Installation/Operating Instructions
3
Top View
Side View
AeroLift 35 by Draper
1 Read instructions completely before proceeding.
Caution:
2 Follow instructions carefully. Installation contrary to instructions invalidates warranty. 3 Do not obstruct operation of AeroLift 35 with fingers or any object. Serious injury or damage could result. 4 It is not uncommon to overheat the motor during initial installation when set­ ting limits. The motor is thermally protected and will stop working temporarily. DO NOT physically pull the unit down when this occurs. Once it has cooled to a safe temperature, it will begin operating again. 5 The AeroLift 35 is designed to accommodate ceiling suspended equipment. Equipment should not be allowed to rest on ceiling closure during operation. (Refer to section titled “Installing Projector.”)
6 Entire bottom of unit must be unobstructed to permit proper operation. 7 Unit must be installed level (use a carpenter’s level). 8 Unit operates on 110-120V AC 60 Hz. current.
Note: Unit has been thoroughly inspected and tested at factory and found to be operating properly prior to shipment.
Planning
1 Based on screen location and projector specifications, determine proper
Unit operates on 110-120V AC, 60 Hz. current. The AeroLift 35 is shipped closed, with a temporary field connection provided in the form of a pigtail temporarily wired to the unit. After hanging the unit, make sure power is off and use this pigtail to temporarily connect the unit to power and to a switch, so the unit can be lowered to allow access inside. AeroLift must be installed in accordance with the requirements of the Local Building Codes, the Canadian Electrical Code (CEC), CAN/CSA C22.1 and the National Electric Code(NEC), NFPA 70. All operating switches should be “off” before power is connected.
Please note: Make sure electrical supply has been disconnected before attempting to connect AeroLift 35 to electricity.
Terminal strip for field connections is located inside a junction box on the end of the unit. Unit is shipped with internal wiring complete to the terminal strip. Once the unit has been lowered, turn off power and remove the J-box cover. The terminal strip is attached to the cover. Disconnect temporary pigtail from unit, then complete permanent wiring to electricity and to switches. Wire to connect unit to power supply and to switches should be furnished by installer. Connections should be made in accordance with wiring diagram. AeroLift 35 should be operated and checked prior to installing projector and/or optional ceiling closure.
position for projector installation. 2 Confirm that there is adequate space for installation and operation. Minimum clearance above ceiling level varies according to height of projector, optional projector mounting bracket, optional ceiling closure and optional Environmental Housing.
3 Arrange to provide service access to the unit. 4 When installed with Environmental Air Space Housing unit is suitable for
use in an environmental air space in accordance with in accordance with Section 300.22(C) of the National Electrical Code, and Section 2-128, 12-
010(3) and 12-100 of the Canadian Electrical Code, Part 1, CSA C22.1.
5 Total capacity of lift is 35 lbs, including closure, projector and bracket.
As Soon As AeroLift 35 Arrives
1 Open carton and inspect for damage. 2 Locate the following parts:
A. The unit itself B. Controls C. Any optional equipment
Hanging Unit
The AeroLift 35 is provided with four (4) mounting angles for suspending or direct mounting the unit from above or direct mounting from the sides. These angles provide up to 1½" of adjustment (front to back). The AeroLift 35 is designed to fit between joists spaced 16" apart on center (assuming 2" joists), and to close to aproximately 4", not including the projector, bracket or closure. The unit should be guy wired or blocked to prevent swinging. All installations should observe the following guidelines: 1 Installer must ensure that all fasteners and supports are of adequate strength to securely support AeroLift 35 and projector. It is recommended that hardware structure be able to hold at least four times the combined weight of the lift, projector, housing, closure and ceiling material attached to closure.
Caution: DO NOT hang from, "ride" or pull down on the unit. This could create a failure and cause damage and/or injury.
2 Fastening methods must be suitable for mounting surface, and securely anchored so that vibration or abusive pulling on unit will not weaken installation. 3 Bottom of unit must be unobstructed after installation. Sufficient clearance must be allowed below projector or optional ceiling closure. 4 Do not use unit to support adjacent ceiling, light fixtures, etc.
When unit is first operated, be cautious! If unit fails to operate when the switch is flipped “down”, return switch to “off” and recheck electrical connections before proceeding. Cycle unit down and up several times to confirm satisfactory operation.
110-120V Single Station Control — 3-position up-off-down switch permits operation to be stopped at any point. Factory adjusted limit switches automatically stop AeroLift 35 when fully down or fully up.
Optional 110-120V Multiple Station Control— Switches are similar in appearance to 110-120V Single Station Control. AeroLift 35 stops when switch is released and may be restarted in either direction. Factory adjusted limit switches automatically stop AeroLift 35 when up or fully down.
Optional 24V Control — Three-button up-stop-down switches stop at any point desired, operate in any sequence. Factory adjusted limit switches automatically stop AeroLift 35 when fully up or fully down.
Optional Infrared or Radio Frequency Remote Control—
If ordered, a three-button transmitter is provided, with “up”, “down”, and “stop” buttons. Unit starts up or down when appropriate button is pressed, and may be stopped by pressing “off” button. Factory set limit switches stop unit automatically when projector is in “show” position.
Optional RS232/Ethernet—
Serial communication and network communication optionally available with wall switches, RF or IR remote.
Optional Key Operated Switching —
Two kinds of key-operated switches are optionally available with this unit. 1 The key-operated power supply switch controls power to the AeroLift 35 and switches. When it is “off”, the switches will not operate lift. Key may be removed from the switch in either “on” or “off” position. 2 A three-position key switch permits the AeroLift 35 to be operated directly by key. In this case, the screen’s operator must always have a key.
5 Do not complete the ceiling below unit until electrical connections have been completed and unit has been operated successfully. 6 Use slots on the projector plate and on the closure to adjust the unit to ensure proper alignment of ceiling closure relative to ceiling opening.
AeroLift 35 Mounting Hole Dimensions
221/4"
19
3
/8"
7
/8"
18
1
1
/4"
/4"
121/2"
101/8"
to
to
14"
115/8"
The AeroLift 35 is equipped with a Safety Limit Switch (see "AeroLift 35—Limit Switch Adjustment (Bottom View)" diagram on page 3). This switch may be dam­aged during shipping or by rough handling on the job site. Once the AeroLift 35 has been installed in the ceiling, but before the projector and closure are attached, the Safety Limit must be tested. Use a screw­driver or other tool to press and hold the switch. While holding down the switch, have someone operate the unit. If the unit works
while the switch is depressed, the limit switch is broken and must be replaced.
Operating the unit without a functioning Safety Limit Switch could cause the unit's motor to continue operating after the lift is closed, leading to a failure and the possibility of damage or injury.
Please Note: As weight is applied to the AeroLift 35, the projector plate may shift slightly. If this occurs, use setscrews on bottom of fabric roller brackets to compensate for shift and level projector plate.
Copyright © 2016 Draper Inc. Form AeroLift35_
Inst16
Printed in U.S.A.
If you encounter any difficulties installing or servicing your AeroLift 35, call your dealer or Draper, Inc. in Spiceland, Indiana, 765-987-7999, or fax 765-987-7142.
Electrical Connections
Operation
Testing the Safety Limit Switches
Page 2
AeroLift 35 by Draper, Inc. page 2 of 4
www
7"
(178mm)
10" (254mm)
5½"
(140mm)
Large Environmental Air Space Housing, Lift, and Closure Dimensions
Top View
Ceiling Trim Ring 23 7/8"
EASH Mounting Holes 20 5/8"
Lift Mounting Holes
19 3/8"
"
"
Ø 3/8" 8x
Closure
10
12
to
20
Trim
Ring
Panel
Closure
1
/8"
Panel
25"
Ceiling Trim Ring 23 7/8"
EASH 23 ½"
5
8
/
"
5
8
/
"
Center of Rod
Between Rod
Closure Panel 25"
EASH
21"
11
20
22
16
/
"
5
8
/
"
/8"
5
/8"
7
Ceiling Trim Ring 23
EASH Mounting Holes 20
Closure Panel 25"
Lipless Closure Dims: 22 1/8" x 22 1/8"
Side ViewFront/Back View
Ceiling Trim Ring 23 7/8"
EASH 23 ½"
EASH
Center of Rod
21"
Between Rod
11
16
20
/
5
8
22
/
Closure Panel 25"
Small Environmental Air Space Housing, Lift, and Closure Dimensions
Top View
Ceiling Trim Ring 23 7/8"
EASH Mounting Holes 21¼"
"
16
/
9
Holes 8¾"
EASH Mounting
Ceiling Trim Ring 14
Lift Mounting Holes
Ø 7/16" 4x
19 3/8"
10 1/8”
Closure
Panel
15 5/8"
Closure Panel 25"
Lipless Closure Dims: 22 1/8" x 12 1/8"
Front/Back ViewSide View
Ceiling Trim Ring
Ceiling Trim Ring 23 7/8"
EASH 23 ½"
EASH
Center of Rod
21"
Between Rod
11
16
20
/
"
5
8
22
/
"
Closure Panel 25"
5
12
/
to
5
/
20
Trim Ring
Closure
Panel
14 9/16"
EASH 14 ¼"
8
"
EASH
8
"
Center
of Rod
Between
13 3/16"
Closure Panel
101/8”
Rod
9
9
/16”
15 5/8"
Installing Optional Environmental Air Space Housing
The Environmental Air Space Housing is shipped pre-assembled in its short­est position. The height of the housing can be adjusted by moving the screws to different mounting holes in side panels. The incremental adjustment for the top screw and bottom screw is ½"; the incremental adjustment for the rest of the screws is 1". You can install the housing in a pre-assembled state or as separate components, which will require that the housing be completely disassembled prior to installation. Please note that if the Environmental Air Space Housing is to be installed in a space where there is no access from above the housing, then it is recom­mended that the AeroLift 35 be installed to the upper section prior to installing the housing. It is also recommended that an access panel be installed to allow future access.
1 Install top section of housing using outer four holes located on top of upper section. If installing large housing, make sure it is oriented properly to allow correct placement of lift within housing. 2 If installing the large closure, attach brackets to bottom of projector plate (see drawing on page 3). 3 Attach AeroLift 35 to upper section of housing through the inner four holes in the upper section with the 5/16" –18 x 7/8" hex head screws, 5/16" flat washers and lock nuts provided with housing. The lock nuts should be used above the housing (one per screw). 4 Attach the two flat panels of the middle section across from each other with the clinch nuts to the outside of the housing. 5 Attach the two middle section panels with the formed ends across from one another. 6 Attach lower section of Environmental Air Space Housing.
Environmental Air Space
Housing (collapsed)
A - Upper Section
B - Middle Section
(Inside View)
C - Lower Section
(Ceiling Trim Kit)
.draperinc.com (765) 987-7999
Installing Projector
Draper’s optional Universal Projector Mount will hold up to 26 lbs.
See Installation Instructions included with Universal Pojector Mount.
If not using Draper’s Universal Projector Mount, generally the video projector should be suspended from the bottom pan according to projector manufacturer’s instructions.
If installing with a small closure, maximum projector size is 18" x 8¾" (width x length x Environmental Air Space Housing height).
If installing with a large closure, maximum projector size is 18" x 18" (width x length x Housing height).
The projector plate is not pre-drilled. When drilling inital holes for mounting projector, or if for any reason the hole placement must be changed, completely lower AeroLift 35 before attempting to drill holes. When attaching projector bracket to plate, make sure screws are short enough that they do not touch the motor/roller above the plate when lift is closed.
Unit and projection system should be operated, checked and adjusted as necessary at this time (see below for limit adjustment procedures).
Warning: Keep fingers & other objects away from ceiling closure when unit is operating. Serious injury or damage can result.
2½"
(64mm)
(140mm)
12" (305mm)
5½"
10" (254mm)
12" (305mm)
7"
(178mm)
Page 3
AeroLift 35 by Draper, Inc. page 3 of 4
www
Up (closed)
/8" Min. clearance
Lower section of
If your AeroLift 35 is equipped with a ceiling closure system, it can be used as is, or in conjunction with a piece of existing ceiling tile.
Please refer to diagrams at right for these instructions.
1 If installing with ceiling tile, you may need to cut tile so overall dimensions are the same as (or slightly less than) the closure panel. Place tile into trim frame. Lay closure panel on top (back side) of ceiling tile, and tighten screws to hold in place.
2 If installing large closure, attach brackets to bottom of projector plate (see fig. 7). 3 Attach 5/16" threaded rods to slots in projector plate or brackets.
Caution: Make sure bolts and nuts attaching brackets to AeroLift are
completely tightened.
4 Run unit “up” until bottom pan stops at highest position. Mark position on 5/16" rods even with ceiling level and cut rods to length (removing from pan if convenient).
5 Run unit “down” until bottom pan stops at “show” position. 6 Attach closure to lower end of 5/16" rods by slipping into four corner slots and secure
with nuts above and below slots. 7 Run unit “up” again to highest position. Measure distance by which panel fails to reach required “closed” height for surrounding ceiling.
Caution: Make sure nuts are completely tightened.
8 Run unit “down” then re-adjust mounting of 5/16" rods in traveling grid to raise panel required distance. 9 Test unit operation to confirm that panel will stop in closed position just before touching ceiling.
PLEASE NOTE: Immediately upon completion of the surrounding ceiling, unit should be operated to confirm that optional ceiling closure panel by Draper or by others stops 1/8" short of touching ceiling in closed position. If closure panel touches, the motor may continue operating after the lift is closed. If it continues to cycle once the lift is closed, a failure may occur, making the unit descend rapidly and causing damage and/or injury.
Caution: DO NOT hang from, "ride" or pull down on the unit. This
could create a failure and cause damage and/or injury.
Adjustments
CAUTION: Be sure all switches are in “off ” position before adjusting limit switches
Always be prepared to shut lift off manually when new adjustment is being tested.
Limit switches for the AeroLift 35 are preset at the factory. The “Up” (closed) limit switch is set for fully closed. The “down” (show) limit switch is set for fully lowered. Once unit is in place, the “down” limit switch may need to be changed to stop the AeroLift 35 closer to the ceiling (that is, to raise the “down” position). Limit switches are located on the end of roller, and are accessible by removing the cover of the junction box at the left end of the unit. To adjust the limit switches, use a 5/32" screwdriver/allen wrench.
Caution: It is not uncommon to overheat the motor during initial installation when setting limits. The motor is thermally protected and will stop working until it has cooled to a safe temperature before it will start operating again. DO NOT physically pull the unit down when this occurs.
Installing Ceiling Closure
Down (open) Limit Switch
Limit Switch
AeroLift 35
Standard Closure
For Additional Safety:
1 Be sure the nuts that attach the threaded rods to the closure are tight. 2 Wrap a plastic wire tie around the mounting tab and the threaded
rod at all four corners of the closure panel (see drawing). Please Note: Do NOT use a paper-covered or similar wire
tie—use only plastic wire ties for maximum safety.
AeroLift 35 with
Large Closure and Brackets
Large Closure
Brackets
AeroLift Clearance
Caution: Make sure there are
no obstructions
to the AeroLift's
operation
Fabric Roller Adjustment Setscrews (one on each roller end)
Adjusting “Down” (show) position — “Down” position may be adjusted by turning the #1 limit switch adjustment socket. Turning the socket clockwise will stop the AeroLift 35 closer to the ceiling. Turning it counter­clockwise will cause the lift to stop at a lower point.
Adjusting “Up” (closed) position — Because the “up” (“closed”) position is preset at the factory, Draper does not recommend changing this position using the limit switch. The “up” position of the closure may be changed by changing the length of threaded rod (see fig. 6). If necessary, however, “up” position may be adjusted by turning the #2 limit switch adjustment socket. Turning the socket counterclockwise creates a higher, or more fully closed position. Turning it clockwise creates a lower ‘UP” (closed) position.
Caution: Make sure limit switch is set so that the AeroLift 35 motor is NOT still running after the lift is closed. If it continues to cycle once the lift is closed, a failure may occur, making the unit descend rapidly and causing damage and/or injury.
Please Note: If load is off-center of pan, you may need to adjust the pitch of the
fabric rollers. One setscrew is provided on each end of both fabric rollers (see above drawing). Use these to adjust roller pitch to keep entire fabric panel taut, so load is evenly distributed. Use 1/8" hex key to adjust.
.draperinc.com (765) 987-7999
1
Installing Optional Ceiling Trim Kit
The AeroLift 35 is available with a ceiling trim kit, which consists of the lower section of the Environmental Air Space housing and optional closure panel.
1 Install AeroLift 35 as previously described in these instructions.
2 Install bottom section of housing in opening. This can be accomplished by suspending with wire, or by mounting directly to the ceiling joists (if space permits).
3 Install projector and attach optional ceiling closure to AeroLift 35 (see instructions on page 3).
Ceiling tile
(by others)
Environmental Air
Space Housing
Trim Ring
Page 4
AeroLift 35 by Draper, Inc. page 4 of 4
To 110-120V Line
Dashed wiring
Single gang box by others Min. 4" x
Single gang box by others Min. 4" x
Dashed Wiring
To 110 -120 Vac Line
www
AeroLift 35 Inspection and Maintenance
Draper recommends inspecting the AeroLift at least annually or every 300 cycles—whichever comes first. A recommended maintenance schedule includes:
-Fabric: Inspect for fraying and proper tracking on the roller.
-Limit Switches: Make sure they are not damaged and are set properly.
-Wire Ties: Inspect wire ties attaching cables to the stabilizer arm.
-Closure: Make sure threaded rod remains seated firmly in the closure panel corners, and that the nuts remain tight. If loose, tighten.
-Power Cord: Inspect condition of power cord for projector.
Wiring Diagrams
Optional Lift Low Voltage (& Wireless) Control
Lift LVC — AeroLift 25 Wiring Diagram
Safety Up Switch
White (Common)
White-Neutral (Common) to lift & 110-120V AC
Brown-to lift (directional)
Red-to lift (directional)
Yellow-to 110-120V AC
Black-to 110-120V AC
Green-Ground
To 110 -120V AC Line
3 Button Wall Switch DOWN - Black COM - White UP - Red
Aux Port for connecting additional
Lift Low Voltage Control modules
(up to six total-connect from Aux to Eye).
Eye Port for IR Eye or RF Receiver. Splitter is required if both are used with one Lift Low Voltage Control.
N
Red (Up)
Up
Black ( Down)
Dn
Green (Ground)
Location of key operated 0n-off switch if furnished.
MOTOR
Dashed Wiring By electrician.
Low voltage wiring by others.
Location of key
operated on-off switch if furnished
Single Station Control Optional Multiple Station Control
Safety Up Switch
21/8" x 17/8" deep
Motor
White (Common)
Red ( Up)
N
UP
Red
Black
Green (Ground)
Black (Down)
DN
Blue
by electrician
Safety Up Switch
21/8" x 17/8" deep
Location of key operated 0n-off switch if furnished.
White (Common)
N
Red (Up)
Black ( Down)
UP
Red
Black
Red
Black
Red
Black
MOTOR
Green (Ground)
DN
Blue
Blue
Blue
Cap off with wire nut and tape.
By electrician.
.draperinc.com (765) 987-7999