Draper Ultimate Access Series E, Ultimate Access Series V Installation & Operating Instructions Manual

Installation/Operating Instructions
®
Ultimate Access Series E & V Electric Projection Screen by Draper
Caution
1 Read instructions through completely before proceeding. 2 Follow instructions carefully. Installation contrary to instructions
invalidates warranty. 3 Entire bottom of screen case should be unobstructed to permit access to bottom panel for electrical connections or servicing.
4 Screen should be installed level (using a carpenter’s level). 5 Nothing should be fastened to screen dowel or viewing surface. 6 Operating switch(es) and mounting brackets are packed separately
in screen carton. Do not discard with packing material. 7 Screen operates on 110-120V, 60 Hz. AC, 1.1 amp current draw.
NOTE: Screen has been thoroughly inspected and tested at factory and found to be operating properly prior to shipment.
These instructions are meant as a guide only. They do not imply any responsibility on the part of the manufacturer for improper installation or faulty workmanship at the jobsite.
Hanging Screen
When locating viewing surface and checking clearance for screen’s operation, remember surface is centered in the length of the case. Screen is normally recessed above ceiling with the motor on the left (as the audience sees the screen). For reverse roll screens, install headbox with motor on the right. See typical installations detailed on page 3 of this sheet. Regardless of mounting method used, the following points apply: 1 Mounting brackets are packed separately in carton. Engage each bracket with top of housing as shown below and tighten set screws. Bracket should be within 8" from each end of screen case. Brackets can be removed and case mounted with lag screws through top of case (holes drilled on site). 2 Screen should be positively and securely supported so that vibration or even abusive pulling on viewing surface will not weaken installation. 3 Installer must insure that fasteners used are of adequate strength and suitable for the mounting surface chosen. 4 Entire bottom of case must be readily accessible after installation is complete. 5 The bottom access panel, trap door, and lower edge of the case are joined with continuous hinge joints and must operate freely. Front and back of case must be straight–not forced to warp or bow. Hinge joints must be free of mastic or paint build up, and trapdoor and access panel must be unobstructed by ceiling tiles. 6 If case is painted on location, removal of roller/fabric assembly is recommended prior to painting. If not removed, slots on bottom of case
Dowel
Remove shipping brackets before operating screen.
Slots along top of case permit
Shipping Bracket
brackets to be set at an angle Typical Installation
Case dimensions
Alternate
on page 4.
Installation (additional set of brackets required but not included)
7
/8" electrical cutout
US Patent Nos. 5,341,241; 6,137,629; 6,421,175; 6,532,109; 6,816,308; 7,559,707
should be shielded to protect viewing surface from paint splatters or overspray. 7 Do not seal unit in ceiling until electrical connections have been made and screen has been operated successfully.
Electrical Connections
Screen operates on 110-120V, 60 Hz., 1.1 amp current draw. Junction box is located just above the bottom access panel at the left end of the screen. Open the access panel/trap door for access to the junction box cover. (See bottom access panel/trap door opening and closing instructions below). Remove two (2) hex head screws that secure the cover to the junction box to expose the red, black, and white pigtail leads and the green ground wire per wiring diagram on page 3. If optional low voltage control or video interface control is specified and factory installed, please refer to wiring diagrams on page 4. Screen is shipped with internal wiring complete and control switch(es) fully boxed. Wire to connect screen to switch(es) and switch(es) to power supply should be furnished by installer. Connections should be made in accordance with attached wiring diagram, and wiring should comply with national and local electrical codes.
All operating switches should be “off” before power is connected.
Bottom Access Panel/Trap Door Opening & Closing
After screen case has been mounted, remove the dowel shipping brackets from dowel if provided. A spring latch at each end of the trap door holds
this assembly closed. In some screens there will also be a spring latch near the center of the case. To gain access to inside of screen case,
disengage spring latch at each end of the case (and near the center of the case, if applicable) by sliding the latch lever towards the center of screen case, then pull down slightly on the trap door assembly. The latch levers are somewhat concealed from view. Locate these with the trap door open by feeling for the vertical latch lever above the door about 3" from case endcaps and near the center of the case. The assembly will swing down, opening about 135°. Pivot the prop arms at each end of the trap door assembly towards the ends of screen case. Prop arms engage with a hole in each endcap to hold the trap door assembly fully open. To close the trap door assembly disengage prop arms from endcaps and pivot these over the access panel. Swing the trap door assembly upward, stopping just before the latch levers hit the bottom flanges of the endcaps (and center of case where appropriate). Pull levers of latches towards center of screen case to allow the trap door assembly to be pivoted to its closed position. Make sure that the spring latch levers engage fully with case endcaps (and center of case where appropriate).
Caution: Beware of pinch
points along closure
Copyright © 2013 Draper Inc. Form UltimateAccess_Inst13 Printed in U.S.A.
Suitable for use in environmental air space in accordance with Section 300-22(c) of the National Electrical Code, and Sections 2-128, 12-010(3) and 12-100 of the Canadian Electrical Code, Part 1, CSA C22.1.
If you encounter any difficulties installing or servicing your Ultimate Access screen, call your dealer or Draper, Inc., in Spiceland, Indiana, 765/987-7999 or fax 765/987-7142.
Ultimate Access Series E & V by Draper Page 2 of 4
Motor roller assembly
Retaining clip
Washer
Idler end roller mounting bracket
Dowel
Adjustment Screw
Te nsioning Cable
www
9
Motorized Roller/Fabric Installation
The bottom access panel/trap door assembly must first be opened and placed in fully opened position.
The motor end mounting bracket has a metal bracket with snap ring for accepting motor head. Back out the four set screws in bracket until they are flush with top side of bracket.
To engage the motor end bracket flange above the two channels in the top of the screen housing, rotate the bracket approximately 45° counterclockwise to allow the top surface of the motor bracket to rest flat against the top inside of the housing. Rotating the bracket clockwise until it is engaged with the channels, slide it along the length of the housing against the electrical junction box.
Engage the idler end bracket (rectangular mounting pad) in the same manner as the motor end bracket and slide it toward the opposite end of the screen housing. Do not tighten the set screws on the brackets until the roller/fabric assembly is installed, and centered in the case.
Locate the black washer and retaining clip.
Note: This will require two people to perform safely. Raise the roller/fabric
assembly up into the screen housing and engage the head of the motor
completely into the motor mounting bracket, making sure the snap ring engages with the motor and that the limit
switch adjusting knobs are visible from the bottom of the screen housing.
While supporting the idler end of the roller, slide the idler end mounting bracket toward the roller. Insert the roller pin into the nylon bushing on the idler end mounting bracket.
The roller idler pin needs to go through the idler bracket far enough to allow the washer and retaining clip to be reinstalled on the pin.
Failure to replace the washer and retaining clip as shown could result in the separation of the roller from the brackets.
The roller/fabric assembly and roller brackets may need to be slid left or right in mounting channel of case to center fabric within screen case.
Securely tighten the set screws on the roller mounting brackets.
Connect the electrical plug from the motor to the mating socket on the junction box.
Close the bottom access panel/trap door as previously described.
automatically. Two versions: Model VIC-115 integrates screen operation with a DRAPER video projector lift or a video projector or tuner with a 110-120V switched outlet. Model VIC-12 interfaces with 12V switched outlet. Both available with override switch (VIC–OS), permitting independent operation. VIC–OS not available with factory installed VIC-115 & VIC-12. KEY OPERATED SWITCHING—Two kinds of key-operated switches are optionally available with this unit. 1 The key-operated power supply switch controls power to screen and switches. When it is “off”, the switches will not operate screen. Key may be removed from the switch in either “on” or “off” position. 2 A three-position key switch permits screen to be operated directly by key. In this case, the screen’s operator must always have a key. RS232/Ethernet—Serial communication and network communication optionally available with wall switches, RF or IR remote.
Limit Adjustments
Please Note: Screen limits are factory set for optimum performance of the screen. A procedure is outlined below for minor tweaks, but any adjustment of these limits may negatively affect the flatness of the screen surface and could also void the warranty. Please check with Draper prior to resetting screen limits.
CAUTION: Always be prepared to shut screen off manually when new adjustment is being tested. Screen may be severely damaged if viewing surface is allowed to run too far up or too far down.
CAUTION: Be sure all switches are in “off” position before adjusting
limit switches.
The motor limit screws are normally located on the audience left of screen roller.
"DOWN" LIMIT ADJUSTMENT
To Reduce Screen Drop
1 Raise screen surface about 1' above desired setting and turn off. 2 Turn the WHITE/DOWN limit screw clockwise (three screw turns = ½ roller
revolution). 3 Test by running screen down and repeat steps 1 and 2 until desired position is reached.
To Increase Screen Drop
1 Run screen to the down limit. 2 With the down switch on, turn the WHITE/DOWN limit screw counter-
clockwise (3 turns of screw equals ½ roller revolution) to increase drop.
3 Test by running screen up about 1' and back down to new down limit. 4 Repeat steps 2 and 3 until desired position is reached.
"UP" LIMIT ADJUSTMENT
Screen is Running Too Far Up
1 Lower screen surface about 1' below desired setting and turn off. 2 Turn the YELLOW/UP limit screw clockwise (three screw turns = ½ roller
revolution).
3 Test by running screen up. 4 Repeat steps 1 through 3 until desired position is reached.
Screen Needs to Run Up More
1 Run screen down about 1' and turn off. 2 With the up switch on, turn the YELLOW/UP limit screw counterclockwise
(three turns of screw = ½ roller revolution). 3 Repeat steps 1 and 2 until desired position is reached.
CAUTION: Do NOT allow the dowel to wrap up over the roller when the screen is running up! This could damage the screen.
Motorized Roller/Fabric Removal
Reverse the instructions above “Motorized Roller/Fabric Installation” for removal of the unit.
Operation
When screen is first operated, be cautious! Cycle unit down and up several times to confirm satisfactory operation. 110-120V SINGLE STATION CONTROL—3-position UP-OFF-DOWN switch permits operation to be stopped at any point. Factory adjusted limit switches automatically stop screen when fully down or fully up. 110-120V MULTIPLE STATION CONTROL—Switches are similar in appearance to 110-120V Single Station Control. Screen stops when switch is released and may be restarted in either direction. Factory adjusted limit switches stop screen automatically when fully down or fully up. 24V MULTIPLE STATION CONTROL—Three-button UP-STOP-DOWN switches stop at any point desired, operate in any sequence. Factory adjusted limit switches automatically stop screen when fully down or fully up. 110-120V & 12V VIDEO INTERFACE CONTROL—Allows screen to be controlled by a trigger signal—when signal comes on, screen descends
.draperinc.com
Tab-Tension Adjustment Procedure for Ultimate Access/Series V
1 Determine which side requires adjustment. 2 Secure dowel with one hand.
Caution: Do not touch or bend surface.
3 Using Phillips-head screwdriver, depress springloaded adjustment screw (see drawing) and slowly turn clockwise to tighten tension, or counterclockwise to loosen tension. The screw adjusts in ¼ turn increments. Adjust only one increment (¼ turn). 4 If problem is not corrected, leave screen in position for 24 hours to allow surface material to stretch into position. 5 If problem still is not corrected, repeat steps 2 and 3.
(765) 987-799
Ultimate Access Series E & V by Draper Page 3 of 4
Single Station Control
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green (Ground)
Dashed wiring by electrician
Control switch
Single gang box by others Min. 4" x 2
1
/8" x 1 7/8" deep
Blue
Black
Red
Location of key operated on-off switch if furnished
To 110-120V Line
Multiple Station Control
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green (Ground)
Dashed wiring by electrician
Red
Red
Black
Blue
Blue
Cap off with wire nut and tape
Black
Red
Blue
Black
Single gang box by others Min. 4" x 2
1
/8" x 1 7/8" deep. 3 shown. More or less equally feasible.
Location of key operated on-off switch if furnished
www
9
White (Common)
110-120V
Internal Screen Wiring
w (Gnd)
Internal Screen Wiring
110-120V
8"
10"
Case Dimensions
Mounting brackets slide
9"
7½"
left and right as needed.
9
9
/16"
1"
5
/8"
L*
8"
Ceiling tile
(by others)
13
6
/16"
4¾"
9
9
/16"
5
/8"
Please Note: Do not wire motors in parallel.
Series E
Viewing Surface
Series E Series V
3
*L = 8
/16" Varies
Alternative mounting configuration
Standard Wiring Diagrams
Series V
Viewing Surface
Low Voltage and Remote Control
White-Common to screen & 110-120V AC Neutral Red-to screen (directional) Brown-to screen (directional) Yellow-to 110-120V AC -Hot Black-to 110-120V AC-Hot Green-Ground
Dashed wiring by electrician
Low voltage wiring by others
Eye Port for IR Eye, RF Receiver or LED Wall Switch. For more than one of these, a splitter is required.
3 Button Wall Switch DOWN - Black COM - White UP - Red
Aux Port for connecting additional LVC-III modules (up to six total can be linked­connect from Aux to Eye).
21/8"
STOP
STOP
Control Switches 24v DC
Red (Up) Black (Down) Green (Ground)
Line
Location of key operated on-off switch if furnished
To
.draperinc.com
Two-Way Serial Communication (RS232) with MC1
STOP
STOP
Control Switches 24v DC
Location of key operated on-off switch if furnished
(765) 987-799
White-Common to screen & 110-120V AC Neutral Red-to Screen (directional) Brown-to Screen (directional)
Program LED
Fuse
MC1
Black-Hot to 110-120V AC Green/Yellow-Ground
Low Voltage Wiring by others AC Wiring by electrician
RS232 Data FROM Control System RS232 Data TO Control System Signal Ground & Manual Switch Common Manual Switch Down Manual Switch Up
Eye Port for IR Eye. For RF Receiver or LED Wall Switch, a Splitter and a Power Supply is required. Plug RF Receiver or LED Wall Switch and Power Supply into splitter, then run cable from Splitter to MC1 Eye Port.
See separate Serial Communication-RS232 Instruction sheet for enabling RS232 with the MC1.
White (Common) Red (Up) Black (Down) Green/Yello
To
Line
Ultimate Access Series E & V by Draper Page 4 of 4
www
9
x
Green
Green
Wiring Diagrams with Built-In Controls
Built-In VIC-12*
12 Volt (VIC-12) or 6 Volt (VIC-6) Relay
Ring Terminal on ground wire riveted to J-Box with Star Washer
Brown (-)
Black Lead
13
14
:
:
::
9
:
:
::
5
:
:
::
1
Orange (+)
:
:
:
:
:
:
87
:
:
:
:
:
:
6
:
:
:
:
4
:
:
:
:
2
1
White Lead
Green/Yellow
5
3
Green/Yellow
Green
Red
Black
Black
White
115 Volt Relay
Green
Red
Black
Black
White
Green
Red
Black
HSG. Cap
HSG. Plug
White
Jacketed Motor Cable
Wire soldered to terminal
:
:
::
Wire connected with Quick Disconnect
Built-In VIC-115*
Ring Terminal on each Ground Wire with Star Washer screwed to Spine
Green
Red
Black
HSG. Cap
HSG. Plug
:
:
White
Jacketed Motor Cable
::
Wire connected with Quick Disconnect
Ground
#2 Up
#1 Down
Common
Ground
#2 Up
#1 Down
Common
110-120 VAC Screen Motor
110-120 VAC
Screen Motor
Field Wiring J-Box
Normally on Audience Left
#10 Ring Terminal on Ground
Wire Riveted to J-Box
White
White
Com
Orange
Black
Screen Down
Ye llow
Red
Red
Gray
Screen Up
Green
Green
Green
Ground
Door Close
Green
White
Black
Screen Motor Socket Door Motor Socket
Screen Motor Plug
Green
Ye llow
White
Door Motor Plug
Black
White
Com
Door Close
120V AC Door Motor120V AC Screen Motor
Orange
Brown
Red
Gray
Door Open
Screen Down
Green
Green
Ground
Built-In LVC-III
Strain Relief Bushing
Draper P/N C034.002 (HEYCO 6N3-4) 1 Per J-Box
White
Brown (Down)
Red (Up)
Black
Jacketed Cable
Draper P/N C115.001
(Green Wire not Used)
#10 Ring Terminal on Ground
Wire Riveted to J-Box
Crimp-on Wirenut by Draper Wirenut by others Wiring by others
LVC-III J-Box
Normally on Audience Right
White
Brown
Red
Black
120V AC LV C3 Module
Ye llow
Green
Stop
Down
Black
Red
White
LVC-S 24V DC
Wall Switch
Up
Red (Up)
White (Com)
Black (Down)
Yellow
Red
Orange
White
Screen Motor
Socket
Field Wiring J-Box
Audience Left
Location & Orientation
of Motor Sockets on J-Bo
Optional Radio
Receiver
or IR Sensor
Orange
Brown
Door Motor
Socket
Yellow
White
.draperinc.com
(765) 987-799