Scissor Lift Submittal & Planning
by
Sheet for SL and SLX Series
U.S. Patent D395,909
Planning sheet submission required with your order or request for quotation. Please mark appropriate response to each numbered
item (front and back)
➀ Select one model based on the maximum exact distance you need the projector to descend from “store”
position to “service” position.
Scissor Lift—SL Series
Quantity
4 ft.—Model SL4
5 ft.—Model SL5
6 ft.—Model SL6
7 ft.—Model SL7
8 ft.—Model SL8
9 ft.—Model SL9
10 ft.—Model SL10
➁ FOR SL SERIES ONLY: Standard, factory set “show” position
is 18" below “store” position. “Show” position can be adjusted
after installation. If more than 24" is required, list show
position:
Scissor Lift—SLX Series
Quantity
11 ft.—Model SLX11
12 ft.—Model SLX12
13 ft.—Model SLX13
14 ft.—Model SLX14
15 ft.—Model SLX15
16 ft.—Model SLX16
17 ft.—Model SLX17
➂ FOR SLX SERIES ONLY: Standard, factory set
“show” position is 36" below “store” position.
“Show” position can be adjusted after installation.
For “show” position of more or less than 36",
list show position.
Maximum
Lowering Retracted
Model Distance Height
SL4 4' 81/8"
SL5 5' 9
SL6 6' 10
SL7 7' 11
SL8 8' 12
SL9 9' 13
SL10 10' 14
1
/8"
1
/8"
1
/8"
1
/8"
1
/8"
1
/8"
Maximum
Lowering Retracted
Model Distance Height
SLX11 11' 13¾"
SLX12 12' 15¾"
SLX13 13' 15¾"
SLX14 14' 17
SLX15 15' 17
SLX16 16' 19
SLX17 17' 19
(shown slightly lowered)
Space for projector's
ceiling mounting bracket
Space for projector
Optional ceiling
closure panel
1
SMS Low Profi le Mount adds 47/8",
1
including universal bracket, to unit height.
23"
20¾"
See chart
(shown slightly
lowered)
Space for
projector's
1
/
8
"
1
/
8
"
1
/
8
"
1
/
8
"
ceiling
mounting
bracket
1
See chart
Space for projector
Optional ceiling
closure panel
2"
27"
24¾"
1
SMS Low Profi le Mount adds 47/8",
including universal bracket, to unit height.
2"
20¾"
Pair of
26¾"
Pair of
23½"
Fail-safe inertial
safety belt system
1
/8" aircraft cables
29½"
9/16" dia.
mounting holes
Fail-safe inertial
safety belt system
3
" aircraft cables
/16
9
/16" dia.
mounting holes
(Continued on Page 2)
DRAPER SALESPERSON:
CUSTOMER CONTACT:
SIGNATURE:
®
Copyright © 2008 Draper Inc. Form ScissorLift_Sub-PlanSheet08 Printed in U.S.A.
DEALER NAME:
PROJECT NAME:
P.O. #:
DATE:

Scissor Lift Submittal & Planning Sheet for SL and SLX Series page 2 of 4
➃ Select Optional Accessories
Optional Ceiling Access Door (2 x 2) to allow access above fi nished ceiling (highly recommended)
A) If you selected the SMS Low Profi le Mount please provide the following Projector information (supplied by others)
Manufacturer
B) If you selected the plenum housing option please provide the following information:
Projector Size H x W x L:
C) If you selected one of the above options please use the following chart to select the correct size plenum housing, ceiling closure, or ceiling fi nish kit:
Size B Size S Size E Size J Size G Size U
(SL Only) (SL Only)
Max. Projector Size W x L 25" x 25" 25½" x 27½" 25½" x 35½" 25½" x 39½" 31½" x 44½" 27½" x 30½"
Ceiling Opening W x L 29
Ceiling Closure Panel W x L 30
➄ Do you want the optional factory installed hookup for RGB, Video and Projector Control? Yes No
A What type of connectors do you need on Inputs (to Projector)? What type of connectors do you need on Outputs (to Lift)?
BNC How Many? BNC How Many?
15 Pin HD How Many? 15 Pin HD How Many?
RCA How Many? RCA How Many?
S-Video How Many? S-Video How Many?
RS232 (DB9) How Many? RS232 (DB9) How Many?
➅ Select Voltage:
110-120V
➆ Select Controls: This unit comes with one 12v Toggle Switch and 12v Momentary Key Control. For other switching
options, please select from below:
Optional Video Interface Control (VIC12) for projection screen operation
Specify number of switches (LVC-S)
*This is required for any of the following options:
➇ Will this unit be controlled by other equipment?
No.
White Painted Finish Accepts Ceiling Tile
Optional SMS Low Profi le Mount and Universal Bracket
Make/Model Projector Size H x W x L:
Optional plenum housing: optional ceiling closure panel not included.
Bracket height: Available space above ceiling:
Optional ceiling closure panel.
Optional ceiling fi nish kit: consists of ceiling closure panel and mating trim kit to fi nish ceiling opening.
7
/8" x 297/8" 29½" x 32" 29½" x 40" 29½" x 44" 357/8" x 49" 367/8" x 367/8" (Trim edge–to–edge)
5
/16" x 305/16" 30" x 32½" 30" x 405/8" 30" x 44½" 363/8" x 49½" 373/8" x 373/8" (Trim edge–to–edge)
220-230V
Optional Key Operated Power Supply Key Switch (On-off)
Optional Low Voltage Control (LVC-III)—24V*
(Controls the "Show" position only)
Wireless Remote Control (radio frequency transmitter & receiver) (Controls the "Show" position only)
Wireless Remote Control (infrared transmitter & receiver) (Controls the "Show" position only)
Yes. What kind of equipment?
Specifi cations—Scissor Lift
SLX12/SLX13/SLX14/SLX15/SLX16/SLX17), for projectors weighing up to 350#.
Dove grey baked powder coat fi nish. Projector bolts onto operating pan, or mounts
to pan with optional SMS Low Profi le Lift Bracket (projectors through 26 lbs only).
Electrically op er at ed 110-120V AC, 60 Hz. UL rec og nized gearmotor, with metal
chain drive system, to be lifetime lubricated.
For SL Models: Projector to be sus pend ed from 2¾" x 20" x 20" x 11 ga. steel
pan supported by steel scissor arms and operated by two
2000 foot/pounds tensile strength per cable.
For SLX Models: Projector to be sus pend ed from 3
pan supported by steel scissor arms and operated by two,
4200 foot/pounds tensile strength per cable.
Equipped with 3 sets of stabilizing scissors, positioned on the left, right, and
rear sides. Also equipped with fail-safe inertial safety belt system and Cable
Management System with projector power cord. Factory set limit switches to
automatically stop travel at store, show, and service positions. Single Station
Control, standard, consists of one 12V toggle switch to lower lift from “stored” to
“show ” positions, and one 12V momentary key switch to lower lift from “show” to
video projector lifts, Model (SL4/SL5/SL6/SL7/SL8/SL9/SL10/SLX11/
1
/8" aircraft cables with
1
/4" x 24" x 26" x 11 ga. steel
3
/16" aircraft cables with
www.draperinc.com
“service” position. Optional LVC-III for operation from “stored” to “show” positions
only; required for use with Key Operated Switch.
Optional plenum housing consists of suitable painted steel panels for use in return
air plenum situations. Optional ceiling closure panel, fi nished in white baked
textured powdercoat, shall descend smoothly with projector. Choose a model
based on number of feet needed (4'-9'/11'-17') to put projector within easy reach
for servicing.
Please Note: The Scissor Lift should be specifi ed in conjunction with a DRAPER
motorized screen.
SMS Low Profi le Fixed Mount: Ceiling mount shall consist of a steel ball joint and
Universal Projector Bracket. Mount shall be 2" long, and shall securely attach to
lift with steel mounting plate (provided). Installer shall provide mounting hardware
appropriate to ceiling conditions. Steel ball joint attaches to Universal Projector
Bracket with twist-lock engagement. Min. overall height of assembled unit shall
7
be 4
/8". Mount shall provide up to 30° roll or pitch adjustment and 360° yaw
adjustment at ball joint. Two setscrews lock ball joint in position. Max. load 26 lbs.
Optional Ceiling Access Door: Provides access to projector and lift when unit is
installed above hard ceiling. Choose one: [White painted fi nish/accepts ceiling tile].
Downloadable 3-part specifi cations are available at www.draperinc.com.
DRAPER SALESPERSON:
(765) 987-799
CUSTOMER CONTACT:
SIGNATURE:

Scissor Lift Submittal & Planning Sheet for SL and SLX Series page 3 of 4
Closure Panel Ceiling FInish Trim Kit
Threaded Rod
Closure Pan
Optional Acoustical
Tile by Others
Bottom Pan of
Scissor Lift
Angles with
Pre-drilled Holes
Installer to Drill Holes
Tee Moulding
(w/Mitred Corners)
Pop Rivets or Screws
Supplied by Others
Scissor Lift Plenum Housing (Exploded View)
Threaded Rod
Trim Frame
Closure Pan
Installer to Drill Holes
Optional Acoustical
Tile by Others
Bottom Pan of
Scissor Lift
Angles with
Pre-drilled Holes
Tee Moulding
(w/Mitred Corners)
Pop Rivets or Screws
Supplied by Others
DRAPER SALESPERSON:
CUSTOMER CONTACT:
www.draperinc.com
(765) 987-799
SIGNATURE:

Scissor Lift Submittal & Planning Sheet for SL and SLX Series page 4 of 4
Wiring Diagram
Motor
GN
BK
Dashed wiring by
electrician
WH
Capacitor
Momentary
Key
Up
WH
BK
(Red)
Switch
Down
Terminal Strip
(Brown)
24V Switching
Toggle
BK
BE
RD
GN
BK
RD
BK
RD
RD
GN
BK
6 Conductor Modular Cable
(75' supplied)
Switch
Up
Dn
YW
GN
BE
Wall Switch
Common
RD not used
(Yellow)
110v AC Supply
L1
GRD
N
BK
Transformer
WH
BE
BN
WH
GN
RD
BK
Key
12V
RD
GN
BK
WH
BE
BN
RD
BE
BE
RD
10A
3A
78910
6
5
BK
BEWH
BK
BK
YW
YW
1234
3 x 3
YW
Down Relay
Connection
Board
1A
BE
BK
NC
NO
COM
BE
BE
BK
78910
6
BK
BK
RD
12345
BK
RD
BKBKBK
BERDBE
RD
RD
YW
BK
BK
(-) (+)
BEBE
BEBE
Up
Limit
Key
Switch
(DPDT)
Down
Key
Limit switch
Down
Show position
RD
RD
NC
Up Relay
BE
RD
NO
COM
(-) (+)
RD
Limit switch
Down
Service position
Limit switch
DRAPER SALESPERSON:
CUSTOMER CONTACT:
www.draperinc.com
(765) 987-799
SIGNATURE: