Draper 121227 Instructions

Page 1
Low Voltage
Tr igger
IR Eye
RS232/485
Inputs/Outputs
Wiring Instructions
Infrared Remote Control by Draper
Wiring Diagram for Infrared Remote Control with LVC-IV
White-Neutral (Common) to screen & 110V-120V AC Red-to screen (directional) Brown-to screen (directional) Yellow-to 110V-120V AC Black-to 110V-120V AC
250 VAC 5x20mm
FUSE - 3.15 AMP
LVC-IV
Green-Ground
Dashed wiring by electrician
IR Transmitter
Transmitter range: 26 feet
Wire to connect power to LVC-IV should be between 18 AWG and 12 AWG (solid or stranded) 2 conductors with ground. Wire size needs to be sufficient to carry the motor load. Red and Black wires are the “open” and “close” leads from the motor. The LVC-IV comes enclosed in a metal box with appropriate spacing between the wires and any exposed parts of the box. IR Eye is connected to LVC-IV using low voltage modular data or telephone cord (RJ11), which is isolated from the AC power line.
InfraRed (IR) Remote Control
1 Plug Optional IR Eye into mini plug input provided on LVC-IV. 2 IR Remote Control transmitter does not need to be "learned" by the LVC-IV. Simply point and operate. 3 Maximum IR Eye cable length is 42".
Battery Replacement for IR Remote Control
1 Slide off cover from the back of IR Remote Control. 2 Remove both CR2032 3-volt batteries and replace.
Remove
Cover
CR 2032
CR 2032
3V
3V
+
+
Copyright ©2015 Draper Inc. Form IRRemoteControl_Wiring15 Printed in U.S.A.
If you encounter any difficulties installing/wiring your IR Remote Control, call your dealer or Draper, Inc., Spiceland, Ind., (765) 987-7999; or fax (765) 987-7142.
Page 2
Low Voltage
Transmitter range: 7.9 meter
Tr igger
3-28 VDC
IR Eye
RS232/485
Inputs/Outputs
Wiring Instructions
230V Infrared Remote Control by Draper
Wiring Diagram for Infrared Remote Control with LVC-IV
White-Neutral (Common) to screen 230V AC Red-to screen (directional) Brown-to screen (directional) Yellow-to 230V AC Black-to 230V AC
250 VAC 5x20mm
FUSE - 3.15 AMP
LVC-IV
Green-Ground
Dashed wiring by electrician
IR Transmitter
Wire to connect power to LVC-IV should be between 18 AWG and 12 AWG (solid or stranded) 2 conductors with ground. Wire size needs to be sufficient to carry the motor load. Red and Black wires are the “open” and “close” leads from the motor. The LVC-IV comes enclosed in a metal box with appropriate spacing between the wires and any exposed parts of the box. IR Eye is connected to LVC-IV using low voltage modular data or telephone cord (RJ11), which is isolated from the AC power line.
InfraRed (IR) Remote Control
1 Plug Optional IR Eye into mini plug input provided on LVC-IV. 2 IR Remote Control transmitter does not need to be "learned" by the LVC-IV. Simply point and operate. 3 Maximum IR Eye cable length is 106cm.
Battery Replacement for IR Remote Control
1 Slide off cover from the back of IR Remote Control. 2 Remove both CR2032 3-volt batteries and replace.
Remove
Cover
CR 2032
CR 2032
3V
3V
+
+
Copyright ©2015 Draper Inc. Form IRRemoteControl-230V_Wiring15 Printed in U.S.A.
If you encounter any difficulties installing/wiring your IR Remote Control, call your dealer or Draper, Inc., Spiceland, Ind., (765) 987-7999; or fax (765) 987-7142.