Draper Envoy Installation & Operating Instructions Manual

Installation/Operating Instructions
Caution
Read instructions through completely before proceeding.Follow instructions carefully. Installation contrary to instructions
invalidates warranty.
Entire bottom of screen case should be unobstructed to per mit proper
operation of automatic trap door, and access to bottom panel for making electrical connections or servicing.
Screen should be installed level (using a carpenter’s level).Nothing should be fastened to screen dowel, viewing surface or
automatic trap door.
Operating switch(es) packed separately in screen carton. Do not discard
with packing material.
Screen operates on 115 v., 60 hz. current.
NOTE: Screen has been thoroughly inspected and tested at factory and found to be operating properly prior to shipment.
Hanging Screen
General:
When locating viewing surface and checking clearance for screen’s operation, remember surface is centered in case. Screen is normally recessed above ceiling and may be installed in a variety of ways. See typical installation detailed on back of this sheet. Regardless of mounting method used, the following points apply: Screen should be positively and securely supported so that vibration or
even abusive pulling on viewing surface will not weaken installation.
Installer must insure that fasteners used are of adequate strength and
suitable for the mounting surface chosen.
Entire bottom of case must be readily accessible after installation is
complete.
Hinge on bottom board and particularly hinge on automatic trap door of
screen must be permitted to operate freely. Front and back of case must be straight—not forced to warp or bow. Hinges must be free from mastic or paint buildup, and doors must be unobstructed by ceiling tiles.
Do not use screen case to support adjacent sections of ceiling. If trim pieces must be attached to case, do not permit screws to protrude
through ¾" wall of case. Do not attach trim with nails.
If case is painted, slots around doors should be shielded to protect viewing
surface from paint splatters or overspray.
Do not seal unit in ceiling unit electrical connections have been made and
screen has been operated successfully.
Electrical Connections
Screen operates on 115 v., 60 hz. current. Junction box is located just above bottom board near left end of screen. Bottom board is held closed with flathead screws and may be opened with a Phillips screwdriver. (Automatic trap door is held shut by viewing surface and must not be forced open.) Removal of junction box cover plate exposes red, black and white pigtail leads and green internal ground wire per wiring diagram attached. Screen is shipped with internal wiring complete and control switch(es) fully boxed. Wire connecting screen to switch(es) and switch(es) to power supply should be furnished by installer. Connections should be made in accordance with attached wiring diagram, and wiring should comply with National and local electrical codes.
All operating switches should be “off” before power is connected.
When screen is first operated, be cautious! If automatic trap door does not drop open immediately when switch is flipped “down”, return switch to “off” and free trap door and/or recheck electrical connections before proceeding. Cycle unit down and up several times to confirm satisfactory operation.
115V Single Station Control —
operation to be stopped at any point. Factory adjusted limit switches automatically stop screen when fully down or fully up.
115V Multiple Station Control
115V Single Station Control. Screen stops when switch is released and may be restarted in either direction. Factory adjusted limit switches stop screen automatically when fully up or fully down.
24V Control —
desired, operate in any sequence. Factory adjusted limit switches automatically stop screen when fully up or fully down.
Key Operated Switching —
optionally available with this unit. The key-operated power supply switch controls power to the screen and switches. When it is “off”, the switches will not operate screen. Key may be removed from the switch in either “on” or “off” position. A three-position key switch permits the screen to be operated directly by key. In this case, the screens operator must always have a key.
Screen has been factory set and should not normally require further adjustment. However, if you desire to change the “up” and “down” stopping positions, proceed as follows: CAUTION: Be sure all switches are in “off position before adjusting limit switches. Always be prepared to shut screen off manually when new adjustment is being tested. Screen may be severely damaged if viewing surface is allowed to run too far up or too far down.
Adjusting “fully up” position —
above left end of automatic trap door, is tripped as door closes. If door does not close fully, limit switch should be raised slightly. If door closes too tightly, switch should be lowered slightly. Remove steel plate attached to threaded neck of “up” limit switch by removing hex nut securing it. Removing plate exposes three Phillips head machine screws which hold limit switch bracket in place. Turning these screws clockwise will raise limit switch; turning them counterclockwise will lower it. Raise switch only in quarter-turn increments. When operating properly automatic trap door should close gently and rest against but not press on rubber bumpers above it. Adjusting automatic door so that it closes too tightly will damage screen.
Adjusting “fully down” position —
adjusted by turning the white limit switch adjustment socket. The white socket is located on the left end of screen roller and is accessible to a screwdriver/ Allen wrench (4mm or 5/32") when automatic trap door is open. Access is easier when bottom board is also open. (Do not adjust the yellow socket which is next to and in back of the white socket). Turning the white socket counterclockwise will allow viewing surface to run farther down. Turning it clockwise will shorten the viewing surface, stopping it in a less extended position. At no time should viewing surface be unrolled enough to expose any part of screen roller.
Operation
3-position up-off-down switch permits
Switches are similar in appearance to
Three-button up-stop-down switches stop at any point
Two kinds of key-operated switches are
Adjustments
Up limit switch, located immediately
Down stopping position may be
If you encounter any difficulties installing or servicing your Envoy screen, call your dealer or Draper, Inc., Spiceland, Indiana, (765) 987-7999, fax (765) 987-7142, or e-mail draper@draperinc.com.
411 S. Pearl St., Spiceland, IN 47385 USA
e-mail draper@draperinc.com ❚ www.draperinc.com
Copyright © 2000 Draper, Inc. Form Envoyi00R Printed in U.S.A.
765-987-7999
fax 765-987-7142
Env o y b y Draper
7 13/16"
9
7
/16"
/16"
1
4
/16"
1
/8"
9
7
Incl. mtg. brackets
Support rods by others
Surrounding ceiling
Mounting brackets
Case Dimensions/Method of Installation
Viewing
surface
Fabric Width + 15"
2"
13
7
/16"
2"
1
1
/4"
7
1
/8"
5
/8"
1
2
/4"
1
1
/4"
1¾"
9
7
/16"
Conduit connection 2" up on this end
1"
1
/4"
1
7½"
Page 2 of 2
2"
Standard
Construction
Offset
Construction
Single Station Control
Junction box at left end of screen
To 115V Line
Dashed wiring by installer
Control switch
Blue Red
Location of key operated on-off switch if furnished
Wiring Diagrams
Internal Screen Wiring White (Common) Black (Down) Red (Up) Green (Ground)
Single gang box by others Min. 4" x 2 1/8" x 1 7/8" deep
Black
Motor
Multiple Station Control
Junction box at left end of screen
Internal Screen Wiring White (Common) Black (Down) Red (Up) Green (Ground)
Cap off with wire nut and tape
Red
Red
Red
Location of key operated on-off switch if furnished
Black
Black
Black
Blue
Dashed wiring by installer
Blue
Blue
Single gang box by others Min. 4" x 2 1/8" x 1 7/8" deep. 3 shown. More or less equally feasible.
Motor
Control Switches 24 VDC
STOP
STOP
To 115V Line
Low Voltage (& Wireless) Control Wiring Diagram
Black (DN)
Black (DN) Red (UP)
Red (UP) White (COM)
White (COM)
Black (DN) Red (UP) White (COM)
Low Voltage Control Module
Black
White
Red White
Optional Radio Receiver Package
Red
Brown
Black Yellow Green
Optional Infrared Receiver Package
115 VAC Supply
Dotted wiring by installer
Internal Screen Wiring
White (Common) Red (Up) Black (Down) Green (Ground)