’s op er a tion, remember surface is centered in case. Screen is normally recessed above ceiling and may be installed in a variety of ways. See typical installations detailed on back of this sheet. Regardless of mounting method used, the following points apply:
Screen should be lifted into position only by the end mounting brackets. Keep case level by lifting end plates simultaneously to prevent surface damage. Draper provides eyebolts to use in hoisting the screen. Never attempt to lift screen along its length.
Screen should be positively and securely supported so that vibration or even abusive pulling on viewing surface will not weaken installation. Installer must insure that fasteners used are of adequate strength and suitable for the mounting surface chosen.
Entire bottom of case must be readily accessible after installation is complete. Hinge that connects bottom panel and automatic trap door of screen must be
permitted to operate freely. Front and back of case must be straight—not forced to warp or bow. Hinges must be free from mastic or paint buildup, and doors must be unobstructed by ceiling tiles.
Do not use screen case to support adjacent sections of ceiling. If trim pieces must be attached to case, do not permit screws to protrude more
1
than
/4" through 1/8" wall of case. Do not attach trim pieces with nails. If case is painted, slots on bottom of case should be shielded to protect viewing surface from paint splatters or overspray. Do not seal unit in ceiling until electrical connections have been made and screen has been operated successfully.
Suitable for use in environmental air space in accordance with Section 300-22(c) of the National Electrical Code, and Sections 2-128, 12-010(3) and 12-100 of the Canadian Electrical Code, Part 1, CSA C22.1.
Electrical Connections
Screen operates on 110-120v, 60 Hz., 1.1 amp current draw for models using small case; 1.3 for models using large case (see page 2). Junction box is located just above the access plate at left end of screen. (See chart on back of this sheet.) Access plate is held closed with fl athead screws and may be opened with a Phillips screwdriver. (Au to mat ic trap door does not need to be opened to make fi eld con nec tions.) Removal of access plate exposes red, black and white pigtail leads and green internal ground wire per wiring diagram attached. Screen is shipped with internal wiring complete and control switch(es) fully boxed. Wire connecting screen to switch(es) and switch(es) to power supply should be furnished by installer. Connections should be made in ac cor dance with attached wiring diagram, and wiring should comply with National and local electrical codes.
All Operating Switches Should Be “Off” Before Power Is Con nect ed.
Operation
CAUTION—Important Instructions—Signature/Series V—The shipping
sup port brack et must be removed from the dowel during initial operation before screen is operated in UP direction. After screen is in stalled, run viewing surface DOWN to access and remove bracket. Signature/Series E—The protective paper wrapping around the viewing surface must be removed before the screen is op er at ed in down direction. Cycle view ing sur face down and up several times
®
Copyright © 2009 Draper Inc. Form SignatureE&V_Inst09-R2 Printed in U.S.A.
to con fi rm sat is fac to ry op er a tion. If viewing surface or trap door do not operate properly, turn power off and free trap door and/or check electrical con nec tions. When screen is fi rst operated, be cautious! If automatic trap door does not open immediately up into screen case when switch is fl ipped “down”, return switch to “off” and free trap door and/or recheck electrical con nec tions before proceeding. Cycle unit down and up several times to confi rm sat is fac to ry operation. 110-120V Single Station Control—3-position UP-OFF-DOWN switch per mits op er a tion to be stopped at any point. Factory adjusted limit switches au to mat i cal ly stop screen when fully down or fully up. 110-120V Multiple Station Control—Switches are similar in ap pear ance to 110-120V Single Station Control. Screen stops when switch is re leased and may be restarted in either direction. Factory adjusted limit switches stop screen automatically when fully up or fully down. 24V Control—Three-button UP-STOP-DOWN switches stop at any point desired, operate in any sequence. Factory adjusted limit switches au to mat i cal ly stop screen when fully up or fully down. Wireless controls—whether infrared or radio frequency—interface with the low voltage control box. (See wiring diagram on reverse.) Key Operated Switching—Two kinds of key-operated switches are op tion al ly available with this unit. The key-operated power supply switch controls power to the screen and switches. When it is “off”, the switches will not operate screen. Key may be removed from the switch in either “on” or “off” position. A three-position key switch permits the screen to be op er at ed directly by key. In this case, the screen’s operator must always have a key. RS232/Ethernet—Serial communication and network communication optionally available with wall switches, RF or IR remote.
Limit Adjustments
Tools needed: Flashlight, small fl athead screwdriver/Allen wrench (4mm or 5/32"). Screen settings have been factory set as ordered and should not normally require further adjustment. However, if you fi nd it necessary to adjust for more or less viewing area, proceed as follows.
CAUTION: Always be prepared to shut screen off manually when new adjustment is being tested. Screen may be severely damaged if viewing surface is allowed to run too far up or too far down. When running up, the dowel should never wrap over the roller. When run to the down limit, a minimum of 1¼ wraps of fabric must remain on the roller.
The motor limit screws are normally located on the audience left of screen roller.
"Down" Limit Adjustment
To Reduce Screen Drop
Raise screen surface about 1' above desired setting and turn off. Turn the WHITE/DOWN limit screw clockwise (three screw turns = ½ roller
revolution). Test by running screen down and repeat steps 1 and 2 until desired position is reached.
To Increase Screen Drop
Run screen to the down limit. With the down switch on, turn the WHITE/DOWN limit screw counterclockwise
(three turns of screw = ½ roller revolution) to increase drop.
Test by running screen up about 1' and back down to new down limit. Repeat steps 2 and 3 until desired position is reached.
CAUTION: At least 1¼ wraps of fabric must remain on the roller when
screen is at the down limit!
"Up" Limit Adjustment
Screen is Running Too Far Up
Lower screen surface about 1' below desired setting and turn off. Turn the YELLOW/UP limit screw clockwise (three screw turns = ½ roller
revolution).
Test by running screen up. Repeat steps 1 through 3 until desired position is reached.
Screen Needs to Run Up More
Run screen down about 1' and turn off. With the up switch on, turn the YELLOW/UP limit screw counterclockwise (three
turns of screw = ½ roller revolution). Repeat steps 1 and 2 until desired position is reached.
CAUTION: Do NOT allow the dowel to wrap up over the roller when the
screen is running up! This could damage the screen.
Please Note: Instructions for adjusting Draper’s Tab-Tension System for Series V screens are on page 2.
If you encounter any diffi culties installing or servicing your Signature, call your dealer or Draper, Inc., Spiceland, Ind., (765) 987-7999 or fax (765) 987-7142.
Signature/Series E & V by Draper
9
V
V
Case Dimensions & Methds of Installation
1
/2" Typ
1
A
Series A
E-small case 33/16"
/8"
E-large case 41/2" V Varies
1
2
NOTE: Viewing surface shown is Series V with tab tensioning.
Series E, without tab tensioning, is also available.
Small Signature Case
Shown with
3
/8" threaded
rod (provided
by others).
Electrical connection to internal splice box
on left end of case.
knockout for 1/2" conduit.
J-Box cover located under
splice box.
7
9¾"
/8"
6"
91/8"
Large Signature Case
Shown with
3
/8" threaded
rod (provided
by others).
6"
11"
Electrical connection to internal splice box
on left end of case.
knockout for 1/2" conduit.
J-Box cover located under
splice box.
7
/8"
91/8"
SCREEN SIZE CASE SIZE
Total Drop <156" or viewing width <144" Small Total drop >156" or viewing width >144" Large
Two-Way Serial Communication (RS232) with MC1
See separate Serial Communication-RS232 Instruc­tion sheet for enabling RS232 with the MC1.
Program LED
Fuse
MC1
Case length
Viewing surface
Audience
Ceiling grid and tile
(by others)
Audience
Ceiling grid and tile
(by others)
White-Common to screen & 110-120V AC Neutral Red-to Screen (directional) Brown-to Screen (directional) Black-Hot to 110-120V AC Green/Yellow-Ground
Low Voltage Wiring by others AC Wiring by electrician
RS232 Data FROM Control System RS232 Data TO Control System Signal Ground & Manual Switch Common Manual Switch Down Manual Switch Up
Eye Port for IR Eye. For RF Receiver or LED Wall Switch, a Splitter and a Power Supply is required. Plug RF Receiver or LED Wall Switch and Power Supply into splitter, then run cable from Splitter to MC1 Eye Port.
www.draperinc.com
Please Note: Do not wire motors in parallel.
Single Station Control
To 110-120V Line
STOP
STOP
Control Switches 24v DC
Ceiling grid
and tile
(by others)
Dashed wiring by electrician
Blue
Red
Location of key operated on-off switch if furnished
Internal Screen Wiring
White (Common) Red (Up) Black (Down) Green (Ground)
To
110-120
Line
Location of key operated on-off switch if furnished
Page 2 of 2
Tab-Tension Adjustment
Procedure for Signature/Series V
Determine which side requires adjustment. Secure dowel with one hand.
Caution: Do not touch or bend surface.
Using Philips-head screwdriver, depress spring-loaded adjustment screw (see drawing) and slowly turn clockwise to tighten tension, or
Dowel
counterclockwise to loosen tension. The screw adjusts in ¼ turn increments. Adjust only one increment (¼ turn). If problem is not corrected, leave screen in position for 24 hours to allow surface material to stretch into position. If problem still is not corrected, repeat steps 2 and 3.
Wiring Diagrams
Multiple Station Control
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green (Ground)
Control
Single gang box by others
switch
Min. 4" x 2
Black
1
/8" x 1
7
/8" deep
Red
Red
Location of key operated on-off switch if furnished
To 110-120V Line
Red
Black
Black
Black
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green (Ground)
Cap off with wire nut and tape
Blue
Blue
Blue
Single gang box by others Min. 4" x 2 3 shown. More or less equally feasible.
Low Voltage & Wireless Control
White-Common to screen & 110-120V AC Neutral Red-to screen (directional) Brown-to screen (directional) Yellow-to 110-120V AC-Hot Black-to 110-120V AC-Hot Green-Ground
Dashed wiring by electrician
Low voltage wiring by others
Eye Port for IR Eye, RF Receiver or LED Wall Switch. For more than one of these, a splitter is required.
3 Button Wall Switch DOWN - Black COM - White UP - Red
Aux Port for connecting additional LVC-III modules (up to six total can be linked­connect from Aux to Eye).
Caution: Do not remove the roller assembly from the case unless necessary for repairs. If the roller assembly is removed, be sure mo­tor is fully re-seated in the bracket, and re-secure it carefully with the motor retaining spring and screw (see diagram below).
Please note: Maximum torque for tightening screw is 5 lb-inches.
(765) 987-799
Tensioning Cable
Dashed wiring by electrician
1
7
/8" x 1
/8" deep.
Internal Screen Wiring
STOP
Location of key operated on-off switch if furnished
STOP
Control Switches 24v DC
Adjustment Screw
White (Common) Red (Up) Black (Down) Green (Ground)
To
110-120
Line