Draper IntelliFlex Installation Instructions Manual

Page 1
Installation Instructions
® 24 Channel IR and RF Remote Control by Draper
Each 24 channel IR and RF transmitter works with every channel you can have within the IntelliFlex family of motor controls. By “Selecting” a layout, you will be confi guring a transmitter to output a selected range of channels. To begin the process of “Selecting” which Transmitter layout, you fi rst need to understand the button numbering system. This numbering system simply assigns a number to specifi c buttons, allowing us to press specifi c buttons in the necessary order to “Select” a layout.
OPEN CLOSE
13
17
21
25
1
1
5
2
9
3
4
5
6
7
OPEN CLOSE
1
23
ALL
7
6
8
9
11
10
10
14
15
18
19
11
22
12
23
26
27
4
8
12
16
20
24
STOP
28
Pre-confi gured layouts (blank cells in the following tables mean button is not used.
Layout 1 (T24 with shift: 1 thru 24)
O1 C1 OAll CAll
O2 C2 O8 C8
O3 C3 O9 C9
O4 C4 O10 C10
O5 C5 O11 C11
O6 C6 O12 C12
O7 C7 Shft> Stop
O13 C13 OAll CAll
O14 C14 O20 C20
O15 C15 O21 C21
O16 C16 O22 C22
O17 C17 O23 C23
O18 C18 O24 C24
O19 C19 <Shft Stop
Layout 2 (T24 with shift: 13 thru 36)
O13 C13 OAll CAll
O14 C14 O20 C20
O15 C15 O21 C21
O16 C16 O22 C22
O17 C17 O23 C23
O18 C18 O24 C24
O19 C19 Shft> Stop
O25 C25 OAll CAll
O26 C26 O32 C32
O27 C27 O33 C33
O28 C28 O34 C34
O29 C29 O35 C35
O30 C30 O36 C36
O31 C31 <Shft Stop
Layout 3 (T24 with shift: 25 thru 48)
To select a layout for 24-channel transmitter layout, follow these steps:
Button Press LED NOTE
Press and HOLD ON Solid both buttons 6 & 7 Continue holding buttons OFF LED will not fl ash until BOTH 6 & 7 until LED goes OFF buttons are released in step 3 Release both Flashing You have 4 seconds buttons 6 & 7 rapidly to complete step 4 Press and release Flashes the layout Complete the “Layout” button you have just selected you wish the Keypad to become (see charts for selectable layouts)
To change the “Radio” address of a 24-channel transmitter, follow these steps:
Button Press LED NOTE
Press and HOLD both ON Solid buttons 6 & 7 Continue holding buttons OFF LED will not fl ash until BOTH 6 & 7 until LED goes OFF buttons are released in step 3 Release both Flashing You have 4 seconds buttons 6 & 7 rapidly to complete step 4 Press and release LED does one quick Complete button 6 fl ash and goes off
O25 C25 OAll CAll
O26 C26 O32 C32
O27 C27 O33 C33
O28 C28 O34 C34
O29 C29 O35 C35
O30 C30 O36 C36
O31 C31 Shft> Stop
Layout 4 (T24 with shift: 37 thru 60)
O37 C37 OAll CAll
O38 C38 O44 C44
O39 C39 O45 C45
O40 C40 O46 C46
O41 C41 O47 C47
O42 C42 O48 C48
O43 C43 <Shft Stop
O37 C37 OAll CAll
O38 C38 O44 C44
O39 C39 O45 C45
O40 C40 O46 C46
O41 C41 O47 C47
O42 C42 O48 C48
O43 C43 <Shft Stop
O49 C49 OAll CAll
O50 C50 O56 C56
O51 C51 O57 C57
O52 C52 O58 C58
O53 C53 O59 C59
O54 C54 O60 C60
O55 C55 <Shft Stop
®
Copyright ©2008 Draper Inc. Form IntelliFlex_IR_RF_Remote_Inst08 Printed in U.S.A.
If you encounter any diffi culties programming your IntelliFlex IR or RF control, call your dealer or Draper, Inc., Spiceland, Ind., (765) 987-7999 or fax (765) 987-7142.
Page 2
IntelliFlex™ IR Remote Control by Draper Page 2 of 2
9
** If you select any undefi ned layouts, the result is a standard T12 without shift. Front LED Blinks Indicate Selected Layout: The Red LED on the front of the transmitter, in the upper left corner, will blink to tell you which layout is selected when either of the following occurs:
-Batteries are removed and reinserted at the completion of the button 6+7 sequence to select a layout, or
-The blinks are long and short. Each long blink indicates 5's and each short blink indicates 1's, with the sum indicating the currently selected layout. If the LED does not blink when batteries are inserted, press and hold any button, then remove the batteries. Then release all the buttons and reinsert the batteries watching for the blinks.
IR Codes
IR wavelength is 950 nm. Light is modulated at 38 KHz with 1/3 duty cycle. An on pulse must be at least 158 µseconds (µs) long (6 cycles) and should not be longer than 448 µs (17 cycles). From the start of a pulse till the start of the next pulse is 1050 µs for a “0 bit”, and 2000 µs for a “1 bit”. A Flash is 11 pulses (10 bits), minimum time between fl ashes (interfl ash time) is 11 mseconds (ms). When using the small eye the minimum interfl ash time is 25 ms, 30 ms is recommended. There is NO preamble. Channel 1 OPEN sequence is 0101000010. The sequence always starts with 01, so for simplicity strip that off, and we get 0100 0010 = hex 42 (see fi gure below). Please Note: low = off, high =38 KHz signal on.
Flash Interflash Time (30 ms)
The complete table of codes (in hex) is:
OPEN142 OPEN13 40
CLOSE1 22 CLOSE13 20
OPEN2 62 OPEN14 60
CLOSE2 12 CLOSE14 10
OPEN3 32 OPEN15 30
CLOSE3 0a CLOSE15 08
OPEN4 4a OPEN16 48
CLOSE4 2a CLOSE16 28
OPEN5 1a OPEN17 18
CLOSE5 06 CLOSE17 04
OPEN6 46 OPEN18 44
CLOSE6 26 CLOSE18 24
OPEN7 16 OPEN19 14
CLOSE7 0e CLOSE19 0c
OPEN8 56 OPEN20 54
CLOSE8 36 CLOSE20 34
OPEN9 4e OPEN21 4c CLOSE9 2e CLOSE21 2c OPEN10 5a OPEN22 58
CLOSE10 3a CLOSE22 38
OPEN11 02 OPEN23 1c
CLOSE11 72 CLOSE23 70
OPEN12 6a OPEN24 68
CLOSE12 66 CLOSE24 64
OPEN ALL (1-12) 76 OPEN ALL (13-24) 74
CLOSE ALL (1-12) 6e CLOSE ALL (13-24) 6c
STOP 52
IR Eye Only
0
1050 µs
00 0
0
1
1
0
0
1
2000 µs
A Note on Wiring
time
2000 µs
The IR Receiver Eye must be plugged in to an open "Eye" jack (see diagram on page 1). All input devices connect using electrically straight 4-conductor modular cable.
Please note: If you use standard telephone cable, you must fi rst remove one connector, turn it over and re-attach, to ensure that the cable is electrically straight (see diagram below).
www.draperinc.com
(765) 987-799
Loading...