DRAPER Targa (16:10) 503/198"" 267*427 XT1000E LVC_IV_Wiring_Inst.pdf

Page 1
110-120V LVC-IV Low Voltage Control Module
Optional
(universal-either jack)
Antenna
To 110V AC-Hot
Input
AC Power
IR Eye
FUSE - 3.15 AMP 250 VAC 5x20mm
3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
To screen/lift. Seeindividual productwiring for details.
WIRING
INSTRUCTIONS
Technical Specifications:
Power Supply: 110V-120V / 60Hz
Temperature: -40° C – 85° C
Frequency: 433 MHz
Power: <300W
Transmit Power: <10mW
Sensitivity: -110dBm
Fuse: 3.15 Amp
WALL SWITCH
DRY CONTACT
WARNING
CLOSURE ONLY.
CONTROLLER.
APPLYING VOLTAGE
HERE WILL DAMAGE
RS232/485
or connection
to next LVC-IV
(supplied by others)
Low Voltage
Trigger 4-28 VDC
Please Note
-Don't let the RF receiver touch metal objects; this could affect the maximum distance the transmitter can be from the RF receiver.
-Disconnect the power supply before installing the RF receiver.
-Avoid electrostatic interference: Static electricity will damage the electronic components.
-Make sure there is more than 5 feet (1.52 meters) between the RF receiver and ground.
-Make sure there is more than 1 foot (30.5cm) between the RF receiver and ceiling.
-Make sure there is more than 1 foot (30.5cm) between the RF receiver and transmitter.
-If using more than one receiver, make sure they are separated by more than 8" (20cm).
RF Remote
Figure 1
your LVC-IV, call your dealer or contact Draper, Inc.
Draper, Inc. | 411 S. Pearl St. Spiceland, IN 47385
draperinc.com | 765.987.7999 | 800.238.7999
© 2017 All Rights Reserved | FORM: LVCIV_110_Wiring17
Page 2
110-120V LVC-IV Low Voltage Control Module
Receiv
White-Common to screen & 110 VAC Neutral
Red-to screen (directional)
Brown-to screen (directional)
Ye llow-to 110 VAC-Hot
Black-to 110 VAC-Hot
Green/Yellow (Ground)
White (Common)
Red (Up)
Black (Down)
Internal Screen Wiring
Green/Yellow
(Motor Ground)
Signal Light
Radio Frequency (RF) Remote Control
The LVC-IV comes with built-in Radio Frequency Remote control capability (optional handheld transmitter NOT included).
page 2 of 4
To "Learn" a remote
1. Press receiver button on LVC-IV (see Fig. 2A).
2. Signal light will flash slowly.
3. Press transmitter's Up button within 10 seconds (see Fig. 2B).
4. Signal light flashes three times quickly.
To "Un-Learn" a remote
1. Press receiver button on LVC-IV (see Fig. 2A).
2. Signal light will flash slowly.
3. Press transmitter's Down button within 10 seconds (see Fig. 2C).
4. Signal light flashes three times quickly.
Signal Light
Receiver
Button
Button
er
To "Un-Learn" all remotes
1. Press receiver button on LVC-IV until signal light flashes quickly, then release.
2. Press receiver button once while signal light is flashing.
3. Signal light will stop flashing.
Please Note: Operating range is 250ft (76 meters) open distance. RF Signal will degrade significantly with each wall it is required to penetrate. If you are experiencing issues with RF signal strength, the RF antenna can be threaded out one of the knockouts for better reception.
InfraRed (IR) Remote Control
1. Plug Optional IR Eye into mini plug input provided on LVC-IV (see Figs. 1 and 3).
CBA
Figure 2
2. IR Remote Control transmitter does not need to be "learned" by the LVC-IV. Simply point and operate.
3. Maximum IR Eye cable length is 42" (106 cm).
Please Note: IR Transmitter Range is 26ft. (7.9 metera).
DC Low Voltage Trigger
The LVC-IV comes with built-in connection for sending a DC trigger (4-28 VDC) from the projector to the projection screen.
1. Connect remote trigger voltage from projector to the low voltage trigger cable.
2. Plug the mini-jack plug of the low voltage trigger cable to the LVC-IV (Figure 1 & 4).
3. When projector is 'ON' the low voltage output of the projector will cause LVC-IV to deploy projection screen. When projector 'OFF' the low voltage is removed from LVC-IV and projection screen will retract into case.
Figure 3
Figure 4
Page 3
Receiver
Button
3 BUTTON WALL SWITCH
DOWN - BLACK
COM - WHITE
UP - RED
Wall Switch
To 110-120
VAC LINE
RED - to screen (directional)
BROWN - to screen (directional)
YELLOW - to 110V AC-Hot
BLACK - to 110V AC-Hot
WHITE - Common to screen & 110 AC Neutral
GREEN/YELLOW (Ground)
WHITE (Common)
BLACK (Up)
RED (Down)
INTERNAL SCREEN WIRING
GREEN/YELLOW
(Motor Ground)
Electrically Straight
Data Cable to more
LVC-IV modules*
N
L1
GND
Location of key
operated 0n-off
switch if furnished.
Signal Light
Dashed wiring by electrician
Low voltage wiring by others
*A maximum of six (6)
LVC-IV modules can be
linked together.
RS232/485 Inputs/Outputs
Low Voltage Trigger
4-28 VDC
IR Eye Input
RS232/485 Inputs/Outputs
Receiver
Button
Low Voltage Trigger
4-28 VDC
IR Eye Input
3 BUTTON WALL SWITCH
DOWN - BLACK
COM - WHITE
UP - RED
Wall Switch
To 110-120
VAC LINE
RED - to screen (directional)
BROWN - to screen (directional)
YELLOW - to 110V AC-Hot
BLACK - to 110V AC-Hot
WHITE - Common to screen & 110V AC Neutral
GREEN/YELLOW (Ground)
WHITE (Common)
RED (Up)
BLACK (Down)
GREEN/YELLOW
(Motor Ground)
Electrically Straight
Data Cable to more
LVC-IV modules*
N
L1
GND
Location of key
operated 0n-off
switch if furnished.
Signal Light
Receiver
Button
3 BUTTON WALL SWITCH
DOWN - BLACK
COM - WHITE
UP - RED
Wall Switch
To 110-120
VAC LINE
RED - to screen (directional)
BROWN - to screen (directional)
YELLOW - to 110V AC-Hot
BLACK - to 110V AC-Hot
WHITE - Common to screen & 110 AC Neutral
GREEN/YELLOW (Ground)
WHITE (Common)
BLACK (Up)
RED (Down)
INTERNAL SCREEN WIRING
GREEN/YELLOW
(Motor Ground)
Electrically Straight
Data Cable to more
LVC-IV modules*
N
L1
GND
Location of key
operated 0n-off
switch if furnished.
Signal Light
External LVC-IV - Single or Multiple
Ambassador and Rolleramic 120V Wiring Diagram
Dashed wiring by electrician
Low voltage wiring by others
Dashed wiring by electrician
Low voltage wiring by others
*A maximum of six (6)
LVC-IV modules can be
linked together.
*A maximum of six (6)
LVC-IV modules can be
linked together.
RS232/485 Inputs/Outputs
Low Voltage Trigger
4-28 VDC
IR Eye Input
110-120V LVC-IV Low Voltage Control Module
page 3 of 4
External LVC-IV—Single or Multiple
Projection Screen Wiring Diagram
External LVC-IV—Single or Multiple
Wiring Diagram for Ambassador and Rolleramic
Page 4
(5.62 cm)
Use the appropriate screws and hardware
t t
holes provided. largest size fastener
t
110-120V LVC-IV Low Voltage Control Module
RS232 / RS485 Information
RS232 / RS485 CommPort Parameters:
1. Frequency (BAUD Rate): 2400
2. Data long code : 8
3. Parity Check : N
4. Start bit : 1
5. Stop bit : 1
6. Flow Control : NONE
Connections using modular cable must be made using electrically straight 6-conductor modular cable (RJ25). This means colors do not cross over: blue leads to blue, green to green, etc. (see diagram at right)
Please Note:
page 4 of 4
1 2 3 4 5 6
COMMAND COMMAND STRINGS
UP 9A 01 01 00 0A DD D7
STOP 9A 01 01 00 0A CC C6
DOWN 9A 01 01 00 0A EE E4
For more detailed programming instructions or group control go to:
http://www.draperinc.com/DraperPro (registration required)
LVC-IV Dimensions
o mount the enclosure hrough the four key
Use
hat will fit in key holes.
REMARK
ID No. : 1 / Channel : 01
ID No. : 1 / Channel : 01
ID No. : 1 / Channel : 01
4.5"
(11.4 cm)
PIN 1 - 5VDC Output
PIN 2 - Down
PIN 3 - Up
PIN 4 - Ground
PIN 5 - RS485-A or RS232-GND
PIN 6 - RS485-B or RS232-Tx
2.214"
10.39"
(25.4 cm)
2.214"
(5.62 cm)
For AC supply wires attach appropriate ½" (13mm) Trade Size connector to route wiring through knockouts. For low voltage wires attach with appropriate connector to route wiring through knockouts. Knockouts are provided on all fours sides of the enclosure.