Access Fit/Series V
Specifications—Access Fit/Series V
Projection screens, size ___________________ h. x
_____________________ w., recessed ceiling mounting. Case
back, top, and front constructed of steel. Endcaps are steel. Bottom
panel forms slot for passage of viewing surface, easily removable
for access. Symmetrical housing to allow for left or right-hand motor
location, and for viewing surface to unroll from the back or front of the
roller. Case to include bottom flange for trim around edges of ceiling
opening. Case may be mounted with 3/8" threaded rod, with lag screws through
brackets, or with wire in a grid ceiling. Mounting brackets slide in 18" long channels
on top of case, allowing brackets to be moved to avoid interference with conflicting
building structures. Brackets may be locked in position by tightening screws.
Brackets may also be angled to meet installation requirements.
Roller/fabric assembly may be installed in case at factory or job site. Brackets
supporting roller/fabric assembly to slide in track inside top of case, allowing
viewing surface to be centered in case regardless of screen size. Roller of 2" dia.
steel. Top of HDTV and 16:9 format viewing surfaces through 110" diagonal masked
by 12" black drop. Viewing surface flame and mildew resistant. Matt White XT1000V
and Contrast Grey XH800V viewing surfaces are certified to GREENGUARD
standards for low chemical emissions into indoor air during product usage.
For more information, visit ul.com/gg.
Please Mark aPProPriate selections
Select Shipping Option:
Case Now, Screen Assembly Later 1
Complete Unit Now
Select Case Color:
White (standard)
Black (optional)
Select Viewing Surface:
Matt White XT1000V (1.0 gain): GREENGUARD Gold certified
Grey XH600V (0.6 gain) (Thru 9' x 12'): GREENGUARD Gold certified
Pearl White MH1500V (1.5 gain) (Thru 9' x 12'): Optional
Pure White XT1300V (1.3 gain): Optional
Rear Projection Surface: Optional _________________________
Other__________________________________________________________
Select Motor and Controls:
Standard Voltage Motor and Control Options:
110-120V AC (standard)
Optional Quiet Motor
Please Note: These motors come with one 110V-120V AC 3-position wall switch
(silver wall plate with black rocker).
Total number of 110-120V AC switches (operate independently)
Substitute white switch(es) for silver wall plate with black rocker
Optional Key Operated Switch
Power Supply Key Switch (On-off)
3-Position Key Control
3-Position Switch with Hinged Key-Locking Coverplate
Low Voltage Motor and Control Options:
Internal LVC-IV (Low Voltage Control Module)
External LVC-IV (Low Voltage Control Module)
Motor with Built-In Low Voltage Controller
Quiet Motor with Built-In Low Voltage Controller
Please Note: Select Control Options for Low Voltage from below.
24 Volt 3-Button Switch Number of 24V switches:
Radio Frequency Remote Control (only with 24v)
Infrared Remote Control (only with 24v)
Optional Key Operated Switch
Power Supply Key Switch (On-off)
3-Position Switch with Hinged Key-Locking Coverplate
Select Motor Location:
Left end (standard)
Right end
Optional Accessories:
Additional set of mounting brackets for alternate mounting (see page 2)
Additional Drop (Beyond standard 12")
Total Drop (Standard 12" + Additional drop)
(Total screen height cannot exceed 96")
Black (standard)
Same color as viewing surface
2
1
1, 3
5
assembly later at job site
Electrically operated 110-120V AC, 60 Hz. 4-wire motor mounted inside screen
roller, 1.1 amp current draw, instantly reversible, lifetime lubricated, with internal
thermal overload protector and electric brake,standard motor with preset accessible
switches. Optional Quiet Motor operates at 44 Db (motor noise is approximately
30% less than standard tubular motors). Housing to feature internal junction box,
allowing it to be installed and wired to building supply wires at an early stage of
construction. Junction box to have plug-in style connector, accepting the mating half
of the connector from the motorized roller/fabric assembly. 3-position control switch
(or switches—specify number) to stop or reverse screen at any point. Switch(es)
furnished with cover plate. Patented by Draper, Inc.
Patent information available at http://www.draperinc.com/legal/patents/
Downloadable 3-part specifications are available at www.draperinc.com.
Entire unit certified by Underwriters’ Laboratories for the U.S. and Canada.
Plenum rated case (UL approved “Suitable for Use in Environmental Air Space”).
Specifications subject to change without notice.
Dimensions & Data
Nominal
Diagonal
16:10 Format
94" 50" x 80" 107" 90 7/8 76
109" 57½" x 92" 119" 103
113" 60" x 96" 126" 107¾" 80
123" 65" x 104" 131" 115
HDTV Format (16:9)
92" 45" x 80" 107" 90
100" 49" x 87" 113" 97
106" 52" x 92" 119" 102
110" 54" x 96" 126" 107
119" 58" x 104" 131" 115
NTSC Video Format (4:3)
100" 60" x 80" 107" 91
10' 72" x 96" 126" 108
11' 78" x 104" 132" 116
Size
H x W
Audio Visual Format
50" x 50" 76" 60
60" x 60" 87" 71
70" x 70" 98" 85
84" x 84" 113" 96
72" x 96" 126" 108
Custom Size
1
Please note: When ordering a motor with built-in Low Voltage Controller, if the case ships separate
from the "guts," the case includes the 25' cable and special low voltage switch.
2, 3
For size limitation charts for Quiet Motors and Quiet Motors with Built-In Low-Voltage Controller,
see below.
4
Factory-installed VIC will not increase overall case lengths shown at right.
5
Extra drop increases case and dowel length. Specify at time of order and contact Draper if this
dimension is critical. Case sizes include
ceiling cutout size.
AV NTSC HDTV 16:10
108" x 144" 180" 161" 165"
Also available in 1.85:1, 2.35:1 and 15:9 Formats. Contact Draper.
PROJECT:
Ceiling recess case now. Install screen/roller
Image
Area
Case
Length
5
Dowel
Length
6' 42½" x 56½" 85" 67
7' 50" x 66 ½" 92" 77
Dowel
5
Length
3 Quiet Motor w/ LVC Size Limitations
AV NTSC HDTV 16:10
96" x 96" 11' 119" 123"
2 Quiet Motor Size Limitations
Case
Length
11
/16"
flange on each end of case. Subtract 1¼" for rough
by
Net Wt.
(lbs.)
7
/8" 80
7
/8" 85
7
/8" 76
7
/8" 80
7
/8" 80
7
/8" 80
7
/8" 85
3
/8" 60
3
/8" 68
7
/8" 73
7
/8" 92
7
/8" 98
Net Wt.
(lbs.)
7
/8" 58
7
/8" 66
7
/8" 69
7
/8" 74
7
/8" 92
Qty.
Qty.
Copyright © 2017 Draper Inc. Form AccessFitV_Sub17 Printed in U.S.A.
ARCHITECT:
CONTRACTOR:
SUPPLIER:
DATE: REVISED:

Access Fit/series V by DrAper
Single Station Control
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green (Ground)
Dashed wiring
by electrician
Control
switch
Single gang box by others
Min. 4" x 2
1
/8" x 1
7
/8" deep
Red
Black
Blue
Location of key
operated on-off
switch if furnished
To 110-120V Line
Multiple Station Control
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green (Ground)
Dashed wiring
by electrician
Red
Red
Black
Blue
Blue
Cap off with wire
nut and tape
Black
Red
Blue
Black
Single gang box by others
Min. 4" x 2
1
/8" x 1
7
/8" deep.
3 shown. More or less equally
feasible.
Location of key
operated on-off
switch if furnished
To 110-120V Line
Single Low Voltage Control
Multiple Low Voltage Controls
7
/
8
"
ELECTRICAL
CUTOUT
Mounting Bracket Dimensions
7
cAse Dimensions AnD methoDs oF instAllAtion
pAge 2 oF 2
7¾”
1
1
511/16”
/8”
7
/8”
3”
5
/8”
2”
7
4
/8”
7
6
/16”
Standard Motor Wiring is on the
½”
7
/16”
5
/8”
1
/8”
5
18”
L*
*L = Varies
AUDIENCE LEFT END of Access Fit Case.
For minumum length of ceiling cutout: subtract 1¼" from case length (measured from outer edge of flanges).
For minimum width of cutout (front to back): see case width dimensions below.
**There are several knock-outs in the screen housing to allow the Leveling Bracket to be adjusted laterally (up to 16" in either direction)
Alternate
Installation
Typical
Installation
Standard Motor Wiring is on the AUDIENCE LEFT END of Access Case.
1
With typical installation, brackets may be angled to meet installation requirements.
1
(additional set of
brackets required
but not included)
¾”
/16"
LEVELING BRACKET**
8”
13/8”TYP
53/8”
7
/8”
11
/16”
15/8”
1
/2"
1
R
/4"
1
3
/8"
/8"
1
/4"
TYP.
1
1
/2"
9
/16"
TYP.
3
R
/16"
3
/16"
27/8"
1
/4"
1
7
/16"
3
6½"
7¾"
110-120V Motor and Quiet Motor
Please Note:
For external low voltage (LVC-IV), serial (LVC-IV) and network (LVC-IV) wiring
diagrams, please consult instructions for those modules.
Wiring DiAgrAms
.draperinc.com
2
110-120V Motor and Quiet Motor
(Internal Low Voltage Controller)
Internal Screen Wiring
White (Neutral)
Black
Green/Yellow (Ground)
Dashed wiring
Dashed wiring
by electrician
To 110-120V Line
2
For more information and wiring diagrams for serial and network
Data Cable
connector
Wall Switch,
RF or IR
Receiver,
or integrated
control system
RJ-9
To 110-120V Line
by electrician
communication, please see wiring diagrams supplied with individual items.
PROJECT:
SUPPLIER:
DATE: REVISED:
(765) 987-7999
Internal Screen Wiring
White (Neutral)
Black
Green/Yellow (Ground)
Data
Cables
RJ-9
connectors
Wall Switches,
RF or IR
Receivers,
or integrated
control systems