Read instructions through completely before proceeding.
Caution
Follow instructions carefully. Installation contrary to instructions invalidates
warranty.
Screen should be accessible for complete removal should fabric become
damaged or should other service be required.
Screen should be installed level (using a carpenter’s level).
Nothing should be fastened to screen dowel or viewing surface.
Operating switch(es) packed separately in screen carton. Do not discard
with packing material.
Screen operates on 110-120V, 60 hz., 1.1 amp current draw.
NOTE: Screen has been thoroughly inspected and tested at factory and
found to be operating properly prior to shipment.
These instructions are meant as a guide only. They do not imply any
responsibility on the part of Draper, Inc. for improper installation or faulty
workmanship at the jobsite.
Hanging Screen
General:
When locating viewing surface and checking clearance for screen’s operation,
remember surface is centered in case. Handle case carefully to protect its finish.
Regardless of mounting method, screen should be positively and securely supported so that vibration or even abusive pulling on the viewing surface will not
cause case to work loose or fall. Installer must insure that fasteners used are of
adequate strength and suitable for the mounting surface chosen.
Suspended Installation:
Suspend screens from holes in endcaps as shown. “S” hooks, chains (or cable)
and turnbuckles should be provided by installer. “S” hooks should go through
the front holes on the endcaps (see drawing on page 3), and both ends of the
“S” hooks should be crimped for additional safety. Chains should be attached to
beams or other structural members. Turnbuckles should be adjusted so screen
hangs level.
Wall Installation:
Mount screen through holes in back of endcaps as shown. Installer should
furnish screws, toggle bolts, molly bolts, nylon or lead anchors as required.
Wall Installation with 6" Extension Brackets:
Mount the brackets (not included with screen—see diagram on page 2) using
hardware recommended for “Wall Installation” (above). Then, suspend the
screen from the front holes with “S” hooks (as in “Suspended”). For added
safety, be sure to crimp both ends of the “S” hooks so the screen cannot
come off. For a more rigid installation, mount the screen from the back holes
to the front of the bracket by using the screws and nuts provided with the
brackets.
Wall or Ceiling Installation with Floating Brackets:
Floating brackets should be located on studs or joists. The bracket then
attaches at any almost any point along the case. For details, see separate
instruction sheet that ships with the Floating Wall Bracket.
Recessed Installation:
Recess should permit access for removal of screen if necessary. Screen may
be mounted as in suspended or wall installation. Optional Ceiling Opening
Trim Kit available; see diagrams below and on page 3, and separate instruction
sheet (included with Ceiling Opening Trim Kit). The Ceiling Opening Trim Kit is
for use in an acoustical, drop ceiling only. Not recommended for drywall or hard
ceilings.
Electrical Connections
Screen operates on 110-120V, 60 hz., 1.1 amp current draw. Duty cycle: On 28
seconds/Off 4 minutes.
Junction box is located inside left endcap and cover plate is secured to endcap
with two screws which may be removed with a Torx-head or small straightblade screwdriver. Junction box contains red, black and white pigtail leads and
green internal ground wire, per wiring diagram on reverse.
Screen is shipped with internal wiring complete and control switch(es) fully
boxed. Wire connecting screen to switch(es) and switch(es) to power supply should be furnished by installer. Please Note: Screen must be installed in
accordance with the requirements of the Local Building Codes, the Canadian
Electrical Code (CEC), CAN/CSA C22.1 and the National Electric Code (NEC),
NFPA 70. An appropriate disconnect device shall be provided as part of the
building installation. Please Note: Do NOT wire motors in parallel.
All operating switches should be “off” before power is connected.
Plug-in power cord option available with built-in low voltage motor.
For Reconfiguration/Conversion of Non-detachable Power Cord to
Field Wiring for Models TAR-28, TAR-29 and TAR-30 Only:
1 Disconnect cord plug from outlet.
2 Remove junction box cover.
3 Disconnect wire nuts from black, white and green wires.
4 Remove power cord and strain relief from screen.
5 Connect the black motor wire to "hot" supply wire.
6 Connect white motor wire to "neutral" supply wire.
7 Connect green/yellow wire to "ground" supply wire.
8 Replace junction box cover.
Before operating screen remove tape securing fabric and dowel to roller. If viewing surface hangs out of case 8"-9", tape has probably been broken by rough handling in shipment, allowing surface to “unwrap” one turn about the roller. Manually
wrap fabric back around the roller without turning the roller itself.
110-120V Single Station Control — 3-position up-off-down switch permits operation to be stopped at any point. Factory adjusted limit switches automatically stop
screen when fully down or fully up.
110-120V Multiple Station Control—Switches are similar in appearance to 110120V Single Station Control. Screen stops when switch is released and may be
restarted in either direction. Factory adjusted limit switches stop screen automatically when fully down or fully up.
24V Control — Three-button up-stop-down switches stop at any point desired,
operate in any sequence. Factory adjusted limit switches automatically stop
screen when fully down or fully up.
Key Operated Switching — Two kinds of key-operated switches are optionally
available with this unit. The key-operated power supply switch controls power to
the screen and switches. When it is “off”, the switches will not operate screen. Key
may be removed from the switch in either “on” or “off” position. A three-position
key switch permits the screen to be operated directly by key. In this case, the
screen’s operator must always have a key.
RS232/Ethernet—Serial communication and network communication optionally
available with wall switches, RF or IR remote.
Plug & PlayTM—Provided with handheld IR remote control transmitter and
10' (3m) cord. No wiring necessary except to connect to RS232. Screen is
equipped with a handheld remote or 3-position operating switch (see below).
Three positions (up-off-down) permit operation to be stopped at any point.
Factory adjusted limit switches automatically stop screen when fully down or
fully up.
Please Note: Screen limits are factory set for optimum performance of the
screen. Any adjustment of these limits could void the warranty. Please
check with Draper prior to resetting screen limits.
(Height adjustments are made at the motor using white/yellow screws)
Tools needed: Flashlight, small flathead screwdriver/Allen wrench (4mm or
5
/32").
adjustment is being tested. Screen may be severely damaged if viewing
surface is allowed to run too far up or too far down.
The motor limit screws are normally located on the audience left of screen
roller, and the viewing surface rolls off the back of the roller. If the viewing
surface is coming off the front of the roller (motor on left), or the motor is on the
audience right of the screen roller (with viewing surface rolling off the back),
reverse the following instructions.
Ceiling Trim KitFloating Mounting Bracket
Screen Case
Back
Ceiling Tile
(By others)
Operation
Limit Adjustments (Standard Motors)
CAUTION: Always be prepared to shut screen off manually when new
(Continued on next page)
If you encounter any difficulties installing or servicing your Targa screen, call your
dealer or Draper Inc., Spiceland, Indiana, (765) 987-7999 or fax (765) 987-7142.
Page 2
Targa by Draper
www
9
Back View
STOP
ToMotorwithBuilt-InLow Voltage
BackView
Up
Down
C
omm
o
n
+5VDC
ToMotorwithBuilt-InLow Voltage
To Reduce Screen Drop
"DOWN" LIMIT ADJUSTMENT
Raise screen surface about 1' above
desired setting and turn off.
Turn the DOWN limit screw clockwise
(three screw turns = ½ roller revolution).
I
DOWN Limit
+
Counterclockwise
increases down travel
Test by running screen down and repeat
steps 1 and 2 until desired position
is reached.
To Increase Screen Drop
Run screen to the down limit.
+
UP Limit
I
Counterclockwise
increases up travel
With the down switch on, turn the
DOWN limit screw counterclockwise
(three turns of screw equals ½ roller revolution) to increase drop.
Test by running screen up about 1' and back down to new down limit.
Repeat steps 2 and 3 until desired position is reached.
"UP" LIMIT ADJUSTMENT
Screen is Running Too Far Up
Lower screen surface about 1' below desired setting and turn off.
Turn the UP limit screw clockwise (three screw turns = ½ roller revolution).
Test by running screen up.
Repeat steps 1 through 3 until desired position is reached.
Screen Needs to Run Up More
Run screen down about 1' and turn off.
With the up switch on, turn the UP limit screw counterclockwise (three turns
of screw equals ½ roller revolution).
Repeat steps 1 and 2 until desired position is reached.
CAUTION: Do NOT allow the dowel to wrap up over the roller when the
screen is running up! This could damage the screen.
Limit Adjustments (Quiet Motors)
Please Note: Screen limits are factory set for optimum performance
of the screen. Any adjustment of these limits could void the warranty.
Please check with Draper prior to resetting screen limits.
(Height adjustments are made at the motor using white/yellow screws)
Tools needed: Flashlight, small flathead screwdriver/Allen wrench (4mm or
5
/32").
CAUTION: Always be prepared to shut screen off manually when new
adjustment is being tested. Screen may be severely damaged if viewing
surface is allowed to run too far up or too far down.
The motor limit screws are normally located on the audience left of screen
roller, and the viewing surface rolls off the back of the roller. If the viewing
surface is coming off the front of the roller (motor on left), or the motor is on
the audience right of the screen roller (with viewing surface rolling off the
back), reverse the following instructions.
To Reduce Screen Drop
Raise screen surface about 1' above desired setting and turn off.
Turn the DOWN limit screw ("I" or white) clockwise (three screw turns = ½
roller revolution).
Test by running screen down and repeat steps 1 and 2 until desired
position is reached.
To Increase Screen Drop
Run screen to the down limit.
With the down switch on, turn the DOWN limit screw ("I" or white)
counterclockwise (three turns of screw equals ½ roller revolution) to
increase drop.
Test by running screen up about 1' and back down to new down limit.
Repeat steps 2 and 3 until desired position is reached.
Screen is Running Too Far Up
Lower screen surface about 1' below desired setting and turn off.
Turn the UP limit screw ("II or yellow") clockwise (three screw turns = ½
roller revolution).
Test by running screen up.
Repeat steps 1 through 3 until desired position is reached.
Screen Needs to Run Up More
Run screen down about 1' and turn off.
With the up switch on, turn the UP limit screw ("II or yellow")
counterclockwise (three turns of screw equals ½ roller revolution).
Repeat steps 1 and 2 until desired position is reached.
CAUTION: Do NOT allow the dowel to wrap up over the roller when the
screen is running up! This could damage the screen.
"DOWN" LIMIT ADJUSTMENT
"UP" LIMIT ADJUSTMENT
Please Note: Screen limits are factory set for optimum performance
of the screen. Any adjustment of these limits could void the warranty.
Please check with Draper prior to resetting screen limits.
(Height adjustments are made from wall switch)
Connect the switch to the motor via the terminal blocks, or via the modular
port using four conductor modular cable. When using modular cable, the
cable connectors MUST NOT be crimped in reverse, as with standard
telephone cable.
Set the slide switch to the lower position. Press and hold the DOWN button
on the switch to move the viewing surface to the desired lower limit. If the
screen moves in the opposite direction, release the DOWN button and
press and hold down the STOP button for four seconds. This will reverse
the operation of the UP and DOWN switches.
3 Move slider switch into center position.Wait a couple of seconds.
Please Note: If you move the slider switch
from down to up in one motion it sets the two limits in the same position.
Set the slide switch to the higher position. Move the viewing surface to the
desired upper limit by pressing and holding the UP button on the wall
switch.
Return the slide switch to the center position to return to normal operation.
To set the viewing surface to an alternate format position, move the viewing
surface to the desired position and press the STOP button. Press and
hold STOP for at least three seconds to record the position.
Please Note: Pressing and releasing the UP button on the switch will move
the screen to its upper limit. Pressing and releasing the DOWN button will
move the screen to its lower limit.
While the motor is in motion, pressing STOP for less than two seconds will
stop the viewing surface at its present position.
Once the motor is stopped, pressing the STOP button will move the viewing
surface to its alternate format position.
Pressing and holding the STOP button, when the motor is at rest or in motion, for at least three seconds will record a new alternate format position.
Page 2 of 4
Limit Adjustments (Built-in Low Voltage Motors)
To Motor
with
Built-In
+
C
5V
o
Low Voltage
DC
m
m
o
n
POSITION
DOWN
CENTER
To Motor
with
Built-In
Low Voltage
UP
FUNCTION
Set LOWER limit
Set UPPERlimit
Normal Operation
Slide
Switch
U
D
p
o
w
n
STO P
Please Note: 5V DC must be
connected to be able to set
limits using the wall switch.
.draperinc.com
(765) 987-799
Page 3
25/16"
5
7
/8"
5¼"
7
/8" dia.
electrical
connection
hole
3½"
Viewing
Surface
Fabric width + 7"
Appropriate hardware
provided by installer.
Appropriate hardware
provided by installer.
7
electr
connection.
Fasteners for
Targa by Draper
www
9
Page 3 of 4
Case Dimensions
6" Extension
Bracket
/8" hole for
ical
Types of Installation
Wall Mounted
Methods of Installation
wall mounting
by others.
S Hooks for
suspended
installation
by others.
Suspended
Optional Ceiling Opening Trim Kit
(Dims-Side View)
8"
1
21/8"
1
4"
3
/4"
6
/16"
1
2
/16"
Built-in Low Voltage Motor: Switch-to-Motor—Dry Contacts or Data Cable connection
Please Note: This Splitter/Jack
is located inside the motor-end
endcap of your screen. To access, remove access panel from
endcap.
Data Cables to switches or
to additional motors can be
plugged into any of the three
open jacks.
Back of wall switch.
UPD
O
W
N
.draperinc.com
Motor Data Cable
plugged in here
C
5V
O
M
M
O
N
COM
DWN
5V
UP
(765) 987-799
Please Note: 5V DC must be
connected to be able to set
limits using the wall switch.
Please Note: Although both Dry
Contact and Data Cable connections
are shown, you should only use one
connection type per motor.
Page 4
Targa by Draper
www
9
Single Station Control
Internal Screen Wiring
White (Common)
Black (Directional)*
Red (Directional)*
Green/Ye llow (Ground)
Dashed wiring
by electrician
Control
switch
Single gang box by others
Min. 4" x 2
1
/8" x 17/8" deep
Blue
Black
Red
Location of key
operated on-off
switch if furnished
To 110-120V Line
Multiple Station Control
Internal Screen Wiring
White (Common)
Black (Directional)*
Red (Directional)*
Green/Ye llow (Ground)
Dashed wiring
by electrician
Red
Red
Black
Blue
Blue
Cap off with wire
nut and tape
Black
Red
Blue
Black
Single gang box by others
Min. 4" x 2
1
/8" x 17/8" deep.
3 shown. More or less equally
feasible.
Location of key
operated on-off
switch if furnished
To 110-120V Line
Motor Type Up Down
Standard Black Red
Quiet Red Black
*Motor Direction
Internal Screen Wiring
)
Internal Screen Wiring
110-120V
Single Low
Multiple Low
Single Low Voltage Control
Multiple Low Voltage Controls
*Motor Direction
Quiet Red Black
*Motor Direction
Page 4 of 4
Wiring Diagrams (Standard and Quiet Motors)
Please Note: Do not wire motors in parallel.
Wiring Diagrams—Plug & Play 110-120V Motor
with Built-in Low Voltage Controller
Voltage Control
Internal Screen Wiring
White (Neutral)
Black
Green (Ground)
Data Cable
Wall Switch,
RF or IR
110-120V
Plug
Receiver,
or integrated
control system
110-120V
Plug
Voltage Controls
Internal Screen Wiring
White (Neutral)
Black
Green (Ground)
Data
Cables
Wall Switches,
RF or IR
Receivers,
or integrated
control systems
Wiring Diagrams—110-120V Motor and Quiet Motor
with Built-in Low Voltage Controller
External Low Voltage and Remote Control
To
Line
110-120V
White (Common)
Directional*
Directional*
Green (Ground)
Dashed wiring by electrician
White-Common to screen & 110-120V AC Neutral
Red-to screen (directional)
Brown-to screen (directional)
Ye llow-to 110-120V AC-Hot
Black-to 110-120V AC-Hot
Green-Ground
Low voltage wiring by others
Eye Port for IR Eye, RF Receiver or LED
Location of key
operated on-off
switch if furnished
STOP
STOP
Wall Switch. For more than one of
these, a splitter is required.
3 Button Wall Switch
DOWN - Black
COM - White
See separate Serial Communication-RS232 Instruction sheet for enabling RS232 with the MC1.
Motor Type Up Down
Standard Black Red
Quiet Red Black
Control
Switches
24v DC
To 110-120V Line
External Two-Way Serial Communication (RS232) with MC1
Aux Port for connecting additional LVC-III
modules (up to six total can be linked-
connect from Aux to Eye).
UP - Red
.draperinc.com
Dashed wiring
by electrician
Program LED
Fuse
MC1
(765) 987-799
Internal Screen Wiring
White (Neutral)
Black
Green/Yellow (Ground)
Data Cable
RJ-9
connector
Wall Switch,
RF or IR
Receiver,
or integrated
control system
White-Common to screen & 110-120V AC Neutral
Red-to Screen (directional)
Brown-to Screen (directional)
Black-Hot to 110-120V AC
Green/Yellow-Ground
Low Voltage Wiring by others
AC Wiring by electrician
RS232 Data FROM Control System
RS232 Data TO Control System
Signal Ground & Manual Switch Common
Manual Switch Down
Manual Switch Up
Eye Port for IR Eye. For RF Receive r or LED
Wall Switch, a Splitter and a Power Supply
is required. Plug RF Receiver or LED Wall
Switch and Power Supply into splitter, then
run cable from Splitter to MC1 Eye Port.
Dashed wiring
by electrician
To 110-120V Line
Internal Screen Wiring
White (Neutral)
Black
Green/Yellow (Ground)
Data
Cables
RJ-9
connectors
Wall Switches,
RF or IR
Receivers,
or integrated
control systems
White (Common)
Directional*
Directional*
Green/Yellow (Gnd
STOP
Location of key
operated on-off
switch if furnished
STOP
Control
Switches
24v DC
Motor Type Up Down
Standard Black Red
Line
To